Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-31944950

RESUMO

Bioresorbable vascular scaffold (BVS) has recently been spotlighted for its unique characteristics of absorbing into blood vessels and eventually disappearing. Although intravascular ultrasound (IVUS) is the most common guiding tool for stent deployment, the echogenicity of BVS struts has changed as the center of stent lumen and scanning rotation is not concentric, which may cause a critical erroneous measurement in practice. This study investigated the physical conditions for dimming the stent brightness in IVUS images using a finite-difference method (FDM) to numerically solve acoustic wave propagation through nonhomogeneous medium. The dimmed brightness is caused by an angled rectangular cross section of a strut and its similar acoustic impedance with water. Imaging frequency is not a major cause. However, the angle between the acoustic beam and the BVS surface is the major cause of the dimmed brightness. As a solution, an approach using a frequency compounding method with signal polarity comparator was proposed to recover the reduced brightness without sacrificing spatial resolutions. Based on the simulation study, the signal level from BVS can be attenuated down by 17 dB when the angle between the acoustic beamline and the surface of BVS is more than 45°. With the proposed frequency compounding approach, the reduced signal can be recovered by 6 dB. In the experimental BVS IVUS imaging, strut brightness was reduced by 18 dB with an angled strut position and recovered by 5 dB with the proposed frequency compounding method. A pig coronary was imaged to demonstrate the performance of the proposed method.


Assuntos
Implantes Absorvíveis , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Animais , Stents , Suínos
2.
IEEE Trans Biomed Eng ; 67(6): 1797-1805, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31634823

RESUMO

OBJECTIVE: Interventional ultrasound imaging is a prerequisite for guiding implants and treatment within the hearts and blood vessels. Due to limitations on the catheter's diameter, interventional ultrasonic transducers have side-looking structures although forward-looking imaging may provide more intuitive and real time guidance in treating diseased sites ahead of catheters. To address the issue, a magnetically actuated forward-looking interventional ultrasound imaging device is implemented for the first time. METHODS: A forward-looking catheter containing a 1 mm ring type focused 35 MHz ultrasound transducer and a micro magnet, was fabricated. For imaging, the transducer was placed at the center of four electromagnetic coils positioned on four sides of a squared acrylic housing. By modifying the magnetic field, the catheter tip could be remotely translated for sector scanning. RESULTS: The scanning angle could reach up to 3° in 1 Hz with 15 mT, while wider angles of 5° could be achieved with a higher magnetic field of 25 mT for ex-vivo imaging. The position of the transducer could be detected by monitoring the motion with a CCD camera, mimicking clinical X-ray imaging. In the wire target and tissue mimicking phantom studies, the measured hole size, spatial resolution and distance between wires by the proposed system were comparable with the values from a linear scanner. Multi-frame real time data acquisition was demonstrated via ex-vivo imaging on a pig's coronary artery. CONCLUSION/SIGNIFICANCE: The feasibility of magnetically actuated forward-looking interventional ultrasound imaging was demonstrated. The remote-controlled scanning method may allow to simplify the structures of forward-looking interventional ultrasound imaging catheters.


Assuntos
Transdutores , Ultrassonografia de Intervenção , Desenho de Equipamento , Estudos de Viabilidade , Imagens de Fantasmas
3.
Artigo em Inglês | MEDLINE | ID: mdl-29994203

RESUMO

Tissue harmonic imaging (THI), an essential mode of commercial ultrasound imaging scanners, can provide images with high spatial and contrast resolutions. For THI, the frequency spectrum of a transducer is generally divided for the transmission of fundamental signal and the reception of its second harmonic. Therefore, it is difficult to use the THI mode for intravascular ultrasound (IVUS) imaging because typical IVUS transducers have a narrow -6-dB fractional bandwidth of about 50%. Due to its small aperture (about 0.5 mm) and the strength of IVUS being too weak, it is difficult to construct a high-quality tissue harmonic image. In this paper, we report a recently developed dual-frequency oblong-shaped-focused IVUS transducer for high-quality intravascular THI; the transducer consists of three elements arranged side by side in the horizontal (i.e., elevation) direction. The two outer elements with a center frequency of 35 MHz are responsible for ultrasound transmission and the center element has a center frequency of 70 MHz for the reception of the second-harmonic signals. All three elements have a spherical shape with a radius of 3 mm to efficiently generate harmonics in the region of interest. This configuration of the developed IVUS transducer was determined to facilitate high-quality THI, which was based on the results of Field II simulation and finite-element analysis. The images of wires and a tissue-mimicking phantom indicated that the tissue harmonic images produced by the developed transducer have not only a high spatial resolution but also a deep imaging depth, compared to the 35- and 70-MHz fundamental images.


Assuntos
Transdutores , Ultrassonografia de Intervenção/instrumentação , Desenho de Equipamento , Ondas de Choque de Alta Energia , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Artigo em Inglês | MEDLINE | ID: mdl-29994523

RESUMO

Ultrasound guided needle biopsy is an important method for collection of breast cancer tissue. In this paper, we report on the design and testing of a high-voltage 1 to 64 Multiplexer/Demultiplexer (MUX/De-MUX) integrated circuit (IC) for ultrasound-guided breast biopsy applications implemented in a high-voltage CMOS process. The IC is intended to be incorporated inside the breast biopsy needle and is designed to fit inside the needle inner diameter of 2.38 mm. The MUX/De-MUX electronics are made up of three parts, including a low-voltage 6 to 64 decoder, a level shifter to convert from low voltage to high voltage, and analog high-voltage switches. Experimental results show a -3-dB bandwidth of over 70 MHz, Rds (on) of , -2.279-dB insertion loss, and -17.5-dB off isolation at 70 MHz with low-voltage input. Finally, we present results obtained via synthetic aperture imaging using the fabricated MUX/De-Mux device and a high-frequency ultrasound array. This device and technique hold promise for high-frequency imaging probes where a limited number of elements are used and the depth of penetration is short such as in breast biopsy and intravascular applications.


Assuntos
Biópsia por Agulha/métodos , Mama/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Ultrassonografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Transdutores
5.
Proc Natl Acad Sci U S A ; 115(5): 992-997, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29343642

RESUMO

While cell-based immunotherapy, especially chimeric antigen receptor (CAR)-expressing T cells, is becoming a paradigm-shifting therapeutic approach for cancer treatment, there is a lack of general methods to remotely and noninvasively regulate genetics in live mammalian cells and animals for cancer immunotherapy within confined local tissue space. To address this limitation, we have identified a mechanically sensitive Piezo1 ion channel (mechanosensor) that is activatable by ultrasound stimulation and integrated it with engineered genetic circuits (genetic transducer) in live HEK293T cells to convert the ultrasound-activated Piezo1 into transcriptional activities. We have further engineered the Jurkat T-cell line and primary T cells (peripheral blood mononuclear cells) to remotely sense the ultrasound wave and transduce it into transcriptional activation for the CAR expression to recognize and eradicate target tumor cells. This approach is modular and can be extended for remote-controlled activation of different cell types with high spatiotemporal precision for therapeutic applications.


Assuntos
Imunoterapia/métodos , Neoplasias/terapia , Animais , Fenômenos Biomecânicos , Sinalização do Cálcio , Genes Sintéticos , Engenharia Genética , Técnicas Genéticas , Células HEK293 , Humanos , Canais Iônicos/genética , Canais Iônicos/imunologia , Células Jurkat , Mecanotransdução Celular/genética , Mecanotransdução Celular/imunologia , Fatores de Transcrição NFATC/genética , Fatores de Transcrição NFATC/metabolismo , Neoplasias/genética , Neoplasias/imunologia , Biologia Sintética , Linfócitos T/imunologia , Ultrassom
6.
Sci Rep ; 7(1): 14092, 2017 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-29074938

RESUMO

Single-cell analysis is essential to understand the physical and functional characteristics of cells. The basic knowledge of these characteristics is important to elucidate the unique features of various cells and causative factors of diseases and determine the most effective treatments for diseases. Recently, acoustic tweezers based on tightly focused ultrasound microbeam have attracted considerable attention owing to their capability to grab and separate a single cell from a heterogeneous cell sample and to measure its physical cell properties. However, the measurement cannot be performed while trapping the target cell, because the current method uses long ultrasound pulses for grabbing one cell and short pulses for interrogating the target cell. In this paper, we demonstrate that short ultrasound pulses can be used for generating acoustic trapping force comparable to that with long pulses by adjusting the pulse repetition frequency (PRF). This enables us to capture a single cell and measure its physical properties simultaneously. Furthermore, it is shown that short ultrasound pulses at a PRF of 167 kHz can trap and separate either one red blood cell or one prostate cancer cell and facilitate the simultaneous measurement of its integrated backscattering coefficient related to the cell size and mechanical properties.


Assuntos
Análise de Célula Única/instrumentação , Análise de Célula Única/métodos , Ultrassom/instrumentação , Ultrassom/métodos , Fenômenos Biomecânicos , Células Sanguíneas/citologia , Células Sanguíneas/metabolismo , Linhagem Celular Tumoral , Tamanho Celular , Sobrevivência Celular , Desenho de Equipamento , Humanos , Masculino , Microscopia de Fluorescência , Poliestirenos , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia
7.
Sci Rep ; 6: 27238, 2016 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-27273365

RESUMO

We demonstrate a noncontact single-beam acoustic trapping method for the quantification of the mechanical properties of a single suspended cell with label-free. Experimentally results show that the single-beam acoustic trapping force results in morphological deformation of a trapped cell. While a cancer cell was trapped in an acoustic beam focus, the morphological changes of the immobilized cell were monitored using bright-field imaging. The cell deformability was then compared with that of a trapped polystyrene microbead as a function of the applied acoustic pressure for a better understanding of the relationship between the pressure and degree of cell deformation. Cell deformation was found to become more pronounced as higher pressure levels were applied. Furthermore, to determine if this acoustic trapping method can be exploited in quantifying the cell mechanics in a suspension and in a non-contact manner, the deformability levels of breast cancer cells with different degrees of invasiveness due to acoustic trapping were compared. It was found that highly-invasive breast cancer cells exhibited greater deformability than weakly-invasive breast cancer cells. These results clearly demonstrate that the single-beam acoustic trapping technique is a promising tool for non-contact quantitative assessments of the mechanical properties of single cells in suspensions with label-free.


Assuntos
Análise de Célula Única/instrumentação , Fenômenos Biomecânicos , Linhagem Celular Tumoral , Sobrevivência Celular , Humanos , Células MCF-7 , Micromanipulação/instrumentação , Micromanipulação/métodos , Microesferas , Tamanho da Partícula , Poliestirenos , Análise de Célula Única/métodos
8.
AIP Adv ; 6(3): 035102, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27014504

RESUMO

Single-beam acoustic tweezers (SBAT), used in laboratory-on-a-chip (LOC) device has promising implications for an individual micro-particle contactless manipulation. In this study, a freestanding hydrothermal PZT thick film with excellent piezoelectric property (d33 = 270pC/N and kt = 0.51) was employed for SBAT applications and a press-focusing technology was introduced. The obtained SBAT, acting at an operational frequency of 50MHz, a low f-number (∼0.9), demonstrated the capability to trap and manipulate a micro-particle sized 10µm in the distilled water. These results suggest that such a device has great potential as a manipulator for a wide range of biomedical and chemical science applications.

9.
Artigo em Inglês | MEDLINE | ID: mdl-26559626

RESUMO

Cell separation and sorting techniques have been employed biomedical applications such as cancer diagnosis and cell gene expression analysis. The capability to accurately measure ultrasonic scattering properties from cells is crucial in making an ultrasonic cell sorter a reality if ultrasound scattering is to be used as the sensing mechanism as well. To assess the performance of sensing and identifying live single cells with high-frequency ultrasound, an 86-MHz lithium niobate press-focused single-element acoustic transducer was used in a high-frequency ultrasound scattering measurement system that was custom designed and developed for minimizing noise and allowing better mobility. Peak-to-peak echo amplitude, integrated backscatter (IB) coefficient, spectral parameters including spectral slope and intercept, and midband fit from spectral analysis of the backscattered echoes were measured and calculated from a live single cell of two different types on an agar surface: leukemia cells (K562 cells) and red blood cells (RBCs). The amplitudes of echo signals from K562 cells and RBCs were 48.25 ± 11.98 mV(pp) and 56.97 ± 7.53 mV(pp), respectively. The IB coefficient was -89.39 ± 2.44 dB for K562 cells and -89.00 ± 1.19 dB for RBCs. The spectral slope and intercept were 0.30 ± 0.19 dB/MHz and -56.07 ± 17.17 dB, respectively, for K562 cells and 0.78 ± 0.092 dB/MHz and -98.18 ± 8.80 dB, respectively, for RBCs. Midband fits of K562 cells and RBCs were -31.02 ± 3.04 dB and -33.51 ± 1.55 dB, respectively. Acoustic cellular discrimination via these parameters was tested by Student's t-test. Their values, except for the IB value, showed statistically significant difference (p < 0.001). This paper reports for the first time that ultrasonic scattering measurements can be made on a live single cell with a highly focused high-frequency ultrasound microbeam at 86 MHz. These results also suggest the feasibility of ultrasonic scattering as a sensing mechanism in the development of ultrasonic cell sorters.


Assuntos
Separação Celular/métodos , Espalhamento de Radiação , Ondas Ultrassônicas , Eritrócitos , Humanos , Células K562 , Análise de Célula Única
10.
Biomed Opt Express ; 6(1): 11-22, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25657870

RESUMO

We demonstrate a novel non-contact method: acoustic radiation force impulse microscopy via photoacoustic detection (PA-ARFI), capable of probing cell mechanics. A 30 MHz lithium niobate ultrasound transducer is utilized for both detection of phatoacoustic signals and generation of acoustic radiation force. To track cell membrane displacements by acoustic radiation force, functionalized single-walled carbon nanotubes are attached to cell membrane. Using the developed microscopy evaluated with agar phantoms, the mechanics of highly- and weakly-metastatic breast cancer cells are quantified. These results clearly show that the PA-ARFI microscopy may serve as a novel tool to probe mechanics of single breast cancer cells.

11.
J R Soc Interface ; 12(103)2015 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-25505135

RESUMO

Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s(-1) with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation.


Assuntos
Diástole , Ecocardiografia Doppler , Coração/fisiologia , Regeneração , Peixe-Zebra , Animais
12.
Appl Phys Lett ; 105(21): 214103, 2014 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-25489120

RESUMO

We report the multiple micro-particle trapping and manipulation by a single-beam acoustic tweezer using a high-frequency array transducer. A single acoustic beam generated by a 30 MHz ultrasonic linear array transducer can entrap and transport multiple micro-particles located at the main lobe and the grating lobes. The distance between trapped particles can be adjusted by changing the transmit arrangement of array-based acoustic tweezers and subsequently the location of grating lobes. The experiment results showed that the proposed method can trap and manipulate multiple particles within a range of hundreds of micrometers. Due to its simplicity and low acoustic power, which is critical to protect cells from any thermal and mechanical damages, the technique may be used for transportation of cells in cell biology, biosensors, and tissue engineering.

13.
Appl Phys Lett ; 105(17): 173701, 2014 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-25422525

RESUMO

Tools that are capable of manipulating micro-sized objects have been widely used in such fields as physics, chemistry, biology, and medicine. Several devices, including optical tweezers, atomic force microscope, micro-pipette aspirator, and standing surface wave type acoustic tweezers have been studied to satisfy this need. However, none of them has been demonstrated to be suitable for in vivo and clinical studies. Single beam acoustic tweezers (SBAT) is a technology that uses highly focused acoustic beam to trap particles toward the beam focus. Its feasibility was first theoretically and experimentally demonstrated by Lee and Shung several years ago. Since then, much effort has been devoted to improving this technology. At present, the tool is capable of trapping a microparticle as small as 1 µm, as well as a single red blood cell. Although in comparing to other microparticles manipulating technologies, SBAT has advantages of providing stronger trapping force and deeper penetration depth in tissues, and producing less tissue damage, its potential for in vivo applications has yet been explored. It is worth noting that ultrasound has been used as a diagnostic tool for over 50 years and no known major adverse effects have been observed at the diagnostic energy level. This paper reports the results of an initial attempt to assess the feasibility of single beam acoustic tweezers to trap microparticles in vivo inside of a blood vessel. The acoustic intensity of SBAT under the trapping conditions that were utilized was measured. The mechanical index and thermal index at the focus of acoustic beam were found to be 0.48 and 0.044, respectively, which meet the standard of commercial diagnostic ultrasound system.

14.
Appl Phys Lett ; 104(24): 244107, 2014 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25114330

RESUMO

Multiparticle-trapping offers diverse opportunities and applications in biotechnology. It can be applied to creating various functional materials or organizing reactive particles. In this paper, we demonstrate that it is possible to trap and manipulate multi-particles in an annular pattern with a 24 MHz focused ring-type single element ultrasound transducer. Acoustic ring trap can be useful in undertaking biotropism studies due to an equal-distance condition from the center. Also, this ring trap could serve as a force shield to protect analysis area from other cells. The experimental results showed the capability of the proposed method as a multi-cell manipulator in formatting specific patterns of small cells like sperms.

15.
Ultrasound Med Biol ; 40(9): 2172-82, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25023109

RESUMO

We describe how contactless high-frequency ultrasound microbeam stimulation (HFUMS) is capable of eliciting cytoplasmic calcium (Ca(2+)) elevation in human umbilical vein endothelial cells. The cellular mechanotransduction process, which includes cell sensing and adaptation to the mechanical micro-environment, has been studied extensively in recent years. A variety of tools for mechanical stimulation have been developed to produce cellular responses. We developed a novel tool, a highly focused ultrasound microbeam, for non-contact cell stimulation at a microscale. This tool, at 200 MHz, was applied to human umbilical vein endothelial cells to investigate its potential to elicit an elevation in cytoplasmic Ca(2+) levels. It was found that the response was dose dependent, and moreover, extracellular Ca(2+) and cytoplasmic Ca(2+) stores were involved in the Ca(2+) elevation. These results suggest that high-frequency ultrasound microbeam stimulation is potentially a novel non-contact tool for studying cellular mechanotransduction if the acoustic pressures at such high frequencies can be quantified.


Assuntos
Células Endoteliais da Veia Umbilical Humana/diagnóstico por imagem , Mecanotransdução Celular/fisiologia , Estimulação Acústica/métodos , Cálcio/metabolismo , Ondas de Choque de Alta Energia , Humanos , Microscopia de Fluorescência , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Ultrassonografia
16.
Artigo em Inglês | MEDLINE | ID: mdl-24569245

RESUMO

The measurement of cell mechanics is crucial for a better understanding of cellular responses during the progression of certain diseases and for the identification of the cell's nature. Many techniques using optical tweezers, atomic force microscopy, and micro-pipettes have been developed to probe and manipulate cells in the spatial domain. In particular, we recently proposed a two-dimensional acoustic trapping method as an alternative technique for small particle manipulation. Although the proposed method may have advantages over optical tweezers, its applications to cellular mechanics have not yet been vigorously investigated. This study represents an initial attempt to use acoustic tweezers as a tool in the field of cellular mechanics in which cancer cell membrane deformability is studied. A press-focused 193-MHz single-element lithium niobate (LiNbO3) transducer was designed and fabricated to trap a 5-µm polystyrene microbead near the ultrasound beam focus. The microbeads were coated with fibronectin, and trapped before being attached to the surface of a human breast cancer cell (MCF-7). The cell membrane was then stretched by remotely pulling a cell-attached microbead with the acoustic trap. The maximum cell membrane stretched lengths were measured to be 0.15, 0.54, and 1.41 µm at input voltages to the transducer of 6.3, 9.5, and 12.6 Vpp, respectively. The stretched length was found to increase nonlinearly as a function of the voltage input. No significant cytotoxicity was observed to result from the bead or the trapping force on the cell during or after the deformation procedure. Hence, the results convincingly demonstrated the possible application of the acoustic trapping technique as a tool for cell manipulation.


Assuntos
Acústica/instrumentação , Membrana Celular/fisiologia , Separação Celular/instrumentação , Fibronectinas/farmacocinética , Fluidez de Membrana/efeitos da radiação , Micromanipulação/instrumentação , Som , Membrana Celular/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Fibronectinas/efeitos da radiação , Humanos , Microesferas , Nióbio/química , Nióbio/efeitos da radiação , Óxidos/química , Óxidos/efeitos da radiação
17.
Biotechnol Bioeng ; 110(10): 2697-705, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23568761

RESUMO

In this article, we investigate the application of contactless high frequency ultrasound microbeam stimulation (HFUMS) for determining the invasion potential of breast cancer cells. In breast cancer patients, the finding of tumor metastasis significantly worsens the clinical prognosis. Thus, early determination of the potential of a tumor for invasion and metastasis would significantly impact decisions about aggressiveness of cancer treatment. Recent work suggests that invasive breast cancer cells (MDA-MB-231), but not weakly invasive breast cancer cells (MCF-7, SKBR3, and BT-474), display a number of neuronal characteristics, including expression of voltage-gated sodium channels. Since sodium channels are often co-expressed with calcium channels, this prompted us to test whether single-cell stimulation by a highly focused ultrasound microbeam would trigger Ca(2+) elevation, especially in highly invasive breast cancer cells. To calibrate the diameter of the microbeam ultrasound produced by a 200-MHz single element LiNbO3 transducer, we focused the beam on a wire target and performed a pulse-echo test. The width of the beam was ∼17 µm, appropriate for single cell stimulation. Membrane-permeant fluorescent Ca(2+) indicators were utilized to monitor Ca(2+) changes in the cells due to HFUMS. The cell response index (CRI), which is a composite parameter reflecting both Ca(2+) elevation and the fraction of responding cells elicited by HFUMS, was much greater in highly invasive breast cancer cells than in the weakly invasive breast cancer cells. The CRI of MDA-MB-231 cells depended on peak-to-peak amplitude of the voltage driving the transducer. These results suggest that HFUMS may serve as a novel tool to determine the invasion potential of breast cancer cells, and with further refinement may offer a rapid test for invasiveness of tumor biopsies in situ.


Assuntos
Neoplasias da Mama , Espaço Intracelular , Invasividade Neoplásica , Imagem Óptica/métodos , Som , Antineoplásicos/farmacologia , Neoplasias da Mama/química , Neoplasias da Mama/metabolismo , Cálcio/análise , Cálcio/metabolismo , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Feminino , Humanos , Espaço Intracelular/química , Espaço Intracelular/efeitos dos fármacos , Espaço Intracelular/metabolismo , Espaço Intracelular/efeitos da radiação , Paclitaxel/farmacologia
18.
Appl Phys Lett ; 102(8): 84102, 2013 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-23526834

RESUMO

The purpose of this paper is to present a rapid and simple method to evaluate the trapping performance of high frequency focused ultrasonic transducers for acoustic tweezer applications. The method takes into consideration the friction between the particle to be trapped and the surface that it resides on. As a result it should be more reliable and accurate than the methods proposed previously. The trapping force produced by a 70-MHz press-focused transducer was measured to evaluate the performance of this approach. This method demonstrates its potential in optimizing the excitation conditions for acoustic tweezer applications and the design of acoustic tweezers.

19.
Biotechnol Bioeng ; 110(3): 881-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23042219

RESUMO

Similar to optical tweezers, a tightly focused ultrasound microbeam is needed to manipulate microparticles in acoustic tweezers. The development of highly sensitive ultrahigh frequency ultrasonic transducers is crucial for trapping particles or cells with a size of a few microns. As an extra lens would cause excessive attenuation at ultrahigh frequencies, two types of 200-MHz lensless transducer design were developed as an ultrasound microbeam device for acoustic tweezers application. Lithium niobate single crystal press-focused (PF) transducer and zinc oxide self-focused transducer were designed, fabricated and characterized. Tightly focused acoustic beams produced by these transducers were shown to be capable of manipulating single microspheres as small as 5 µm two-dimensionally within a range of hundreds of micrometers in distilled water. The size of the trapped microspheres is the smallest ever reported in the literature of acoustic PF devices. These results suggest that these lensless ultrahigh frequency ultrasonic transducers are capable of manipulating particles at the cellular level and that acoustic tweezers may be a useful tool to manipulate a single cell or molecule for a wide range of biomedical applications.


Assuntos
Biotecnologia/métodos , Som , Ultrassom/métodos , Microesferas , Tamanho da Partícula
20.
Appl Phys Lett ; 101(21): 214104, 2012 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-23258939

RESUMO

A high frequency ultrasonic phased array is shown to be capable of trapping and translating microparticles precisely and efficiently, made possible due to the fact that the acoustic beam produced by a phased array can be both focused and steered. Acoustic manipulation of microparticles by a phased array is advantageous over a single element transducer since there is no mechanical movement required for the array. Experimental results show that 45 µm diameter polystyrene microspheres can be easily and accurately trapped and moved to desired positions by a 64-element 26 MHz phased array.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA