Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; : e2400622, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820600

RESUMO

Virion-mediated outbreaks are imminent and despite rapid responses, continue to cause adverse symptoms and death. Therefore, tunable, sensitive, high-throughput assays are needed to help diagnose future virion-mediated outbreaks. Herein, it is developed a tunable in situ assay to selectively enrich virions and extracellular vesicles (EVs) and simultaneously detect antigens and nucleic acids at a single-particle resolution. The Biochip Antigen and RNA Assay (BARA) enhanced sensitivities compared to quantitative reverse-transcription polymerase chain reaction (qRT-PCR), enabling the detection of virions in asymptomatic patients, genetic mutations in single virions, and enabling the continued long-term expression of viral RNA in the EV-enriched subpopulation in the plasma of patients with post-acute sequelae of the coronavirus disease of 2019 (COVID-19). BARA revealed highly accurate diagnoses of COVID-19 by simultaneously detecting the spike glycoprotein and nucleocapsid-encoding RNA in saliva and nasopharyngeal swab samples. Altogether, the single-particle detection of antigens and viral RNA provides a tunable framework for the diagnosis, monitoring, and mutation screening of current and future outbreaks.

2.
Adv Sci (Weinh) ; 11(11): e2306373, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38204202

RESUMO

Detecting pancreatic duct adenocarcinoma (PDAC) in its early stages and predicting late-stage patient prognosis undergoing chemotherapy is challenging. This work shows that the activation of specific oncogenes leads to elevated expression of mRNAs and their corresponding proteins in extracellular vesicles (EVs) circulating in blood. Utilizing an immune lipoplex nanoparticle (ILN) biochip assay, these findings demonstrate that glypican 1 (GPC1) mRNA expression in the exosomes-rich (Exo) EV subpopulation and GPC1 membrane protein (mProtein) expression in the microvesicles-rich (MV) EV subpopulation, particularly the tumor associated microvesicles (tMV), served as a viable biomarker for PDAC. A combined analysis effectively discriminated early-stage PDAC patients from benign pancreatic diseases and healthy donors in sizable clinical from multiple hospitals. Furthermore, among late-stage PDAC patients undergoing chemotherapy, lower GPC1 tMV-mProtein and Exo-mRNA expression before treatment correlated significantly with prolonged overall survival. These findings underscore the potential of vesicular GPC1 expression for early PDAC screenings and chemotherapy prognosis.


Assuntos
Carcinoma Ductal Pancreático , Vesículas Extracelulares , Neoplasias Pancreáticas , Humanos , Biomarcadores Tumorais/genética , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/genética , Vesículas Extracelulares/metabolismo , Glipicanas/genética , Glipicanas/metabolismo , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Prognóstico , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
3.
Lab Chip ; 24(4): 819-831, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38235543

RESUMO

Localized micro/nano-electroporation (MEP/NEP) shows tremendous potential in cell transfection with high cell viability, precise dose control, and good transfection efficacy. In MEP/NEP, micro or nanochannels are used to tailor the electric field distribution. Cells are positioned tightly by a micron or nanochannel, and the cargoes are delivered into the cell via the channel by electrophoresis (EP). Such confined geometries with micro and nanochannels are also widely used in sorting, isolation, and condensing of biomolecules and cells. Theoretical studies on the electrokinetic phenomena in these applications have been well established. However, for MEP/NEP applications, electrokinetic phenomena and their impact on the cell transfection efficiency and cell survival rate have not been studied comprehensively. In this work, we reveal the coupling between electric field, Joule heating, electroosmosis (EO), and EP in MEP/NEP at different channel sizes. A microfluidic biochip is used to investigate the electrokinetic phenomena in MEP/NEP on a single cell level. Bubble formation is observed at a threshold voltage due to Joule heating. The bubble is pushed to the cargo side due to EO and grows at the outlet of the nanochannel. As the voltage increases, the cargo transport efficiency decreases due to more intense EO, particularly for plasmid DNAs (3.5 kbp) with a low EP mobility. An 'electroporation zone' is defined for NEP/MEP systems with different channel sizes to avoid bubble formation and excessive EO velocity that may reduce the cargo delivery efficiency.


Assuntos
Eletro-Osmose , Calefação , Eletroporação/métodos , Transfecção , Microfluídica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA