Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Funct Biomater ; 14(4)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37103294

RESUMO

The solid phase of a commercial calcium phosphate (Graftys® HBS) was combined with ovine or human blood stabilized either with sodium citrate or sodium heparin. The presence of blood delayed the setting reaction of the cement by ca. 7-15 h, depending on the nature of the blood and blood stabilizer. This phenomenon was found to be directly related to the particle size of the HBS solid phase, since prolonged grinding of the latter resulted in a shortened setting time (10-30 min). Even though ca. 10 h were necessary for the HBS blood composite to harden, its cohesion right after injection was improved when compared to the HBS reference as well as its injectability. A fibrin-based material was gradually formed in the HBS blood composite to end-up, after ca. 100 h, with a dense 3D organic network present in the intergranular space, thus affecting the microstructure of the composite. Indeed, SEM analyses of polished cross-sections showed areas of low mineral density (over 10-20 µm) spread in the whole volume of the HBS blood composite. Most importantly, when the two cement formulations were injected in the tibial subchondral cancellous bone in a bone marrow lesion ovine model, quantitative SEM analyses showed a highly significant difference between the HBS reference versus its analogue combined with blood. After a 4-month implantation, histological analyses clearly showed that the HBS blood composite underwent high resorption (remaining cement: ca. 13.1 ± 7.3%) and new bone formation (newly formed bone: 41.8 ± 14.7%). This was in sharp contrast with the case of the HBS reference for which a low resorption rate was observed (remaining cement: 79.0 ± 6.9%; newly formed bone: 8.6 ± 4.8%). This study suggested that the particular microstructure, induced by the use of blood as the HBS liquid phase, favored quicker colonization of the implant and acceleration of its replacement by newly formed bone. For this reason, the HBS blood composite might be worth considering as a potentially suitable material for subchondroplasty.

2.
J Biomed Mater Res B Appl Biomater ; 109(1): 102-116, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32700831

RESUMO

In the field of bone regenerative medicine, injectable calcium phosphate cements (CPCs) are used for decades in clinics, as bone void fillers. Most often preformed polymers (e.g., hyaluronic acid, collagen, chitosan, cellulose ethers…) are introduced in the CPC formulation to make it injectable and improve its cohesion. Once the cement has hardened, the polymer is simply trapped in the CPC structure and no organic subnetwork is present. By contrast, in this work a CPC was combined with organic monomers that reticulated in situ so that a continuous biocompatible 3D polymeric subnetwork was formed in the CPC microstructure, resulting in a higher permeability of the CPC, which might allow to accelerate its in vivo degradation. Two options were investigated depending on whether the polymer was formed before the apatitic inorganic network or concomitantly. In the former case, conditions were found to reach a suitable rheology for easy injection of the composite. In addition, the in situ formed polymer was shown to strongly affect the size, density, and arrangement of the apatite crystals formed during the setting reaction, thereby offering an original route to modulate the microstructure and porosity of apatitic cements.


Assuntos
Apatitas/química , Materiais Biocompatíveis/química , Cimentos Ósseos/química , Substitutos Ósseos/química , Hidrogéis/química , Regeneração Óssea , Osso e Ossos , Força Compressiva , Humanos , Injeções , Teste de Materiais , Porosidade
3.
J Biomed Mater Res B Appl Biomater ; 108(2): 367-376, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31033211

RESUMO

The in vivo resorption rate of two injectable apatitic calcium phosphate cements used in clinics (Graftys® HBS and NORIAN®) was compared, using a good laboratory practice (GLP) study based on an animal model of critical-sized bone defect. To rationalize the markedly different biological properties observed for both cements, key physical features were investigated, including permeability and water-accessible porosity, total porosity measured by mercury intrusion and gravimetry, and microstructure. Due to a different concept for creating porosity between the two cements investigated in this study, a markedly different microstructural arrangement of apatite crystals was observed in the intergranular space, which was found to significantly influence both the mechanical strength and in vivo degradation of the two calcium phosphate cements.


Assuntos
Apatitas/química , Apatitas/metabolismo , Cimentos Ósseos/química , Cimentos Ósseos/metabolismo , Alicerces Teciduais/química , Animais , Transplante Ósseo , Carbonato de Cálcio/química , Força Compressiva , Feminino , Derivados da Hipromelose/química , Técnicas In Vitro , Injeções , Teste de Materiais , Microesferas , Permeabilidade , Polissacarídeos/química , Porosidade , Coelhos , Solubilidade , Engenharia Tecidual
4.
J Biomed Mater Res B Appl Biomater ; 106(8): 2786-2795, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29226553

RESUMO

An injectable purely apatitic calcium phosphate cement (CPC) was successfully combined to a water-soluble radiopaque agent (i.e., Xenetix® ), to result in an optimized composition that was found to be as satisfactory as poly(methyl methacrylate) (PMMA) formulations used for vertebroplasty, in terms of radiopacity, texture and injectability. For that purpose, the Xenetix dosage in the cement paste was optimized by injection of the radiopaque CPC in human cadaveric vertebrae under classical PMMA vertebroplasty conditions, performed by interventional radiologists familiar with this surgical procedure. When present in the cement paste up to 70 mg I mL-1 , Xenetix did not influence the injectability, cohesion, and setting time of the resulting composite. After hardening of the material, the same observation was made regarding the microstructure, mechanical strength and alpha-tricalcium phosphate to calcium deficient apatite transformation rate. Upon implantation in bone in a small animal model (rat), the biocompatibility of the Xenetix-containing CPC was evidenced. Moreover, an almost quantitative release of the contrast agent was found to occur rapidly, on the basis of in vitro static and dynamic quantitative studies simulating in vivo implantation. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2786-2795, 2018.


Assuntos
Apatitas , Cimentos Ósseos , Meios de Contraste , Teste de Materiais , Coluna Vertebral , Vertebroplastia/métodos , Animais , Apatitas/química , Apatitas/farmacologia , Cimentos Ósseos/química , Cimentos Ósseos/farmacologia , Meios de Contraste/química , Meios de Contraste/farmacologia , Humanos , Masculino , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Ratos , Ratos Endogâmicos Lew , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia
5.
Acta Biomater ; 62: 328-339, 2017 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-28864250

RESUMO

Two commercial formulations of apatitic calcium phosphate cements (CPCs), Graftys® Quickset (QS) and Graftys® HBS (HBS), similar in composition but with different initial setting time (7 and 15min, respectively), were combined to ovine whole blood. Surprisingly, although a very cohesive paste was obtained after a few minutes, the setting time of the HBS/blood composite dramatically delayed when compared to its QS analogue and the two blood-free references. Using solid state NMR, scanning electron microscopy and high frequency impedance measurements, it was shown that, in the particular case of the HBS/blood composite, formation of a reticulated and porous organic network occurred in the intergranular space, prior to the precipitation of apatite crystals driven by the cement setting process. The resulting microstructure conferred unique biological properties to this material upon implantation in bone defects, since its degradation rate after 4 and 12weeks was more than twice that for the three other CPCs, with a significant replacement by newly formed bone. STATEMENT OF SIGNIFICANCE: A major challenge in the design of bone graft substitutes is the development of injectable, cohesive, resorbable and self-setting calcium phosphate cement (CPC) that enables rapid cell invasion with initial mechanical properties as close as bone ones. Thus, we describe specific conditions in CPC-blood composites where the formation of a 3D clot-like network can interact with the precipitated apatite crystals formed during the cement setting process. The resulting microstructure appears more ductile at short-term and more sensitive to biological degradation which finally promotes new bone formation. This important and original paper reports the design and in-depth chemical and physical characterization of this groundbreaking technology.


Assuntos
Apatitas , Cimentos Ósseos , Cerâmica , Teste de Materiais , Osteogênese/efeitos dos fármacos , Animais , Apatitas/química , Apatitas/farmacologia , Cimentos Ósseos/química , Cimentos Ósseos/farmacologia , Cerâmica/química , Cerâmica/farmacologia , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA