Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(11): 1967-1977, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37011038

RESUMO

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 µg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS: We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.


Assuntos
Isótopos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Levetiracetam , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Padrões de Referência
2.
Clin Chem Lab Med ; 61(11): 1917-1929, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36788118

RESUMO

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. RESULTS: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 µmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. CONCLUSIONS: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.


Assuntos
Metotrexato , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Isótopos , Padrões de Referência , Reprodutibilidade dos Testes
3.
Clin Chem Lab Med ; 61(11): 1955-1966, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36689915

RESUMO

OBJECTIVES: To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS: A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS: The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS: This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Gabapentina , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Isótopos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA