Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Phys Rev E ; 106(2-2): 025202, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36109932

RESUMO

An inertial fusion implosion on the National Ignition Facility, conducted on August 8, 2021 (N210808), recently produced more than a megajoule of fusion yield and passed Lawson's criterion for ignition [Phys. Rev. Lett. 129, 075001 (2022)10.1103/PhysRevLett.129.075001]. We describe the experimental improvements that enabled N210808 and present the first experimental measurements from an igniting plasma in the laboratory. Ignition metrics like the product of hot-spot energy and pressure squared, in the absence of self-heating, increased by ∼35%, leading to record values and an enhancement from previous experiments in the hot-spot energy (∼3×), pressure (∼2×), and mass (∼2×). These results are consistent with self-heating dominating other power balance terms. The burn rate increases by an order of magnitude after peak compression, and the hot-spot conditions show clear evidence for burn propagation into the dense fuel surrounding the hot spot. These novel dynamics and thermodynamic properties have never been observed on prior inertial fusion experiments.

2.
Phys Rev E ; 106(2-2): 025201, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36110025

RESUMO

We present the design of the first igniting fusion plasma in the laboratory by Lawson's criterion that produced 1.37 MJ of fusion energy, Hybrid-E experiment N210808 (August 8, 2021) [Phys. Rev. Lett. 129, 075001 (2022)10.1103/PhysRevLett.129.075001]. This design uses the indirect drive inertial confinement fusion approach to heat and compress a central "hot spot" of deuterium-tritium (DT) fuel using a surrounding dense DT fuel piston. Ignition occurs when the heating from absorption of α particles created in the fusion process overcomes the loss mechanisms in the system for a duration of time. This letter describes key design changes which enabled a ∼3-6× increase in an ignition figure of merit (generalized Lawson criterion) [Phys. Plasmas 28, 022704 (2021)1070-664X10.1063/5.0035583, Phys. Plasmas 25, 122704 (2018)1070-664X10.1063/1.5049595]) and an eightfold increase in fusion energy output compared to predecessor experiments. We present simulations of the hot-spot conditions for experiment N210808 that show fundamentally different behavior compared to predecessor experiments and simulated metrics that are consistent with N210808 reaching for the first time in the laboratory "ignition."

3.
Phys Rev Lett ; 128(6): 065003, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35213202

RESUMO

A hologram fully encodes a three-dimensional light field by imprinting the interference between the field and a reference beam in a recording medium. Here we show that two collinear pump lasers with different foci overlapped in a gas jet produce a holographic plasma lens capable of focusing or collimating a probe laser at intensities several orders-of-magnitude higher than the limits of a nonionized optic. We outline the theory of these diffractive plasma lenses and present simulations for two plasma mechanisms that allow their construction: spatially varying ionization and ponderomotively driven ion-density fluctuations. Damage-resistant plasma optics are necessary for manipulating high-intensity light, and divergence control of high-intensity pulses-provided by holographic plasma lenses-will be a critical component of high-power plasma-based lasers.

4.
Phys Rev Lett ; 126(20): 205001, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34110194

RESUMO

Slow and fast light, or large changes in the group velocity of light, have been observed in a range of optical media, but the fine optical control necessary to induce an observable effect has not been achieved in a plasma. Here, we describe how the ion-acoustic response in a fully ionized plasma can produce large and measurable changes in the group velocity of light. We show the first experimental demonstration of slow and fast light in a plasma, measuring group velocities between 0.12c and -0.34c.

5.
Phys Rev E ; 103(5-1): 053207, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34134339

RESUMO

We report on the increase in the accelerated electron number and energy using compound parabolic concentrator (CPC) targets from a short-pulse (∼150 fs), high-intensity (>10^{18} W/cm^{2}), and high-contrast (∼10^{8}) laser-solid interaction. We report on experimental measurements using CPC targets where the hot-electron temperature is enhanced up to ∼9 times when compared to planar targets. The temperature measured from the CPC target is 〈T_{e}〉=4.4±1.3 MeV. Using hydrodynamic and particle in cell simulations, we identify the primary source of this temperature enhancement is the intensity increase caused by the CPC geometry that focuses the laser, reducing the focal spot and therefore increasing the intensity of the laser-solid interaction, which is also consistent with analytic expectations for the geometrical focusing.

6.
Phys Rev E ; 103(3-1): 033203, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33862755

RESUMO

The generation of hot, directional electrons via laser-driven stimulated Raman scattering (SRS) is a topic of great importance in inertial confinement fusion (ICF) schemes. Little recent research has been dedicated to this process at high laser intensity, in which back, side, and forward scatter simultaneously occur in high energy density plasmas, of relevance to, for example, shock ignition ICF. We present an experimental and particle-in-cell (PIC) investigation of hot electron production from SRS in the forward and near-forward directions from a single speckle laser of wavelength λ_{0}=1.053µm, peak laser intensities in the range I_{0}=0.2-1.0×10^{17}Wcm^{-2} and target electron densities between n_{e}=0.3-1.6%n_{c}, where n_{c} is the plasma critical density. As the intensity and density are increased, the hot electron spectrum changes from a sharp cutoff to an extended spectrum with a slope temperature T=34±1keV and maximum measured energy of 350 keV experimentally. Multidimensional PIC simulations indicate that the high energy electrons are primarily generated from SRS-driven electron plasma wave phase fronts with k vectors angled ∼50^{∘} with respect to the laser axis. These results are consistent with analytical arguments that the spatial gain is maximized at an angle which balances the tendency for the growth rate to be larger for larger scattered light wave angles until the kinetic damping of the plasma wave becomes important. The efficiency of generated high energy electrons drops significantly with a reduction in either laser intensity or target electron density, which is a result of the rapid drop in growth rate of Raman scattering at angles in the forward direction.

7.
Rev Sci Instrum ; 92(3): 033511, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820108

RESUMO

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm-352 nm), stimulated Raman scattering (430 nm-760 nm), and ω/2 (695 nm-745 nm). SLTD measures scattered light with a time resolution of ∼1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

8.
Sci Rep ; 11(1): 7498, 2021 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-33820945

RESUMO

Laser-plasma accelerators (LPAs) driven by picosecond-scale, kilojoule-class lasers can generate particle beams and x-ray sources that could be utilized in experiments driven by multi-kilojoule, high-energy-density science (HEDS) drivers such as the OMEGA laser at the Laboratory for Laser Energetics (LLE) or the National Ignition Facility at Lawrence Livermore National Laboratory. This paper reports on the development of the first LPA driven by a short-pulse, kilojoule-class laser (OMEGA EP) connected to a multi-kilojoule HEDS driver (OMEGA). In experiments, electron beams were produced with electron energies greater than 200 MeV, divergences as low as 32 mrad, charge greater than 700 nC, and conversion efficiencies from laser energy to electron energy up to 11%. The electron beam charge scales with both the normalized vector potential and plasma density. These electron beams show promise as a method to generate MeV-class radiography sources and improved-flux broadband x-ray sources at HEDS drivers.

9.
Rev Sci Instrum ; 91(9): 093505, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33003822

RESUMO

Proton radiography is a well-established technique for measuring electromagnetic fields in high-energy-density plasmas. Fusion reactions producing monoenergetic particles, such as D3He, are commonly used as a source, produced by a capsule implosion. Using smaller capsules for radiography applications is advantageous as the source size decreases, but on the National Ignition Facility (NIF), this can introduce complications from increasing blow-by light, since the phase plate focal spot size is much larger than the capsules. We report a demonstration of backlighter targets where a "Saturn" ring is placed around the capsule to block this light. The nuclear performance of the backlighters is unperturbed by the addition of a ring. We also test a ring with an equatorial cutout, which severely affects the proton emission and is not viable for radiography applications. These results demonstrate the general viability of Saturn ring backlighter targets for use on the NIF.

11.
Rev Sci Instrum ; 90(3): 033503, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927775

RESUMO

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35-100 keV, and 60-1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 1010 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

12.
Phys Rev E ; 99(3-1): 033203, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30999431

RESUMO

Raman side scatter, whereby scattered light is resonant while propagating perpendicularly to a density gradient in a plasma, was identified experimentally in planar-target experiments at the National Ignition Facility at intensities orders of magnitudes below the threshold for absolute instability. We have derived a new theoretical description of convective Raman side scatter below the absolute threshold, validated by numerical simulations. We show that inertial confinement fusion experiments at full ignition scale, i.e., with mm-scale spot sizes and density scale lengths, are prone to increased coupling losses from Raman side scatter as the instability can extend from the absolute regime near the quarter-critical density to the convective regime at lower electron densities.

13.
Sci Rep ; 9(1): 3249, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30824838

RESUMO

Laser-wakefield accelerators (LWFAs) are high acceleration-gradient plasma-based particle accelerators capable of producing ultra-relativistic electron beams. Within the strong focusing fields of the wakefield, accelerated electrons undergo betatron oscillations, emitting a bright pulse of X-rays with a micrometer-scale source size that may be used for imaging applications. Non-destructive X-ray phase contrast imaging and tomography of heterogeneous materials can provide insight into their processing, structure, and performance. To demonstrate the imaging capability of X-rays from an LWFA we have examined an irregular eutectic in the aluminum-silicon (Al-Si) system. The lamellar spacing of the Al-Si eutectic microstructure is on the order of a few micrometers, thus requiring high spatial resolution. We present comparisons between the sharpness and spatial resolution in phase contrast images of this eutectic alloy obtained via X-ray phase contrast imaging at the Swiss Light Source (SLS) synchrotron and X-ray projection microscopy via an LWFA source. An upper bound on the resolving power of 2.7 ± 0.3 µm of the LWFA source in this experiment was measured. These results indicate that betatron X-rays from laser wakefield acceleration can provide an alternative to conventional synchrotron sources for high resolution imaging of eutectics and, more broadly, complex microstructures.

14.
Phys Rev Lett ; 123(25): 254801, 2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31922780

RESUMO

Single-shot absorption measurements have been performed using the multi-keV x rays generated by a laser-wakefield accelerator. A 200 TW laser was used to drive a laser-wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of ≈15 mrad FWHM. Betatron oscillations of these electrons generated 1.2±0.2×10^{6} photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300∶1. This was sufficient to allow high-resolution x-ray absorption near-edge structure measurements at the K edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with density functional theory simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration x-ray pulse synchronized to a high-power laser will enable key advances in the study of ultrafast energetic processes such as electron-ion equilibration.

15.
Rev Sci Instrum ; 89(10): 10F116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399768

RESUMO

Large quantities of ultrahigh-energy x-rays are produced by petawatt-class lasers; however, spectroscopy in this range of 0.1-1 MeV is difficult due to the long photon mean free path. A novel geometry step filter to measure the high-energy bremsstrahlung emission tail has been developed for use in high energy density, short-pulse laser-matter interaction experiments. The grid design of the filters allows for the independent determination of a local background, which reduces systematic errors in the reconstructed spectra. This spectrometer was used to measure x-ray spectra for various laser and target conditions at intensities near 1 × 1018 W/cm2 where single-exponential bremsstrahlung spectra were fit to the data and show an increasing photon temperature with pulse duration for a fixed laser intensity.

16.
Rev Sci Instrum ; 89(10): 10I145, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399771

RESUMO

Experiments using the Advanced Radiographic Capability (ARC) laser at the National Ignition Facility (NIF) aim to characterize short-pulse-driven proton beams for use as both probes and drivers for high-energy-density physics experiments. Measurements of ARC-driven proton beam characteristics, such as energy spectrum and conversion efficiency, rely on the NIF Electron Positron Proton Spectrometer (NEPPS). The NEPPS diagnostic is a version of an existing particle spectrometer which is used for detecting MeV electron and positron spectra via permanent magnetic field dispersion. These spectrometers have not yet been calibrated for protons and instead use an analytical calculation to estimate the dispersion. Small variations in the field uniformity can affect the proton dispersion due to the relatively small resolving power (E/dE) for this diagnostic. A broadband energy, laser-accelerated proton source was produced at the Titan laser to experimentally calibrate the proton dispersion. These experimental data were used to test the theoretical dispersion. Numerical simulations using measurements of the magnetic field variation within the diagnostic were used to obtain a realistic proton dispersion curve for the new NEPPS units. This procedure for obtaining each independent dispersion is applicable to all EPPS and NEPPS diagnostics, given the axial magnetic field profile.

17.
Injury ; 49(12): 2186-2192, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30270012

RESUMO

Injury deaths have a major impact on public health systems, particularly in the Latin American region; however, little is known about how different drugs, in combination or not with alcohol, interact with each injury type. We tested an epidemiological protocol for investigating alcohol and other drug acute use among fatally injured victims taking into account the injury context for all injury causes in Sao Paulo, Brazil. Blood alcohol and drug content were fully screened and confirmed following a probability sample selection of decedents (n = 365) during 19 consecutive months (2014-2015). Drug concentrations, including benzodiazepines, cannabis, cocaine, and opioids were determined by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography tandem mass spectrometry (LC-MS/MS). Toxicology data were interpreted in combination with injury context retrieved from police records regarding cause, place of injury, and victims' criminal history. More than half of all fatally injured victims studied were under the influence of at least one substance (55.3%). Alcohol was the leading substance consumed before a fatal injury event (30.1%), followed by cocaine (21.9%) and cannabis (14%). Illicit drug use (cocaine and cannabis) comprised more than two thirds of all drug-related deaths. Alcohol-positive deaths are over-represented among road traffic injuries, while drug-positive deaths are more prevalent among intentional injuries. Victims who had previous criminal convictions were significantly more likely to have used illicit drugs compared to those who did not have a criminal background. We estimated that one in every two fatal injuries in the city of Sao Paulo is associated with acute substance use by the victim. The health burden attributed to alcohol- and drug-related fatal injury events has reached significant higher levels in Latin American cities such as Sao Paulo compared globally.


Assuntos
Consumo de Bebidas Alcoólicas/efeitos adversos , Drogas Ilícitas/efeitos adversos , Transtornos Relacionados ao Uso de Substâncias/mortalidade , Ferimentos e Lesões/mortalidade , Adolescente , Adulto , Consumo de Bebidas Alcoólicas/sangue , Concentração Alcoólica no Sangue , Brasil/epidemiologia , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Inquéritos Epidemiológicos , Humanos , Drogas Ilícitas/sangue , Masculino , Pessoa de Meia-Idade , Prevalência , Detecção do Abuso de Substâncias , Transtornos Relacionados ao Uso de Substâncias/sangue , Ferimentos e Lesões/sangue
18.
Sci Rep ; 8(1): 3165, 2018 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-29453363

RESUMO

We experimentally demonstrate that plasma waveguides produced with ultra-short laser pulses (sub-picosecond) in gas jets are capable of guiding high intensity laser pulses. This scheme has the unique ability of guiding a high-intensity laser pulse in a plasma waveguide created by the same laser system in the very simple and stable experimental setup. A hot plasma column was created by a femtosecond class laser that expands into an on-axis parabolic low density profile suitable to act as a waveguide for high intensity laser beams. We have successfully guided ~1015 W cm-2 laser pulses in a 8 mm long hydrogen plasma waveguide with a 35% guiding efficiency.

19.
Sci Rep ; 7(1): 2399, 2017 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-28546551

RESUMO

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1-100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from "noise", arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr-1, and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm-1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr-1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

20.
Phys Rev Lett ; 118(13): 134801, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28409970

RESUMO

We investigate a new regime for betatron x-ray emission that utilizes kilojoule-class picosecond lasers to drive wakes in plasmas. When such laser pulses with intensities of ∼5×10^{18} W/cm^{2} are focused into plasmas with electron densities of ∼1×10^{19} cm^{-3}, they undergo self-modulation and channeling, which accelerates electrons up to 200 MeV energies and causes those electrons to emit x rays. The measured x-ray spectra are fit with a synchrotron spectrum with a critical energy of 10-20 keV, and 2D particle-in-cell simulations were used to model the acceleration and radiation of the electrons in our experimental conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA