Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(12): e0289052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38150442

RESUMO

BACKGROUND: Blood pressure, grip strength and lung function are frequently assessed in longitudinal population studies, but the measurement devices used differ between studies and within studies over time. We aimed to compare measurements ascertained from different commonly used devices. METHODS: We used a randomised cross-over study. Participants were 118 men and women aged 45-74 years whose blood pressure, grip strength and lung function were assessed using two sphygmomanometers (Omron 705-CP and Omron HEM-907), four handheld dynamometers (Jamar Hydraulic, Jamar Plus+ Digital, Nottingham Electronic and Smedley) and two spirometers (Micro Medical Plus turbine and ndd Easy on-PC ultrasonic flow-sensor) with multiple measurements taken on each device. Mean differences between pairs of devices were estimated along with limits of agreement from Bland-Altman plots. Sensitivity analyses were carried out using alternative exclusion criteria and summary measures, and using multilevel models to estimate mean differences. RESULTS: The mean difference between sphygmomanometers was 3.9mmHg for systolic blood pressure (95% Confidence Interval (CI):2.5,5.2) and 1.4mmHg for diastolic blood pressure (95% CI:0.3,2.4), with the Omron HEM-907 measuring higher. For maximum grip strength, the mean difference when either one of the electronic dynamometers was compared with either the hydraulic or spring-gauge device was 4-5kg, with the electronic devices measuring higher. The differences were small when comparing the two electronic devices (difference = 0.3kg, 95% CI:-0.9,1.4), and when comparing the hydraulic and spring-gauge devices (difference = 0.2kg, 95% CI:-0.8,1.3). In all cases limits of agreement were wide. The mean difference in FEV1 between spirometers was close to zero (95% CI:-0.03,0.03), limits of agreement were reasonably narrow, but a difference of 0.47l was observed for FVC (95% CI:0.53,0.42), with the ndd Easy on-PC measuring higher. CONCLUSION: Our study highlights potentially important differences in measurement of key functions when different devices are used. These differences need to be considered when interpreting results from modelling intra-individual changes in function and when carrying out cross-study comparisons, and sensitivity analyses using correction factors may be helpful.


Assuntos
Determinação da Pressão Arterial , Força da Mão , Masculino , Humanos , Feminino , Pressão Sanguínea , Estudos Cross-Over , Força da Mão/fisiologia , Pulmão , Reprodutibilidade dos Testes
2.
J Frailty Sarcopenia Falls ; 6(4): 225-230, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34950813

RESUMO

Grip strength is commonly used to identify people with low muscle strength. It is unclear what impact the type of dynamometer used to measure grip strength has on the identification of low muscle strength so we aimed to assess this. Study participants were 118 men and women aged 45-74y from a randomised, repeated measurements cross-over study. Maximum grip strength was assessed using four hand-held dynamometers (Jamar Hydraulic; Jamar Plus+ Digital; Nottingham Electronic; Smedley) in a randomly allocated order. EWGSOP2 cut-points were applied to estimate prevalence of low muscle strength for each device. Agreement between devices was compared. Prevalence of low muscle strength varied by dynamometer ranging between 3% and 22% for men and, 3% and 15% for women. Of the 13 men identified as having low muscle strength by at least one of the four dynamometers, only 8% were identified by all four and 54% by just one. Of the 15 women classified as having low muscle strength by at least one of the four dynamometers, only 7% were identified by all four and 67% by only one. Variation in the measures of grip strength acquired by different hand-held dynamometers has potentially important implications when identifying low muscle strength.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA