1.
Methods Mol Biol ; 2775: 225-237, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38758321

RESUMO

The polysaccharide capsule of Cryptococcus neoformans is the primary virulence factor and one of the most commonly studied aspects of this pathogenic yeast. Capsule size varies widely between strains, has the ability to grow rapidly when introduced to stressful or low-nutrient conditions, and has been positively correlated with strain virulence. For these reasons, the size of the capsule is of great interest to C. neoformans researchers. Inducing the growth of the C. neoformans capsule is used during phenotypic testing to help understand the effects of different treatments on the yeast or size differences between strains. Here, we describe one of the standard methods of capsule induction and detail two accepted methods of staining: (i) India ink, a negative stain, used in conjunction with conventional light microscopy and (ii) co-staining with fluorescent dyes of both the cell wall and capsule followed by confocal microscopy. Finally, we outline how to measure capsule diameter manually and offer a protocol for automated diameter measurement of India ink-stained samples using computational image analysis.


Assuntos
Cryptococcus neoformans , Coloração e Rotulagem , Cryptococcus neoformans/citologia , Coloração e Rotulagem/métodos , Microscopia Confocal/métodos , Parede Celular/metabolismo , Parede Celular/ultraestrutura , Cápsulas Fúngicas/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Corantes Fluorescentes/química , Carbono
2.
Nat Methods ; 19(5): 613-619, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35545715

RESUMO

Light-sheet microscopy has emerged as the preferred means for high-throughput volumetric imaging of cleared tissues. However, there is a need for a flexible system that can address imaging applications with varied requirements in terms of resolution, sample size, tissue-clearing protocol, and transparent sample-holder material. Here, we present a 'hybrid' system that combines a unique non-orthogonal dual-objective and conventional (orthogonal) open-top light-sheet (OTLS) architecture for versatile multi-scale volumetric imaging. We demonstrate efficient screening and targeted sub-micrometer imaging of sparse axons within an intact, cleared mouse brain. The same system enables high-throughput automated imaging of multiple specimens, as spotlighted by a quantitative multi-scale analysis of brain metastases. Compared with existing academic and commercial light-sheet microscopy systems, our hybrid OTLS system provides a unique combination of versatility and performance necessary to satisfy the diverse requirements of a growing number of cleared-tissue imaging applications.


Assuntos
Microscopia , Animais , Camundongos , Microscopia/métodos
3.
Nat Methods ; 18(6): 678-687, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34059829

RESUMO

We demonstrate residual channel attention networks (RCAN) for the restoration and enhancement of volumetric time-lapse (four-dimensional) fluorescence microscopy data. First we modify RCAN to handle image volumes, showing that our network enables denoising competitive with three other state-of-the-art neural networks. We use RCAN to restore noisy four-dimensional super-resolution data, enabling image capture of over tens of thousands of images (thousands of volumes) without apparent photobleaching. Second, using simulations we show that RCAN enables resolution enhancement equivalent to, or better than, other networks. Third, we exploit RCAN for denoising and resolution improvement in confocal microscopy, enabling ~2.5-fold lateral resolution enhancement using stimulated emission depletion microscopy ground truth. Fourth, we develop methods to improve spatial resolution in structured illumination microscopy using expansion microscopy data as ground truth, achieving improvements of ~1.9-fold laterally and ~3.6-fold axially. Finally, we characterize the limits of denoising and resolution enhancement, suggesting practical benchmarks for evaluation and further enhancement of network performance.


Assuntos
Microscopia de Fluorescência/métodos , Algoritmos , Aprendizado Profundo , Processamento de Imagem Assistida por Computador
4.
J Vis Exp ; (159)2020 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-32478717

RESUMO

Microtubules (MTs) play critical roles in neuronal development, but many questions remain about the molecular mechanisms of their regulation and function. Furthermore, despite progress in understanding postsynaptic MTs, much less is known about the contributions of presynaptic MTs to neuronal morphogenesis. In particular, studies of in vivo MT dynamics in Drosophila sensory dendrites yielded significant insights into polymer-level behavior. However, the technical and analytical challenges associated with live imaging of the fly neuromuscular junction (NMJ) have limited comparable studies of presynaptic MT dynamics. Moreover, while there are many highly effective software strategies for automated analysis of MT dynamics in vitro and ex vivo, in vivo data often necessitate significant operator input or entirely manual analysis due to inherently inferior signal-to-noise ratio in images and complex cellular morphology.  To address this, this study optimized a new software platform for automated and unbiased in vivo particle detection. Multiparametric analysis of live time-lapse confocal images of EB1-GFP labeled MTs was performed in both dendrites and the NMJ of Drosophila larvae and found striking differences in MT behaviors. MT dynamics were furthermore analyzed following knockdown of the MT-associated protein (MAP) dTACC, a key regulator of Drosophila synapse development, and identified statistically significant changes in MT dynamics compared to wild type. These results demonstrate that this novel strategy for the automated multiparametric analysis of both pre- and postsynaptic MT dynamics at the polymer-level significantly reduces human-in-the-loop criteria. The study furthermore shows the utility of this method in detecting distinct MT behaviors upon dTACC-knockdown, indicating a possible future application for functional screens of factors that regulate MT dynamics in vivo. Future applications of this method may also focus on elucidating cell type and/or compartment-specific MT behaviors, and multicolor correlative imaging of EB1-GFP with other cellular and subcellular markers of interest.


Assuntos
Dendritos/metabolismo , Drosophila melanogaster/metabolismo , Imageamento Tridimensional , Microtúbulos/metabolismo , Junção Neuromuscular/metabolismo , Imagem Individual de Molécula , Sinapses/metabolismo , Animais , Proteínas de Drosophila/metabolismo , Proteínas de Fluorescência Verde/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Larva/metabolismo , Proteínas Associadas aos Microtúbulos/metabolismo , Interferência de RNA , Software
5.
J Vis Exp ; (132)2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29553511

RESUMO

The polysaccharide capsule of Cryptococcus neoformans is the primary virulence factor and one of the most commonly studied aspects of this pathogenic yeast. Capsule size can vary widely between strains, has the ability to grow rapidly when introduced to stressful or low nutrient conditions, and has been positively correlated with strain virulence. For these reasons, the size of the capsule is of great interest to C. neoformans researchers. The growth of the C. neoformans capsule is induced during phenotypic testing to help understand the effects of different treatments on the yeast or size differences between strains. Here we describe one of the standard methods of capsule induction and compare two accepted methods of staining and measuring capsule diameter: (i) India ink, a negative stain, used in conjunction with conventional light microscopy and (ii) co-staining with fluorescent dyes of both the cell wall and capsule followed by confocal microscopy. Finally, we show how measurement of capsule diameter from India ink-stained samples can be automated using computational image analysis.


Assuntos
Parede Celular/metabolismo , Cryptococcus neoformans/crescimento & desenvolvimento
6.
Lab Chip ; 11(2): 336-42, 2011 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-20957288

RESUMO

In this paper, we present a monolithic PDMS micropump that generates peristaltic flow using a single control channel that actuates a group of different-sized microvalves. An elastomeric microvalve design with a raised seat, which improves bonding reliability, is incorporated into the micropump. Pump performance is evaluated based on several design parameters--size, number, and connection of successive microvalves along with control channel pressure at various operating frequencies. Flow rates ranging 0-5.87 µL min(-1) were observed. The micropump design demonstrated here represents a substantial reduction in the number of/real estate taken up by the control lines that are required to run a peristaltic pump, hence it should become a widespread tool for parallel fluid processing in high-throughput microfluidics.


Assuntos
Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentação , Desenho de Equipamento , Hidrodinâmica