1.
Front Cardiovasc Med ; 9: 890799, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35722127

RESUMO

Background: Intravascular imaging has been used to assess the morphology of lesions causing an acute coronary syndrome (ACS) in native vessels (NV) and identify differences between plaques that ruptured (PR) and caused an event and those that ruptured without clinical manifestations. However, there is no data about the morphological and physiological characteristics of neoatherosclerotic plaques that ruptured (PR-NA) which constitute a common cause of stent failure. Methods: We retrospectively analyzed data from patients admitted with an acute myocardial infarction that had optical coherence tomography (OCT) imaging of the culprit vessel before balloon pre-dilation. OCT pullbacks showing PR were segmented at every 0.4 mm. The extent of the formed cavity, lipid and calcific tissue, thrombus, and macrophages were measured, and the fibrous cap thickness (FCT) and the incidence of micro-channels and cholesterol crystals were reported. These data were used to reconstruct a representative model of the native and neoatherosclerotic lesion geometry that was processed with computational fluid dynamics (CFD) techniques to estimate the distribution of the endothelial shear stress and plaque structural stress. Result: Eighty patients were included in the present analysis: 56 had PR in NV (PR-NV group) and 24 in NA segments (PR-NA group). The PR-NV group had a larger minimum lumen area (2.93 ± 2.03 vs. 2.00 ± 1.26 mm2, p = 0.015) but similar lesion length and area stenosis compared to PR-NA group. The mean FCT (186 ± 65 vs. 232 ± 80 µm, p = 0.009) and the lipid index was smaller (16.7 ± 13.8 vs. 25.9 ± 14.1, p = 0.008) while the of calcific index (8.3 ± 9.5 vs. 2.2 ± 1.6%, p = 0.002) and the incidence of micro-channels (41.4 vs. 12.5%, p = 0.013) was higher in the PR-NV group. Conversely, there was no difference in the incidence of cholesterol crystals, thrombus burden or the location of the rupture site between groups. CFD analysis revealed higher maximum endothelial shear stress (19.1 vs. 11.0 Pa) and lower maximum plaque structural stress (38.8 vs. 95.1 kPa) in the PR-NA compared to the PR-NV model. Conclusion: We reported significant morphological and physiological differences between culprit ruptured plaques in native and stented segments. Further research is needed to better understand the causes of these differences and the mechanisms regulating neoatherosclerotic lesion destabilization.

2.
Int J Comput Assist Radiol Surg ; 17(9): 1611-1617, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35397710

RESUMO

PURPOSE: Multimodality imaging of the vascular system is a rapidly growing area of innovation and research, which is increasing with awareness of the dangers of ionizing radiation. Phantom models that are applicable across multiple imaging modalities facilitate testing and comparisons in pre-clinical studies of new devices. Additionally, phantom models are of benefit to surgical trainees for gaining experience with new techniques. We propose a temperature-stable, high-fidelity method for creating complex abdominal aortic aneurysm phantoms that are compatible with both radiation-based, and ultrasound-based imaging modalities, using low cost materials. METHODS: Volumetric CT data of an abdominal aortic aneurysm were acquired. Regions of interest were segmented to form a model compatible with 3D printing. The novel phantom fabrication method comprised a hybrid approach of using 3D printing of water-soluble materials to create wall-less, patient-derived vascular structures embedded within tailored tissue-mimicking materials to create realistic surrounding tissues. A non-soluble 3-D printed spine was included to provide a radiological landmark. RESULTS: The phantom was found to provide realistic appearances with intravascular ultrasound, computed tomography and transcutaneous ultrasound. Furthermore, the utility of this phantom as a training model was demonstrated during a simulated endovascular aneurysm repair procedure with image fusion. CONCLUSION: With the hybrid fabrication method demonstrated here, complex multimodality imaging patient-derived vascular phantoms can be successfully fabricated. These have potential roles in the benchtop development of emerging imaging technologies, refinement of novel minimally invasive surgical techniques and as clinical training tools.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Imagens de Fantasmas , Impressão Tridimensional
3.
Catheter Cardiovasc Interv ; 99(2): 391-396, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34967091

RESUMO

BACKGROUND: The impact of COVID-19 on the diagnosis and management of nonculprit lesions remains unclear. OBJECTIVES: This study sought to evaluate the management and outcomes of patients with nonculprit lesions during the COVID-19 pandemic. METHODS: We conducted a retrospective observational analysis of consecutive primary percutaneous coronary intervention (PPCI) pathway activations across the heart attack center network in London, UK. Data from the study period in 2020 were compared with prepandemic data in 2019. The primary outcome was the rate of nonculprit lesion percutaneous coronary intervention (PCI) and secondary outcomes included major adverse cardiovascular events. RESULTS: A total of 788 patients undergoing PPCI were identified, 209 (60%) in 2020 cohort and 263 (60%) in 2019 cohort had nonculprit lesions (p = .89). There was less functional assessment of the significance of nonculprit lesions in the 2020 cohort compared to 2019 cohort; in 8% 2020 cohort versus 15% 2019 cohort (p = .01). There was no difference in rates of PCI for nonculprit disease in the 2019 and 2020 cohorts (31% vs 30%, p = .11). Patients in 2020 cohort underwent nonculprit lesion PCI sooner than the 2019 cohort (p < .001). At 6 months there was higher rates of unplanned revascularization (4% vs. 2%, p = .05) and repeat myocardial infarction (4% vs. 1%, p = .02) in the 2019 cohort compared to 2020 cohort. CONCLUSION: Changes to clinical practice during the COVID-19 pandemic were associated with reduced rates of unplanned revascularization and myocardial infarction at 6-months follow-up, and despite the pandemic, there was no difference in mortality, suggesting that it is not only safe but maybe more efficacious.


Assuntos
COVID-19 , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Londres/epidemiologia , Infarto do Miocárdio/etiologia , Pandemias , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , SARS-CoV-2 , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento
4.
Atherosclerosis ; 322: 24-30, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33706080

RESUMO

BACKGROUND AND AIMS: There is some evidence of the implications of wall shear stress (WSS) derived from three-dimensional quantitative coronary angiography (3D-QCA) models in predicting adverse cardiovascular events. This study investigates the efficacy of 3D-QCA-derived WSS in detecting lesions with a borderline negative fractional flow reserve (FFR: 0.81-0.85) that progressed and caused events. METHODS: In this retrospective cohort study, we identified 548 patients who had at least one lesion with an FFR 0.81-0.85 and complete follow-up data; 293 lesions (286 patients) with suitable angiographic characteristics were reconstructed using a dedicated 3D-QCA software and included in the analysis. In the reconstructed models blood flow simulation was performed and the value of 3D-QCA variables and WSS distribution in predicting events was examined. The primary endpoint of the study was the composite of cardiac death, target lesion related myocardial infarction or clinically indicated target lesion revascularization. RESULTS: During a median follow-up of 49.4 months, 37 events were reported. Culprit lesions had a greater area stenosis [(AS), 66.1% (59.5-72.3) vs 54.8% (46.5-63.2), p<0.001], smaller minimum lumen area [(MLA), 1.66 mm2 (1.45-2.30) vs 2.10 mm2 (1.69-2.70), p=0.011] and higher maximum WSS [9.0 Pa (5.10-12.46) vs 5.0 Pa (3.37-7.54), p < 0.001] than those that remained quiescent. In multivariable analysis, AS [hazard ratio (HR): 1.06, 95% confidence interval (CI): 1.03-1.10, p=0.001] and maximum WSS (HR: 1.08, 95% CI: 1.02-1.14, p=0.012) were the only independent predictors of the primary endpoint. Lesions with an increased AS (≥58.6%) that were exposed to high WSS (≥7.69Pa) were more likely to progress and cause events (27.8%) than those with a low AS exposed to high WSS (7.4%) or those exposed to low WSS that had increased (12.8%) or low AS (2.7%, p<0.001). CONCLUSIONS: This study for the first time highlights the potential value of 3D-QCA-derived WSS in detecting, among lesions with a borderline negative FFR, those that cause cardiovascular events.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
5.
OSA Contin ; 4(9): 2488-2495, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37841369

RESUMO

All-optical ultrasound transducers are well-suited for use in imaging during minimally invasive surgical procedures. This requires highly miniaturised and flexible devices. Here we present optical ultrasound transmitters for imaging applications based on modified optical fibre distal tips which allow for larger transmitter element sizes, whilst maintaining small diameter proximal optical fibre. Three optical ultrasound transmitter configurations were compared; a 400 µm core optical fibre, a 200 µm core optical fibre with a 400 µm core optical fibre distal tip, and a 200 µm core optical fibre with a 400 µm core capillary distal tip. All the transmitters used a polydimethylsiloxane-dye composite material for ultrasound generation. The material comprised a photostable infra-red absorbing dye to provide optical absorption for the ultrasound transduction. The generated ultrasound beam profile for the three transmitters was compared, demonstrating similar results, with lateral beam widths <1.7 mm at a depth of 10 mm. The composite material demonstrates a promising alternative to previously reported materials, generating ultrasound pressures exceeding 2 MPa, with corresponding bandwidths ca. 30 MHz. These highly flexible ultrasound transmitters can be readily incorporated into medical devices with small lateral dimensions.

6.
Front Cardiovasc Med ; 7: 525530, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33173786

RESUMO

Conventional intravascular ultrasound (IVUS) devices use piezoelectric transducers to electrically generate and receive US. With this paradigm, there are numerous challenges that restrict improvements in image quality. First, with miniaturization of the transducers to reduce device size, it can be challenging to achieve the sensitivities and bandwidths required for large tissue penetration depths and high spatial resolution. Second, complexities associated with manufacturing miniaturized electronic transducers can have significant cost implications. Third, with increasing interest in molecular characterization of tissue in-vivo, it has been challenging to incorporate optical elements for multimodality imaging with photoacoustics (PA) or near-infrared spectroscopy (NIRS) whilst maintaining the lateral dimensions suitable for intracoronary imaging. Optical Ultrasound (OpUS) is a new paradigm for intracoronary imaging. US is generated at the surface of a fiber optic transducer via the photoacoustic effect. Pulsed or modulated light is absorbed in an engineered coating on the fiber surface and converted to thermal energy. The subsequent temperature rise leads to a pressure rise within the coating, which results in a propagating ultrasound wave. US reflections from imaged structures are received with optical interferometry. With OpUS, high bandwidths (31.5 MHz) and pressures (21.5 MPa) have enabled imaging with axial resolutions better than 50 µm and at depths >20 mm. These values challenge those of conventional 40 MHz IVUS technology and show great potential for future clinical application. Recently developed nanocomposite coating materials, that are highly transmissive at light wavelengths used for PA and NIRS light, can facilitate multimodality imaging, thereby enabling molecular characterization.

7.
Open Heart ; 7(2)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33106441

RESUMO

OBJECTIVES: To understand the impact of COVID-19 on delivery and outcomes of primary percutaneous coronary intervention (PPCI). Furthermore, to compare clinical presentation and outcomes of patients with ST-segment elevation myocardial infarction (STEMI) with active COVID-19 against those without COVID-19. METHODS: We systematically analysed 348 STEMI cases presenting to the PPCI programme in London during the peak of the pandemic (1 March to 30 April 2020) and compared with 440 cases from the same period in 2019. Outcomes of interest included ambulance response times, timeliness of revascularisation, angiographic and procedural characteristics, and in-hospital clinical outcomes RESULTS: There was a 21% reduction in STEMI admissions and longer ambulance response times (87 (62-118) min in 2020 vs 75 (57-95) min in 2019, p<0.001), but that this was not associated with a delays in achieving revascularisation once in hospital (48 (34-65) min in 2020 vs 48 (35-70) min in 2019, p=0.35) or increased mortality (10.9% (38) in 2020 vs 8.6% (38) in 2019, p=0.28). 46 patients with active COVID-19 were more thrombotic and more likely to have intensive care unit admissions (32.6% (15) vs 9.3% (28), OR 5.74 (95%CI 2.24 to 9.89), p<0.001). They also had increased length of stay (4 (3-9) days vs 3 (2-4) days, p<0.001) and a higher mortality (21.7% (10) vs 9.3% (28), OR 2.72 (95% CI 1.25 to 5.82), p=0.012) compared with patients having PPCI without COVID-19. CONCLUSION: These findings suggest that PPCI pathways can be maintained during unprecedented healthcare emergencies but confirms the high mortality of STEMI in the context of concomitant COVID-19 infection characterised by a heightened state of thrombogenicity.


Assuntos
Infecções por Coronavirus , Procedimentos Clínicos/organização & administração , Prestação Integrada de Cuidados de Saúde/organização & administração , Avaliação de Processos e Resultados em Cuidados de Saúde/organização & administração , Pandemias , Intervenção Coronária Percutânea , Pneumonia Viral , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Idoso , Ambulâncias/organização & administração , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/mortalidade , Infecções por Coronavirus/terapia , Infecções por Coronavirus/transmissão , Bases de Dados Factuais , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Londres/epidemiologia , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pneumonia Viral/diagnóstico , Pneumonia Viral/mortalidade , Pneumonia Viral/terapia , Pneumonia Viral/transmissão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Trombose/mortalidade , Trombose/terapia , Fatores de Tempo , Tempo para o Tratamento/organização & administração , Resultado do Tratamento
8.
J Biomed Opt ; 24(2): 1-4, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30770678

RESUMO

Microscopic and mesoscale optical imaging techniques allow for three-dimensional (3-D) imaging of biological tissue across millimeter-scale regions, and imaging phantom models are invaluable for system characterization and clinical training. Phantom models that replicate complex 3-D geometries with both structural and molecular contrast, with resolution and lateral dimensions equivalent to those of imaging techniques (<20 µm), have proven elusive. We present a method for fabricating phantom models using a combination of two-photon polymerization (2PP) to print scaffolds, and microinjection of tailored tissue-mimicking materials to simulate healthy and diseased tissue. We provide a first demonstration of the capabilities of this method with intravascular optical coherence tomography, an imaging technique widely used in clinical practice. We describe the design, fabrication, and validation of three types of phantom models: a first with subresolution wires (5- to 34-µm diameter) arranged circumferentially, a second with a vessel side-branch, and a third containing a lipid inclusion within a vessel. Silicone hybrid materials and lipids, microinjected within a resin framework created with 2PP, served as tissue-mimicking materials that provided realistic optical scattering and absorption. We demonstrate that optical phantom models made with 2PP and microinjected tissue-mimicking materials can simulate complex anatomy and pathology with exquisite detail.


Assuntos
Diagnóstico por Imagem/métodos , Imageamento Tridimensional/métodos , Imagem Óptica/métodos , Imagens de Fantasmas , Biomimética , Desenho Assistido por Computador , Percepção de Profundidade , Humanos , Lipídeos/química , Modelos Teóricos , Fótons , Impressão Tridimensional , Refratometria , Silicones/química , Tomografia de Coerência Óptica/métodos