ArXiv ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37731661

RESUMO

Flexible needle insertion procedures are common for minimally-invasive surgeries for diagnosing and treating prostate cancer. Bevel-tip needles provide physicians the capability to steer the needle during long insertions to avoid vital anatomical structures in the patient and reduce post-operative patient discomfort. To provide needle placement feedback to the physician, sensors are embedded into needles for determining the real-time 3D shape of the needle during operation without needing to visualize the needle intra-operatively. Through expansive research in fiber optics, a plethora of bio-compatible, MRI-compatible, optical shape-sensors have been developed to provide real-time shape feedback, such as single-core and multicore fiber Bragg gratings. In this paper, we directly compare single-core fiber-based and multicore fiber-based needle shape-sensing through identically constructed, four-active area sensorized bevel-tip needles inserted into phantom and ex-vivo tissue on the same experimental platform. In this work, we found that for shape-sensing in phantom tissue, the two needles performed identically with a p-value of 0.164 > 0.05, but in ex-vivo real tissue, the single-core fiber sensorized needle significantly outperformed the multicore fiber configuration with a p-value of 0.0005 < 0.05. This paper also presents the experimental platform and method for directly comparing these optical shape sensors for the needle shape-sensing task, as well as provides direction, insight and required considerations for future work in constructively optimizing sensorized needles.

2.
Int Symp Med Robot ; 20232023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37292169

RESUMO

Bevel-tip needles are commonly utilized in percutaneous medical interventions where a curved insertion trajectory is required. To avoid deviation from the intended trajectory, needle shape sensing and tip localization is crucial in providing the operator with feedback. There is an abundance of previous work that investigate the medical application of fiber Bragg grating (FBG) sensors, but most works select only one specific type of fiber among the many available sensor options to integrate into their hardware designs. In this work, we compare two different types of FBG sensors under identical conditions and application, namely, acting as the sensor for needle insertion shape reconstruction. We built a three-channel single core needle and a seven-channel multicore fiber (MCF) needle and discuss the pros and cons of both constructions for shape sensing experiments into constant curvature jigs. The overall needle tip error is 1.23 mm for the single core needle and 2.08 mm for the multicore needle.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4397-4401, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086006

RESUMO

The determination of flexible needle shape during insertion is critical for planning and validation in minimally invasive surgical percutaneous procedures. In this paper, we validate a needle shape-sensing method using fiber Bragg grating (FBG) sensors over sequential needle insertion lengths in gel phantom and real tissue. Experiments on a four-active area, FBG-sensorized needle were performed in both isotropic simulated tissue and inhomogeneous animal tissue with computed tomography (CT) as the ground truth of the needle shape. The results show that the needle shape obtained from the FBG sensors has an overall consistent accuracy in real tissue in comparison to the phantom gel. The results validate a viable 3D needle shape-sensing model and reconstruction method over various insertion depths in comparison to the needle shapes determined from CT in both gel phantom and real tissue.


Assuntos
Agulhas , Tomografia Computadorizada por Raios X , Animais , Procedimentos Cirúrgicos Minimamente Invasivos , Imagens de Fantasmas
4.
IEEE Sens J ; 22(22): 22232-22243, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37216067

RESUMO

Flexible bevel-tipped needles are often used for needle insertion in minimally-invasive surgical techniques due to their ability to be steered in cluttered environments. Shapesensing enables physicians to determine the location of needles intra-operatively without requiring radiation of the patient, enabling accurate needle placement. In this paper, we validate a theoretical method for flexible needle shape-sensing that allows for complex curvatures, extending upon a previous sensor-based model. This model combines curvature measurements from fiber Bragg grating (FBG) sensors and the mechanics of an inextensible elastic rod to determine and predict the 3D needle shape during insertion. We evaluate the model's shape sensing capabilities in C- and S-shape insertions in single-layer isotropic tissue, and C-shape insertions in two-layer isotropic tissue. Experiments on a four-active area, FBG-sensorized needle were performed in varying tissue stiffnesses and insertion scenarios under stereo vision to provide the 3D ground truth needle shape. The results validate a viable 3D needle shape-sensing model accounting for complex curvatures in flexible needles with mean needle shape sensing root-mean-square errors of 0.160 ± 0.055 mm over 650 needle insertions.

5.
Rep U S ; 2022: 3505-3511, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36636257

RESUMO

Complex needle shape prediction remains an issue for planning of surgical interventions of flexible needles. In this paper, we validate a theoretical method for flexible needle shape prediction allowing for non-uniform curvatures, extending upon a previous sensor-based model which combines curvature measurements from fiber Bragg grating (FBG) sensors and the mechanics of an inextensible elastic rod to determine and predict the 3D needle shape during insertion. We evaluate the model's effectiveness in single-layer isotropic tissue for shape sensing and shape prediction capabilities. Experiments on a four-active area, FBG-sensorized needle were performed in varying single-layer isotropic tissues under stereo vision to provide 3D ground truth of the needle shape. The results validate a viable 3D needle shape prediction model accounting for non-uniform curvatures in flexible needles with mean needle shape sensing and prediction root-mean-square errors of 0.479 mm and 0.892 mm, respectively.

6.
Int Symp Med Robot ; 20212021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35187545

RESUMO

There has been much research exploring the use of fiber Bragg grating (FBG)-sensorized needles in the prostate biopsy procedure, but all FBG needles used in the research need to be calibrated, which is time consuming and prone to human errors. In this work, a semi-automatic robotic system was developed to perform FBG needle calibration. Compared to manual calibration results, the robotic system is able to calibrate FBG needles with the similar level of accuracy as achieved by an experienced manual operator, thus reducing the time cost during the needle calibration process.

7.
Proc IEEE Sens ; 20202020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34149973

RESUMO

Several models incorporate needle shape prediction, however prediction in multi-layer tissue for complex needle shape remains an issue. In this work, we present a method for trajectory generation of flexible needles that allows for complex curvatures, extending upon a previous sensor-based model. This model combines curvature measurements from fiber Bragg grating (FBG) sensors and the mechanics of an inextensible elastic rod for shape-sensing. We evaluate the method's effectiveness in single- and double-layer isotropic tissue prediction. The results illustrate a valid trajectory generation method accounting for complex curvatures in flexible needles.