Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Thorac Dis ; 16(1): 51-64, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38410615

RESUMO

Background: Transthoracic echocardiography (TTE) is recommended as the most important noninvasive screening tool for the diagnosis of pulmonary hypertension (PH), sonographers usually measure the volume of regurgitant flow rather than evaluating the spectral quality, so physicians will determine whether the ultrasound measurements of pulmonary arterial systolic pressure (US-PASP) are reliable based on the volume of tricuspid regurgitation (TR). Therefore, for the first time, we grade the quality of TR spectrum (TRS) based on its integrity and clarity, aiming to assess clinical application value of different tricuspid regurgitant spectrum quality grades (TR-SQG), and investigate whether the accuracy of US-PASP is more trustworthy than TR. Methods: We retrospectively analyzed 108 patients with chronic thromboembolic PH (CTEPH) to compare the correlation and agreement between US-PASP and right heart catheterization measurements of PASP (RHC-PASP). TR area (TRA) and TRS were measured in each patient, and TR-SQG was performed. Results: The correlation coefficients between US-PASP and RHC-PASP were r=0.622 (P<0.001), r=0.754 (P<0.001), r=0.595 (P<0.001) in mild, moderate, severe TR, and r=0.301 (P=0.135), r=0.747 (P<0.001), r=0.739 (P<0.001), r=0.828 (P<0.001) in TR-SQG I-IV, respectively. Bland-Altman analysis revealed the mean biases of 5.05, 3.06, 7.62 mmHg in mild, moderate, severe TR, and -16.47, -8.07, 1.82, 6.09 mmHg in TR-SQG I-IV, respectively. In mild TR with the TR-SQG III and IV, the correlation coefficients between US-PASP and RHC-PASP were r=0.779 (P<0.001), intraclass correlation coefficient (ICC) =0.774, paired t-test P=0.160, respectively; and the consistency was significantly higher than that of mild TR without considering TR-SQG. In moderate TR with the TR-SQG III and IV, the r=0.749, ICC =0.746, paired t-test P=0.298 between US-PASP and RHC-PASP. Conclusions: The US-PASP with TR-SQG III or IV is trustworthy, and its accuracy and consistency are better than those predicted by the traditional severity of TR. The establishment of the ultrasound evaluation system of TR-SQG helps clinicians to judge whether the US-PASP is accurate, credible, and reliable.

2.
IEEE Trans Neural Netw Learn Syst ; 34(8): 4981-4989, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34855601

RESUMO

In many practical applications, it is difficult or impossible to obtain the exact solution of the mathematical model due to the limitations of solving methods and the complexity of the neural network itself. A natural problem is given as follows: does the exact solution of quaternion-valued neural networks (QVNNs) exist when successively improved approximate solutions can be obtained? Fortunately, the Hyers-Ulam stability happens to be one of the important means to deal with this problem. In this article, the issue of Hyers-Ulam stability of QVNNs with time-varying delays is addressed. First, inspired by the Hyers-Ulam stability of general functional equations, the concept of the Hyers-Ulam stability of QVNNs is proposed along with the QVNNs model. Then, by utilizing the successive approximation method, both delay-dependent and delay-independent Hyers-Ulam stability criteria are obtained to ensure the Hyers-Ulam stability of the QVNNs considered. Finally, a simulation example is given to verify the effectiveness of the derived results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA