Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1277: 341660, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37604613

RESUMO

Enzyme-linked immunosorbent assay protocols have traditionally complex workflows with several intensive wash steps. Analytical tools with both shorter time-to-result and hands-on-time using smaller sample and assays reagents volumes are now investigated. In this context, fluorescence resonance energy transfer (FRET)-based assays are emerging as one of the most promising analytical tools in high-throughput screening (HTS). These immunoassays allow fast quantification of antigens at the nano-gram level in a final assay volume of only a few µL. We used a homogeneous time-resolved FRET (called HTRF) assay to develop a freeze-dried screening and ready-to-use format with only one rehydration step called "instant assay". To assure optimal performance of the developed homogeneous instant assay, we investigated the critical quality attributes by studying the functionality and stability of the critical reagents and fluorophores. The cyclic adenosine 3'-5'-monophosphate (cAMP) was selected as the antigen target. We tested various formulations (with different buffers, sugars, bulking reagents, surfactants and co-solvants) combined with a slow freezing and the use of an aluminium plate holder during the freeze-drying of few microliter of bioreagents. The optimized freeze-drying procedure permits to preserve more than 70% of Ab recognition properties. The developed off-the-shelf homogeneous FRET immunoassay allows direct and fast quantification of cAMP at a nanogram level.


Assuntos
Alumínio , Anticorpos , Ensaio de Imunoadsorção Enzimática , Bioensaio , Transferência Ressonante de Energia de Fluorescência
2.
Talanta ; 178: 922-927, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136917

RESUMO

Antibody-coated surfaces (Ab surfaces) play a key role in bioanalytical tools developed for biosensors and diagnostics. Therefore, a high and well-defined functional activity of the Ab surface is required. The functional activity of the Ab surface depends on its available binding sites i.e. "the active sites" that are able to capture antigen (Ag). The number of active binding sites strongly depends on the immobilization strategy used to fix the Ab on the solid surface. Determination of layer thickness or surface topology are often used to characterize the Ab surfaces but there is no gold standard method for the study of the functionality of the Ab surfaces. For that purpose, we aim at developing an assay allowing to determine the performances of Ab surfaces. In the present study, anti-horseradish peroxidase antibody (anti-HRP Ab) is used as capture Ab covalently bound to the surface and enzyme HRP as Ag. This direct assay permits, in one-step, to generate a signal utilizing the catalytic properties of HRP. The signal is directly proportional to the amount of HRP bound on the Ab surface, and therefore to the active binding sites of immobilized Ab. The HRP/anti-HRP Ab interactions may be a useful indicator to construct accurate and reproducible active Ab surfaces and also to improve their performances in term of stability and sensitivity. Optimization of the assay parameters and quality of the results are presented. A good repeatability and an acceptable inter-day precision (RSD < 10%) are reported.


Assuntos
Anticorpos/imunologia , Antígenos/imunologia , Peroxidase do Rábano Silvestre/imunologia , Imunoensaio/métodos , Animais
3.
Astrobiology ; 11(3): 207-11, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21434764

RESUMO

Biochips are promising instruments for the search for organic molecules in planetary environments. Nucleic acid aptamers are powerful affinity receptors known for their high affinity and specificity, and therefore are of great interest for space biochip development. A wide variety of aptamers have already been selected toward targets of astrobiological interest (from amino acids to microorganisms). We present a first study to test the resistance of these receptors to the constraints of the space environment. The emphasis is on the effect of cosmic rays on the molecular recognition properties of DNA aptamers. Experiments on beam-line facilities have been conducted with 2 MeV protons and fluences much higher than expected for a typical mission to Mars. Our results show that this irradiation process did not affect the performances of DNA aptamers as molecular recognition tools.


Assuntos
Aptâmeros de Nucleotídeos/efeitos da radiação , Radiação Cósmica , Prótons , Exobiologia/métodos , Fluoresceína/efeitos da radiação , Corantes Fluorescentes/efeitos da radiação , Liofilização
4.
Anal Bioanal Chem ; 399(6): 2295-302, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21203751

RESUMO

The functionalization of surfaces with amino groups is used in many application areas such as in industrial biocatalytic processes for the development of medical biomaterials and in the environment for removing pollutants from water. Amino group density and grafting stability are often related to functionalized material performances; thus, their characterizations are of prime importance. The determination of amino density and grafting stability on polymeric material (e.g. polypropylene, polystyrene and cylco olefin copolymer) is often time consuming and sometimes presents technical constraints, more particularly with non-flat materials. In this paper, we report a novel colorimetric assay using the Coomassie Brilliant Blue dye for both amino density determination and grafting stability measurement. The assay named ADECA for "Amino Density Estimation by Colorimetric Assay" is sensitive, rapid, robust and versatile. We demonstrate that ADECA makes the evaluation of aminated materials performances possible for numerous material compositions, formats and chemistries used for grafting. Our study focuses on dendrigraft of poly-L-lysine and poly(amidoamine) dendrimers dendritic materials.


Assuntos
Aminas/química , Colorimetria/métodos , Dendrímeros/química , Materiais Dentários/química , Propriedades de Superfície
5.
Astrobiology ; 9(7): 637-45, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19778275

RESUMO

Detecting life in the Solar System is one of the great challenges of new upcoming space missions. Biochips have been proposed as a way to detect organic matter on extraterrestrial objects. A biochip is a miniaturized device composed of biologically sensitive systems, such as antibodies, which are immobilized on a slide. In the case of in situ measurements, the main concern is to ensure the survival of the antibodies under space radiation. Our recent computing simulation of cosmic ray interactions with the martian environment shows that neutrons are one of the dominant species at soil level. Therefore, we have chosen, in a first approach, to study antibody resistance to neutrons by performing irradiation experiments at the Applications Interdisciplinaires des Faisceaux d'Ions en Région Aquitaine (AIFIRA) platform, a French ion beam facility at the Centre d'Etudes Nucléaires de Bordeaux-Gradignan in Bordeaux. Antibodies and fluorescent dyes, freeze-dried and in buffer solution, were irradiated with 0.6 MeV and 6 MeV neutrons. Sample analyses demonstrated that, in the conditions tested, antibody recognition capability and fluorescence dye intensity are not affected by the neutrons.


Assuntos
Anticorpos/efeitos da radiação , Corantes/efeitos da radiação , Radiação Cósmica , Exobiologia/métodos , Fluoresceína/efeitos da radiação , Nêutrons , Sítios de Ligação , Soluções Tampão , Simulação por Computador , Liofilização , Soluções , Análise Espectral , Volatilização/efeitos da radiação
6.
Astrobiology ; 9(3): 311-23, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19368517

RESUMO

Simulations with a Monte Carlo tool kit have been performed to determine the radiation environment a specific device, called a biochip, would face if it were placed into a rover bound to explore Mars' surface. A biochip is a miniaturized device that can be used to detect organic molecules in situ. Its specific detection part is constituted of proteins whose behavior under cosmic radiation is completely unknown and must be investigated to ensure a good functioning of the device under space conditions. The aim of this study is to define particle species and energy ranges that could be relevant to investigate during experiments on irradiation beam facilities. Several primary particles have been considered for galactic cosmic ray (GCR) and solar energetic particle (SEP) contributions. Ionizing doses accumulated in the biochip and differential fluxes of protons, alphas, neutrons, gammas, and electrons have been established for both the Earth-Mars transit and the journey at Mars' surface. Neutrons and gammas appear as dominant species on martian soil, whereas protons dominate during the interplanetary travel. Depending on solar event occurrence during the mission, an ionizing dose of around a few Grays (1 Gy = 100 rad) is expected.


Assuntos
Radiação Cósmica , Meio Ambiente Extraterreno , Marte , Método de Monte Carlo , Voo Espacial/instrumentação , Simulação por Computador , Elétrons , Nêutrons , Prótons , Doses de Radiação , Monitoramento de Radiação/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA