Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
JTCVS Tech ; 23: 21, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38351997
2.
Eur Heart J Case Rep ; 8(1): ytae001, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38249117

RESUMO

Background: Pump thrombosis is a serious complication of continuous-flow left ventricular assist device (CF-LVAD) therapy. In this study, we aim to report a novel protocol of an intermittent, low-dose, and slow infusion of tissue plasminogen activator (alteplase). Case summary: We treated seven LVAD pump thrombosis events (HeartMate® II and HeartWare) in four patients with a median age of 52 years (31-63), and all were female. The protocol was applied from January 2015 to December 2018, and it consisted of an intermittent, low-dose, and slow infusion of systemic thrombolytic therapy in the intensive care unit. This therapy resulted in successful resolution of pump thrombosis in six out of seven events. Bleeding complication occurred in one patient, which included a ruptured haemorrhagic ovarian cyst and a small cerebellar intra-parenchymal haemorrhage. All patients were discharged home in a stable condition, except one patient who died during hospitalization because of severe sepsis, pump thrombosis with subsequent pump exchange, and multi-organ failure. Discussion: A low-dose, prolonged, and systemic thrombolytic infusion protocol is an effective and relatively safe treatment that can lead to a sustained resolution of pump thrombosis with low bleeding complications and failure rates.

3.
Obstet Gynecol ; 142(5): 1029-1035, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37708513

RESUMO

Cardiovascular disease is one of the leading causes of maternal mortality in the United States. Although still rare, pregnancy in patients with left ventricular assist devices (LVADs) is becoming more common. Typical indications for the use of LVADs in reproductive-aged females include ischemic cardiomyopathy, nonischemic (familial) dilated cardiomyopathy, peripartum cardiomyopathy, and some forms of myocarditis. An LVAD drains blood through a cannula placed into the apex of the left ventricle and then returns it to the proximal aorta bypassing the aortic valve allowing hemodynamic support in parallel with the native circulation. The physiologic changes associated with pregnancy, mainly increased blood volume and hypercoagulability, may adversely affect patients with LVADs, leading to many experts recommending against pregnancy. Maternal-fetal medicine specialists should have a central role within a multidisciplinary team required to provide optimal care for this high-risk group of patients.


Assuntos
Cardiomiopatias , Doenças Cardiovasculares , Insuficiência Cardíaca , Coração Auxiliar , Feminino , Gravidez , Humanos , Adulto , Coração Auxiliar/efeitos adversos , Hemodinâmica , Insuficiência Cardíaca/terapia
4.
Cureus ; 15(8): e44281, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37645663

RESUMO

Objective  YouTube (YouTube LLC, San Bruno, California, United States), one of the most accessed sites on the internet, has become a widespread source of healthcare information for patients. Videos about coronary artery bypass grafts (CABG) have accrued tens of millions of views on the platform, yet their educational quality is unknown. This study investigates the educational landscape of videos regarding CABG procedures on YouTube. Methods YouTube was queried for "Coronary Artery Bypass Graft Surgery" and "Coronary Artery Bypass Graft Procedure". After applying exclusion criteria, 73 videos were assessed. Two independent reviewers rated the material with the Global Quality Scale (GQS) (5 = high quality, 0 = low quality) to judge educational value. A ratio of view count to days since upload was applied to assess video popularity. Source, modality, and date of upload were recorded for each video as well. Results An average GQS score of 2.94 was found, indicating poor educational quality of the 73 YouTube videos on CABG procedures. Videos uploaded by physicians (56/73; 76.7%) had a significantly higher average GQS score than those uploaded by non-physicians (p<0.001). When content was grouped by delivery method, physician-led presentations (24/73 or 32.9%) produced the highest average GQS score of 3.35; conversely, patient-friendly delivery methods (18/73 or 24.7%) yielded the lowest average GQS score of 2.36 (p<0.001). Neither the view ratio nor the days since upload significantly correlated with the educational quality of the video. Conclusion Although CABG videos are readily available on YouTube, they often contain considerable biases and misleading information. With online sources for healthcare education now commonplace, physicians must be aware of the vast quantities of low-quality videos patients often encounter when weighing different treatment options. Further analysis of CABG videos on YouTube may allow physicians to ameliorate this gap by producing videos that are not only high quality but highly viewed on the platform.

5.
J Surg Case Rep ; 2023(1): rjad008, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36685116

RESUMO

Solitary fibrous tumor (SFT) are rare pleura neoplasms often localized to middle or inferior hemithorax. A middle-aged woman presents to the emergency department following a motor vehicle accident, the computed tomography scan revealed a giant tumor occupying the entire left pleural cavity with a complete collapse of the left lung and substantial right deviation of heart and mediastinum. Using preoperative arterial coiling followed by a double-level thoracotomy we successfully resected the giant tumor. The SFT weighed ~10 lbs. At 2-month follow-up visit patient reports mild discomfort during strenuous movement/heavy lifting but denies any shortness of breath.

6.
ASAIO J ; 68(11): 1399-1406, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36326705

RESUMO

Our study assessed the relationship between the duration of venovenous extracorporeal membrane oxygenation (V-V ECMO) and patient outcomes. We studied patients undergoing V-V ECMO support for acute respiratory distress syndrome (ARDS) between 2009 and 2017 who were reported to the Extracorporeal Life Support Organization registry. We evaluated survival, major bleeding, renal failure, pulmonary complications, mechanical complications, neurologic complications, infection, and duration of V-V ECMO support. Multivariable regression modeling assessed risk factors for adverse events. Of the 4,636 patients studied, the mean support duration was 12.2 ± 13.7 days. There was a progressive increase in survival after the initiation of V-VECMO, peaking at a survival rate of 73% at 10 days of support. However, a single-day increase in V-V ECMO duration was associated with increased bleeding events (odds ratio [OR] 1.038; 95% confidence interval [CI]: 1.029-1.047; p < 0.0001), renal failure (OR 1.018; 95% CI: 1.010-1.027; p < 0.0001), mechanical complications (OR 1.065; 95% CI: 1.053-1.076; p < 0.0001), pulmonary complications (OR 1.04; 95% CI: 1.03-1.05; p < 0.0001), and infection (OR 1.04; 95% CI: 1.03-1.05; p < 0.0001). V-V ECMO progressively increases survival for ARDS over the first 10 days of support. Thereafter, rising complications associated with prolonged durations of support result in a progressive decline in survival.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Renal , Síndrome do Desconforto Respiratório , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Síndrome do Desconforto Respiratório/terapia , Razão de Chances , Taxa de Sobrevida , Insuficiência Renal/etiologia , Estudos Retrospectivos
7.
Stem Cell Reports ; 16(10): 2459-2472, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34525378

RESUMO

The pathogenicity of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has been attributed to its ability to enter through the membrane-bound angiotensin-converting enzyme 2 (ACE2) receptor. Therefore, it has been heavily speculated that angiotensin-converting enzyme inhibitor (ACEI) or angiotensin receptor blocker (ARB) therapy may modulate SARS-CoV-2 infection. In this study, exposure of human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) and human endothelial cells (hECs) to SARS-CoV-2 identified significant differences in protein coding genes involved in immunity, viral response, and cardiomyocyte/endothelial structure. Specifically, transcriptome changes were identified in the tumor necrosis factor (TNF), interferon α/ß, and mitogen-activated protein kinase (MAPK) (hPSC-CMs) as well as nuclear factor kappa-B (NF-κB) (hECs) signaling pathways. However, pre-treatment of hPSC-CMs or hECs with two widely prescribed antihypertensive medications, losartan and lisinopril, did not affect the susceptibility of either cell type to SARS-CoV-2 infection. These findings demonstrate the toxic effects of SARS-CoV-2 in hPSC-CMs/hECs and, taken together with newly emerging multicenter trials, suggest that antihypertensive drug treatment alone does not alter SARS-CoV-2 infection.


Assuntos
Anti-Hipertensivos/farmacologia , Tratamento Farmacológico da COVID-19 , Células Endoteliais/efeitos dos fármacos , Miócitos Cardíacos/efeitos dos fármacos , COVID-19/genética , Células Cultivadas , Suscetibilidade a Doenças , Células Endoteliais/metabolismo , Interações Hospedeiro-Patógeno/efeitos dos fármacos , Humanos , Lisinopril/farmacologia , Losartan/farmacologia , Miócitos Cardíacos/metabolismo , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/fisiologia , Transcriptoma/efeitos dos fármacos
8.
Semin Thorac Cardiovasc Surg ; 33(2): 382-392, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32977011

RESUMO

This study compares the morbidity and mortality at 30 days following the use of bilateral internal mammary arteries (BIMA) vs a single internal mammary artery (SIMA) at the time of coronary artery bypass grafting (CABG) in patients with a preoperative HbA1c. Patients undergoing CABG from January 2008 to December 2016 reported to the Society of Thoracic Surgeons database were retrospectively reviewed. The patients were divided into 2 groups: use of BIMA or use of SIMA and propensity matched. To assess the effect of preoperative HbA1c, both groups were further divided into 5 subgroups: patients without diabetes mellitus (DM), or patients with DM and a preoperative HbA1c level in one of four groups (< 7%, 7-9%, 9-11%, or >11%). The postoperative outcomes in both the BIMA and SIMA groups were compared. There were 700,504 and 28,115 patients with measured preoperative HbA1c levels in the SIMA and BIMA groups, respectively. Propensity score matching identified 23,635 comparable patients in each group for analysis. There was no difference in postoperative mortality between the BIMA and SIMA groups (1.3% vs 1.2%). The incidences of sternal wound infection (SWI) in patients undergoing placement of BIMA vs SIMA were: 0.8% vs 0.4% with no DM (P < 0.0001), 1.9% vs 1.0% with HbA1c < 7% (P < 0.001), 2.4% vs 1.2% with HbA1c 7-9% (P < 0.001), 2.8% vs 1.4% with HbA1c 9-11% (P = 0.02), 4.1% vs 1.5% with HbA1c > 11% (P = 0.01). Based on the incidence of SWI, BIMA is a reasonable approach with an HbA1c<7%.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Artéria Torácica Interna , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Anastomose de Artéria Torácica Interna-Coronária/efeitos adversos , Artéria Torácica Interna/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
10.
ASAIO J ; 65(1): 54-58, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29324514

RESUMO

Maintaining mechanical circulatory support (MCS) device patients in a specified therapeutic range for anticoagulation remains challenging. Subtherapeutic international normalized ratios (INRs) occur frequently while on warfarin therapy. An effective anticoagulant bridge strategy may improve the care of these patients. This retrospective review of MCS patients with subtherapeutic INRs compared an intravenous unfractionated heparin (UFH) strategy with a subcutaneous enoxaparin or fondaparinux strategy. Native thromboelastography (n-TEG) was used to evaluate anticoagulant effect with coagulation index (CI) as the primary outcome measure. Enoxaparin 0.5 mg/kg subcutaneously (SC) every 12 hours or fondaparinux 2.5-5 mg SC daily were compared with an initial UFH rate of 5 units/kg/hr and titrated to stated n-TEG goal range. The anticoagulant groups UFH, enoxaparin, and fondaparinux were found to be statistically similar with regard to frequency in n-TEG goal range, above range (hypercoagulability), or below range (hypocoagulability). Clinical outcomes were similar among groups with three gastrointestinal bleeds in UFH, one in enoxaparin, and one in fondaparinux groups. Device thrombosis occurred in one UFH patient, while UFH and fondaparinux groups had one ischemic cerebrovascular accident event each. These strategies provided comparable n-TEG results and clinical outcomes when compared with intravenous UFH. Low-dose enoxaparin or fondaparinux may provide an alternative anticoagulant bridging option in MCS patients presenting with subtherapeutic INR.


Assuntos
Anticoagulantes/uso terapêutico , Coração Auxiliar/efeitos adversos , Trombose/prevenção & controle , Enoxaparina/uso terapêutico , Feminino , Fondaparinux/uso terapêutico , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/etiologia
11.
Ann Thorac Surg ; 106(1): e25-e26, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29496435

RESUMO

We report a case of coronary sinus (CS) injury with a retrograde cardioplegia catheter and repair that compromised CS patency. This resulted in acute global cardiac dysfunction shortly after weaning from bypass, which reversed after patch repair with confirmed CS patency. The case report shows that acute CS occlusion may not be tolerated in some humans.


Assuntos
Cânula/efeitos adversos , Seio Coronário/lesões , Parada Cardíaca Induzida/efeitos adversos , Complicações Intraoperatórias/cirurgia , Ruptura/cirurgia , Grau de Desobstrução Vascular , Disfunção Ventricular Esquerda/cirurgia , Idoso , Ponte de Artéria Coronária , Seio Coronário/cirurgia , Parada Cardíaca Induzida/instrumentação , Humanos , Anastomose de Artéria Torácica Interna-Coronária , Balão Intra-Aórtico , Complicações Intraoperatórias/etiologia , Masculino , Ruptura/etiologia , Técnicas de Sutura , Disfunção Ventricular Esquerda/etiologia
13.
J Heart Valve Dis ; 26(3): 355-357, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-29092123

RESUMO

Mitral valve repair is a feasible and preferable option for the treatment of Barlow's disease. Complex valve repair techniques, in contrast, often lead to increased cross-clamp times and low cardiac output syndrome. A simple, fast, and reproducible foldoplasty technique to reduce anterior and posterior mitral leaflet heights may improve coaptation and reduce mitral regurgitation. Accordingly, herein are described minimally invasive, successful trans-septal and robotic approaches for a bileaflet foldoplasty technique in two patients with Barlow's disease.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Prolapso da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Robóticos , Técnicas de Sutura , Toracotomia , Adulto , Ecocardiografia Doppler em Cores , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Valva Mitral/anormalidades , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/instrumentação , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Resultado do Tratamento
14.
Ann Thorac Surg ; 104(3): e239-e241, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28838516

RESUMO

CorMatrix is an organic extracellular matrix (ECM) derived from porcine small intestine submucosa and is used for pericardial closure and cardiac tissue repair. During explantation of a HeartMate II (Thoratec Corp, Pleasanton, CA) left ventricular assist device (LVAD) because of infection, CorMatrix was used to repair the left ventricular apex and aorta. Three months later, a HeartWare HVAD (HeartWare International, Inc, Framingham, MA) was implanted for recurrent heart failure. Excised apical CorMatrix samples showed cardiac tissue remodeling with viable cardiomyoblasts similar to native myocardium. Excised CorMatrix from the aorta showed organization of collagen and elastin similar to native aortic tissue.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Insuficiência Cardíaca/terapia , Coração Auxiliar , Doenças da Aorta/complicações , Doenças da Aorta/patologia , Desfibriladores Implantáveis , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/patologia , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade
15.
Ann Thorac Surg ; 104(4): 1298-1304, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28577850

RESUMO

BACKGROUND: Cardiomyocytes rely heavily on mitochondrial energy production through oxidative phosphorylation. Chronic myocardial ischemia may cause mitochondrial dysfunction and affect ATP formation. Metabolic changes due to ischemia alters cardiac bioenergetics and hence myocardial function and overall bioenergetic state. Here, we evaluate differences in functional status of respiratory complexes in mitochondrial isolates extracted from left atrial appendage tissue (LAA) from patients undergoing cardiac surgery, with and without chronic ischemia. METHODS: Mitochondrial isolates were extracted from LAA in ischemic coronary artery bypass grafting patients (n = 8) and non-ischemic control patients (n = 6) undergoing other cardiac surgery (valve repair/replacement). Coupling and electron transport chain assays were performed using Seahorse XFe 96 (Agilent Technologies, Santa Clara, CA) analyzer. Oxygen consumption rates were measured to calculate respiration states. RESULTS: Respiratory control rate (RCR) in ischemic patients was significantly lower than control patients (6.17 ± 0.27 vs 7.11 ± 0.31, respectively; p < 0.05). This is the result of minimal, non-significant state 3ADP and state 4O changes in chronic ischemia. Complex I respiration is diminished in ischemic tissue (99.1 ± 14.9 vs 257.8 ± 65.2 in control; p < 0.01). Maximal complex I/II respiration ratio was significantly lower in ischemic patients (58.9% ± 5.5% vs 90.9% ± 8.8%; p < 0.05), a difference that was also seen in complex I/IV ratios (p < 0.05). There was no significant difference in complex II/IV ratios between groups. CONCLUSIONS: Ischemic patients have aberrant mitochondrial function, highlighted by a lowered RCR. All ratios involving complex I were affected, suggesting that the insufficient ATP formation is predominantly due to complex I dysfunction. Complex II and IV respiration may be impaired as well, but to a lesser extent.


Assuntos
Mitocôndrias Cardíacas/metabolismo , Isquemia Miocárdica/metabolismo , Miócitos Cardíacos/metabolismo , Consumo de Oxigênio , Apêndice Atrial/citologia , Regulação para Baixo , Transporte de Elétrons , Humanos
17.
Int J Legal Med ; 131(2): 485-487, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27771771

RESUMO

We present a case of a patient undergoing aortic valve replacement being inadvertently administered 5000 U of bovine thrombin instead of heparin for anticoagulation for cardiopulmonary bypass. The labeling error was made within the operating room pharmacy. The key to survival of this patient was a rapid diagnosis, administration of antithrombin and heparin, and removal of cardiac and great vessel thrombi. It is recommended that point of care anesthesia providers `prepare heparin for cardiopulmonary bypass anticoagulation, as thrombin is not used in anesthetic practice and is not contained within anesthesia cabinet medication drawers.


Assuntos
Hemostáticos/efeitos adversos , Erros de Medicação , Pré-Medicação , Trombina/efeitos adversos , Idoso , Ponte Cardiopulmonar , Feminino , Hemostáticos/administração & dosagem , Humanos , Trombina/administração & dosagem
18.
J Cardiothorac Surg ; 11(1): 161, 2016 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-27899134

RESUMO

BACKGROUND: Aortic valve insufficiency (AI) at the time of left ventricular assist device (LVAD) insertion needs to be corrected, however there is little known about how to manage bioprosthetic valvular AI. CASE PRESENTATION: A 55-year-old female with dilated cardiomyopathy who previously had a bioprosthetic aortic valve replacement needed a LVAD as a bridge to transplant. Her left ventricular ejection fraction was 10% and had mild to moderate transvalvular AI. She underwent a HeartWare HVAD insertion along with aortic valvular coaptation stitch repair (Park's stitch) to the bioprosthetic valve. CONCLUSION: Her AI improved to trivial with minimal ejection through the bioprosthetic valve. She was transplanted 6 months following the surgery. A Park's stitch to the bioprosthetic aortic valve with more than mild AI might be a good option for bridge to transplant patient.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Coração Auxiliar , Técnicas de Sutura , Insuficiência da Valva Aórtica/etiologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Implantação de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA