Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Headache ; 63(10): 1359-1371, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37975482

RESUMO

OBJECTIVE: To examine trends in diagnosis of headache and migraine in a large pediatric neurology cohort, and test whether an electronic health record (EHR)-integrated headache questionnaire can increase specificity of diagnosis and likelihood of prescribing migraine treatment. BACKGROUND: Under-diagnosis of migraine contributes to the burden of disease. As we founded our Pediatric Headache Program in 2013, we recognized that the proportion of patients with headache who were given a diagnosis of migraine was much lower than expected. METHODS: We developed a patient headache questionnaire, initially on paper (2013-2014), then in an electronic database (2014-2016), and finally integrated into our electronic health record (pilot: 2016, full: May 2017). We compared diagnoses and prescribed treatments for new patients who were given a headache diagnosis, looking at trends in the proportion of patients given specific diagnoses (migraine, etc.) versus the non-specific diagnosis, "headache." Next, we conducted a prospective cohort study to test for association between provider use of the form and the presence of a specific diagnosis, then for an association between specific diagnosis and prescription of migraine treatment. RESULTS: Between July 2011 and December 2022 the proportion of new headache patients who were given a diagnosis of migraine increased 9.7% and non-specific headache diagnoses decreased 21.0%. In the EHR cohort (June 2017-December 2022, n = 15,122), use of the provider form increased the rate of specific diagnosis to 87.2% (1839/2109) compared to 75.5% (5708/7560) without a patient questionnaire, nearly doubling the odds of making a specific diagnosis (odds ratio [OR] 1.90, 95% confidence interval [CI]: 1.65-2.19). Compared to those given only a non-specific headache diagnosis who were prescribed a migraine therapy 53.7% (1766/3286) of the time, 75.3% (8914/11836) of those given a specific diagnosis received a migraine therapy, more than doubling the odds of prescription (OR 2.39, 95% CI: 2.20-2.60). CONCLUSIONS: Interventions to improve specificity of diagnosis were effective and led to increased rates of prescription of migraine treatments. These results have been sustained over several years. This headache questionnaire was adapted into the Foundation system of EpicCare, so it is broadly available as a clinical and research tool for institutions that use this EHR software.


Assuntos
Transtornos de Enxaqueca , Neurologia , Humanos , Criança , Estudos Prospectivos , Cefaleia/diagnóstico , Cefaleia/terapia , Transtornos de Enxaqueca/terapia , Transtornos de Enxaqueca/tratamento farmacológico , Inquéritos e Questionários
2.
Radiat Oncol J ; 37(1): 37-42, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30947479

RESUMO

PURPOSE: To identify prognostic factors influencing progression-free survival (PFS) of aggressive fibromatosis (AF) after postoperative radiotherapy (PORT) and assess correlations between immunohistochemistry (IHC) features of ß-catenin/smooth muscle actin (SMA) and PFS. MATERIALS AND METHODS: Records of 37 patients with AF treated by PORT from 1984 to 2015 were retrospectively reviewed. Fifteen patients underwent wide excision for AF and 22 patients received debulking operation. The median total dose of PORT was 59.4 Gy. IHC staining results of ß-catenin and SMA were available for 11 and 12 patients, respectively. RESULTS: The median follow-up duration was 105.9 months. Five-year PFS rate was 70.9%. Tumor size or margin status was not related to PFS in univariate analysis (p = 0.197 and p = 0.716, respectively). Multivariate analysis showed that increased interval from surgery to PORT (>5.7 weeks) was a marginal risk factor for PFS (p = 0.054). Administration of PORT at the initial diagnosis resulted in significantly improved PFS compared to deferring PORT after recurrence (p = 0.045). Patient with both risk factors of deferring PORT after recurrence and interval from surgery to PORT >5.7 weeks had significantly lower 5-year PFS than patients without risk factor (34.1% vs. 100.0%; p = 0.012). Nuclear ß-catenin intensity tended to inversely correlate with 5-year PFS, although it did not reach statistical significance (62.5% at low vs. 100.0% at high; p = 0.260). SMA intensity was not related to PFS (p = 0.700). CONCLUSION: PORT should be performed immediately after surgery irrespective of margin status or tumor size especially in recurrent case. Nuclear ß-catenin staining intensity of IHC might correlate with local recurrence.

3.
Int J Gynecol Cancer ; 28(2): 371-378, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29189448

RESUMO

PURPOSE: We conducted this study to evaluate the outcomes of external-beam radiotherapy tumor boost (EBRT-B) in cervical cancer patients who could not receive intracavitary brachytherapy. METHODS: A total of 11 hospitals provided the data of patients who received EBRT-B during the period from January 2005 through October 2012. RESULTS: A total of 75 patients were included. The median radiotherapy dose was 46 Gy (range, 40-54 Gy) for whole pelvis and 24 Gy (range, 9-35 Gy) for EBRT-B. Initial tumor responses assessed at 2 to 6 months after radiotherapy were as follows: 46 with complete response, 22 with partial response, 2 with stable disease, and 3 with progressive disease. After a median follow-up time of 33 months, 30 patients (40.0%) showed disease progression including 21 (28.0%) with local progression. The 5-year local failure-free survival rate was 70.0%. Achieving complete response at the first follow-up visit and an overall treatment time of 53 days or less were significantly related to favorable local failure-free survival. The rate of grade 3 or higher toxicity was 2.6%. CONCLUSIONS: Approximately 70% of patients had local tumor control after curative radiotherapy using EBRT-B. Early tumor response and overall treatment time of 53 days or less were closely associated with favorable local control.


Assuntos
Braquiterapia , Carcinoma de Células Escamosas/radioterapia , Radioterapia de Intensidade Modulada/métodos , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Carcinoma de Células Escamosas/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Seleção de Pacientes , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento , Neoplasias do Colo do Útero/patologia
4.
Med Dosim ; 40(3): 240-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25724475

RESUMO

A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.


Assuntos
Algoritmos , Elétrons/uso terapêutico , Dispositivos de Proteção dos Olhos , Método de Monte Carlo , Proteção Radiológica/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Metais/efeitos da radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
5.
J Breast Cancer ; 17(1): 69-75, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24744800

RESUMO

PURPOSE: This study was performed to assess frequency, timings of occurrence, and predictors of radiologic lung damage (RLD) after forward-planned intensity-modulated radiotherapy (FIMRT) for whole breast irradiation. METHODS: We retrospectively reviewed medical records of 157 breast cancer patients and each of their serial chest computed tomography (CT) taken 4, 10, 16, and 22 months after completion of breast radiotherapy (RT). FIMRT was administered to whole breast only (n=152), or whole breast and supraclavicular regions (n=5). Dosimetric parameters, such as mean lung dose and lung volume receiving more than 10 to 50 Gy (V10-V50), and clinical parameters were analyzed in relation to radiologic lung damage. RESULTS: In total, 104 patients (66.2%) developed RLD after whole breast FIMRT. Among the cases of RLD, 84.7% were detected at 4 months, and 15.3% at 10 months after completion of RT. More patients of 47 or younger were found to have RLD at 10 months after RT than patients older than the age (11.7% vs. 2.9%, p=0.01). In univariate and multivariate analyses, age >47 and V40 >7.2% were significant predictors for higher risk of RLD. CONCLUSION: RLD were not infrequently detected in follow-up CT after whole breast FIMRT. More detected cases of RLD among younger patients are believed to have developed at later points after RT than those of older patients. Age and V40 were significant predictors for RLD after whole breast intensity-modulated radiotherapy.

6.
J Radiat Res ; 54(1): 174-81, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22915776

RESUMO

Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size as the tungsten eye shield was machined and CT scanned. The BEAMnrc and the DOSXYZnrc were used for the Monte Carlo (MC) simulation, with the appropriate material information and density for the aluminum cover, steel knob and tungsten body of the eye shield. The Pinnacle adopting the Hogstrom electron pencil-beam algorithm was used for the one-port 6-MeV beam plan after delineation and density override of the metallic parts. The results were confirmed with the metal oxide semiconductor field effect transistor (MOSFET) detectors and the Gafchromic EBT2 film measurements. For both the maximum eyelid dose over the shield and the maximum dose under the shield, the MC results agreed with the EBT2 measurements within 1.7%. For the Pinnacle plan, the maximum dose under the shield agreed with the MC within 0.3%; however, the eyelid dose differed by -19.3%. The adoption of the acrylic dummy eye shield was successful for the treatment plan. However, the Pinnacle pencil-beam algorithm was not sufficient to predict the eyelid dose on the tungsten shield, and more accurate algorithms like MC should be considered for a treatment plan.


Assuntos
Traumatismos Oculares/prevenção & controle , Dispositivos de Proteção dos Olhos , Neoplasias Palpebrais/radioterapia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/efeitos adversos , Elétrons/uso terapêutico , Desenho de Equipamento , Análise de Falha de Equipamento , Traumatismos Oculares/etiologia , Neoplasias Palpebrais/complicações , Humanos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Resultado do Tratamento
7.
Med Phys ; 39(5): 2524-35, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559623

RESUMO

PURPOSE: The authors aim was to investigate the effects of using transmission and reflection scanning modes, the film orientation during scanning, and ambient room light on a dosimetry system based on the Gafchromic(TM) EBT2 film model. METHODS: For calibration, the films were cut to 3 × 3 cm(2) and irradiated from 20 to 700 cGy at the depth of maximum dose using 6 and 10 MV photon beams in a 10 × 10 cm(2) field size. Absolute dose calibration of the linear accelerator was done according to the TRS398 protocol. An FG65-G ionization chamber was used to monitor the dose while irradiating the films in solid water. The film pieces were scanned with an EPSON Expression 1680 Pro flatbed scanner in transmission and reflection modes. Authors investigated the effect of orientation on films and examined the optical properties of EBT2 film using an ellipsometer and an ultraviolet (UV)/visible spectrometer to explain the dosimetric dependence of the film on orientation during the scanning process. To investigate the effect of ambient room light, films were preirradiated in 6 and 10 MV photon beams with intensity-modulated radiotherapy (IMRT) quality assurance (QA) plans, and then exposed to room light, either directly for 2 days in a workroom or for 2 months in a film box. Gamma index pass criteria of (3%, 3 mm) were used. RESULTS: The dose response curves based on net optical density (NOD) indicated that the reflection scanning mode can provide a better dose sensitivity than the transmission scanning mode, whereas the standard deviation of the dose is greater in reflection mode than in transmission mode. When the film was rotated 90° from the portrait orientation, the average dose of the EBT2 film decreased by 11.5-19.6% in transmission mode and by 1.5-2.3% in reflection mode. Using an ellipsometer, variation of the refractive index of EBT2 film-the birefringence property-was found to be the largest between 45° (1.72 and 1.71) and 135° (1.8 and 1.77) for 300 and 800 cGy. Absorption spectra of EBT2 films measured with spectrometer were the function of film orientation. The readings in reflection scanning mode were more stable against room light than those in transmission scanning mode, although dose readings increased in both modes after the films were exposed to room light. CONCLUSIONS: The transmission scanning mode exhibited a strong dependence on film orientation during scanning and a change in optical density resulting from room light exposure, so a constant scanning orientation and minimal exposure to light can reduce uncertainty in the measured dose (23 ± 3%). The angular dependence was analyzed using Jones matrices and optical properties of EBT2 film were obtained using an ellipsometer and an UV/visible spectrometer. The reflection scanning mode has relatively good stability with respect to room light and film orientation on a scanner, although the large standard deviation of dose is a disadvantage in measurements of absolute dose. Reflection scanning mode can offer a potential advantage for film dosimetry in radiotherapy, although transmission scanning mode is still recommended for dosimetry as it provides better uncertainty results.


Assuntos
Dosimetria Fotográfica/métodos , Fenômenos Ópticos , Doses de Radiação , Dosimetria Fotográfica/instrumentação , Luz
8.
Med Phys ; 37(3): 1146-51, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20384250

RESUMO

PURPOSE: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. METHODS: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. RESULTS: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within +/- 2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within +/- 0.5 MU regardless of dose rate and duty cycle. CONCLUSIONS: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.


Assuntos
Radioterapia Conformacional/instrumentação , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Clin Oncol ; 27(30): 5088-93, 2009 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-19770372

RESUMO

PURPOSE: To evaluate whether human papillomavirus (HPV) viral load measured in cervical smear and HPV type 18 are associated with radiotherapy outcomes in uterine cervical cancer. PATIENTS AND METHODS HPV DNA: was semiquantitatively measured in the cervical smears of 169 radiotherapy patients. HPV viral load was classified as low or high according to median HPV DNA titer and examined for its prognostic value. The multivariable Cox proportional hazards model was used to adjust for covariates. A relapse-predicting model was constructed to classify three risk groups for disease-free survival (DFS), which were used for internal validation. RESULTS: Patients with lower HPV viral load showed worse DFS in univariate analysis. HPV type 18, younger patient age, stage group, nodal status, histologic grade, and histologic type were other prognostic factors for poor DFS. Among these factors, all except stage group were associated with HPV viral load. Multivariate analysis showed the strong influence of HPV viral load for poor DFS. The prognostic model developed using our outcome data performed well in predicting the risk of relapse. CONCLUSION: Our data suggest that HPV viral load is a strong independent prognostic factor for DFS. HPV type 18 showed a significant relationship with poor radiotherapy outcome in univariate analysis, but not in multivariate analysis.


Assuntos
Adenocarcinoma/virologia , Carcinoma de Células Escamosas/virologia , Papillomavirus Humano 18/isolamento & purificação , Infecções por Papillomavirus/virologia , Neoplasias do Colo do Útero/virologia , Carga Viral , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , DNA Viral/genética , Feminino , Papillomavirus Humano 18/genética , Humanos , Pessoa de Meia-Idade , Prognóstico , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia , Esfregaço Vaginal , Adulto Jovem
10.
Gynecol Oncol ; 104(1): 95-9, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16996117

RESUMO

OBJECTIVES: To evaluate the toxicity and the efficacy of paclitaxel/carboplatin chemoradiotherapy as a definitive treatment for squamous cell cancer of the uterine cervix. METHODS: From March 2000 to January 2004, 33 patients with squamous cell cancer of the uterine cervix were treated with concurrent chemoradiotherapy including 2 cycles of paclitaxel (135 mg/m(2)) and carboplatin (area under the time-concentration curve 4.5 mg min/ml) at 4-week interval. Seven patients received adjuvant chemotherapy with the same chemotherapeutic regimen. All patients received external beam radiotherapy with 41.4-51.4 Gy (median 50.4 Gy) to the whole pelvis. Twenty-eight patients received boost irradiation to the cervix by brachytherapy with 25.6-43.3 Gy (median 34.6 Gy) and 5 patients by external beam radiotherapy with 10.8-14.4 Gy (median 14.4 Gy). RESULTS: A median follow-up period was 27 months (range: 6-53 months). Acute hematological toxicity of grade 3 or 4 developed in 20 patients (61%), and acute gastrointestinal toxicity of grade 3 developed in 1 patient (3%). Vesicovaginal fistula occurred in 2 patients (6%). All patients achieved objective response (CR 70%, PR 30%) in 2 months after termination of treatment. One patient had a local progression in cervix, and 4 patients developed distant metastases. The 3-year estimated disease-free survival rates for stages I-IIA, IIB, III and IV were 67%, 91%, 88% and 50%, respectively. The 3-year estimated survival rates for stages I-IIA, IIB, III and IV were 89%, 91%, 88% and 50%, respectively. CONCLUSION: Concurrent chemoradiotherapy with paclitaxel and carboplatin is effective to achieve an excellent pelvic control.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/radioterapia , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carboplatina/administração & dosagem , Carboplatina/efeitos adversos , Carcinoma de Células Escamosas/patologia , Terapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Paclitaxel/administração & dosagem , Paclitaxel/efeitos adversos , Estudos Retrospectivos , Taxa de Sobrevida , Neoplasias do Colo do Útero/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA