Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 379
Filtrar
1.
PLoS One ; 19(6): e0304362, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38857214

RESUMO

This study aimed to define real-world prescription patterns in Korea and compare the effectiveness of chronic obstructive pulmonary disease (COPD) medications. We used national claims data provided by the Health Insurance Review and Assessment Service in Korea and examined patients who were first diagnosed with COPD and started treatment between May 1, 2017, and April 30, 2018, with no change in drug regimen. Among 30,784 patients with COPD, long-acting ß2 agonist (LABA) combined with long-acting muscarinic antagonist (LAMA) (32.7%), inhaled corticosteroid-LABA (ICS-LABA) (25.6%), LAMA (18.3%), ICS (5.8%), or LABA (4.6%) were prescribed as the first-choice inhalers. The use of LABA-LAMA (hazard ratio [HR], 0.248-0.584), LAMA (HR, 0.320-0.641), ICS-LABA (HR, 0.325-0.643), and xanthine (HR, 0.563-0.828) significantly reduced the total and severe exacerbation rates compared with no use of each medication. However, the use of ICS or LABA individually did not yield such effects. The continued use of LABA-LAMA, LAMA, and ICS-LABA showed a significant effect on exacerbation rate, whereas the long-term use of ICS, LABA, and xanthine did not. Moreover, some high doses of ICS-LABA did not show significant effects. This real-world study revealed that LAMA and/or LABA could be the first choice of therapy, as recommended by recent guidelines. However, ICS, xanthine, and high-dose ICS-LABA are still being prescribed frequently as first-line drugs in Korea.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2 , Antagonistas Muscarínicos , Doença Pulmonar Obstrutiva Crônica , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Antagonistas Muscarínicos/administração & dosagem , Antagonistas Muscarínicos/uso terapêutico , República da Coreia , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Administração por Inalação , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Padrões de Prática Médica/estatística & dados numéricos , Resultado do Tratamento , Broncodilatadores/uso terapêutico , Broncodilatadores/administração & dosagem , Prescrições de Medicamentos/estatística & dados numéricos , Adulto
2.
Nanoscale Adv ; 6(10): 2636-2643, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38752138

RESUMO

We report the first observation of spectral blue shift of plasmon resonance of synthesized silver nanoparticles (AgNPs) due to a negative optical nonlinearity of a local ambient medium, i.e., indigo carmine (IC) solution at around 420 nm wavelength. The blue shift occurred at a larger concentration of AgNPs or at a larger concentration of IC solution, being in obvious contrast to spectral red shift which was widely witnessed in plasmon spectral shift in a linear regime. Plasmon-enhanced local fields could excite the third-order optical nonlinearity for blue shift even under continuous (non-pulsed) light illumination. We also found that the plasmon-excited nonlinearity could allow for differential nonlinear response of the IC solution to be even greater than its differential linear response, though appearing to be somewhat inconsistent with what was generally known in light-matter interaction. The demonstrated properties of such anomalous shift of plasmon spectral peaks and its accompanying properties indicated that plasmon technologies could be exploited not only in linear but also in nonlinear aspects for critical optimization in plasmon-energy harvesting systems such as in surface enhanced spectroscopy/microscopy, biomedical imaging/sensing, laser frequency conversion, ultrashort pulse generation, and all-optical switching.

4.
bioRxiv ; 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38712092

RESUMO

Flexible intracortical neural probes have drawn attention for their enhanced longevity in high-resolution neural recordings due to reduced tissue reaction. However, the conventional monolithic fabrication approach has met significant challenges in: (i) scaling the number of recording sites for electrophysiology; (ii) integrating of other physiological sensing and modulation; and (iii) configuring into three-dimensional (3D) shapes for multi-sided electrode arrays. We report an innovative self-assembly technology that allows for implementing flexible origami neural probes as an effective alternative to overcome these challenges. By using magnetic-field-assisted hybrid self-assembly, multiple probes with various modalities can be stacked on top of each other with precise alignment. Using this approach, we demonstrated a multifunctional device with scalable high-density recording sites, dopamine sensors and a temperature sensor integrated on a single flexible probe. Simultaneous large-scale, high-spatial-resolution electrophysiology was demonstrated along with local temperature sensing and dopamine concentration monitoring. A high-density 3D origami probe was assembled by wrapping planar probes around a thin fiber in a diameter of 80∼105 µm using optimal foldable design and capillary force. Directional optogenetic modulation could be achieved with illumination from the neuron-sized micro-LEDs (µLEDs) integrated on the surface of 3D origami probes. We could identify angular heterogeneous single-unit signals and neural connectivity 360° surrounding the probe. The probe longevity was validated by chronic recordings of 64-channel stacked probes in behaving mice for up to 140 days. With the modular, customizable assembly technologies presented, we demonstrated a novel and highly flexible solution to accommodate multifunctional integration, channel scaling, and 3D array configuration.

5.
Respir Res ; 25(1): 213, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762465

RESUMO

BACKGROUND: Obesity is associated with airway hyperresponsiveness and lung fibrosis, which may reduce the effectiveness of standard asthma treatment in individuals suffering from both conditions. Statins and proprotein convertase subtilisin/kexin-9 inhibitors not only reduce serum cholesterol, free fatty acids but also diminish renin-angiotensin system activity and exhibit anti-inflammatory effects. These mechanisms may play a role in mitigating lung pathologies associated with obesity. METHODS: Male C57BL/6 mice were induced to develop obesity through high-fat diet for 16 weeks. Conditional TGF-ß1 transgenic mice were fed a normal diet. These mice were given either atorvastatin or proprotein convertase subtilisin/kexin-9 inhibitor (alirocumab), and the impact on airway hyperresponsiveness and lung pathologies was assessed. RESULTS: High-fat diet-induced obesity enhanced airway hyperresponsiveness, lung fibrosis, macrophages in bronchoalveolar lavage fluid, and pro-inflammatory mediators in the lung. These lipid-lowering agents attenuated airway hyperresponsiveness, macrophages in BALF, lung fibrosis, serum leptin, free fatty acids, TGF-ß1, IL-1ß, IL-6, and IL-17a in the lung. Furthermore, the increased RAS, NLRP3 inflammasome, and cholecystokinin in lung tissue of obese mice were reduced with statin or alirocumab. These agents also suppressed the pro-inflammatory immune responses and lung fibrosis in TGF-ß1 over-expressed transgenic mice with normal diet. CONCLUSIONS: Lipid-lowering treatment has the potential to alleviate obesity-induced airway hyperresponsiveness and lung fibrosis by inhibiting the NLRP3 inflammasome, RAS and cholecystokinin activity.


Assuntos
Dieta Hiperlipídica , Inibidores de Hidroximetilglutaril-CoA Redutases , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Obesidade , Fibrose Pulmonar , Animais , Masculino , Dieta Hiperlipídica/efeitos adversos , Obesidade/tratamento farmacológico , Obesidade/metabolismo , Camundongos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Fibrose Pulmonar/prevenção & controle , Fibrose Pulmonar/patologia , Fibrose Pulmonar/metabolismo , Fibrose Pulmonar/tratamento farmacológico , Inibidores de PCSK9 , Atorvastatina/farmacologia , Atorvastatina/uso terapêutico , Camundongos Obesos , Pró-Proteína Convertase 9/metabolismo , Pró-Proteína Convertase 9/genética , Anticorpos Monoclonais/farmacologia , Anticorpos Monoclonais/uso terapêutico , Hiper-Reatividade Brônquica/prevenção & controle , Hiper-Reatividade Brônquica/tratamento farmacológico , Hiper-Reatividade Brônquica/metabolismo , Hiper-Reatividade Brônquica/fisiopatologia , Anticorpos Monoclonais Humanizados
6.
Adv Mater ; : e2403090, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695508

RESUMO

The droplet-based electricity generator (DEG) has facilitated efficient droplet energy harvesting, yet diversifying its applications necessitates the incorporation of various to the DEG. In this study, we first propose a methodology for advancing the DEG by substituting its conventional metallic electrode with electrically conductive water electrode (WE), which is spontaneously generated during the operation of the DEG with operating liquid. Due to the inherent conductive and fluidic nature of water, the introduction of the WE maintains the electrical output performance of the DEG while imparting functionalities such as high transparency and flexibility. So, the resultant WE applied DEG (WE-DEG) exhibits high optical transmittance (∼ 99%) and retains its electricity-generating capability under varying deformations, including bending and stretching. This innovation expands the versatility of the DEG, and especially, a sun-raindrop dual-mode energy harvester is demonstrated by hybridizing the WE-DEG and photovoltaic (PV) cell. This hybridization effectively addresses the weather-dependent limitations inherent in each energy harvester and enhances the temperature-induced inefficiencies typically observed in PV cells, thereby enhancing the overall efficiency. The introduction of the WE will be poised to catalyze new developments in DEG research, paving the way for broader applicability and enhanced efficiency in droplet energy harvesting technologies. This article is protected by copyright. All rights reserved.

7.
Medicine (Baltimore) ; 103(15): e37830, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608073

RESUMO

The craniocervical flexion test (CCFT) is commonly used for assessing the performance and function of the deep cervical flexor muscles; however, objective measurements of cervical segmental motion during craniocervical flexion (CCF) are lacking. Therefore, the purpose of this study aimed to investigate cervical segmental motions during CCFT and determine the relationship between changes of cervical segmental motions and the cervical lordotic angle. A cross-sectional study of prospectively collected data. Twenty healthy participants without neck pain underwent standing cervical radiography (lateral view) to measure the cervical lordotic angle, followed by radiography in supine position during the CCFT. The occipito-atlantal (OA) joint angle, atlantoaxial (AA) joint angle, and cervical spinous process posterior displacement (CSPPD) of the C1-C6 vertebrae were measured using lateral cervical radiographs taken during the initial (20 mm Hg) and low-stage (24 mm Hg) CCFT conditions. The CCF motion during the low-stage CCFT was characterized by a significantly increased OA joint angle, decreased AA joint angle, and increased C1-C6 CSPPD compared with the initial stage (P < .05). The change in the value of C1-C6 CSPPD at low-stage CCFT showed a significant positive correlation with the cervical lordotic angle. These results indicate that the cervical lordotic angle is important in minimizing CSPPD and performing appropriately-isolated CCF motion during CCFT.


Assuntos
Atlas Cervical , Pescoço , Humanos , Estudos Transversais , Cervicalgia/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem
8.
Liver Int ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661296

RESUMO

BACKGROUND AND AIMS: The presence of steatosis in a donor liver and its relation to post-transplantation outcomes are not well defined. This study evaluates the effect of the presence and severity of micro- and macro-steatosis of a donor graft on post-transplantation outcomes. METHODS: The UNOS-STAR registry (2005-2019) was used to select patients who received a liver transplant graft with hepatic steatosis. The study cohort was stratified by the presence of macro- or micro-vesicular steatosis, and further stratified by histologic grade of steatosis. The primary endpoints of all-cause mortality and graft failure were compared using sequential Cox regression analysis. Analysis of specific causes of mortality was further performed. RESULTS: There were 9184 with no macro-steatosis (control), 150 with grade 3 macro-steatosis, 822 with grade 2 macro-steatosis and 12 585 with grade 1 macro-steatosis. There were 10 320 without micro-steatosis (control), 478 with grade 3 micro-steatosis, 1539 with grade 2 micro-steatosis and 10 404 with grade 1 micro-steatosis. There was no significant difference in all-cause mortality or graft failure among recipients who received a donor organ with any evidence of macro- or micro-steatosis, compared to those receiving non-steatotic grafts. There was increased mortality due to cardiac arrest among recipients of a grade 2 macro-steatosis donor organ. CONCLUSION: This study shows no significant difference in all-cause mortality or graft failure among recipients who received a donor liver with any degree of micro- or macro-steatosis. Further analysis identified increased mortality due to specific aetiologies among recipients receiving donor organs with varying grades of macro- and micro-steatosis.

9.
Science ; 384(6693): 312-317, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38669572

RESUMO

Electrostatic capacitors are foundational components of advanced electronics and high-power electrical systems owing to their ultrafast charging-discharging capability. Ferroelectric materials offer high maximum polarization, but high remnant polarization has hindered their effective deployment in energy storage applications. Previous methodologies have encountered problems because of the deteriorated crystallinity of the ferroelectric materials. We introduce an approach to control the relaxation time using two-dimensional (2D) materials while minimizing energy loss by using 2D/3D/2D heterostructures and preserving the crystallinity of ferroelectric 3D materials. Using this approach, we were able to achieve an energy density of 191.7 joules per cubic centimeter with an efficiency greater than 90%. This precise control over relaxation time holds promise for a wide array of applications and has the potential to accelerate the development of highly efficient energy storage systems.

10.
Acta Psychol (Amst) ; 245: 104234, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565067

RESUMO

With the freedom to consume content on preferred devices at any time as long as there is an Internet connection, the growing demand for over-the-top (OTT) services is evident. In conjunction with the rise of OTT services, binge-watching has become a prevalent behavior. In this research, we explore whether personality traits including the Big Five and need for cognition wield an effect on OTT use and binge-watching. We used a large, diverse, population representative sample from South Korea to investigate this topic. Results indicated that openness to experience and need for cognition were positively related to OTT use. Openness to experience, emotional stability, conscientiousness, and need for cognition had a negative association with binge-watching. When the sample was split by OTT frequency, the binge-watching effects were obtained exclusively for daily OTT users. For non-daily OTT users, most of the personality traits did not exert an effect on binge-watching. Implications of the current findings as well as limitations and future research are presented.


Assuntos
Cognição , Personalidade , Humanos , Emoções
11.
Adv Mater ; : e2400091, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573312

RESUMO

Crystallographic characteristics, including grain boundaries and crystallographic orientation of each grain, are crucial in defining the properties of two-dimensional materials (2DMs). To date, local microstructure analysis of 2DMs, which requires destructive and complex processes, is primarily used to identify unknown 2DM specimens, hindering the subsequent use of characterized samples. Here, a nondestructive large-area 2D crystallographic analytical method through sticky-note-like van der Waals (vdW) assembling-disassembling is presented. By the vdW assembling of veiled polycrystalline graphene (PCG) with a single-atom-thick single-crystalline graphene filter (SCG-filter), detailed crystallographic information of each grain in PCGs is visualized through a 2D Raman signal scan, which relies on the interlayer twist angle. The scanned PCGs are seamlessly separated from the SCG-filter using vdW disassembling, preserving their original condition. The remaining SCG-filter is then reused for additional crystallographic scans of other PCGs. It is believed that the methods can pave the way for advances in the crystallographic analysis of single-atom-thick materials, offering huge implications for the applications of 2DMs.

12.
J Dent ; 144: 104969, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38537881

RESUMO

OBJECTIVES: Natural teeth and dental restorations present with various shades and levels of translucency. This study aimed to determine whether these variations in ceramic crowns and scan powder application affect the trueness of intraoral scanners. METHODS: Eight identical premade resin typodonts, each prepared for a crown on the maxillary right second molar, were used. Eight lithium disilicate crowns, distinguished by two levels of translucency (high and low) and four shades (BL1, A2, A3, and A4), were fabricated to an identical design and cemented onto each typodont, providing eight distinct experimental groups (2 levels of translucency × 4 shades). Reference scans were acquired using a desktop scanner. Test scans were performed ten times for each experimental group using two different intraoral scanners (Medit i700 and CEREC Primescan AC), with and without the application of scan powder (n = 10). Three-dimensional metrology software was used to assess the trueness of the intraoral scan datasets. Statistical analysis involved the Kruskal-Wallis H test, Mann-Whitney U test, and independent t-test (α=0.05). RESULTS: For powder-free intraoral scan datasets, the crown shade did not significantly affect trueness within each translucency group (P = 1.000). For both intraoral scanners, compared with low translucency groups, higher marked deviations were exhibited by high translucency groups (P<.001). Scan powder use largely mitigated these differences (P>.05) and enhanced the trueness of the intraoral scan (P<.01). CONCLUSIONS: Shade did not significantly influence the trueness of intraoral scans. High-translucency crowns were scanned with less accuracy than were low-translucency crowns. CLINICAL SIGNIFICANCE: Unlike tooth shade, translucency significantly affected the accuracy of intraoral scans. Therefore, considering the use of scan powder when scanning objects with high translucency may be beneficial.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Pós , Humanos , Porcelana Dentária/química , Cor , Pigmentação em Prótese , Imageamento Tridimensional/métodos , Cerâmica , Dente Molar/diagnóstico por imagem , Dente Molar/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos
13.
Drug Saf ; 47(7): 673-686, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38512445

RESUMO

INTRODUCTION: Angiotensin receptor blockers are widely used antihypertensive drugs in South Korea. In 2021, the Korea Ministry of Food and Drug Safety acknowledged the need for national compensation for a drug-induced liver injury (DILI) after azilsartan use. However, little is known regarding the association between angiotensin receptor blockers and DILI. OBJECTIVE: We conducted a retrospective cohort study in incident users of angiotensin receptor blockers from a common data model database (1 January, 2017-31 December, 2021) to compare the risk of DILI among specific angiotensin receptor blockers against valsartan. METHODS: Patients were assigned to treatment groups at cohort entry based on prescribed angiotensin receptor blockers. Drug-induced liver injury was operationally defined using the International DILI Expert Working Group criteria. Cox regression analyses were conducted to derive hazard ratios and the inverse probability of treatment weighting method was applied. All analyses were performed using R. RESULTS: In total, 229,881 angiotensin receptor blocker users from 20 university hospitals were included. Crude DILI incidence ranged from 15.6 to 82.8 per 1000 person-years in treatment groups, most were cholestatic and of mild severity. Overall, the risk of DILI was significantly lower in olmesartan users than in valsartan users (hazard ratio: 0.73 [95% confidence interval 0.55-0.96]). In monotherapy patients, the risk was significantly higher in azilsartan users than in valsartan users (hazard ratio: 6.55 [95% confidence interval 5.28-8.12]). CONCLUSIONS: We found a significantly higher risk of suspected DILI in patients receiving azilsartan monotherapy compared with valsartan monotherapy. Our findings emphasize the utility of real-world evidence in advancing our understanding of adverse drug reactions in clinical practice.


Assuntos
Antagonistas de Receptores de Angiotensina , Doença Hepática Induzida por Substâncias e Drogas , Registros Eletrônicos de Saúde , Humanos , República da Coreia/epidemiologia , Estudos Retrospectivos , Doença Hepática Induzida por Substâncias e Drogas/epidemiologia , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Masculino , Feminino , Antagonistas de Receptores de Angiotensina/efeitos adversos , Pessoa de Meia-Idade , Registros Eletrônicos de Saúde/estatística & dados numéricos , Idoso , Estudos de Coortes , Anti-Hipertensivos/efeitos adversos , Incidência , Adulto , Valsartana/efeitos adversos , Fatores de Risco , Benzimidazóis/efeitos adversos
14.
Nat Commun ; 15(1): 2172, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467601

RESUMO

Semi-infinite single-atom-thick graphene is an ideal reinforcing material that can simultaneously improve the mechanical, electrical, and thermal properties of matrix. Here, we present a float-stacking strategy to accurately align the monolayer graphene reinforcement in polymer matrix. We float graphene-poly(methylmethacrylate) (PMMA) membrane (GPM) at the water-air interface, and wind-up layer-by-layer by roller. During the stacking process, the inherent water meniscus continuously induces web tension of the GPM, suppressing wrinkle and folding generation. Moreover, rolling-up and hot-rolling mill process above the glass transition temperature of PMMA induces conformal contact between each layer. This allows for pre-tension of the composite, maximizing its reinforcing efficiency. The number and spacing of the embedded graphene fillers are precisely controlled. Notably, we accurately align 100 layers of monolayer graphene in a PMMA matrix with the same intervals to achieve a specific strength of about 118.5 MPa g-1 cm3, which is higher than that of lightweight Al alloy, and a thermal conductivity of about 4.00 W m-1 K-1, which is increased by about 2,000 %, compared to the PMMA film.

15.
Sci Total Environ ; 925: 171745, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38508257

RESUMO

Forests are significant carbon reservoirs, with approximately one-third of this carbon stored in the soil. Forest thinning, a prevalent management technique, is designed to enhance timber production, preserve biodiversity, and maintain ecosystem functions. Through its influence on biotic and abiotic factors, thinning can profoundly alter soil carbon storage. Yet, the full implications of thinning on forest soil carbon reservoirs and the mechanisms underpinning these changes remain elusive. In this study, we undertook a two-year monitoring initiative, tracking changes in soil extracellular enzyme activities (EEAs), microbial communities, and other abiotic parameters across four thinning intensities within a temperate pine forest. Our results show a marked increase in soil carbon stock following thinning. However, thinning also led to decreased dissolved organic carbon (DOC) content and a reduced DOC to soil organic carbon (SOC) ratio, pointing toward a decline in soil carbon lability. Additionally, fourier transform infrared spectroscopy (FTIR) analysis revealed an augmented relative abundance of aromatic compounds after thinning. There was also a pronounced increase in absolute EEAs (per gram of dry soil) post-thinning, implying nutrient limitations for soil microbes. Concurrently, the composition of bacterial and fungal communities shifted toward oligotrophic dominance post thinning. Specific EEAs (per gram of soil organic matter) exhibit a significant reduction following thinning, indicating a deceleration in organic matter decomposition rates. In essence, our findings reveal that thinning transitions soil toward an oligotrophic state, dampening organic matter decomposition, and thus bolstering the soil carbon storage potential of forest. This study provides enhanced insights into the nuanced relationship between thinning practices and forest soil carbon dynamics, serving as a robust foundation for enlightened forest management strategies.


Assuntos
Microbiota , Solo , Solo/química , Carbono , Florestas , Compostos Orgânicos , Microbiologia do Solo , Matéria Orgânica Dissolvida
16.
Nat Commun ; 15(1): 2138, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459015

RESUMO

The advanced patterning process is the basis of integration technology to realize the development of next-generation high-speed, low-power consumption devices. Recently, area-selective atomic layer deposition (AS-ALD), which allows the direct deposition of target materials on the desired area using a deposition barrier, has emerged as an alternative patterning process. However, the AS-ALD process remains challenging to use for the improvement of patterning resolution and selectivity. In this study, we report a superlattice-based AS-ALD (SAS-ALD) process using a two-dimensional (2D) MoS2-MoSe2 lateral superlattice as a pre-defining template. We achieved a minimum half pitch size of a sub-10 nm scale for the resulting AS-ALD on the 2D superlattice template by controlling the duration time of chemical vapor deposition (CVD) precursors. SAS-ALD introduces a mechanism that enables selectivity through the adsorption and diffusion processes of ALD precursors, distinctly different from conventional AS-ALD method. This technique facilitates selective deposition even on small pattern sizes and is compatible with the use of highly reactive precursors like trimethyl aluminum. Moreover, it allows for the selective deposition of a variety of materials, including Al2O3, HfO2, Ru, Te, and Sb2Se3.

17.
Int J Prosthodont ; 37(7): 55-62, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489221

RESUMO

PURPOSE: To evaluate the wear resistance of a printed interim resin manufactured with different printing and postpolymerization parameters. MATERIALS AND METHODS: Overall, 130 rectangular resin specimens (15 × 10 × 10 mm) were 3D-printed. Among the specimens, 60 were printed with different printing orientations (0, 45, and 90 degrees) and layer thicknesses (50 and 100 µm) to create six groups to investigate the effects of the printing parameters (n = 10 per group). The remaining 70 specimens were used to evaluate the effects of postpolymerization; for this, seven groups were created as follows (n = 10 per group): nonpostpolymerized; postpolymerized for 5, 15, and 30 minutes with an ultraviolet light-emitting diode (LED) device; and postpolymerized for 5, 15, and 30 minutes with an ultraviolet light bulb device. After masticatory simulation, the wear volume loss was calculated with 3D metrology software. One-way and two-way ANOVA were used for intergroup comparisons (α = .05). RESULTS: The group printed with a build angle of 45 degrees showed lower wear volume loss than the 0- and 90-degree groups (P < .01). The wear volume loss in the ultraviolet LED group was significantly greater than that in the ultraviolet light bulb group (P = .04). No significant difference was observed in the wear volume loss of the printed resin with respect to the layer thickness and polymerization time (P > .05). However, the non-postpolymerized group showed significantly greater wear volume loss than the other groups (P < .001). CONCLUSIONS: The printed resin showed greater wear resistance when it was printed at a build angle of 45 degrees and postpolymerized with an ultraviolet light bulb device.


Assuntos
Impressão Tridimensional , Software , Teste de Materiais , Simulação por Computador
18.
J Exerc Rehabil ; 20(1): 42-48, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38433858

RESUMO

This study aims to demonstrate that when performing dynamic time warping (DTW) on gait data, multiple optimal warping paths (OWPs) with a minimum sum of local costs can occur and to propose an additional OWP selection method to address this problem. A 3-dimensional motion analysis experiment was conducted on 55 adult participants, including both males and females, to acquire gait data. This study analyzed 990 instances of DTW on gait data to examine the occurrence of multiple OWPs with the minimum sum of local costs. We subsequently applied an additional selection method to the multiple OWPs to determine the feasibility of identifying a single OWP. Multiple OWPs through DTW were observed 82 times, accounting for 8.28%. Notably, on the ankle joint of males, the rate was the highest at 11.11%. Cases with two multiple OWPs were the most prevalent at 56.10%, and cases with ten or more multiple OWPs accounted for 19.51%. The additional selection method proposed in this study was applied to the 82 instances in which multiple OWPs occurred. The results demonstrated the ability to identify a unique OWP in all cases. These results hold significance in identifying the shortcomings of conventional OWP selection methods previously employed and proposing solutions. It enhances the reliability, validity, and accuracy of studies utilizing DTW.

19.
Nat Commun ; 15(1): 1772, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413568

RESUMO

Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution printing of liquid metals forms soft neural probes with a cellular-scale diameter and adaptable lengths. Also, the printing of liquid metal-based circuits and interconnections along the curvature of the cranium enables the conformal integration of electronics to the body, and the cranial circuit delivers neural signals to a smartphone wirelessly. In the in-vivo studies using mice, the system demonstrates long-term recording (33 weeks) of neural activities in arbitrary brain regions. In T-maze behavioral tests, the system shows the behavior-induced activation of neurons in multiple brain regions.


Assuntos
Eletrônica , Neurônios , Animais , Camundongos , Neurônios/fisiologia , Encéfalo/fisiologia , Crânio/diagnóstico por imagem , Metais , Impressão Tridimensional
20.
Dent Mater J ; 43(2): 216-226, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417860

RESUMO

This study aimed to investigate the effects of sandblasting on the physical properties and bond strength of two types of translucent zirconia: niobium-oxide-containing yttria-stabilized tetragonal zirconia polycrystals ((Y, Nb)-TZP) and 5 mol% yttria-partially stabilized zirconia (5Y-PSZ). Fully sintered disc specimens were either sandblasted with 125 µm alumina particles or left as-sintered. Surface roughness, crystal phase compositions, and surface morphology were explored. Biaxial flexural strength (n=10) and shear bond strength (SBS) (n=12) were evaluated, including thermocycling conditions. Results indicated a decrease in flexural strength of 5Y-PSZ from 601 to 303 MPa upon sandblasting, while (Y, Nb)-TZP improved from 458 to 544 MPa. Both materials significantly increased SBS after sandblasting (p<0.001). After thermocycling, (Y, Nb)-TZP maintained superior SBS (14.3 MPa) compared to 5Y-PSZ (11.3 MPa) (p<0.001). The study concludes that (Y, Nb)-TZP is preferable for sandblasting applications, particularly for achieving durable bonding without compromising flexural strength.


Assuntos
Materiais Dentários , Nióbio , Óxidos , Materiais Dentários/química , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Ítrio/química , Óxido de Alumínio , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA