Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int Orthop ; 48(8): 1997-2005, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38652245

RESUMO

PURPOSE: Periprosthetic femoral fractures (PPFs) around the hip are challenging complications in orthopaedic surgery, particularly Vancouver type B2 (VTB2) fractures. The surgical management of these fractures is crucial and depends on various factors. Cementless short taper stem with plate osteosynthesis is an alternative surgical technique. This study aims to compare the outcomes of this surgical technique with revision arthroplasty (RA) with long stem in the treatment of VTB2 PPFs. METHODS: This retrospective study was conducted in a single medical institute from February 2010 to May 2019. Patients who had received either total hip arthroplasty or bipolar hemiarthroplasty and subsequently developed a VTB2 PPF were included; patients who sustained intra-operative fractures or received a cemented stem previously were excluded from the analysis. The patients were divided into two groups: group I received RA with cementless long stem, while group II underwent RA with cementless short taper stem with plate osteosynthesis. Demographic data, radiographic and functional outcomes, and complications were analyzed between the two groups. RESULTS: A total of 85 patients diagnosed with VTB2 PPFs were included in the study. There were no significant differences between the two groups in terms of demographic data, including age, gender, mean follow-up times, estimated blood loss, and operative times. The radiographic results showed that there was no significant difference in the incidence of subsidence and implant stability between the two groups. However, group II tended to have less subsidence and periprosthetic osteolysis. Patients in group II had significantly better functional scores (mean Harris hip score: post-operative: 60.2 in group I and 66.7 in group ii; last follow-up: 77.4 in group 1 and 83.2 in group II (both p < 0.05)). There were no significant differences in the overall complication rate, including infection, dislocation, re-fracture, and revision surgery, between the two groups. CONCLUSIONS: Both surgical techniques, cementless long stem and cementless short taper stem with plate osteosynthesis, are effective in the treatment of Vancouver B2 PPFs, with no significant differences in outcomes or complications. However, patients in cementless short taper stem with plate osteosynthesis had better functional scores at both post-operative and the last follow-up.


Assuntos
Artroplastia de Quadril , Placas Ósseas , Fraturas do Fêmur , Fixação Interna de Fraturas , Prótese de Quadril , Fraturas Periprotéticas , Reoperação , Humanos , Feminino , Fraturas Periprotéticas/cirurgia , Masculino , Idoso , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/efeitos adversos , Reoperação/métodos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Fraturas do Fêmur/cirurgia , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Idoso de 80 Anos ou mais , Desenho de Prótese
2.
Opt Express ; 30(2): 1499-1510, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35209308

RESUMO

We present Rydberg-state electromagnetically-induced-transparency (EIT) measurements examining the effects of laser polarization, magnetic fields, laser intensities, and the optical density of the thermal 87Rb medium. Two counter-propagating laser beams with wavelengths of 480 nm and 780 nm were employed to sweep the spectrum across the Rydberg states |33D3/2〉 and |33D5/2〉. An analytic transmission expression well fits the Rydberg-EIT spectra with multiple transitions under different magnetic fields and laser polarization after accounting for the relevant Clebsch-Gordan coefficients, Zeeman splittings, and Doppler shifts. In addition, the high-contrast Rydberg EIT can be optimized with the probe laser intensity and optical density. Rydberg EIT peak height was achieved at 13%, which is more than twice as high as the maximum peak height at room temperature. A quantitative theoretical model is employed to represent the spectra properties and to predict well the optimization conditions. A Rydberg EIT spectrum with high contrast in real time can be served as a quantum sensor to detect the electromagnetic field within an environment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA