Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(16): e35870, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39220996

RESUMO

Vibration control is extremely important for countless mechanical systems. Inerter is a two-terminal dynamic element proposed in 2002, based on analogy between mechanical system and electric system. Dynamic characteristic of an ideal inerter is pure inertia. Force applied on each terminal of an inerter is directly proportional to relative acceleration of two terminals. Since inerter was put forward, it has made significant progress in vibration control systems. The paper is a review about physical realizations of inerter as well as inerter-based vibration control. Physical realizations and applications in vibration control of inerter are focused. First, the develop of inerter and typical physical realizations of inerter are introduced. The normative derivation processes based on Lagrange equation method of the dynamic relationships in the different inerters are summarized. And then, three categories of common inerter-based vibration control systems are explained. Finally, research trend of physical realizations of inerter are summarized, and the possible researches on inerter-based vibration control are discussed.

2.
Small ; 20(30): e2311715, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38396319

RESUMO

Interface modification plays an important role in improving the power conversion efficiency (PCE) of organic solar cells (OSCs). However, the low non-covalent interaction between the cathode interface layer (CIL) and nonfullerene acceptor (NFA) directly affects the charge collection of OSCs. Here, the non-covalent interaction between the CIL and NFA is enhanced by introducing the 2D vermiculite (VML) in the poly(9,9-bis(3'-(N,N-dimethyl)-Nethylammonium-propyl-2,7-fluorene)-alt-2,7-(9,9-dioctylfluorene)) dibromide (PFN-Br) interface layer to form an efficient electron transport channel. As a result, the electron extraction efficiency from the active layer to the CIL is increased, and the PCE of OSCs based on PBDB-T:ITIC is boosted from 10.87% to 12.89%. In addition, the strategy of CIL doping VML is proven to be universal in different CIL materials, for which the PCE is boosted from 10.21% to 11.57% for OSCs based on PDINN and from 9.82% to 11.27% for OSCs based on PNDIT-F3N. The results provide a viable option for designing efficient CIL for high-performance non-fullerene OSCs, which may promote the commercialization of OSCs.

3.
Front Neural Circuits ; 14: 11, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32296310

RESUMO

Objective: To investigate whether the CSF-contacting nucleus receives brainstem and spinal cord projections and to understand the functional significance of these connections. Methods: The retrograde tracer cholera toxin B subunit (CB) was injected into the CSF-contacting nucleus in Sprague-Dawley rats according the previously reported stereotaxic coordinates. After 7-10 days, these rats were perfused and their brainstem and spinal cord were sliced (thickness, 40 µm) using a freezing microtome. All the sections were subjected to CB immunofluorescence staining. The distribution of CB-positive neuron in different brainstem and spinal cord areas was observed under fluorescence microscope. Results: The retrograde labeled CB-positive neurons were found in the midbrain, pons, medulla oblongata, and spinal cord. Four functional areas including one hundred and twelve sub-regions have projections to the CSF-contacting nucleus. However, the density of CB-positive neuron distribution ranged from sparse to dense. Conclusion: Based on the connectivity patterns of the CSF-contacting nucleus receives anatomical inputs from the brainstem and spinal cord, we preliminarily conclude and summarize that the CSF-contacting nucleus participates in pain, visceral activity, sleep and arousal, emotion, and drug addiction. The present study firstly illustrates the broad projections of the CSF-contacting nucleus from the brainstem and spinal cord, which implies the complicated functions of the nucleus especially for the unique roles of coordination in neural and body fluids regulation.


Assuntos
Tronco Encefálico/química , Líquido Cefalorraquidiano/química , Conectoma/métodos , Imageamento Tridimensional/métodos , Medula Espinal/química , Núcleo do Nervo Abducente/química , Núcleo do Nervo Abducente/citologia , Núcleo do Nervo Abducente/fisiologia , Animais , Tronco Encefálico/citologia , Tronco Encefálico/fisiologia , Aqueduto do Mesencéfalo/química , Aqueduto do Mesencéfalo/citologia , Aqueduto do Mesencéfalo/fisiologia , Líquido Cefalorraquidiano/fisiologia , Vias Neurais/química , Vias Neurais/citologia , Vias Neurais/fisiologia , Ratos , Ratos Sprague-Dawley , Medula Espinal/citologia , Medula Espinal/fisiologia , Núcleos Vestibulares/química , Núcleos Vestibulares/citologia , Núcleos Vestibulares/fisiologia
4.
Front Neuroanat ; 14: 7, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32180709

RESUMO

Objective: To investigate the projections the cerebrospinal fluid-contacting (CSF-contacting) nucleus receives from the diencephalon and to speculate on the functional significance of these connections. Methods: The retrograde tracer cholera toxin B subunit (CB) was injected into the CSF-contacting nucleus in SD rats according to the experimental formula of the stereotaxic coordinates. Animals were perfused 7-10 days after the injection, and the diencephalon was sliced at 40 µm with a freezing microtome. CB-immunofluorescence was performed on all diencephalic sections. The features of CB-positive neuron distribution in the diencephalon were observed with a fluorescence microscope. Results: The retrograde labeled CB-positive neurons were found in the epithalamus, subthalamus, and hypothalamus. Three functional diencephalic areas including 43 sub-regions revealed projections to the CSF-contacting nucleus. The CB-positive neurons were distributed in different density ranges: sparse, moderate, and dense. Conclusion: Based on the connectivity patterns of the CSF-contacting nucleus that receives anatomical inputs from the diencephalon, we preliminarily assume that the CSF-contacting nucleus participates in homeostasis regulation, visceral activity, stress, emotion, pain and addiction, and sleeping and arousal. The present study firstly illustrates the broad projections of the CSF-contacting nucleus from the diencephalon, which implies the complicated functions of the nucleus especially for the unique roles of coordination in neural and body fluids regulations.

5.
Front Neuroanat ; 13: 47, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31143102

RESUMO

A unique nucleus, the cerebrospinal fluid (CSF)-contacting nucleus, has recently been recognized in the brain parenchyma. The outstanding feature of this nucleus is that the neural somas are located in the parenchyma, but their processes stretch into the CSF, implying that it may be a key structure bridging the nervous and body fluids-regulating systems and may play a pivotal role in modulating physiological activities. However, the true biological significance of this nucleus needs to be uncovered. The morphology of a nucleus is one of the most important parameters for neuroscience studies. For this reason, a common experimental animal, Sprague-Dawley (SD) rats, was chosen. The position, adjacent structures, neuronal distribution, size, three-dimensional reconstruction, and core coordinates of the CSF-contacting nucleus in SD rats of different weights (90-400 g) were illustrated for the first time. Furthermore, the formulas for calculating the core coordinates of the CSF-contacting nucleus in rats of different weights were revealed. Finally, the possible biological functions uncovered by past research are reviewed in this paper. This study provides an indispensable methodology and a significant reference for researchers interested in this unique nucleus.

6.
Soft Matter ; 11(19): 3884-99, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25864524

RESUMO

Droplet-based microfluidic devices have received extensive attention in the fields of chemical synthesis, biochemical analysis, lab-on-chip devices, etc. Conventional passive microfluidic hydrodynamic flow-focusing devices (HFFDs) control the droplet breakup process by manipulating the flow ratios of the continuous phase to the dispersed phase. They confront difficulties in controlling droplet sizes in the dripping regime especially when the dispersed phase has a large viscosity. Previous studies have reported that an external electric field can be utilized as an additional tool to control the droplet breakup process in microfluidic devices. In this computational fluid dynamics (CFD) study, we have investigated the effect of an external static electric field on the droplet breakup process using the conservative level-set method coupled with the electrostatic model. The numerical simulations have demonstrated that the interaction of the electric field and the electric charges on the fluid interface induces the electric force, which plays a significant role in controlling the droplet formation dynamics. If the microfluidic system is applied with the electric field of varying strength, the droplet breakup process experiences three distinct regimes. In Regime 1, where low electric voltages are applied, the droplet size decreases almost linearly with the increase of voltage. Then the droplet size increases with the applied voltages in Regime 2, where the electric field has moderate strength. In Regime 3, where very large voltages are applied, the droplet size decreases with the applied voltage again. These interesting variations in the droplet breakup processes are explained by using transient pressure profiles in the dispersed phase and the continuous phase. The droplet breakup processes regulated by an external electric field that are revealed in this study can provide useful guidance on the design and operations of such droplet-based systems.

7.
Biomicrofluidics ; 8(5): 054125, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25538812

RESUMO

Droplet-based microfluidics has gained extensive research interest as it overcomes several challenges confronted by conventional single-phase microfluidics. The mixing performance inside droplets/slugs is critical in many applications such as advanced material syntheses and in situ kinetic measurements. In order to understand the effects of operating conditions on the mixing performance inside liquid slugs generated by a microfluidic T-junction, we have adopted the volume of fluid method coupled with the species transport model to study and quantify the mixing efficiencies inside slugs. Our simulation results demonstrate that an efficient mixing process is achieved by the intimate collaboration of the twirling effect and the recirculating flow. Only if the reagents are distributed transversely by the twirling effect, the recirculating flow can bring in convection mechanism thus facilitating mixing. By comparing the mixing performance inside slugs at various operating conditions, we find that slug size plays the key role in influencing the mixing performance as it determines the amount of fluid to be distributed by the twirling effect. For the cases where short slugs are generated, the mixing process is governed by the fast convection mechanism because the twirling effect can distribute the fluid to the flow path of the recirculating flow effectively. For cases with long slugs, the mixing process is dominated by the slow diffusion mechanism since the twirling effect is insufficient to distribute the large amount of fluid. In addition, our results show that increasing the operating velocity has limited effects on improving the mixing performance. This study provides the insight of the mixing process and may benefit the design and operations of droplet-based microfluidics.

8.
Adv Drug Deliv Rev ; 65(11-12): 1470-95, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23726944

RESUMO

The past two decades have seen a dramatic raise in the number of investigations leading to the development of Lab-on-a-Chip (LOC) devices for synthesis of nanomaterials. A majority of these investigations were focused on inorganic nanomaterials comprising of metals, metal oxides, nanocomposites and quantum dots. Herein, we provide an analysis of these findings, especially, considering the more recent developments in this new decade. We made an attempt to bring out the differences between chip-based as well as tubular continuous flow systems. We also cover, for the first time, various opportunities the tools from the field of computational fluid dynamics provide in designing LOC systems for synthesis inorganic nanomaterials. Particularly, we provide unique examples to demonstrate that there is a need for concerted effort to utilize LOC devices not only for synthesis of inorganic nanomaterials but also for carrying out superior in vitro studies thereby, paving the way for faster clinical translation. Even though LOC devices with the possibility to carry out multi-step syntheses have been designed, surprisingly, such systems have not been utilized for carrying out simultaneous synthesis and bio-functionalization of nanomaterials. While traditionally, LOC devices are primarily based on microfluidic systems, in this review article, we make a case for utilizing millifluidic systems for more efficient synthesis, bio-functionalization and in vitro studies of inorganic nanomaterials tailor-made for biomedical applications. Finally, recent advances in the field clearly point out the possibility for pushing the boundaries of current medical practices towards personalized health care with a vision to develop automated LOC-based instrumentation for carrying out simultaneous synthesis, bio-functionalization and in vitro evaluation of inorganic nanomaterials for biomedical applications.


Assuntos
Dispositivos Lab-On-A-Chip , Nanoestruturas , Pontos Quânticos , Animais , Humanos , Hidrodinâmica , Compostos Inorgânicos/química , Metais/química , Microfluídica , Nanocompostos , Pesquisa Translacional Biomédica/métodos
9.
Small ; 8(5): 687-98, 2012 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-22298499

RESUMO

The future of lab-on-a-chip devices for the synthesis of nanomaterials hinges on the successful development of high-throughput methods with better control over their size. While significant effort in this direction mainly focuses on developing "difficult to fabricate" complex microfluidic reactors, scant attention has been paid to the "easy to fabricate" and simple millifluidic systems that could provide the required control as well as high throughput. By utilizing numerical simulation of fluids within the millifluidic space at different flow rates, the results presented here show velocity profiles and residence time distributions similar to the case of microfluidics. By significantly reducing the residence time and residence time distribution, a continuous flow synthesis of ultrasmall copper nanoclusters (UCNCs) with exceptional colloidal stability is achieved. In-situ synchrotron-radiation-based X-ray absorption spectroscopy (XAS) reveal that the as-prepared clusters are about 1 nm, which is further supported by transmission electron microscopy and UV-vis spectroscopy studies. The clusters reported here are the smallest ever produced using a lab-on-a-chip platform. When supported on silica, they are found to efficiently catalyze C-H oxidation reactions, hitherto unknown to be catalyzed by Cu. This work suggests that a millifluidic platform can be an inexpensive, versatile, easy-to-use, and powerful tool for nanoparticle synthesis in general, and more specifically for ultrasmall nanoclusters (UNCs).

10.
Chemphyschem ; 13(1): 177-82, 2012 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-22147552

RESUMO

The size evolution of gold nanoparticles in a millifluidic reactor is investigated using spatially resolved transmission electron microscopy (TEM). The experimental data is supported by numerical simulations, carried out to study the residence-time distribution (RTD) of tracers that have the same properties as Au ions. Size and size distribution of the particles within the channels are influenced by the mixing zones as well as the RTD. However, the Au nanoparticles obtained show a broader size distribution even at the shortest investigated residence time of 3.53 s, indicating that in addition to surface growth reaction kinetics also plays an important role. The comparison of time resolved particle growth within the millifluidic channel with flask-based reactions reveals that the particle size can be controlled better within millifluidic channels. Overall, the results indicate potential opportunities to utilize easy to fabricate millifluidic reactors for the synthesis of nanoparticles, as well as as for carrying out time resolved kinetic studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA