Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Proteomics ; : e2400223, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39233542

RESUMO

Adeno-associated viruses (AAVs) are common vectors for emerging gene therapies due to their lack of pathogenicity in humans. Here, we present our investigation of the viral proteins (i.e., VP1, VP2, and VP3) of the capsid of AAVs via top-down mass spectrometry (MS). These proteins, ranging from 59 to 81 kDa, were chromatographically separated using hydrophilic interaction liquid chromatography and characterized in the gas-phase by high-resolution Orbitrap Fourier transform MS. Complementary ion dissociation methods were utilized to improve the overall sequence coverage. By reducing the overlap of product ion signals via proton transfer charge reduction on the Orbitrap Ascend BioPharma Tribrid mass spectrometer, the sequence coverage of each VP was significantly increased, reaching up to ∼40% in the case of VP3. These results showcase the improvements in the sequencing of proteins >30 kDa that can be achieved by manipulating product ions via gas-phase reactions to obtain easy-to-interpret fragmentation mass spectra.

2.
Anal Bioanal Chem ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39283368

RESUMO

Modern mass spectrometry technology allows for extensive sequencing of the ~ 25 kDa subunits of monoclonal antibodies (mAbs) produced by IdeS proteolysis followed by disulfide bond reduction, an approach known as middle-down mass spectrometry (MD MS). However, the spectral congestion of tandem mass spectra of large polypeptides dramatically complicates fragment ion assignment. Here, we report the development and benchmark of an MD MS strategy based on the combination of different ion fragmentation techniques with proton transfer charge reduction (PTCR) to simplify the gas-phase sequencing of mAb subunits. Applied on the liquid chromatography time scale using an Orbitrap Tribrid mass spectrometer, PTCR produces easy-to-interpret mass spectra with limited ion signal overlap. We demonstrate that the accurate estimation of the number of charges submitted to the Orbitrap mass analyzer after PTCR allows for the detection of charge-reduced product ions over a wide mass-over-charge (m/z) window with low parts per million m/z accuracy. Therefore, PTCR-based MD MS analysis increases not only sequence coverage, number of uniquely identified fragments, and number of assigned complementary ion pairs, but also the general confidence in the assignment of subunit fragments. This data acquisition method can be readily applied to any class of mAbs without an apparent need for optimization, and benefits from the high resolving power of the Orbitrap mass analyzer to return sequence coverage of individual subunits exceeding 80% in a single run, and > 90% when just two experiments are combined.

3.
J Am Soc Mass Spectrom ; 35(9): 2197-2208, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39105725

RESUMO

Established in recent years as an important approach to unraveling the heterogeneity of intact monoclonal antibodies, native mass spectrometry has been rarely utilized for sequencing these complex biomolecules via tandem mass spectrometry. Typically, top-down mass spectrometry has been performed starting from highly charged precursor ions obtained via electrospray ionization under denaturing conditions (i.e., in the presence of organic solvents and acidic pH). Here we systematically benchmark four distinct ion dissociation methods─namely, higher-energy collisional dissociation, electron transfer dissociation, electron transfer dissociation/higher-energy collisional dissociation, and 213 nm ultraviolet photodissociation─in their capability to characterize a therapeutic monoclonal antibody, trastuzumab, starting from denatured and native-like precursor ions. Interestingly, native top-down mass spectrometry results in higher sequence coverage than the experiments carried out under denaturing conditions, with the exception of ultraviolet photodissociation. Globally, electron transfer dissociation followed by collision-based activation of product ions generates the largest number of backbone cleavages in disulfide protected regions, including the complementarity determining regions, regardless of electrospray ionization conditions. Overall, these findings suggest that native mass spectrometry can certainly be used for the gas-phase sequencing of whole monoclonal antibodies, although the dissociation of denatured precursor ions still returns a few backbone cleavages not identified in native experiments. Finally, a comparison of the fragmentation maps obtained under denaturing and native conditions strongly points toward disulfide bonds as the primary reason behind the largely overlapping dissociation patterns.


Assuntos
Anticorpos Monoclonais , Desnaturação Proteica , Trastuzumab , Trastuzumab/química , Trastuzumab/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA