Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38030358

RESUMO

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Trombose , Humanos , Feminino , Incidência , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/etiologia
2.
Catheter Cardiovasc Interv ; 102(2): 328-338, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393603

RESUMO

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is a less invasive therapeutic option compared with redo surgical valve replacement for high-risk patients. Relative to procedures within stented surgical valves, VIV-TAVI within stentless valves is associated with a higher complication rate due to challenging underlying anatomy and absence of fluoroscopic landmarks. AIMS: We share a single-center experience with VIV-TAVI in stentless valves, discussing our procedural insights and associated outcomes. METHODS: Our institutional database was queried, and 25 patients who had undergone VIV-TAVI within a stentless bioprosthesis, homograft, or valve-sparing aortic root replacement between 2013 and 2022 were found. Outcome endpoints were based on the Valve Academic Research Consortium-3 criteria. RESULTS: The mean age of the cohort was 69.5 ± 13.6 years. VIV implantation was performed within a homograft in 11 patients, a stentless bioprothesis in 10 patients, and a valve-sparing aortic root replacement in 4 patients. Nineteen (76%) balloon-expandable valves, 5 (20%) self-expanding valves, and one mechanically-expandable (4%) valve were implanted with 100% procedural success, with no instances of significant paravalvular leak, coronary occlusion, or device embolization. There was one (4%) in-hospitality mortality after an emergency procedure; one (4%) patient experienced a transient ischemic attack; and two (8%) patients required permanent pacemaker implantation. The median length of hospital stay was 2 days. After a median follow-up time of 16.5 months, valve function was acceptable in all patients with available data. CONCLUSION: VIV-TAVI within stentless valves can be safely performed with methodical procedural technique and can provide clinical benefit in patients at high reoperation risk.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia
5.
Anat Sci Int ; 96(4): 517-523, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34053001

RESUMO

The sternal foramen, usually an asymptomatic osteological defect, can lead to catastrophic consequences if not recognized prior to certain medical procedures. This study reports the prevalence of a sternal foramen in two South Amerindian populations compared with other published populations. We evaluated the presence of sternal foramina using thoracic computed tomography scans of 1334 (48% female) participants from two indigenous populations of Bolivia (n = 900 Tsimane, 434 Moseten). The prevalence of sternal foramina was compared to two U.S. populations of similar sex/age distribution (n = 572 Midwest Americans, 131 self-identified Native North Americans) via similar CT scans. A sternal foramen was significantly more common in the two Bolivian populations (prevalence ranging from 12.8 to 13.4%), compared to 4.4-5.1% in the two U.S. groups, consistent with prior estimates in studies from industrialized populations. Males had higher frequency of a sternal foramen compared to females in each of the four groups (OR = 1.904, 95% CI: 1.418-2.568, p < 0.001). Age was not associated with sternal foramen presence. These data show both a higher rate of sternal foramina in the South Amerindian populations versus comparator populations in North America and the highest rate of any studied living population. Although it is not possible to determine from our data the relative contribution of genetics versus early life or environmental causes to the higher rates of sternal foramen, we note that small prior studies have likewise demonstrated a higher prevalence in lower income countries. Further determination of the contributing factors warrants greater investigation and research.


Assuntos
Anormalidades Congênitas/epidemiologia , Esterno/anormalidades , Adulto , Idoso , Idoso de 80 Anos ou mais , Bolívia , Anormalidades Congênitas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Esterno/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA