Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Neuroophthalmology ; 37(4): 146-156, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-28167978

RESUMO

Chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) can lead to prominent nerve hypertrophy, which can mimic other forms of neuropathy radiologically. Neuro-ophthalmological complications can also occur in CIDP, either at presentation or chronically in the disorder. This can also cause diagnostic difficulties. We report three cases of neuro-ophthalmological complications of CIDP: two cases of papilloedema and one case of proptosis. In all three cases cranial nerve hypertrophy was present. CIDP should be considered in neuro-ophthalmological presentations associated with cranial/spinal nerve root hypertrophy.

2.
Can J Neurol Sci ; 32(3): 327-31, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16225174

RESUMO

INTRODUCTION: Doppler ultrasound (DUS) is used as a screening tool to assess internal carotid artery (ICA) disease. Recent reports suggest that the DUS may be inaccurate in over 28% of patients. We sought to evaluate the accuracy of DUS, when performed in a dedicated stroke prevention clinic (SPC). METHODS: We retrospectively reviewed the charts of patients who had a DUS performed in our SPC, followed by conventional cerebral angiography. Three groups of patients were defined. Group 1 had DUS measured ICA stenosis of >50%; Group II had a DUS measured ICA stenosis of <50%; Group III had complete ICA occlusion on DUS. RESULTS: Sixty-seven patients (69 arteries) were included in the study. There were 45 patients in Group I and based on the findings of cerebral angiography, carotid endarterectomy was considered inappropriate in only one patient--a misclassification rate of 2.2% (95% CI: 0 - 6.5%). Group II consisted of 19 patients and on cerebral angiography, none of these patients had a stenosis of >50%--a misclassification rate of 0%. Group III consisted of five patients in whom DUS showed complete ICA occlusion. The angiogram confirmed the occlusion in all five patients--a misclassification rate of 0%. Overall, misclassification rate was 1.45% (95% CI: 0 - 4.3%). CONCLUSIONS: Doppler ultrasound when performed in a stroke prevention clinic (SPC), has a high accuracy in measuring ICA stenosis of >50%. Doppler ultrasound is reliable in detecting complete ICA occlusion and finally DUS is a reliable screening tool to rule out clinically significant ICA stenosis.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Idoso , Angiografia Cerebral , Erros de Diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ambulatório Hospitalar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA