Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Vet Res ; 20(1): 48, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317167

RESUMO

BACKGROUND: Bronchoalveolar lavage (BAL) is a diagnostic method for the assessment of the lower respiratory airway health status in horses. Differential cell count and sometimes also total nucleated cell count (TNCC) are routinely measured by time-consuming manual methods, while faster automated methods exist. The aims of this study were to compare: 1) the Sysmex XN-V body fluid (BF) mode with the manual techniques for TNCC and two-part differential into mononuclear and polymorphonuclear cells; 2) the Olympus VS200 slide scanner and software generated deep-learning-based algorithm with manual techniques for four-part differential cell count into alveolar macrophages, lymphocytes, neutrophils, and mast cells. The methods were compared in 69 clinical BAL samples. RESULTS: Incorrect gating by the Sysmex BF mode was observed on many scattergrams, therefore all samples were reanalyzed with manually set gates. For the TNCC, a proportional and systematic bias with a correlation of r = 0.79 was seen when comparing the Sysmex BF mode with manual methods. For the two-part differential count, a mild constant and proportional bias and a very small mean difference with moderate limits of agreement with a correlation of r = 0.84 and 0.83 were seen when comparing the Sysmex BF mode with manual methods. The Sysmex BF mode classified significantly more samples as abnormal based on the TNCC and the two-part differential compared to the manual method. When comparing the Olympus VS200 deep-learning-based algorithm with manual methods for the four-part differential cell count, a very small bias in the regression analysis and a very small mean difference in the difference plot, as well as a correlation of r = 0.85 to 0.92 were observed for all four cell categories. The Olympus VS200 deep-learning-based algorithm also showed better precision than manual methods for the four-part differential cell count, especially with an increasing number of analyzed cells. CONCLUSIONS: The Sysmex XN-V BF mode can be used for TNCC and two-part differential count measurements after reanalyzing the samples with manually set gates. The Olympus VS200 deep-learning-based algorithm correlates well with the manual methods, while showing better precision and can be used for a four-part differential cell count.


Assuntos
Líquidos Corporais , Aprendizado Profundo , Animais , Cavalos , Contagem de Células/veterinária , Linfócitos , Algoritmos , Contagem de Leucócitos/veterinária , Reprodutibilidade dos Testes
2.
BMC Vet Res ; 20(1): 21, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200552

RESUMO

BACKGROUND: Acidification of equine urine to promote dissociation of ion complexes is a common practice for urine ion concentration measurements. The objective of this study was to evaluate the effect of acidification and storage after acidification on calcium (Ca), magnesium (Mg) and phosphate (P) concentrations and on fractional excretion (FE) of these electrolytes. Thirty-two fresh equine urine samples were analysed between December 2016 and July 2020. Complete urinalysis (stick and sediment) was performed on all samples. Ca, Mg, P and creatinine concentrations were measured in supernatant of centrifuged native urine, urine directly centrifuged after acidification and urine centrifuged 1 hour after acidification. Urine was acidified with hydrochloric acid to reach a pH of 1-2. Ca, Mg, P and creatinine concentrations were also measured in blood plasma, and fractional excretion of each electrolyte was calculated. Equality of medians was tested with Friedman tests and Bland-Altman bias plots were used to show the agreement between conditions. RESULTS: Acidification had a statistically significant effect on Ca and Mg concentrations, FECa and FEMg. Bland-Altman plot revealed a strong positive proportional bias between Ca concentration in native and acidified urine with a mean bias of 17.6 mmol/l. For Mg concentration, the difference between native and acidified urine was small with a mean bias of 1.8 mmol/l. The increase in FECa was clinically relevant. Storage of acidified urine had no effect on any of the measured ion concentrations. All P concentrations in native urine samples were below the detection limit of the assay and statistical analysis and calculation of FEP was not possible. CONCLUSIONS: Urine acidification is essential for accurate measurement of Ca and Mg concentrations and therefore FE calculations in equine urine. Storage time of 1 hour after acidification does not significantly change Ca and Mg concentrations.


Assuntos
Líquidos Corporais , Cálcio , Animais , Cavalos , Magnésio , Creatinina , Concentração de Íons de Hidrogênio
3.
Animals (Basel) ; 13(11)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889764

RESUMO

Fibroblast growth factor-23 (FGF-23) is a phosphaturic hormone used to monitor chronic kidney disease (CKD) in humans. The aim of this pilot study was to compare three diagnostic assays and to assess how the results correlate with parameters of renal dysfunction in cats. Four groups of 10 cats each were formed retrospectively according to creatinine, based on IRIS staging. FGF-23 was measured using two different ELISAs (MyBioSource and Kainos ELISA FGF-23 Kit) and an automated assay on the DiaSorin Liaison platform. Measurements were performed in 40 cats. Spearman's rank correlation coefficient showed a strong correlation between the Kainos and DiaSorin assays (ρ = 0.742/p < 0.001) and a low correlation (ρ = 0.443/p = 0.005) between the Kainos and MyBioSource assays. The measurements with the Kainos assay strongly correlated with urea (ρ = 0.835/p < 0.001) and creatinine (ρ = 0.764/p < 0.001), and moderately correlated with SDMA (ρ = 0.580/p < 0.001) and phosphorus (ρ = 0.532/p < 0.001). The results of the MyBioSource and DiaSorin assays only showed a moderate correlation with urea (ρ = 0.624/0.572) and creatinine (ρ = 0.622/0.510) concentrations (p = 0.001 each). The Kainos assay showed the strongest correlation (ρ = 0.806) with the various creatinine concentrations according to the IRIS, followed by the MyBioSource (ρ = 0.663/p < 0.001) and DiaSorin assays (ρ = 0.580/p < 0.001). Overall, the Kainos assay demonstrated the best correlations with both biomarkers and various creatinine concentrations according to the IRIS. Individual assay-based reference values should be established to make a reliable interpretation of FGF-23 levels possible to diagnose or monitor feline CKD.

4.
Animals (Basel) ; 13(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37893926

RESUMO

Fibroblast growth factor-23 (FGF-23) is a phosphaturic hormone used to monitor chronic kidney disease (CKD) in humans. The aims of this study were (1) to determine the intra- and interassay precision of the FGF-23 concentrations in dogs as measured via the Kainos ELISA FGF-23 kit, (2) to calculate a reference interval, and (3) to assess the correlation of the FGF-23 concentration with the hematological and biochemical parameters. The coefficient of variation was below 15% for both the intra- and interassay precision, indicating good reproducibility. The reference interval ranged between 95.8 (90% confidence interval: 44.6; 139.2) and 695.1 pg/mL (598.7; 799.1) based on 136 clinically healthy dogs, classified as such according to the information of treating veterinarians as well as the unremarkable results of hematology and biochemistry. The FGF-23 concentration differed significantly between dogs aged <9 and ≥9 years (p = 0.045). Four groups of 10 dogs each were retrospectively formed based on the creatinine concentration classification according to the IRIS staging. Correlation was the strongest for the renal parameters. Statistically significant differences in the FGF-23 concentration were demonstrated between the study groups I and III (p < 0.001), I and IV (p < 0.001), and II and IV (p = 0.005). There was a trend for a rising FGF-23 concentration in older dogs. Due to the wide reference interval, diagnostic cut-offs and/or subject-based FGF-23 reference values in each dog are needed for monitoring and clinical interpretation.

5.
Cells ; 12(7)2023 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-37048064

RESUMO

Methemoglobinemia is an acquired or inherited condition resulting from oxidative stress or dysfunction of the NADH-cytochrome b5 reductase or associated pathways. This study describes the clinical, pathophysiological, and molecular genetic features of a cat with hereditary methemoglobinemia. Whole genome sequencing and mRNA transcript analyses were performed in affected and control cats. Co-oximetry, ektacytometry, Ellman's assay for reduced glutathione concentrations, and CYB5R activity were assessed. A young adult European domestic shorthair cat decompensated at induction of anesthesia and was found to have persistent methemoglobinemia of 39 ± 8% (reference range < 3%) of total hemoglobin which could be reversed upon intravenous methylene blue injection. The erythrocytic CYB5R activity was 20 ± 6% of normal. Genetic analyses revealed a single homozygous base exchange at the beginning of intron 3 of the CYB5R3 gene, c.226+5G>A. Subsequent mRNA studies confirmed a splice defect and demonstrated expression of two mutant CYB5R3 transcripts. Erythrocytic glutathione levels were twice that of controls. Mild microcytosis, echinocytes, and multiple Ca2+-filled vesicles were found in the affected cat. Erythrocytes were unstable at high osmolarities although highly deformable as follows from the changes in elongation index and maximal-tolerated osmolarity. Clinicopathological presentation of this cat was similar to other cats with CYB5R3 deficiency. We found that methemoglobinemia is associated with an increase in red blood cell fragility and deformability, glutathione overload, and morphological alterations typical for stress erythropoiesis.


Assuntos
Metemoglobinemia , Gatos , Animais , Metemoglobinemia/genética , Metemoglobinemia/tratamento farmacológico , Metemoglobinemia/veterinária , Eritrócitos , Azul de Metileno , RNA Mensageiro/uso terapêutico , Glutationa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA