Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Urol ; 24(1): 139, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965501

RESUMO

BACKGROUND: An intravesical gas explosion is a rare complication of transurethral resection of the prostate (TURP). It was first reported in English literature in 1926, and up to 2022 were only forty-one cases. Injury from an intravesical gas explosion, in the most severe cases appearing as extraperitoneal or intraperitoneal bladder rupture needed emergent repair surgery. CASE PRESENTATION: We present a case of a 75-year-old man who suffered an intravesical gas explosion during TURP. The patient underwent an emergent exploratory laparotomy for bladder repair and was transferred to the intensive care unit for further observation and treatment. Under the medical team's care for up to sixty days, the patient recovered smoothly without clinical sequelae. CONCLUSIONS: This case report presents an example of a rare complication of intravesical gas explosion during TURP, utilizing root cause analysis (RCA) to comprehend causal relationships and team strategies and tools to improve performance and patient safety (TeamSTEPPS) method delivers four teamwork skills that can be utilized during surgery and five recommendations to avoid gas explosions during TURP to prevent the recurrence of medical errors. In modern healthcare systems, promoting patient safety is crucial. Once complications appear, RCA and TeamSTEPPS are helpful means to support the healthcare team reflect and improve as a team.


Assuntos
Explosões , Análise de Causa Fundamental , Ressecção Transuretral da Próstata , Bexiga Urinária , Humanos , Masculino , Idoso , Ressecção Transuretral da Próstata/efeitos adversos , Bexiga Urinária/cirurgia , Bexiga Urinária/lesões , Gases , Equipe de Assistência ao Paciente , Complicações Intraoperatórias/etiologia
2.
IEEE Trans Neural Syst Rehabil Eng ; 24(11): 1199-1209, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26929055

RESUMO

This paper presents an assistive control system with a special kinematic structure of an upper limb rehabilitation robot embedded with force/torque sensors. A dynamic human model integrated with sensing torque is used to simulate human interaction under three rehabilitation modes: active mode, assistive mode, and passive mode. The hereby proposed rehabilitation robot, called NTUH-ARM, provides 7 degree-of- freedom (DOF) motion and runs subject to an inherent mapping between the 7 DOFs of the robot arm and the 4 DOFs of the human arm. The Lyapunov theory is used to analyze the stability of the proposed controller design. Clinical trials have been conducted with six patients, one of which acts as a control. The results of these experiments are positive and STREAM assessment by physical therapists also reveals promising results.


Assuntos
Biorretroalimentação Psicológica/instrumentação , Modelos Biológicos , Terapia Passiva Contínua de Movimento/instrumentação , Transtornos dos Movimentos/reabilitação , Robótica/instrumentação , Terapia Assistida por Computador/instrumentação , Braço , Biorretroalimentação Psicológica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Exoesqueleto Energizado , Humanos , Terapia Passiva Contínua de Movimento/métodos , Reabilitação Neurológica/instrumentação , Reabilitação Neurológica/métodos , Robótica/métodos , Terapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS