RESUMO
OBJECTIVE: To demonstrate the potential of low-dose ultra-high-resolution CT (UHRCT) images to generate high-quality radiographic images on extremity phantoms and to estimate the radiation dose required for this. MATERIALS AND METHODS: A hand and knee phantom containing real human bones was imaged on an UHRCT scanner at full-dose, half-dose, and quarter-dose levels using a high-resolution extremity protocol. The raw data was reconstructed using both filtered back projection (FBP) and an iterative reconstruction algorithm (AIDR3D). Using custom designed software, each CT volume data set was converted to attenuation coefficients, and then a synthesized radiograph (synDX) was generated by forward projecting the volume data sets from a point source onto a 2D synthetic detector. The signal-to-noise ratio (SNR) was measured in the synDXs across all dose levels and the root-mean-squared error (RMSE) was computed with the FD synDXs as the reference. RESULTS: The proposed workflow generates high-quality synDXs at any arbitrary angle. For FBP, the SNR largely tracked with the radiation dose levels for both the knee and hand phantoms. For the knee phantom, iterative reconstruction provided a 6.1% higher SNR when compared to FBP. The RMSE was overall higher for the lowest dose levels and monotonically decreased with increasing dose. No substantial differences were observed qualitatively in the visualization of skeletal detail of the phantoms. CONCLUSION: The fine detail provided by UHRCT acquisitions of extremities facilitates the ability to generate quality radiographs, potentially eliminating the need for additional scanning on a conventional digital radiography system.
Assuntos
Algoritmos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Mãos/diagnóstico por imagemRESUMO
OBJECTIVE: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. METHODS: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. RESULTS: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6-40%. CONCLUSION: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: ⢠Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. ⢠The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. ⢠kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.
Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , AbdomeRESUMO
The liver and biliary tree are common sites of primary and secondary malignancies. MRI followed by CT is the mainstay for the imaging characterization of these malignancies with the dynamically acquired contrast enhanced phases being the most important for diagnosis. The liver imaging reporting and data system classification provides a useful framework for reporting lesions in patents with underlying cirrhosis or who are at high risk for developing hepatocellular carcinoma. Detection of metastases is improved with the use of liver specific MRI contrast agents and diffusion weighted sequences. Aside from hepatocellular carcinoma, which is often diagnosed noninvasively, other primary hepatobiliary tumors may require biopsy for definite diagnosis, especially when presenting with nonclassic imaging findings. In this review, we examine the imaging findings of common and less common hepatobiliary tumors.
Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Meios de Contraste , Imageamento por Ressonância Magnética/métodosAssuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Infusões Intra-Arteriais , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Artéria Hepática/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , FluoruracilaRESUMO
BACKGROUND: Colorectal cancer (CRC) is the second-leading cause of cancer-related death worldwide and resection of CRC metastases confined to the liver is the treatment of choice when feasible. Ferumoxytol is an off-label contrast agent that opacifies vasculature and may be helpful in distinguishing metastases from small hemangiomas and blood vessels on gadoxetic acid-enhanced magnetic resonance imaging (MRI). PURPOSE: To compare the diagnostic accuracy of MRI using a standard gadoxetic acid protocol and a combined gadoxetic acid/ferumoxytol protocol in patients with suspected colorectal hepatic metastases. MATERIAL AND METHODS: In this institutional review board-approved, single-institution, retrospective study, eight patients underwent gadoxetic acid-enhanced liver MRI, supplemented with additional T1-weighted ferumoxytol enhanced sequences. Two radiologists in consensus identified all metastases using all available sequences, which served as the reference standard. Two different radiologists reviewed each exam twice, once using the standard protocol and once with additional ferumoxytol sequences. The detection rate was estimated as the predicted probability of a metastasis along with the 95% confidence interval (CI) using hierarchical logistic regression models. RESULTS: A total of 49 metastases were identified. The mean diameter was 10 mm, measured in greatest axial dimension (median=7 mm; range=2-70 mm). Readers 1 and 2 had detection rates of 69.6% (95% CI = 48.2-85.0) and 53.1% (95% CI = 35.2-70.3) for gadoxetic acid alone and 98.0% (95% CI = 86.3-99.7) and 83.5% (95% CI = 59.3-94.7) for combined protocol. CONCLUSION: In this preliminary investigation, adding ferumoxytol-enhanced sequences to gadoxetic acid liver MRI protocol increased the detection rate of CRC hepatic metastases and may aid in preoperative decision making.
Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Óxido Ferroso-Férrico , Projetos Piloto , Estudos Retrospectivos , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Neoplasias Colorretais/patologiaRESUMO
ABSTRACT: The differential diagnosis for a uterine mass and vaginal bleeding after abortion or delivery is broad and includes both benign and malignant causes. A rare etiology for this condition is retained morbidly adherent placenta. Few cases of retained morbidly adherent placenta presenting as a myometrial mass in the setting of vaginal bleeding have been described in the medical literature. In this case series and review of the current literature, we describe the ultrasound features of 3 retained morbidly adherent placentae, along with correlative magnetic resonance imaging findings.
Assuntos
Placenta Acreta , Doenças Placentárias , Feminino , Humanos , Gravidez , Imageamento por Ressonância Magnética , Placenta , Placenta Acreta/diagnóstico por imagem , Placenta Acreta/etiologia , Hemorragia Uterina/etiologia , Hemorragia Uterina/complicaçõesRESUMO
Incidental pancreatic cysts are commonly encountered in radiology practice. Although some of these are benign, mucinous varieties have a potential to undergo malignant transformation. Characterization of some incidental pancreatic cysts based on imaging alone is limited, and given that some pancreatic cysts have a malignant potential, various societies have created guidelines for the management and follow-up of incidental pancreatic cysts. This article reviews the imaging findings and work-up of pancreatic cysts and gives an overview of the societal guidelines for the management and follow-up of incidental pancreatic cysts.
Assuntos
Diagnóstico por Imagem/métodos , Achados Incidentais , Cisto Pancreático/diagnóstico por imagem , Humanos , Pâncreas/diagnóstico por imagemRESUMO
BACKGROUND: To determine the relationship between adipose tissue and skeletal muscle measurements on computed tomography (CT) and overall survival and major postoperative complications in patients with soft-tissue sarcoma (STS). METHODS: The retrospective study included 137 STS patients (75 men, 62 women; mean age, 53 years, SD 17.7; mean BMI, 28.5, SD 6.6) who had abdominal CT exams. On a single CT image, at the L4 pedicle level, measurements of visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), and skeletal muscle area and attenuation were obtained using clinical PACS and specialized segmentation software. Clinical information was recorded, including STS characteristics (size, depth, grade, stage, and site), overall survival, and postoperative complications. The relationships between CT metrics and survival were analyzed using Cox proportional hazard models and those between CT metrics and postoperative complications using logistic regression models. RESULTS: There were 33 deaths and 41 major postoperative complications. Measured on clinical PACS, the psoas area (P=0.003), psoas index (P=0.006), psoas attenuation (P=0.011), and total muscle attenuation (P=0.023) were associated with overall survival. Using specialized software, psoas attenuation was also associated with overall survival (P=0.018). Adipose tissue metrics were not associated with survival or postoperative complications. CONCLUSIONS: In STS patients, CT-derived muscle size and attenuation are associated with overall survival. These prognostic biomarkers can be obtained using specialized segmentation software or routine clinical PACS.
RESUMO
OBJECTIVE. The purpose of this article is to present strategies and guidelines that can be implemented in the performance of cross-sectional interventional procedures during the coronavirus disease (COVID-19) pandemic. CONCLUSION. Radiologists who perform cross-sectional interventional procedures can take several steps to minimize the risks to patients and radiology personnel, including screening referred patients to decide which procedures can be postponed, using appropriate personal protective equipment (PPE), minimizing the number of people involved in procedures, preserving PPE when possible, and applying proper room and equipment cleaning measures.
Assuntos
COVID-19/prevenção & controle , Controle de Infecções/normas , Radiografia Intervencionista/normas , Serviço Hospitalar de Radiologia/normas , COVID-19/epidemiologia , Guias como Assunto , Humanos , Pandemias , Seleção de Pacientes , Equipamento de Proteção Individual , SARS-CoV-2 , Estados Unidos/epidemiologiaRESUMO
OBJECTIVE. The objective of our study was to investigate the significance of sonographic features in assessing for acute kidney allograft rejection in the modern era. MATERIALS AND METHODS. In this retrospective study, 107 adult patients with a kidney allograft biopsy performed between 2015 and 2018 and diagnostic ultrasound performed within 2 weeks of the biopsy were included. Acute rejection was diagnosed on the basis of biopsy tissue sample results using the Banff criteria. The following ultrasound features were assessed: perfusion, cortical echogenicity, corticomedullary differentiation, urothelial thickening, change in renal length, renal artery velocity, and intraparenchymal arterial resistive index. Subjective measures of perfusion, echogenicity, corticomedullary differentiation, and urothelial thickening were assessed independently and in consensus by three abdominal radiologists; multirater kappa values were calculated for interobserver variability. The Wilcoxon rank sum test and chi-square test were used to evaluate the differences between two groups (rejection vs no rejection) and the sonographic features. Sensitivity, specificity, positive predictive value, and negative predictive value (NPV) were calculated for sonographic features that are associated with acute rejection. RESULTS. Of the sonographic features, only the presence of urothelial thickening was significantly associated with acute rejection (p < 0.001) and had substantial agreement (κ = 0.61) among readers. Urothelial thickening was highly sensitive (96%; 95% CI, 79-100%) with a high NPV (98%; 95% CI, 86-100%). CONCLUSION. Urothelial thickening on ultrasound is a highly sensitive finding for acute kidney rejection with a high NPV and thus may play a role in sonographic prebiopsy screening. Other historically associated sonographic features seem to play little, if any, role in the screening and assessment for kidney allograft rejection in the modern era.
Assuntos
Rejeição de Enxerto/diagnóstico por imagem , Transplante de Rim , Ultrassonografia/métodos , Urotélio/diagnóstico por imagem , Urotélio/patologia , Adulto , Idoso , Aloenxertos , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE. The purpose of this study is to identify the landmarks and associated radiation dose reduction for limited CT of the kidneys of patients requiring follow-up for known nephrolithiasis. MATERIALS AND METHODS. This retrospective study included all adult patients who underwent CT examination type "CT abdomen + pelvis renal stone" at our institution during 2017. Several exclusion criteria were identified, including scoliosis and congenital renal abnormalities. A total of 299 patients met the inclusion and exclusion criteria. The radiation dose and z-axis length associated with the original CT scan were recorded. The upper and lower limits of both kidneys in relation to the vertebral body endplates were recorded, to determine the z-axis length for a CT scan limited to the kidneys. A commercially available radiation dose analytics software package was used to provide estimates of whole-body-and individual organ-equivalent doses for the original CT scan and the limited range CT scan. RESULTS. The superior endplate of T11 and the inferior endplate of L5 are landmarks that will include both kidneys on almost all scans. A limited z-axis range leads to a mean scan length reduction of 50%. The whole-body mean effective dose is reduced by 41.5%, and the doses to the breast and the gonadal and bladder organs are reduced by 71.7%, 73.8%, and 81.8%, respectively. CONCLUSION. For patients without symptoms who are undergoing CT surveillance to evaluate renal calculi growth, new stone formation, or both, a limited-range scan extending from the superior endplate of T11 to the inferior endplate of L5 results in a significant reduction in radiation dose.
RESUMO
PURPOSE: While pelvic congestion syndrome and chronic pelvic pain are relatively common in women, no large- or medium-sized studies have been conducted to our knowledge to evaluate the frequency and severity of ovarian vein dilatation (OVD) on computed tomography (CT). The purpose of our study was therefore to analyze a large number of consecutive abdominal and pelvic CT scans in adult women to determine OVD frequency and severity. METHODS: An IRB-approved, single-institution retrospective analysis of 1042 consecutive abdominal and pelvic CT scans in women ages 25-65 was performed. Scans were evaluated for the presence and severity of OVD and association with "nutcracker anatomy." A gradation scheme was developed based on quartile analysis. RESULTS: 143 of the CT scans had OVD (13.7%). Of the positive scans, 96 were bilateral, 29 were left-side only, 18 were right-side only, and 18 had nutcracker-type compression of the left renal vein (14.4% of scans with left or bilateral OVD). In positive scans, the mean and median left OVD were 7.5 and 7 mm, respectively, and right-side were 7.2 and 7 mm, respectively. Based on quartile analysis, OVD grading was mild (< 6 mm), moderate (6-8 mm), or severe (> 8 mm), with moderate including the middle 50% of patients. CONCLUSIONS: OVD was found on 13.7% of 1042 consecutive female abdominal and pelvic CT scans, with "nutcracker anatomy" present in 14.4% of the scans with left OVD. Moderate dilatation was defined as an OVD of 6-8 mm at the iliac crests.
Assuntos
Doenças Ovarianas/diagnóstico por imagem , Ovário/irrigação sanguínea , Ovário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doenças Vasculares/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de DoençaRESUMO
OBJECTIVE: The purpose of this study was to determine the prevalence of solid tumors in incidental homogeneous renal masses with attenuation greater than 20 HU on portal venous phase CT images. MATERIALS AND METHODS: In this retrospective study, the records of patients with incidental indeterminate (> 20 HU) homogeneous renal masses on portal venous phase CT scans from September 11, 2007, through March 18, 2017, were identified. Adult patients were included if they had undergone follow-up ultrasound, contrast-enhanced MRI, multiphase contrast-enhanced CT, or pathologic analysis alone to confirm the solid or cystic nature of the lesion. A single ROI was placed in the center of the mass, and lesions were characterized as ≥ 50% exophytic, < 50% exophytic, or entirely surrounded by renal parenchyma. RESULTS: There were 322 masses in 267 patients. The mean lesion size was 16.6 (SD, 9.8) mm (range, 9-45 mm). Lesions were ≥ 50% exophytic in 92 cases, < 50% exophytic in 111 cases, and completely surrounded by renal parenchyma in 119 cases. All nonsolid lesions were characterized as benign cysts. The numbers of solid lesions per total number of lesions in each attenuation group were: 20-30 HU (0/140), 30-40 HU (0/67), 40-50 HU (1/38), 50-60 HU (3/24), 60-70 HU (5/17), 70-80 HU (5/17), and > 80 HU (8/19). All 207 lesions in the 20- to 40-HU range were benign cysts with no solid lesions (0%; 95% CI, 0.0-1.4%). CONCLUSION: Small homogeneous renal masses measuring 20-40 HU on portal venous phase CT images are highly likely to be benign cysts.
Assuntos
Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Neoplasias Renais/epidemiologia , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prevalência , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos RetrospectivosRESUMO
PURPOSE: To determine normal bladder wall thickness on CT in patients without bladder disease. MATERIALS AND METHODS: Four hundred and nineteen patients presenting for trauma with normal CTs of the abdomen and pelvis were included in our retrospective study. Bladder wall thickness was assessed, and bladder volume was measured using both the ellipsoid formula and an automated technique. Patient age, gender, and body mass index were recorded. Linear regression models were created to account for bladder volume, age, gender, and body mass index, and the multiple correlation coefficient with bladder wall thickness was computed. Bladder volume and bladder wall thickness were log-transformed to achieve approximate normality and homogeneity of variance. Variables that did not contribute substantively to the model were excluded, and a parsimonious model was created and the multiple correlation coefficient was calculated. Expected bladder wall thickness was estimated for different bladder volumes, and 1.96 standard deviation above expected provided the upper limit of normal on the log scale. RESULTS: Age, gender, and bladder volume were associated with bladder wall thickness (p = 0.049, 0.024, and < 0.001, respectively). The linear regression model had an R2 of 0.52. Age and gender were negligible in contribution to the model, and a parsimonious model using only volume was created for both the ellipsoid and automated volumes (R2 = 0.52 and 0.51, respectively). CONCLUSION: Bladder wall thickness correlates with bladder wall volume. The study provides reference bladder wall thicknesses on CT utilizing both the ellipsoid formula and automated bladder volumes.
Assuntos
Tomografia Computadorizada por Raios X , Bexiga Urinária/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos RetrospectivosRESUMO
OBJECTIVE: The purpose of this study was to determine the rate of malignancy in incidentally detected bilateral adrenal masses in patients with no known history of cancer. MATERIALS AND METHODS: A retrospective search of CT reports of patients with incidentally detected bilateral adrenal nodules was performed from January 1, 2002, to January 1, 2014. Patients were excluded if they had a known cancer or suspected functioning adrenal tumor; 161 patients were included. Nodules were characterized as benign or malignant on the basis of imaging features at the index CT examination, imaging features at subsequent adrenal protocol CT or MRI, imaging stability for a minimum of 1 year, or clinical follow-up of a minimum of 2 years. RESULTS: Mean nodule size was 1.8 cm (range, 0.7-4.9 cm). There were no cases of primary or secondary adrenal malignancy (95% CI, 0.00-0.023). The nodules diagnosed on index CT scans were 73 adrenal adenomas and two myelolipomas. Seventy-four nodules were subsequently characterized as adrenal adenomas on the basis of imaging findings. Of the 113 indeterminate nodules that had imaging follow-up, 111 were stable at the latest follow-up examination. One nodule grew 26% over 8.1 years, and the other grew 59% over 12.4 years. Clinical follow-up of patients with 60 indeterminate nodules revealed no evidence of adrenal malignancy. CONCLUSION: No case of malignancy was found in 322 incidentally detected bilateral adrenal nodules at CT of patients without known cancer. Imaging follow-up of such lesions may be unnecessary.
Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico por imagem , Doenças das Glândulas Suprarrenais/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Achados Incidentais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: The purpose of this article is to determine the accuracy and radiation dose reduction of limited-range CT prescribed from the top of L2 to the top of the pubic symphysis in children with suspected acute appendicitis. MATERIALS AND METHODS: We performed a retrospective study of 210 consecutive pediatric patients from December 11, 2012, through December 11, 2014, who underwent abdominopelvic CT for suspected acute appendicitis. Two radiologists independently reviewed the theoretic limited scans from the superior L2 vertebral body to the top of the pubic symphysis, to assess for visualization of the appendix, acute appendicitis, alternative diagnoses, and incidental findings. Separately, the same parameters were assessed on the full scan by the same two reviewers. Whole-body effective doses were determined for the full- and limited-range scans and were compared using the paired t test. RESULTS: The appendix or entire cecum was visualized on the limited scan in all cases, and no cases of acute appendicitis were missed on the simulated limited scan compared with the full scan. Two alternative diagnoses were missed with the limited scan: one case of hydronephrosis and one of acute acalculous cholecystitis. The mean effective dose for the original scan was 5.6 mSv and that for the simulated limited scan was 3.0 mSv, resulting in a dose reduction of 46.4% (p < 0.001). CONCLUSION: A limited-range CT examination performed from the top of L2 to the top of the pubic symphysis is as accurate as a full-range abdominopelvic CT in evaluating pediatric patients with suspected appendicitis and reduces the dose by approximately 46%.
Assuntos
Apendicite/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Achados Incidentais , Masculino , Estudos RetrospectivosRESUMO
To describe the reasons and additional radiation for CT scans repeated after transfer to a trauma center. Retrospective study of patients transferred to a trauma center. Patients had repeat CT if a CT of the same region was repeated at the trauma center's emergency department. Indications for repeat CT scanning were abstracted. Radiation dosage was calculated in millisieverts. A total of 370 had CT scans and were transferred. Mean age was 39.1 ± 28.0 years. Seventy-four [20.0%, 95% confidence interval (CI) 16.0-24.4%] had 103 CTs repeated. Adults (64/254, 25.2%) were more likely than children (10/116, 8.6%) to undergo repeat CT (difference 16.6%, 95% CI 9.2-24.0%). Types of CTs repeated included: head 48 (47%), face 6 (6%), cervical spine/neck 21 (20%), thoracolumbar spine 4 (4%), chest 4 (4%), and abdominal/pelvic 20 (19%). Reasons for repeat CT were outside CT unavailable 31 (42%), insufficient image quality/additional details needed 15 (20%), disease progression 16 (22%), unknown 10 (14%), and consult request unknown reason 2 (3%). Median dose for the repeat CT scans was 4.19 mSv (interquartile range 1.98, 6.28) and was 4.79 mSv (interquartile range 2.47, 8.22) when the CTs were unavailable. Effective dose of the repeat scans was greater than 10 mSv in 13 (3.5%) patients. Patients transferred to a trauma center often undergo repeat CT. The most common reason for repeated imaging was failure to transport original CT scans with the patient or images that were unable to be viewed. Trauma centers should work with their catchment areas to establish systems that ensure transfer of all radiographic imaging.
Assuntos
Seleção de Pacientes , Transferência de Pacientes , Tomografia Computadorizada por Raios X , Centros de Traumatologia , Ferimentos e Lesões/diagnóstico por imagem , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Adulto JovemRESUMO
BACKGROUND: The alignment of the lower extremity has important implications in the development of knee arthritis. The effect of incremental rotations of the limb on common parameters of alignment has not been studied. The purpose of the study was to (1) determine the standardized neutral position measurements of alignment and (2) determine the effect of rotation on commonly used measurements of alignment. METHODS: Eighty-seven full length CT angiography studies (49 males and 38 females, average age 66 years old) were included. Three-dimensional models were created using a rendering software program and placed on a virtual plane. An image of the extremity was obtained. Thirty scans were randomly selected, and those models were rotated in 3° intervals around the longitudinal axis and additional images were obtained. RESULTS: In the neutral position, the mechanical lateral distal femoral articular angle (mLDFA) was 85.6 ± 2.3°, medial proximal tibial angle (MPTA) was 86.1 ± 2.8°, and mechanical tibiofemoral angle (mTFA) was -0.7 ± 3.1°. Females had a more valgus alignment with a mTFA of 0.5 ± 2.9° while males had a more varus alignment with a mTFA of -1.7 ± 2.9°. The anatomic tibiofemoral angle (aTFA) was 4.8 ± 2.6°, the anatomic lateral distal femoral angle (aLDFA) measured 80.2 ± 2.2°, and the anatomical-mechanical angle (AMA) was 5.4 ± 0.7°. The prevalence of constitutional varus was 18%. The effect of rotation on the rotated scans led to statistically significant differences relative to the 0° measurement for all measurements. These effects may be small, and their clinical importance is unknown. CONCLUSIONS: This study provides new information on standardized measures of lower extremity alignment and the relationship between discreet axial rotations of the entire lower extremity and these parameters.
Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Extremidade Inferior/anatomia & histologia , Rotação , Adulto , Idoso , Idoso de 80 Anos ou mais , Mau Alinhamento Ósseo/patologia , Feminino , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Caracteres Sexuais , Tíbia/anatomia & histologia , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios XRESUMO
Importance: Radiation doses for computed tomography (CT) vary substantially across institutions. Objective: To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. Design, Setting, and Participants: In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. Main Outcomes and Measures: We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Results: Of 158â¯274 diagnostic CT scans performed in the study period, 29â¯594 CT scans were performed in the 3 months before and 32â¯839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After the audit and meeting, head CT doses varied less, although some institutions increased and some decreased mean head CT doses and the proportion above benchmarks. Conclusions and Relevance: Reviewing institutional doses and sharing dose-optimization best practices resulted in lower radiation doses for chest and abdominal CT and more consistent doses for head CT.
Assuntos
Radiografia Abdominal/normas , Radiografia Torácica/normas , Tomografia Computadorizada por Raios X/normas , California , Relação Dose-Resposta à Radiação , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Neoplasias Induzidas por Radiação/prevenção & controle , Pelve/diagnóstico por imagem , Doses de Radiação , Medição de Risco , Tomografia Computadorizada por Raios X/efeitos adversosRESUMO
OBJECTIVE: The purpose of our study was to determine the current practice patterns of U.S. radiologists in imaging pregnant or potentially pregnant patients with acute abdominal and pelvic conditions. MATERIALS AND METHODS: After obtaining an Institutional Review Board waiver, all members of the Association of University Radiologists, the Association of Program Directors in Radiology, and the Society of Radiologists in Ultrasound were invited via e-mail to take a 23-question online survey on radiology practices and clinical scenarios about acute abdominal and pelvic imaging of pregnant patients. RESULTS: Comparisons were made with previously published surveys. A total of 225 responses were received. Areas of high consensus included pregnancy assessment (97%) and obtaining informed consent (87%) before imaging, having a written policy on imaging pregnant patients (79%), modification of computed tomography (CT) protocols (74%), avoiding gadolinium contrast in magnetic resonance imaging (MRI) (74%), using ultrasound for initial imaging in some scenarios, and using CT in trauma cases after inconclusive ultrasound. Areas of emerging consensus compared to 2007 included the use of serum or urine testing to confirm pregnancy status (59.4%; previously 14%) and the use of MRI in suspected appendicitis after an inconclusive ultrasound (73% in first trimester and 67% in third trimester; previously 46% and 29%, respectively). Areas without clear consensus included policy development, additional modifications to MRI protocols, choice of imaging modality, radiation dose, and the use of contrast agents in some scenarios. CONCLUSION: In conclusion, high or increasing consensus exists in some areas of imaging pregnant patients with acute abdominal and pelvic conditions, but has yet to emerge in other areas.