Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Mass Spectrom ; 49(1): 80-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24446266

RESUMO

Isocoproporphyrin and its derivatives are commonly used as biomarkers of porphyria cutanea tarda, heavy metal toxicity and hexachlorobenzene (HCB) intoxication in humans and animals. However, most are isobaric with other porphyrins and reference materials are unavailable commercially. The structural characterisation of these porphyrins is important but very little data is available. We report here the separation and characterisation of isocoproporphyrin, deethylisocoproporphyrin, hydroxyisocoproporphyrin and ketoisocoproporphyrin, isolated in the faeces of rats fed with a diet containing HCB, by ultra high performance liquid chromatography-exact mass tandem mass spectrometry (UHPLC-MS/MS). Furthermore, we report the identification and characterisation of a previously unreported porphyrin metabolite, isocoproporphyrin sulfonic acid isolated in the rat faeces. The measured mass-to-charge ratio (m/z) of the precursor ion was m/z 735.2338, corresponding to a molecular formula of C36H39N4O11S with an error of 0.3 ppm from the calculated m/z 735.2336. The MS/MS data was consistent with an isocoproporphyrin sulfonic acid structure, derived from dehydroisocoproporphyrinogen by sulfonation of the vinyl group. The metabolite was present in a greater abundance than other isocoproporphyrin derivatives and may be a more useful biomarker for HCB intoxication.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Coproporfirinas/análise , Ácidos Sulfônicos/análise , Espectrometria de Massas em Tandem/métodos , Animais , Coproporfirinas/química , Coproporfirinas/metabolismo , Fezes/química , Feminino , Hexaclorobenzeno , Ratos , Ratos Sprague-Dawley , Espectrometria de Massas por Ionização por Electrospray/métodos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/metabolismo
2.
Biomed Chromatogr ; 27(12): 1782-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23893773

RESUMO

Biological and clinical samples for porphyrin and porphyrinogen analyses by liquid chromatography-tandem mass spectrometry (LC-MS/MS) are often contaminated with poly(ethylene)glycol (PEG), which complicates the interpretation of mass spectra and characterisation of new porphyrin metabolites. Two contaminating PEG molecules (m/z 833 and m/z 835) were completely separated from uroporphyrin I (m/z 831) by travelling wave ion mobility spectrometry and characterised by tandem mass spectrometry. One of the PEG species (m/z 835) also co-eluted with uroporphyrinogen I (m/z 837) and was unresolvable by travelling wave ion mobility spectrometry/MS, therefore contaminating the MS/MS mass spectra owing to isotope distribution. These PEG species, with the [M + H](+) ions at m/z at 833 and/or m/z 835, co-eluted with uroporphyrin I and uroporphyrinogen I by LC-MS/MS and could be wrongly identified as uroporphomethenes.


Assuntos
Cromatografia Líquida/métodos , Polietilenoglicóis/química , Porfirinogênios/química , Porfirinas/química , Espectrometria de Massas em Tandem/métodos , Animais , Fígado/química , Porfirinogênios/análise , Porfirinogênios/isolamento & purificação , Porfirinas/análise , Porfirinas/isolamento & purificação , Ratos
3.
Biomed Chromatogr ; 27(2): 267-72, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23180457

RESUMO

Serum/plasma concentrations of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG) are elevated in patients with acute hepatic porphyrias, especially during acute attacks. Current assays require lengthy sample pre-treatment and derivatization steps. We report here a rapid, sensitive and specific hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the direct and simultaneous quantitation of ALA and PBG in serum or plasma following simple protein precipitation with acetonitrile and centrifugation prior to injection. ALA and PBG were detected using selected reaction monitoring mode, following positive atmospheric pressure chemical ionization. Calibration was linear from 0.05 to 50 µmol/L for ALA and PBG. For both analytes, imprecision (relative standard deviation) was <13% and accuracy (percentage nominal concentrations) was between 92 and 107%. The method was successfully applied to the measurement of ALA and PBG in serum or plasma samples for the screening, biochemical diagnosis and treatment monitoring of patients with acute hepatic porphyrias.


Assuntos
Ácido Aminolevulínico/sangue , Cromatografia Líquida/métodos , Porfobilinogênio/sangue , Espectrometria de Massas em Tandem/métodos , Ácido Aminolevulínico/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Análise dos Mínimos Quadrados , Porfobilinogênio/química , Porfiria Aguda Intermitente/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Biomed Chromatogr ; 26(8): 1009-23, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22806492

RESUMO

This article discusses the separation, analysis and characterisation of intermediates and oxidative by-products of the haem biosynthetic pathway by liquid chromatography and mass spectrometry. Techniques reviewed include high-performance liquid chromatography, ultra-high-performance liquid chromatography, capillary electrophoresis, ion mobility spectrometry, mass spectrometry and tandem mass spectrometry. The emphasis was on the analysis of biological and clinical samples.


Assuntos
Cromatografia Líquida/métodos , Heme/análise , Espectrometria de Massas/métodos , Porfirias , Animais , Heme/química , Heme/urina , Humanos
5.
Biomed Chromatogr ; 26(8): 1033-40, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22740490

RESUMO

Urinary concentrations of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG) are elevated in patients with acute hepatic porphyrias, especially during acute attacks. Current assays require lengthy sample pre-treatment and derivatisation steps. We report here a rapid, sensitive and specific hydrophilic interaction liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, for the direct and simultaneous quantitation of ALA and PBG in urine following simple dilution with acetonitrile and centrifugation prior to injection. ALA and PBG were detected using selected reaction monitoring mode, following positive electrospray ionisation. Urine samples (N = 46) from active and latent mutation-confirmed acute hepatic porphyria patients and normal subjects (N = 45) were analysed and the results compared with those of a commercially available spectrophotometric method. The validated calibration range was 3-3000 µmol/L for ALA and 2-2000 µmol/L for PBG. For both analytes, imprecision (relative standard deviation) was less than 5% and accuracy (percentage nominal concentrations) was between 88 and 109%. The lower limit of quantitation was 0.1 µmol/L for both analytes. The calculated LC-MS/MS and spectrophotometric results from patient samples compared well [Pearson correlation (r²) of 0.99 and 0.95, for ALA and PBG, respectively]. The method was successfully applied to the measurement of ALA and PBG in urine samples for the screening, biochemical diagnosis and treatment monitoring of patients with acute hepatic porphyrias.


Assuntos
Ácido Aminolevulínico/urina , Cromatografia Líquida/métodos , Porfobilinogênio/urina , Espectrometria de Massas em Tandem/métodos , Análise de Variância , Humanos , Interações Hidrofóbicas e Hidrofílicas , Modelos Lineares , Porfiria Aguda Intermitente/urina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
6.
J Inorg Biochem ; 112: 77-84, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22561545

RESUMO

There are extensive structural similarities between eukaryotic and prokaryotic ferritins. However, there is one essential difference between these two types of ferritins: bacterioferritins contain haem whereas eukaryotic ferritins are considered to be non-haem proteins. In vitro experiments had shown that horse spleen apoferritin or recombinant horse L chain apoferritins, when co-crystallised with haemin, undergoes demetallation of the porphyrin. In the present study a cofactor has been isolated directly from horse spleen apoferritin and from crystals of the mutant horse L chain apoferritin (E53Q, E56Q, E57Q, E60Q and R59M) which had been co-crystallised with haemin. In both cases the HPLC/ESI-MS results confirm that the cofactor is a N-ethylprotoporphyrin IX. Crystal structures of wild type L chain horse apoferritin and its three mutants co-crystallised with haemin have been determined to high resolution and in all cases a metal-free molecule derived from haemin was found in the hydrophobic pocket, close to the two-fold axis. The X-ray structure of the E53Q, E56Q, E57Q, E60Q+R59M recombinant horse L-chain apoferritin has been obtained at a higher resolution (1.16Å) than previously reported for any mammalian apoferritins. Similar evidence for a metal-free molecule derived from haemin was found in the electron density map of horse spleen apoferritin (at a resolution of 1.5Å). The out-of-plane distortion of the observed porphyrin is clearly compatible with an N-alkyl porphyrin. We conclude that L-chain ferritins are capable of binding and demetallating haemin, generating in the process N-ethylprotoporphyrin IX both in vivo and in vitro.


Assuntos
Apoferritinas/química , Hemina/química , Protoporfirinas/química , Animais , Apoferritinas/genética , Sítios de Ligação , Cromatografia Líquida de Alta Pressão , Cristalização , Cristalografia por Raios X , Cavalos , Metais/química , Modelos Moleculares , Mutação , Ligação Proteica , Conformação Proteica , Protoporfirinas/isolamento & purificação , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Espectrometria de Massas por Ionização por Electrospray , Baço/química , Baço/metabolismo
7.
Rapid Commun Mass Spectrom ; 26(4): 480-6, 2012 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-22279024

RESUMO

RATIONALE: Human porphyrias, diseases caused by enzyme defects in haem biosynthesis, are characterised by the excessive production, accumulation and excretion of porphyrins and/or 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG). A method for the simultaneous separation, detection and identification of ALA, PBG and porphyrins would greatly facilitate the screening and diagnosis of porphyrias. Such a method would also be invaluable for the biochemical study of the haem, chlorophyll and corrin pathways. METHODS: An aqueous mixture containing ALA, PBG and type I isomer porphyrins was diluted with acetonitrile and infused (10 µL/min) into a Waters Synapt G2 high-definition mass spectrometer, equipped with a Z-Spray electrospray ionisation (ESI) source. Mass spectra were acquired in positive ionisation mode and the optimised ion mobility spectrometry (IMS) conditions were as follows: IMS wave height (V), 40; IMS wave velocity (m/s), 648; IMS gas flow (mL/min) 90.40; helium gas flow (mL/min), 182.60. RESULTS: The IMS drift-time increased with increasing ion mass in the order of ALA, PBG, mesoporphyrin, coproporphyrin I, penta-, hexa- and heptacarboxylic acid porphyrin I and uroporphyrin I. The ESI-IMS-MS spectra shows that PBG could form two different positively charged ions by protonation [M+H](+) , m/z 227, or deprotonation [M - H](+) , m/z 225. The protonated PBG (m/z 227) easily eliminated ammonia in source and the fragment ion (m/z 210) was monitored instead. Doubly charged ions of porphyrins having different drift times from the protonated singly charged molecules were observed in high abundance, providing further structural characterisation. CONCLUSIONS: We have shown, for the first time, an analytical method capable of simultaneously separating haem biosynthetic intermediates and metabolites, for a potential rapid clinical screening method for the porphyrias. IMS-MS allowed the separation of doubly charged porphyrin ions, which will be advantageous for the analysis of natural and synthetic tetrapyrrole compounds, while reducing the misinterpretation of contaminants.


Assuntos
Ácido Aminolevulínico/análise , Porfobilinogênio/análise , Porfirinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Ácido Aminolevulínico/isolamento & purificação , Porfobilinogênio/isolamento & purificação , Porfirinas/isolamento & purificação , Espectrometria de Massas em Tandem
8.
Biomed Chromatogr ; 26(3): 331-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21732398

RESUMO

An ultra high-performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta-, hexa-, penta-carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow-rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Porfirinas/análise , Fezes , Humanos , Porfirias/metabolismo , Porfirias/urina , Extração em Fase Sólida , Espectrometria de Fluorescência
9.
Biomed Chromatogr ; 26(6): 714-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22031323

RESUMO

Ultra high-performance liquid chromatographic (UHPLC) systems on columns packed with materials ranging from 1.9 to 2.7 µm average particle size were assessed for the fast and sensitive analysis of porphyrins in clinical materials. The fastest separation was achieved on an Agilent Poroshell C(18) column (2.7 µm particle size, 50 × 4.6 mm i.d.), followed by a Thermo Hypersil Gold C(18) column (1.9 µm particle size, 50 × 2.1 mm i.d.) and the Thermo Hypersil BDS C(18) column (2.4 µm particle size, 100 × 2.1 mm i.d.). All columns required a mobile phase containing 1 m ammonium acetate buffer, pH 5.16, with a mixture of acetonitrile and methanol as the organic modifiers for optimum resolution of the type I and III isomers, particularly for uroporphyrin I and III isomers. All UHPLC columns were suitable and superior to conventional HPLC columns packed with 5 µm average particle size materials for clinical sample analysis.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Porfirinas/análise , Acetatos/química , Acetonitrilas/química , Fezes/química , Humanos , Metanol/química , Microesferas , Tamanho da Partícula , Porfiria Cutânea Tardia , Porfirinas/química , Porfirinas/urina , Extração em Fase Sólida
10.
Rapid Commun Mass Spectrom ; 25(1): 50-4, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-21157858

RESUMO

'Accurate mass' measurements in electrospray mass spectrometry are becoming more prevalent with the increasing availability of mass spectrometers with sufficient resolution. A reference compound is ideally admitted separately but almost simultaneously with the analyte and this is achieved by use of a 'dual sprayer' or voltage switching between reference and sample sprayers. This paper describes a novel third method, relying on cavitation (segmentation) of the liquid stream containing the reference compound, allowing the sample to ionise independently from the sample, thus preventing interference. The technique may also find application in kinetic experiments, such as protein folding studies. A high-performance liquid chromatography (HPLC) injector was also used to provide a reference compound, producing Gaussian-shaped profiles of varying ion intensity, thus allowing easier selection of a desirable measurement point where the intensities of the reference and analyte were similar.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/métodos , Calibragem , Cromatografia Líquida de Alta Pressão , Encefalina Leucina/química , Desenho de Equipamento , Peso Molecular , Distribuição Normal , Preparações Farmacêuticas/química , Padrões de Referência
11.
Rapid Commun Mass Spectrom ; 25(24): 3749-57, 2011 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-22275316

RESUMO

An ultra-high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry system is described for the separation and characterisation of uroporphyrinogen, heptacarboxylic acid porphyrinogen, hexacarboxylic acid porphyrinogen, pentacarboxylic acid porphyrinogen and coproporphyrinogen. The separation was carried out on a 100 mm × 2.1 mm Thermo-Hypersil BDS column (2.4 µm average particle size) by gradient elution with a mixture of acetonitrile, methanol and 1 mol/L aqueous ammonium acetate buffer, pH 5.16, as eluent. The fragmentation pattern of each compound was established by collision-induced dissociation tandem mass spectrometry. The most characteristic fragmentation was ring opening at one of the four methylene bridges of the protonated porphyrinogen molecule followed by further cleavages of methylene bridges linking the four pyrrole rings at various points to give product ions with methylenepyrrolenine, methylene-dipyrrolenine and methylene-tripyrrolenine structures.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Porfirinogênios/análise , Porfirinogênios/química , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos
12.
Biomed Chromatogr ; 21(7): 661-3, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17516469

RESUMO

An uroporphomethene inhibitor of uroporphyrinogen decarboxylase, characterized by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry, was reported recently (Phillips et al., Proceedings of the National Academy of Sciences of the United States of America 2007; 104: 5079-5084). Close examination of the tandem mass spectrometric fragmentation pattern of the compound showed that it is not a tetrapyrrole or an uroporphyrinogen or uroporphyrin related molecule. The product ion spectrum showed a fragmentation pattern typical of a poly(ethylene glycol) structure. Characteristic fragmentations of the side-chain acetic acid and propionic acid substituents of a uroporphyrin or uroporphyrinogen derivative were absent.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores Enzimáticos/farmacologia , Porfirinogênios/farmacologia , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Uroporfirinogênio Descarboxilase/antagonistas & inibidores
13.
Biomed Chromatogr ; 21(5): 534-45, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17345569

RESUMO

Hydroxylated uroporphyrin I and urochlorin I derivatives formed by photochemical oxidation of uroporphyrinogen I were separated by high-performance liquid chromatography and fully characterized by electrospray ionization tandem mass spectrometry. The porphyrins and chlorins were identified by analysis of their product ion spectra with each hydroxylated derivative giving a characteristic collision-induced dissociation fragmentation pattern. The porphyrins and chlorins characterized were meso-hydroxyuroporphyrin I, alpha-hydroxypropionic acid uroporphyrin I, beta-hydroxypropionic acid uroporphyrin I, hydroxyacetic acid uroporphyrin I, trans-7-hydroxy-8-spirolactoneurochlorin I, cis-7-hydroxy-8-spirolactoneurochlorin I and trans- and cis-7,8-dihydroxyurochlorins I.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Uroporfirinas/análise , Hidroxilação , Oxirredução , Fotoquímica
14.
Chem Res Toxicol ; 19(12): 1660-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17173380

RESUMO

Previous work has shown that 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) causes porphyria, enhanced by iron, in C57BL/6J mice with marked accumulation in the liver of uroporphyrin I and III isomers and heptacarboxylic acid III and is one model of human porphyria cutanea tarda. Preliminary examination by HPLC also indicated the presence of some oxygenated side chain uroporphyrin derivatives. Here, the porphyrin constituents of TCDD-induced porphyric liver have been examined by HPLC/electrospray ionization quadrupole time-of-flight mass spectrometry (HPLC/ESI-Q-TOFMS) to characterize the major and minor porphyrins present in hepatic tissue. As well as the major constituents uroporphyrins I and III, we identified the isomers of heptacarboxylic, hexacarboxylic, and pentacarboxylic acid porphyrins arising from intermediates in the stepwise decarboxylation of uroporphyrinogen I and III to coproporphyrinogens. In addition, monohydroxy analogues of uroporphyrin isomers were detected hydroxylated in the acetic acid and beta-positions of propionic acid side chains and in the meso ring position. Of particular note, for the first time for human and experimental porphyrias, we found chlorins (dihydroxy-, hydroxyspirolactone- ,and dihydroxyspirolactone-urochlorins) consistent with those derived from an epoxyurochlorin structure, formed by oxidation of the double bond of a pyrrole ring of uroporphyrinogen I and III isomers. The findings demonstrate that oxygen insertion into the pyrrole rings of uroporphyrinogens occurs under pathological circumstances in vivo and support the evidence for an oxidative cellular environment present in TCDD-treated porphyric tissue.


Assuntos
Fígado/efeitos dos fármacos , Dibenzodioxinas Policloradas/toxicidade , Espironolactona/metabolismo , Uroporfirinogênios/metabolismo , Uroporfirinas/metabolismo , Animais , Cromatografia Líquida de Alta Pressão , Fígado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Estrutura Molecular , Oxirredução , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem
15.
Biomed Chromatogr ; 20(6-7): 612-21, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16779779

RESUMO

A high-resolution high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry method is described for the analysis of porphyrins in blood, urine and faeces. The gradient elution reversed-phase HPLC system using acetonitrile-methanol-1 m ammonium acetate/acetic acid buffer (pH 5.16) as gradient solvent mixtures was able to separate all porphyrin metabolites, including the type I and type III isomers of uroporphyrin, hepta-, hexa- and penta-carboxylic acid porphyrins and coproporphyrin. The porphyrins were positively identified by the protonated molecules [M+H](+) and further characterized by tandem mass spectrometric analysis with each porphyrin giving a characteristic collisioninduced dissociation product ion spectrum. The mass chromatograms obtained by HPLC/ESI MS are useful for the differential diagnosis of the porphyrias, since each type of porphyria has a typical porphyrin excretion pattern.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fezes/química , Porfirinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Porfirinas/sangue , Porfirinas/urina
16.
Electrophoresis ; 26(4-5): 812-817, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15714566

RESUMO

A capillary electrochromatography (CEC) method has been developed for the separation of caffeine and its two metabolites 1-methylxanthine (1-MX) and 1,7-dimethylxanthine (1,7-DX). The stationary phase was 3-(1,8-naphthalimido) propyl-modified silyl silica gel (NAIP) and the best separations were achieved with 4.0 mM citrate buffer (pH 5.0) containing 80% methanol at an applied voltage of 25 kV. The compounds were completely separated in less than 3.5 min with good repeatability, which was approximately 3-times less than that in high-performance liquid chromatography (HPLC) with NAIP. The proposed method coupled with microdialysis was successfully applied to the monitoring of caffeine concentration in rat brain with detection limits of 1.11 microg/mL.


Assuntos
Química Encefálica , Cafeína/isolamento & purificação , Cafeína/metabolismo , Cromatografia Capilar Eletrocinética Micelar/métodos , Animais , Soluções Tampão , Concentração de Íons de Hidrogênio , Masculino , Metanol , Microdiálise , Compostos Organometálicos , Ratos , Ratos Wistar , Reprodutibilidade dos Testes
17.
Rapid Commun Mass Spectrom ; 18(19): 2309-16, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15384152

RESUMO

Harderoporphyrin (2-vinyl-4,6,7-tripropionic acid porphyrin) and its metabolites in faeces of patients with hereditary coproporphyria (HCP) have been separated and characterized by high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry (HPLC/ESI-Q-TOFMS/MS). The metabolites identified were 2-ethyl-4,6,7-tripropionic acid porphyrin, 2-hydro-4,6,7-tripropionic acid porphyrin, 2-methoxyethyl-4,6,7-tripropionic acid porphyrin and 2-acetyl-4,6,7-tripropionic acid porphyrin. Isomers of harderoporphyrin derived from isomerization of harderoporphyrinogen were also detected.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Coproporfiria Hereditária/diagnóstico , Coproporfiria Hereditária/metabolismo , Fezes/química , Porfirinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Humanos , Porfirinas/classificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Electrophoresis ; 25(4-5): 594-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14981686

RESUMO

A capillary electrochromatographic method was developed for the separation of barbiturates. The separation was optimized in a 75 microm ID capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effect of buffer pH, buffer concentration, and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 40% methanol provided the baseline separation of barbital, phenobarbital, secobarbital, and thiopental (internal standard) in less than 4.5 min. The method was successfully applied to the analysis of barbiturates in human serum. Under the optimal conditions, good repeatability and linearity were obtained in the range of 2.90-43.29 microg/mL for barbital, phenobarbital, and secobarbital.


Assuntos
Barbitúricos/sangue , Cromatografia Capilar Eletrocinética Micelar/métodos , Barbitúricos/isolamento & purificação , Soluções Tampão , Humanos , Concentração de Íons de Hidrogênio , Metanol/química , Reprodutibilidade dos Testes , Dióxido de Silício/química , Tempo
19.
Biomed Chromatogr ; 17(2-3): 143-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12717803

RESUMO

Tamoxifen is administered for the treatment of breast cancer; however resistance to therapy is commonplace. Postulated mechanisms of resistance to tamoxifen include altered pharmacology of the drug, changes in the structure and function of the oestrogen receptor and expression of genes that function to support the growth of cells resistant to tamoxifen. However, binding of drugs to proteins found in the plasma is known to affect the efficacy of drugs and alter their distribution. It is already known that tamoxifen is bound 99% to albumin. We investigated the interaction between the plasma protein, alpha-1-acid glycoprotein (AGP), and tamoxifen, since if binding did occur then the free plasma concentration of the drug would be reduced, resulting in the minimum effective concentration of tamoxifen not being attained. Using a recently described intrinsic fluorescence technique for the study of drug-protein interactions, the extent of binding between tamoxifen citrate and AGP was determined. Furthermore, analysis of binding of the known active metabolites of tamoxifen (4-hydroxytamoxifen, N-desmethyltamoxifen, N-desdimethyltamoxifen, cis-alpha-hydroxytamoxifen and trans-alpha-hydroxytamoxifen) to AGP was conducted. Tamoxifen citrate and metabolites were shown to bind AGP, however the level of interaction was low and negligible at the concentration of the drug found in the plasma.


Assuntos
Orosomucoide/metabolismo , Tamoxifeno/metabolismo , Humanos , Ligação Proteica
20.
Biol Pharm Bull ; 25(5): 547-57, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12033491

RESUMO

The current developments in liquid chromatography-mass spectrometry (LC-MS) and its applications to the analysis of pharmaceuticals are reviewed. Various mass spectrometric techniques, including electrospray and nanospray ionization, atmospheric pressure chemical ionization and photoionization and their interface with liquid chromatographic techniques are described. These include high performance liquid chromatography, capillary electrophoresis and capillary electrochromatography and the advantages and disadvantages of each technique are discussed. The applications of LC-MS to the studies of in vitro and in vivo drug metabolism, identification and characterization of impurities in pharmaceuticals, analysis of chiral impurities in drug substances and high-throughput LC-MS-MS systems for applications in the "accelerated drug discovery" process are described.


Assuntos
Cromatografia Líquida/tendências , Espectrometria de Massas/tendências , Contaminação de Medicamentos , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas de Bombardeamento Rápido de Átomos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA