Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Radiology ; 308(3): e231236, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750768

RESUMO

Background Commercially available artificial intelligence (AI) tools can assist radiologists in interpreting chest radiographs, but their real-life diagnostic accuracy remains unclear. Purpose To evaluate the diagnostic accuracy of four commercially available AI tools for detection of airspace disease, pneumothorax, and pleural effusion on chest radiographs. Materials and Methods This retrospective study included consecutive adult patients who underwent chest radiography at one of four Danish hospitals in January 2020. Two thoracic radiologists (or three, in cases of disagreement) who had access to all previous and future imaging labeled chest radiographs independently for the reference standard. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated. Sensitivity and specificity were additionally stratified according to the severity of findings, number of findings on chest radiographs, and radiographic projection. The χ2 and McNemar tests were used for comparisons. Results The data set comprised 2040 patients (median age, 72 years [IQR, 58-81 years]; 1033 female), of whom 669 (32.8%) had target findings. The AI tools demonstrated areas under the receiver operating characteristic curve ranging 0.83-0.88 for airspace disease, 0.89-0.97 for pneumothorax, and 0.94-0.97 for pleural effusion. Sensitivities ranged 72%-91% for airspace disease, 63%-90% for pneumothorax, and 62%-95% for pleural effusion. Negative predictive values ranged 92%-100% for all target findings. In airspace disease, pneumothorax, and pleural effusion, specificity was high for chest radiographs with normal or single findings (range, 85%-96%, 99%-100%, and 95%-100%, respectively) and markedly lower for chest radiographs with four or more findings (range, 27%-69%, 96%-99%, 65%-92%, respectively) (P < .001). AI sensitivity was lower for vague airspace disease (range, 33%-61%) and small pneumothorax or pleural effusion (range, 9%-94%) compared with larger findings (range, 81%-100%; P value range, > .99 to < .001). Conclusion Current-generation AI tools showed moderate to high sensitivity for detecting airspace disease, pneumothorax, and pleural effusion on chest radiographs. However, they produced more false-positive findings than radiology reports, and their performance decreased for smaller-sized target findings and when multiple findings were present. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Yanagawa and Tomiyama in this issue.


Assuntos
Aprendizado Profundo , Derrame Pleural , Pneumotórax , Adulto , Humanos , Feminino , Idoso , Inteligência Artificial , Pneumotórax/diagnóstico por imagem , Estudos Retrospectivos , Radiografia Torácica/métodos , Sensibilidade e Especificidade , Derrame Pleural/diagnóstico por imagem
2.
Radiology ; 307(3): e222268, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36880947

RESUMO

Background Automated interpretation of normal chest radiographs could alleviate the workload of radiologists. However, the performance of such an artificial intelligence (AI) tool compared with clinical radiology reports has not been established. Purpose To perform an external evaluation of a commercially available AI tool for (a) the number of chest radiographs autonomously reported, (b) the sensitivity for AI detection of abnormal chest radiographs, and (c) the performance of AI compared with that of the clinical radiology reports. Materials and Methods In this retrospective study, consecutive posteroanterior chest radiographs from adult patients in four hospitals in the capital region of Denmark were obtained in January 2020, including images from emergency department patients, in-hospital patients, and outpatients. Three thoracic radiologists labeled chest radiographs in a reference standard based on chest radiograph findings into the following categories: critical, other remarkable, unremarkable, or normal (no abnormalities). AI classified chest radiographs as high confidence normal (normal) or not high confidence normal (abnormal). Results A total of 1529 patients were included for analysis (median age, 69 years [IQR, 55-69 years]; 776 women), with 1100 (72%) classified by the reference standard as having abnormal radiographs, 617 (40%) as having critical abnormal radiographs, and 429 (28%) as having normal radiographs. For comparison, clinical radiology reports were classified based on the text and insufficient reports excluded (n = 22). The sensitivity of AI was 99.1% (95% CI: 98.3, 99.6; 1090 of 1100 patients) for abnormal radiographs and 99.8% (95% CI: 99.1, 99.9; 616 of 617 patients) for critical radiographs. Corresponding sensitivities for radiologist reports were 72.3% (95% CI: 69.5, 74.9; 779 of 1078 patients) and 93.5% (95% CI: 91.2, 95.3; 558 of 597 patients), respectively. Specificity of AI, and hence the potential autonomous reporting rate, was 28.0% of all normal posteroanterior chest radiographs (95% CI: 23.8, 32.5; 120 of 429 patients), or 7.8% (120 of 1529 patients) of all posteroanterior chest radiographs. Conclusion Of all normal posteroanterior chest radiographs, 28% were autonomously reported by AI with a sensitivity for any abnormalities higher than 99%. This corresponded to 7.8% of the entire posteroanterior chest radiograph production. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Park in this issue.


Assuntos
Inteligência Artificial , Radiografia Torácica , Adulto , Humanos , Feminino , Idoso , Estudos Retrospectivos , Radiografia Torácica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiologistas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA