1.
Clin Radiol ; 65(9): 744-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20696302

RESUMO

This paper describes how to perform duplex sonography in the planning and evaluation of arteriovenous fistulae in haemodialysis patients, discusses its roles in these settings, and presents a review of commonly encountered complications.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal , Ultrassonografia Doppler Dupla/métodos , Artérias/diagnóstico por imagem , Derivação Arteriovenosa Cirúrgica/métodos , Humanos
2.
Int J Sports Med ; 22(4): 245-9, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11414664

RESUMO

This study examines the reproducibility of gastro-intestinal blood flow measurements in the superior mesenteric artery (SMA) both before and immediately after exercise with Doppler ultrasound measurements. Twelve well-trained males (mean +/- SD: age 25.9 +/- 3.8 yr; VO2max 4.8 +/- 0.91 x min(-1)) were measured twice (trial 1 and 2) with a 1 week interval before and immediately after 1 hr cycling at 70% VO2max. Duplex scanning was performed with the athletes in supine position immediately after transition from a chair (before exercise) or bicycle (after exercise). The variability of three measurements before exercise was studied within both trials (short-term reproducibility) and the mean pre-exercise values were compared between the trials (long-term reproducibility). In addition, post-exercise measurements were compared in the same way. Reproducibility was tested using the coefficient of variation and Cronbach's alpha. Mean pre-exercise blood flow was 424 +/- 66 ml/min (n = 12) in trial 1 and 375 +/- 38 ml/min (n = 11) in trial 2. Immediately after exercise blood flow had decreased by 49% to 214 +/- 36 ml/min (p <0.01) in trial 1 and by 38% to 234 +/- 36 ml/min (p < 0.01) in trial 2. Blood flow before and after exercise was not significantly different between trials (paired t-test) and therefore reproducible at the group level. Before exercise a good to fair reproducibility was observed both at the short-term (Cronbach's alpha: 0.88 in trial 1, 0.73 in trial 2, n = 11), and at the long-term (alpha = 0.80, n= 11). In contrast, long-term reproducibility immediately after exercise was poor (alpha = -0.99, n = 8 and alpha = 0.36, n = 7 after the first and second cycling period, respectively). In conclusion, duplex scanning of SMA after a sitting-supine transition in well-trained subjects is not a reproducible method at the individual level for intestinal blood flow measurements immediately after exercise.


Assuntos
Exercício Físico/fisiologia , Artéria Mesentérica Superior/fisiologia , Adulto , Coleta de Dados , Teste de Esforço , Humanos , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Esportes , Ultrassonografia