Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Mayo Clin Proc ; 76(9): 950-2, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11560308

RESUMO

Clinicians who provide care for patients with implantable devices for rhythm management, ie, pacemakers and internal cardioverter defibrillators, must be aware of sources of interference that could affect device function. Intracardiac radiofrequency is a recognized source of potential interference. However, radiofrequency to extracardiac sites that are relatively close to the implanted device has not been investigated thoroughly. We present 2 patients with permanent pacemakers undergoing intrahepatic radiofrequency for the treatment of metastatic disease. No interference was documented in either patient. Additional in vitro and in vivo studies are needed to determine definite clinical guidelines for such patients.


Assuntos
Ablação por Cateter/métodos , Bloqueio Cardíaco/terapia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Marca-Passo Artificial , Idoso , Carcinoma de Células Renais/secundário , Carcinoma de Células Renais/cirurgia , Carcinoma de Células Escamosas/secundário , Carcinoma de Células Escamosas/cirurgia , Ablação por Cateter/efeitos adversos , Seguimentos , Humanos , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Medição de Risco
3.
Pacing Clin Electrophysiol ; 24(11): 1623-30, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11816631

RESUMO

The aim of this study was to evaluate the role of programmed ventricular stimulation and ICDs in patients with idiopathic dilated cardiomyopathy and syncope. Between 1990 and 1998, 54 (mean age 67+/-11 years, 76% men) patients presented with idiopathic dilated cardiomyopathy and syncope. An electrophysiological study was done in 37 of the 54 patients: 10 had inducible sustained monomorphic ventricular tachycardia, 12 had conduction system disease or neurocardiogenic syncope, and 15 had a normal study. Overall, 17 patients received an ICD, 15 patients received a pacemaker, and 22 patients received no device. Nine of the 15 patients with a negative electrophysiological study eventually received an ICD: 3 because they were considered high risk and 6 because of recurrent syncope or presyncope. In the 17 patients who received an ICD, incidence of appropriate shocks at 1 and 3 years was 47% and 74%, respectively, in the inducible sustained monomorphic ventricular tachycardia group, and 40% and 40%, respectively, in the group without inducible sustained monomorphic ventricular tachycardia (P = 0.29, log-rank test). In conclusion, programmed ventricular stimulation is not useful in risk stratification of patients with idiopathic dilated cardiomyopathy and syncope and may delay necessary ICD implantation.


Assuntos
Cardiomiopatia Dilatada/terapia , Técnicas Eletrofisiológicas Cardíacas/métodos , Marca-Passo Artificial , Síncope/terapia , Idoso , Cardiomiopatia Dilatada/mortalidade , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Análise de Sobrevida , Síncope/mortalidade