Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
BMC Oral Health ; 19(1): 85, 2019 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-31113410

RESUMO

INTRODUCTION: Mandibular Advancement Devices (MAD) have been reported to be an alternative treatment to CPAP in moderate to severe obstructive sleep apnea (OSA) cases. The design of MAD has a major influence on its success rate on the patient, and design features that have an influence on efficacy, tolerance, and compliance. The aim of this study was to determine the range of mandibular protrusion at different vertical points; 2, 5, 8 and 11 mm in a young adult population. METHODS: Fifty two students aged 19 to 23 years (mean 21.3 ± 1.7; 29 females and 23 males), with full permanent dentition participated in the study. The absolute range of maximal mandibular protrusion and retrusion was measured (mm) with the use of the George Gauge. Descriptive statistics, ANOVA and paired t-test using SPSS were used. RESULTS: Range of mandibular advancement was possible to be determined for the 4 levels of vertical opening with the gauges: 2 mm fork mean mandibular advance 13,10 mm ± 0.604; 5 mm mean 11.98 mm ± 1.075; 8 mm mean 11.20 mm ± 1.369; 11 mm mean 9.87 mm ± 1.886. No significant differences were found between class I, II, and III. CONCLUSIONS: There is an impact of increased inter-incisal distance of effective mandibular protrusion when constructing a MAD. As vertical dimension increases the mandible rotates posteriorly and places itself in a more retrusive location, and the range of mandibular advancement reduces (0.3 mm for every 1 mm of vertical increase).


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Mandíbula , Resultado do Tratamento , Dimensão Vertical , Adulto Jovem
2.
Head Face Med ; 12(1): 32, 2016 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-27832820

RESUMO

BACKGROUND: To determine three-dimensional spatial orbit skeletal changes in adolescents over a 19 to 24 months observation period assessed through cone-beam computed tomography (CBCT). METHODS: The sample consisted of 50 adolescents aged 11 to 17. All were orthodontic patients who had two CBCTs taken with an interval of 19 to 24 months between images. The CBCTs were analyzed using the third-party software Avizo. Sixteen anatomical landmarks resulting in 24 distances were used to measure spatial structural changes of both orbits. Reliability and measurement error of all landmarks were calculated using ten CBCTs. Descriptive and t-test statistical analyses were used to determine the overall changes in the orbits. RESULTS: All landmarks showed excellent reliability with the largest measurement error being the Y-coordinate of the left most medial point of the temporalis grooves at 0.95 mm. The mean differences of orbital changes between time 1 and time 2 in the transverse, antero-posterior and vertical directions were 0.97, 0.36 and 0.33 mm respectively. Right to left most antero-inferior superior orbital rim distance had the greatest overall transverse change of 4.37 mm. Right most posterior point of lacrimal crest to right most postero-lateral point of the superior orbital fissure had the greatest overall antero-posterior change of 0.52 mm. Lastly, left most antero-inferior superior orbital rim to left most antero-superior inferior orbital rim had the greatest overall vertical change of 0.63 mm. CONCLUSIONS: The orbit skeletal changes in a period of 19-24 months in a sample of 11-17 year olds were statistically significant, but are not considered to be clinically significant. The overall average changes of orbit measurements were less than 1 mm.


Assuntos
Desenvolvimento Infantil/fisiologia , Tomografia Computadorizada de Feixe Cônico/métodos , Órbita/diagnóstico por imagem , Órbita/crescimento & desenvolvimento , Adolescente , Fatores Etários , Pontos de Referência Anatômicos , Cefalometria/métodos , Criança , Feminino , Humanos , Imageamento Tridimensional , Masculino , Valores de Referência , Estudos de Amostragem , Fatores Sexuais
3.
Orthod Craniofac Res ; 19(1): 28-35, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26412045

RESUMO

OBJECTIVES: The viscoelastic response of the midpalatal suture during maxillary expansion treatment has been sparsely studied. The aim of our study was to use viscoelastic models to investigate the effect of appliance mechanics on sutural tissue. MATERIALS AND METHODS: Four creep-strain models were utilized in predicting the midpalatal suture's response to a constant-force application during expansion treatment. The functional forms included a three-term separable, three-term inseparable, two-term inseparable, and single-term arrangement. The functions were then transformed into subsequent stress-relaxation representations to predict suture response as a result of 0.25, 0.20, 0.15, and 0.10 mm displacements. Finally, the single-term creep-strain representation was altered to simulate treatment decaying force during treatment. A force that decays 30 and 10% of an initially applied 0.98 N was considered for decaying functions over a 6-week period, and compared to strain resulting from a constant-force application. RESULTS: This analysis illustrated that the decay in suture strain closely followed decay in force and that the path of decay had minimal impact on overall results. Also, it was found that a single screw activation would likely not cause suture soft tissue failure, even for a 0.25 mm displacement, and that suture stress rapidly decayed within minutes of activation. CONCLUSION: Results from this study support the notion of maintaining a low-magnitude constant traction on the suture during treatment to avoid soft tissue failure and promote tissue remodeling.


Assuntos
Técnica de Expansão Palatina , Suturas , Suturas Cranianas , Humanos , Palato
4.
Orthod Craniofac Res ; 18(2): 65-76, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25677755

RESUMO

A systematic review was undertaken to evaluate the validity of intra-arch dimensional measurements made from laser-scanned digital dental models in comparison with measurements directly obtained from the original plaster casts (gold standard). Finally included articles were only those reporting studies that compared measurements from digital models produced from laser scanning against their plaster models. Measurements from the original plaster models should have been made using a manual or digital caliper (gold standard). Articles that used scans from impressions or digital photographs were discarded. Detailed individual search strategies for Cochrane, EMBASE, MEDLINE, PubMed, and LILACS were developed. The references cited in the selected articles were also checked for any references that could have been missed in the electronic database searches. A partial gray literature search was undertaken using Google Scholar. The methodology of selected studies was evaluated using the 14-item quality assessment tool for diagnostic accuracy studies (QUADAS). Only 16 studies were finally included for the qualitative/quantitative synthesis. The selected studies consistently agree that the validity of measurements obtained after using a laser scanner from plaster models is similar to direct measurements. Any stated differences would be unlikely clinically relevant. There is consistent scientific evidence to support the validity of measurements from digital dental models in comparison with intra-arch dimensional measurements directly obtained from them.


Assuntos
Cefalometria/estatística & dados numéricos , Arco Dental/anatomia & histologia , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Lasers , Modelos Dentários/estatística & dados numéricos , Imagem Óptica/estatística & dados numéricos , Simulação por Computador , Humanos , Reprodutibilidade dos Testes
5.
J Biomech ; 46(10): 1618-25, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23684080

RESUMO

Maxillary expansion treatment is a commonly used procedure by orthodontists to widen a patient's upper jaw. As this is typically performed in adolescent patients, the midpalatal suture, connective tissue adjoining the two maxilla halves, remains unfused. Studies that have investigated patient response to expansion treatment, generally through finite element analysis, have considered this suture to behave in a linear elastic manner or it was left vacant. The purpose of the study presented here was to develop a model that could represent the midpalatal suture's viscoelastic behavior. Quasilinear viscoelastic, modified superposition, Schapery's, and Burgers modeling approaches were all considered. Raw data from a previously published study using New Zealand White Rabbits was utilized for model parameter estimation and validation. In this study, Sentalloy(®) coil springs at load levels of 0.49N (50g), 0.98N (100g), and 1.96N (200g) were used to widen the midsagittal suture of live rabbits over a period of 6 weeks. Evaluation was based on a models ability to represent experimental data well over all three load sets. Ideally, a single set of model constants could be used to represent data over all loads tested. Upon completion of the analysis it was found that the modified superposition method was able to replicate experimental data within one standard deviation of the means using a single set of constants for all loads. Future work should focus on model improvement as well as prediction of treatment outcomes.


Assuntos
Modelos Biológicos , Técnica de Expansão Palatina , Palato/fisiologia , Animais , Elasticidade , Coelhos , Viscosidade
6.
Dentomaxillofac Radiol ; 42(7): 20130035, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23640988

RESUMO

The purpose of this study is to minimize errors that occur when using a four vs six landmark superimpositioning method in the cranial base to define the co-ordinate system. Cone beam CT volumetric data from ten patients were used for this study. Co-ordinate system transformations were performed. A co-ordinate system was constructed using two planes defined by four anatomical landmarks located by an orthodontist. A second co-ordinate system was constructed using four anatomical landmarks that are corrected using a numerical optimization algorithm for any landmark location operator error using information from six landmarks. The optimization algorithm minimizes the relative distance and angle between the known fixed points in the two images to find the correction. Measurement errors and co-ordinates in all axes were obtained for each co-ordinate system. Significant improvement is observed after using the landmark correction algorithm to position the final co-ordinate system. The errors found in a previous study are significantly reduced. Errors found were between 1 mm and 2 mm. When analysing real patient data, it was found that the 6-point correction algorithm reduced errors between images and increased intrapoint reliability. A novel method of optimizing the overlay of three-dimensional images using a 6-point correction algorithm was introduced and examined. This method demonstrated greater reliability and reproducibility than the previous 4-point correction algorithm.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Cefalometria/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Ossos Faciais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Crânio/diagnóstico por imagem , Algoritmos , Pontos de Referência Anatômicos/anatomia & histologia , Meato Acústico Externo/anatomia & histologia , Meato Acústico Externo/diagnóstico por imagem , Ossos Faciais/anatomia & histologia , Forame Magno/anatomia & histologia , Forame Magno/diagnóstico por imagem , Humanos , Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem , Órbita/anatomia & histologia , Órbita/diagnóstico por imagem , Técnica de Expansão Palatina , Reprodutibilidade dos Testes , Estudos Retrospectivos , Crânio/anatomia & histologia , Base do Crânio/anatomia & histologia , Base do Crânio/diagnóstico por imagem , Osso Esfenoide/anatomia & histologia , Osso Esfenoide/diagnóstico por imagem
7.
J Dent Biomech ; 20102010 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-20948570

RESUMO

Objective. Review the reported activation methods of maxillary expansion devices for midpalatal suture separation from an engineering perspective and suggest areas of improvement. Materials and Methods. A literature search of Scopus and PubMed was used to determine current expansion methods. A U.S. and Canadian patent database search was also conducted using patent classification and keywords. Any paper presenting a new method of expansion was included. Results. Expansion methods in use, or patented, can be classified as either a screw- or spring-type, magnetic, or shape memory alloy expansion appliance. Conclusions. Each activation method presented unique advantages and disadvantages from both clinical and engineering perspectives. Areas for improvement still remain and are identified in the paper.

8.
Dentomaxillofac Radiol ; 39(7): 400-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20841457

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the potential errors associated with superimposition of serial cone beam CT (CBCT) images utilizing reference planes based on cranial base landmarks using a sensitivity analysis. METHODS: CBCT images from 62 patients participating in a maxillary expansion clinical trial were analysed. The left and right auditory external meatus (AEM), dorsum foramen magnum (DFM) and the midpoint between the left and right foramen spinosum (ELSA) were used to define a three-dimensional (3D) anatomical reference co-ordinate system. Intraclass correlation coefficients for all four landmarks were obtained. Transformation of the reference system was carried out using the four landmarks and mathematical comparison of values. RESULTS: Excellent intrareliability values for each dimension were obtained for each landmark. Evaluation of the method to transform the co-ordinate system was first done by comparing interlandmark distances before and after transformations, giving errors in lengths in the order of 10-14% (software rounding error). A sensitivity evaluation was performed by adding 0.25 mm, 0.5 mm and 1 mm error in one axis of the ELSA. A positioning error of 0.25 mm in the ELSA can produce up to 1.0 mm error in other cranial base landmark co-ordinates. These errors could be magnified to distant landmarks where in some cases menton and infraorbital landmarks were displaced 4-6 mm. CONCLUSIONS: Minor variations in location of the ELSA, both the AEM and the DFM landmarks produce large and potentially clinically significant uncertainty in co-ordinate system alignment.


Assuntos
Cefalometria/métodos , Tomografia Computadorizada de Feixe Cônico , Base do Crânio/diagnóstico por imagem , Humanos , Técnica de Subtração
9.
Dentomaxillofac Radiol ; 37(6): 305-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18757714

RESUMO

OBJECTIVES: The purpose of this study was to determine the effect of an object's location in a cone beam CT imaging chamber (CBCT-NewTom 3G) on its apparent density and to develop a linear conversion coefficient for Hounsfield units (HU) to material density (g cm(-3)) for the NewTom 3G Scanner. METHODS: Three cylindrical models of materials with different densities were constructed and scanned at five different locations in a NewTom 3G Volume Scanner. The average HU value for each model at each location was obtained using two different types of software. Next, five cylinders of different known densities were scanned at the exact centre of a NewTom 3G Scanner. The collected data were analysed using the same two types of software to determine a standard linear relationship between density and HU for each type of software. RESULTS: There is no statistical significance of location of an object within the CBCT scanner on determination of its density. A linear relationship between the density of an object and the HU of a scan was rho = 0.001(HU)+1.19 with an R2 value of 0.893 (where density, rho, is measured in g cm(-3)). This equation is to be used on a range between 1.42 g cm(-3) and 0.4456 g cm(-3). CONCLUSIONS: A linear relationship can be used to determine the density of materials (in the density range of bone) from the HU values of a CBCT scan. This relationship is not affected by the object's location within the scanner itself.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico/instrumentação , Radiografia Dentária/métodos , Absorciometria de Fóton , Algoritmos , Ossos Faciais/diagnóstico por imagem , Humanos , Modelos Lineares , Imagens de Fantasmas , Software , Tomógrafos Computadorizados
10.
J Oral Rehabil ; 34(6): 397-405, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17518973

RESUMO

This study evaluated the quality of reporting electromyography in studies evaluating the masticatory muscles published during 2004. Several electronic databases were searched. Abstracts and later articles were selected by a consensus from the five reviewers. An adaptation of the methodological checklist published by the International Society of Electrophysiology and Kinesiology (ISEK) was used. The following information regarding electrodes was reported on the 35 finally selected articles: location (94.3%), interelectrode distance (48.6%), and material (42.9%); detection and amplification: amplification type (54.3%), gain (25.7%), low high pass filters (60%) and cut-off frequencies (60%); electromyography (EMG) processing: sampling rate (74.2%), rectification (46.6%), root-mean square (RMS) (39.2%); number of bits and model of A/D card (17.1%); and normalization procedure (40%). Reasons for the poor reporting are discussed. Because of the general poor quality of reporting of the analysed studies, findings of studies using surface electromyography of masticatory muscles should be interpreted with caution.


Assuntos
Eletrodos/normas , Eletromiografia/normas , Músculos da Mastigação/fisiologia , Publicações Periódicas como Assunto/normas , Projetos de Pesquisa/normas , Bases de Dados Bibliográficas , Humanos , Cinesiologia Aplicada/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
11.
Comput Methods Biomech Biomed Engin ; 10(2): 137-49, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18651280

RESUMO

OBJECTIVE: Develop a finite element (FE) model of a skull to perform biomechanical studies of maxillary expansion using bone anchors (BA). MATERIALS AND METHODS: A skull model was developed and assigned material properties based on Hounsfield unit (HU) values of cone-beam computerized tomography (CBCT) images. A 3 mm diameter cylindrical BA was modelled and inserted in the palatal bone. A 4 mm transverse displacement was applied on the anchor. An evaluation on the effect on local stresses of BA implantation inclination angle was performed. RESULTS: Proper displacement results and strain-stress trends for the expansion process were present. Stress distribution patterns were similar as reported in the literature. No significant difference between BA inclination angles was found. CONCLUSION: This work leads to a better understanding and prediction of craniofacial and maxillary bone remodelling during ME with BA treatments and is a first step towards the development of patient specific treatments.


Assuntos
Imageamento Tridimensional/métodos , Maxila/fisiologia , Maxila/cirurgia , Modelos Biológicos , Técnica de Expansão Palatina/instrumentação , Âncoras de Sutura , Simulação por Computador , Análise de Falha de Equipamento , Análise de Elementos Finitos , Humanos , Desenho de Prótese
12.
Dentomaxillofac Radiol ; 35(6): 407-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17082330

RESUMO

OBJECTIVE: The purpose of this study was to determine a conversion coefficient for Hounsfield Units (HU) to material density (g cm(-3)) obtained from cone-beam computed tomography (CBCT-NewTom QR-DVT 9000) data. METHODS: Six cylindrical models of materials with different densities were made and scanned using the NewTom QR-DVT 9000 Volume Scanner. The raw data were converted into DICOM format and analysed using Merge eFilm and AMIRA to determine the HU of different areas of the models. RESULTS: There was no significant difference (P = 0.846) between the HU given by each piece of software. A linear regression was performed using the density, rho (g cm(-3)), as the dependent variable in terms of the HU (H). The regression equation obtained was rho = 0.002H-0.381 with an R2 value of 0.986. The standard error of the estimation is 27.104 HU in the case of the Hounsfield Units and 0.064 g cm(-3) in the case of density. CONCLUSION: CBCT provides an effective option for determination of material density expressed as Hounsfield Units.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Software , Tomografia Computadorizada por Raios X/instrumentação
13.
J Public Health Dent ; 66(2): 152-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16711637

RESUMO

The consequences of xerostomia on oral health have been studied for decades; however, the actual prevalence of this disorder on the general population remains controversial. The purpose of this systematic review was to determine the prevalence of xerostomia in population-based samples. Electronic databases were screened for relevant articles and reference lists of pertinent articles were also hand-searched. Thirteen articles meeting the final inclusion criteria were identified. Based on the definition of xerostomia used in this review, only publications including a subjective diagnosis of the disorder were included. All of the self-reported diagnoses were achieved through a questionnaire either by mail, telephone, interview or self-administered by the patient. There was a variation across papers regarding number and content of the questions as well as guidelines for the diagnosis of xerostomia (i.e. answer yes to one or more than one question). The prevalence of xerostomia in the selected articles ranged from 0.9% to 64.8%. The majority of these studies were performed in Scandinavia. In 9 of the articles, the studied samples were 50 years and older. None of the studies evaluated the prevalence xerostomia among individuals younger than 18 years. Based on these observations, it can be concluded that there is a need for population-based studies on prevalence of xerostomia in regions other than Scandinavia. A standardized protocol to diagnose xerostomia needs to be developed. Patient-perceived treatment needs and impact on quality of life should be included to have a complete picture of public health implications of the disease.


Assuntos
Saliva/metabolismo , Xerostomia/epidemiologia , Distribuição por Idade , Humanos , Prevalência , Distribuição por Sexo
14.
Int J Oral Maxillofac Surg ; 35(6): 481-7, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16567079

RESUMO

The aim of this study was to evaluate skeletal and dental changes after surgically assisted rapid maxillary expansion (SARME). Clinical trials were carried out that assessed skeletal and dental changes through cephalograms, computer tomographs or dental casts. No other simultaneous treatment during the active expansion period was accepted. Electronic databases (Pubmed, Medline, Medline In-Process & Other Non-Indexed Citations, All Evidence-based Medicine Reviews, Embase, Web of Science and Lilacs) were searched. Abstracts which appeared to fulfil the selection criteria were selected by consensus. The original articles were then retrieved and evaluated with a methodological checklist. Their references were hand searched for possible missing articles. Only 12 articles fulfilled the selection criteria. All presented methodological flaws. An individual methodological analysis of these articles was made. Expansion was greater at the molars and diminished progressively to the anterior part of the dental arch in all the evaluation periods. Vertical and sagittal skeletal changes were nil or not clinically significant. The nasal portion of the maxillary complex showed an increase in dimensions thereby improving nasal patency. An overall dental relapse of 0.5-1 mm is reported after 1 year of orthodontic treatment. The conclusions should be considered with caution because only a secondary level of evidence was found.


Assuntos
Ossos Faciais/patologia , Técnica de Expansão Palatina , Palato/cirurgia , Dente/patologia , Cefalometria , Arco Dental/patologia , Humanos , Maxila/patologia
15.
J Orthod ; 31(3): 204-9; discussion 201, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15489364

RESUMO

OBJECTIVE: To compare the aesthetic perception of different anterior visible occlusions in different facial and dental views (frontal view, lower facial third view and dental view) by lay persons. DESIGN: Cross-sectional survey, Lima, Peru, 2002. SUBJECTS: The different views were rated by 91 randomly selected adult lay persons. MAIN OUTCOME MEASUREMENT: Visual Analogue Scale (VAS) ratings of aesthetic perception of the views. RESULTS: Anterior visible occlusion, photographed subject and view (p<0.001) had a significant effect on the aesthetic ratings. Also gender (p=0.001) and the interaction between gender and level of education (p=0.046) had a significant effect over the aesthetic rating. CONCLUSIONS: A lay panel perceived that the aesthetic impact of the visible anterior occlusion was greater in a dental view compared with a full facial view. The anterior visible occlusion, photographed subject, view type are factors, which influence the aesthetic perception of smiles. In addition, gender and level of education had an influence.


Assuntos
Atitude Frente a Saúde , Estética Dentária , Face/anatomia & histologia , Sorriso , Adolescente , Adulto , Análise de Variância , Estudos Transversais , Oclusão Dentária , Escolaridade , Feminino , Humanos , Masculino , Má Oclusão/psicologia , Pessoa de Meia-Idade , Mordida Aberta/psicologia , Fotografia Dentária/classificação , Fatores Sexuais , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA