Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 371
Filtrar
1.
J Arthroplasty ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38735549

RESUMO

BACKGROUND: Dexamethasone (DEX) has demonstrated promise with respect to decreasing postoperative thromboembolic complications following total joint arthroplasty (TJA). Therefore, the aim of this study was to investigate the effects of perioperative intravenous DEX on rates of pulmonary embolism (PE) and deep vein thrombosis (DVT) after primary TJA in patients who have a history of venous thromboembolism (VTE). METHODS: Patients who have a history of VTE who underwent primary, elective TJA from 2015 to 2021 were identified using a commercial healthcare database. Patients were divided based on receipt of perioperative intravenous DEX [DEX(+) versus DEX(-)] on the day of index TJA. Patient demographics and hospital factors were collected. The 90-day risk of postoperative complications, readmission, and in-hospital mortality were compared. RESULTS: Overall, 70,147 patients who had a history of VTE underwent TJA, of which 40,607 (57.89%) received DEX and 29,540 (42.11%) did not. The DEX(+) patients were younger (67 ± 9.8 versus 68 ± 9.9 years, P < 0.001) and had a significantly shorter length of stay compared to the DEX(-) patients (1.8 ± 1.6 versus 2.2 ± 1.8 days, P < 0.001). The DEX(+) patients demonstrated lower rates of PE (1.37 versus 1.75%, P < 0.001) and DVT (2.37 versus 3.01%, P < 0.001) compared to DEX(-) patients. The DEX(+) patients experienced a lower risk of PE (adjusted odds ratio [aOR] 0.78, 95% confidence interval [95%-CI]: 0.66 to 0.93, P = 0.006) and DVT (aOR: 0.84, 95%-CI: 0.74 to 0.95, P = 0.006) compared to DEX(-) patients. The DEX(+) patients demonstrated no differences in the odds of surgical site infection, periprosthetic joint infection, or sepsis compared to the DEX(-) patients (P > 0.05). CONCLUSION: The administration of DEX was associated with a decreased risk of PE and DVT in patients who have a history of VTE who underwent TJA. These data warrant further study investigating the postoperative benefits of perioperative DEX administration for high-risk patients undergoing TJA.

2.
BMC Public Health ; 24(1): 1276, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730410

RESUMO

BACKGROUND: Prescription drug monitoring programs (PDMPs) are state-level databases that track and inform prescribing practices to reduce prescription drug diversion and misuse. To our knowledge, only three studies have examined the impact of PDMPs on opioid-related outcomes among adolescents, and none have focused on prescription pain medication misuse among adolescents. METHODS: This study leveraged data from the 2019 National Youth Risk Behavior Survey (YRBS) to explore the associations between five categories of PDMP dimensions and the prevalence of self-reported prescription pain medication misuse. Demographic factors' associations with self-reported prescription pain medication misuse were also examined. RESULTS: In 2019, none of the PDMP dimensions were associated with self-reported prescription pain medication misuse among U.S. high school students, adjusting for gender, grade, race/ethnicity, and sexual orientation. CONCLUSIONS: None of the five PDMP dimensions were associated with lower prescription pain medication misuse, however further research is needed, especially as new YRBS data become available.


Assuntos
Analgésicos Opioides , Uso Indevido de Medicamentos sob Prescrição , Programas de Monitoramento de Prescrição de Medicamentos , Estudantes , Humanos , Adolescente , Masculino , Feminino , Estados Unidos , Uso Indevido de Medicamentos sob Prescrição/estatística & dados numéricos , Programas de Monitoramento de Prescrição de Medicamentos/estatística & dados numéricos , Analgésicos Opioides/uso terapêutico , Estudantes/estatística & dados numéricos , Estudantes/psicologia , Inquéritos e Questionários
3.
bioRxiv ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38712109

RESUMO

Background: The understanding of how varying radiation beam parameter settings affect the induction and magnitude of the FLASH effect remains limited. Purpose: We sought to evaluate how the magnitude of radiation-induced gastrointestinal (GI) toxicity (RIGIT) depends on the interplay between mean dose rate (MDR) and dose per pulse (DPP). Methods: C57BL/6J mice were subjected to total abdominal irradiation (11-14 Gy single fraction) under conventional irradiation (low DPP and low MDR, CONV) and various combinations of DPP and MDR up to ultra-high-dose-rate (UHDR) beam conditions. The effects of DPP were evaluated for DPPs of 1-6 Gy while the total dose and MDR were kept constant; the effects of MDR were evaluated for the range 0.3- 1440 Gy/s while the total dose and DPP were kept constant. RIGIT was quantified in non-tumor-bearing mice through the regenerating crypt assay and survival assessment. Tumor response was evaluated through tumor growth delay. Results: Within each tested total dose using a constant MDR (>100 Gy/s), increasing DPP led to better sparing of regenerating crypts, with a more prominent effect seen at 12 and 14 Gy TAI. However, at fixed DPPs >4 Gy, similar sparing of crypts was demonstrated irrespective of MDR (from 0.3 to 1440 Gy/s). At a fixed high DPP of 4.7 Gy, survival was equivalently improved relative to CONV for all MDRs from 0.3 Gy/s to 104 Gy/s, but at a lower DPP of 0.93 Gy, increasing MDR produced a greater survival effect. We also confirmed that high DPP, regardless of MDR, produced the same magnitude of tumor growth delay relative to CONV using a clinically relevant melanoma mouse model. Conclusions: This study demonstrates the strong influence that the beam parameter settings have on the magnitude of the FLASH effect. Both high DPP and UHDR appeared independently sufficient to produce FLASH sparing of GI toxicity, while isoeffective tumor response was maintained across all conditions.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38626438

RESUMO

INTRODUCTION: Venous thromboembolism (VTE) remains a dangerous complication after total hip arthroplasty (THA), despite advances in chemoprophylactic measures. This study aimed to identify risk factors of developing pulmonary embolism (PE) and deep vein thrombosis (DVT) after THA using a modern cohort of patients reflecting contemporary practices. METHODS: The Premier Healthcare Database was queried for primary, elective THAs from January 1st, 2015, to December 31st, 2021. Patients who developed PE or DVT within 90 days of THA were compared with patients who did not develop any postoperative VTE. Differences in patient demographics, comorbidities, hospital factors, perioperative medications, chemoprophylactic agents, and allogeneic blood transfusion were compared between cohorts. Multivariable logistic regression models were used to identify independent risk factors of PE and DVT. In total, 544,298 THAs were identified, of which 1,129 (0.21%) developed a PE and 1,799 (0.33%) developed a DVT. RESULTS: Patients diagnosed with a PE had significantly higher rates of in-hospital death (2.6% vs 0.1%, P < 0.001) compared with those without a PE. Age (adjusted odds ratio: 1.02 per year, 95% confidence interval [CI]: 1.01 to 1.03) and Black race (aOR: 1.52, 95% CI: 1.24 to 1.87) were associated with an increased risk of PE. Comorbidities associated with increased risk of PE included chronic pulmonary disease (aOR: 1.58, 95% CI: 1.36 to 1.84), pulmonary hypertension (aOR: 2.06, 95% CI: 1.39 to 3.04), and history of VTE (aOR: 2.38, 95% CI: 1.98 to 2.86). Allogeneic blood transfusion (aOR: 2.40, 95% CI: 1.88 to 3.06) was also associated with an increased risk of PE while dexamethasone utilization was associated with a reduced risk (aOR: 0.83, 95% CI: 0.73 to 0.95). DISCUSSION: Increasing age; Black race; allogeneic blood transfusion; and comorbidities, including chronic pulmonary disease, pulmonary hypertension, and history of VTE, were independent risk factors of PE after THA. Given the increased mortality associated with PE, patients should be carefully evaluated for these factors and managed with an appropriate chemoprophylactic regimen.

5.
J Clin Med ; 13(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38542000

RESUMO

Background: Peripheral nerve injury (PNI) following revision total hip arthroplasty (rTHA) can be a devastating complication. This study assessed the frequency of and risk factors for postoperative PNI following rTHA. Methods: Patients who underwent rTHA from 2003 to 2015 were identified using the National Inpatient Sample (NIS). Demographics, medical history, surgical details, and complications were compared between patients who sustained a PNI and those who did not, to identify risk factors for the development of PNI after rTHA. Results: Overall, 112,310 patients who underwent rTHA were identified, 929 (0.83%) of whom sustained a PNI. Univariate analysis found that younger patients (p < 0.0001), females (p = 0.025), and those with a history of flexion contracture (0.65% vs. 0.22%, p = 0.005), hip dislocation (24.0% vs. 18.0%, p < 0.001), and spine conditions (4.8% vs. 2.7%, p < 0.001) had significantly higher rates of PNI. In-hospital complications associated with PNI included postoperative hematoma (2.6% vs. 1.2%, p < 0.0001), postoperative seroma (0.75% vs. 0.30%, p = 0.011), superficial wound dehiscence (0.65% vs. 0.23%, p = 0.008), and postoperative anemia (36.1% vs. 32.0%, p = 0.007). Multivariate analysis demonstrated that a history of pre-existing spine conditions (aOR: 1.7; 95%-CI: 1.3-2.4, p < 0.001), prior dislocation (aOR 1.5; 95%-CI: 1.3-1.7, p < 0.001), postoperative anemia (aOR 1.2; 95%-CI: 1.0-1.4, p = 0.01), and hematoma (aOR 2.1; 95%-CI: 1.4-3.2, p < 0.001) were associated with increased risk for PNI. Conclusions: Our findings align with the existing literature, affirming that sciatic nerve injury is the prevailing neuropathic complication after total hip arthroplasty (THA). Furthermore, we observed a 0.83% incidence of PNI following rTHA and identified pre-existing spine conditions, prior hip dislocation, postoperative anemia, or hematoma as risk factors. Orthopedic surgeons may use this information to guide their discussion of PNI following rTHA, especially in high-risk patients.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38493902

RESUMO

PURPOSE: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom. METHODS AND MATERIALS: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (∼1.02 g/cm3) and polylactic acid (∼1.24 g/cm3) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid (∼0.64 g/cm3). Hounsfield units (HU), densities, and print-to-print stability of the phantoms were assessed. Three institutions were each provided a phantom and each institution performed 2 replicates of irradiations at selected anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. RESULTS: Compared with the reference CT scan, CT scans of the phantom demonstrated mass density differences of 0.10 g/cm3 for bone, 0.12 g/cm3 for lung, and 0.03 g/cm3 for soft tissue regions. Differences in HU between phantoms were <10 HU for soft tissue and bone, with lung showing the most variation (54 HU), but with minimal effect on dose distribution (<0.5%). Mean differences between FLASH and CONV decreased from the first to the second replicate (4.3%-1.2%), and differences from the prescribed dose decreased for both CONV (3.6%-2.5%) and FLASH (6.4%-2.7%). Total dose accuracy suggests consistent pulse dose and pulse number, although these were not specifically assessed. Positioning variability was observed, likely due to the absence of robust positioning aids or image guidance. CONCLUSIONS: This study marks the first dosimetric audit for FLASH using a nonhomogeneous phantom, challenging conventional calibration practices reliant on homogeneous phantoms. The comparison protocol offers a framework for credentialing multi-institutional studies in FLASH preclinical research to enhance reproducibility of biologic findings.

7.
J Hepatol ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38527527

RESUMO

BACKGROUND & AIMS: Factors predicting HBsAg seroclearance after treatment cessation, irrespective of nucleos(t)ide analogue (NA) resumption, have important clinical implications. We evaluated predictors of long-term HBsAg seroclearance after entecavir cessation. METHODS: This study followed-up Chinese patients with chronic hepatitis B from two previous studies of entecavir cessation. All patients were non-cirrhotic, HBeAg-negative, with undetectable HBV DNA (<20 IU/ml) at end-of-treatment (EOT). They were monitored closely for 48 weeks with regular HBV DNA, quantitative HBsAg (qHBsAg) and alanine aminotransferase (ALT) measurements. Entecavir was resumed at HBV DNA >2,000 IU/ml, irrespective of ALT levels. After the initial 48 weeks, patients were assessed every 6 months, regardless of entecavir resumption, to monitor for HBsAg seroclearance. RESULTS: A total of 194 patients (63.4% male, mean age 49.9 years, on entecavir for a median of 47.2 months) were recruited; 94 (48.5%) and 158 (81.4%) patients had EOT qHBsAg <100 IU/ml and <1,000 IU/ml, respectively; 151 (77.8%) patients were eventually resumed on entecavir. After follow-up for a median of 70.7 (51.0-118.2) months, 28 (14.4%) patients had HBsAg seroclearance. qHBsAg levels at weeks 36 and 48 after EOT independently predicted HBsAg seroclearance (both p <0.01), whereas qHBsAg from EOT to week 24 only trended towards statistical significance. The ratio of ALT/qHBsAg at all time points from EOT to week 48 independently predicted HBsAg seroclearance (hazard ratios ranging from 1.003-1.028, all p <0.01) with excellent diagnostic performance (area under the receiver-operating characteristic curve 0.799-0.933, negative predictive value >90% at different time points), regardless of whether entecavir was resumed. CONCLUSIONS: The ALT/qHBsAg ratio after entecavir cessation predicts HBsAg seroclearance, even in patients who were resumed on treatment. Its use may mitigate the risk of severe hepatitis flares in patients managed by observation without treatment resumption. IMPACT AND IMPLICATIONS: Current predictors of HBsAg seroclearance after finite nucleos(t)ide analogue (NA) therapy have suboptimal predictive value. We demonstrated that the ALT/qHBsAg ratio may be able to reflect the balance between host control and virological activity. The ALT/qHBsAg ratio at different time points from end-of-treatment till week 48 independently and accurately predicted HBsAg seroclearance in patients who have stopped entecavir. The ALT/qHBsAg ratio may be utilized by clinicians for patient selection and retreatment decisions in finite NA therapy.

8.
Radiol Artif Intell ; 6(3): e230333, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38446044

RESUMO

Purpose To develop and externally test a scan-to-prediction deep learning pipeline for noninvasive, MRI-based BRAF mutational status classification for pediatric low-grade glioma. Materials and Methods This retrospective study included two pediatric low-grade glioma datasets with linked genomic and diagnostic T2-weighted MRI data of patients: Dana-Farber/Boston Children's Hospital (development dataset, n = 214 [113 (52.8%) male; 104 (48.6%) BRAF wild type, 60 (28.0%) BRAF fusion, and 50 (23.4%) BRAF V600E]) and the Children's Brain Tumor Network (external testing, n = 112 [55 (49.1%) male; 35 (31.2%) BRAF wild type, 60 (53.6%) BRAF fusion, and 17 (15.2%) BRAF V600E]). A deep learning pipeline was developed to classify BRAF mutational status (BRAF wild type vs BRAF fusion vs BRAF V600E) via a two-stage process: (a) three-dimensional tumor segmentation and extraction of axial tumor images and (b) section-wise, deep learning-based classification of mutational status. Knowledge-transfer and self-supervised approaches were investigated to prevent model overfitting, with a primary end point of the area under the receiver operating characteristic curve (AUC). To enhance model interpretability, a novel metric, center of mass distance, was developed to quantify the model attention around the tumor. Results A combination of transfer learning from a pretrained medical imaging-specific network and self-supervised label cross-training (TransferX) coupled with consensus logic yielded the highest classification performance with an AUC of 0.82 (95% CI: 0.72, 0.91), 0.87 (95% CI: 0.61, 0.97), and 0.85 (95% CI: 0.66, 0.95) for BRAF wild type, BRAF fusion, and BRAF V600E, respectively, on internal testing. On external testing, the pipeline yielded an AUC of 0.72 (95% CI: 0.64, 0.86), 0.78 (95% CI: 0.61, 0.89), and 0.72 (95% CI: 0.64, 0.88) for BRAF wild type, BRAF fusion, and BRAF V600E, respectively. Conclusion Transfer learning and self-supervised cross-training improved classification performance and generalizability for noninvasive pediatric low-grade glioma mutational status prediction in a limited data scenario. Keywords: Pediatrics, MRI, CNS, Brain/Brain Stem, Oncology, Feature Detection, Diagnosis, Supervised Learning, Transfer Learning, Convolutional Neural Network (CNN) Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Criança , Masculino , Feminino , Neoplasias Encefálicas/diagnóstico por imagem , Estudos Retrospectivos , Proteínas Proto-Oncogênicas B-raf/genética , Glioma/diagnóstico , Aprendizado de Máquina
9.
Arthroplast Today ; 26: 101336, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38440288

RESUMO

Background: Inpatient total hip arthroplasty (THA) and total knee arthroplasty (TKA) practices were dramatically affected in the United States in 2020 as elective surgeries were paused in response to the COVID-19 pandemic. This study sought to provide an updated estimate of inpatient total joint arthroplasty (TJA) case volumes in the United States in 2020. Methods: A retrospective cohort study was performed by identifying all adult patients who underwent primary, elective TJA from January 1st, 2017 to December 31st, 2020, using the National Inpatient Sample. Monthly and annual case volumes were reported with descriptive statistics. Baseline case volumes were established by taking the average number of monthly cases performed in 2017, 2018, and 2019. These monthly averages were compared to 2020 values. Results: From 2017 to 2019, the average case volume was 1,056,669 cases per year (41.0% THA, 59.0% TKA) and 88,055 cases per month. In 2020, 535,441 cases were identified (45.4% THA, 54.6% TKA), corresponding to a 49.3% reduction from the 2017-2019 annual average. Monthly cases decreased to 4515 in April during the "first wave" of COVID-19, corresponding to a 94.8% decrease from prior years. In June, cases rebounded to 55,520 before decreasing again in July to 50,100 during the "second wave" of COVID-19. During the "third wave," COVID-19 cases decreased month-over-month from October through December (56.5% decrease). Conclusions: This updated estimate identified a 49.3% decrease in inpatient TJA cases in 2020 compared to prior years. This is similar to the 46.5-47.7% decrease in case volume previously reported.

10.
Med Phys ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507253

RESUMO

BACKGROUND: Dosimetry in ultra-high dose rate (UHDR) beamlines is significantly challenged by limitations in real-time monitoring and accurate measurement of beam output, beam parameters, and delivered doses using conventional radiation detectors, which exhibit dependencies in ultra-high dose-rate (UHDR) and high dose-per-pulse (DPP) beamline conditions. PURPOSE: In this study, we characterized the response of the Exradin W2 plastic scintillator (Standard Imaging, Inc.), a water-equivalent detector that provides measurements with a time resolution of 100 Hz, to determine its feasibility for use in UHDR electron beamlines. METHODS: The W2 scintillator was exposed to an UHDR electron beam with different beam parameters by varying the pulse repetition frequency (PRF), pulse width (PW), and pulse amplitude settings of an electron UHDR linear accelerator system. The response of the W2 scintillator was evaluated as a function of the total integrated dose delivered, DPP, and mean and instantaneous dose rate. To account for detector radiation damage, the signal sensitivity (pC/Gy) of the W2 scintillator was measured and tracked as a function of dose history. RESULTS: The W2 scintillator demonstrated mean dose rate independence and linearity as a function of integrated dose and DPP for DPP ≤ 1.5 Gy (R2 > 0.99) and PRF ≤ 90 Hz. At DPP > 1.5 Gy, nonlinear behavior and signal saturation in the blue and green signals as a function of DPP, PRF, and integrated dose became apparent. In the absence of Cerenkov correction, the W2 scintillator exhibited PW dependence, even at DPP values <1.5 Gy, with a difference of up to 31% and 54% in the measured blue and green signal for PWs ranging from 0.5 to 3.6 µs. The change in signal sensitivity of the W2 scintillator as a function of accumulated dose was approximately 4%/kGy and 0.3%/kGy for the measured blue and green signal responses, respectively, as a function of integrated dose history. CONCLUSION: The Exradin W2 scintillator can provide output measurements that are both dose rate independent and linear in response if the DPP is kept ≤1.5 Gy (corresponding to a mean dose rate up to 290 Gy/s in the used system), as long as proper calibration is performed to account for PW and changes in signal sensitivity as a function of accumulated dose. For DPP > 1.5 Gy, the W2 scintillator's response becomes nonlinear, likely due to limitations in the electrometer related to the high signal intensity.

11.
ArXiv ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38495573

RESUMO

Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates (DR-) above 100 Gy/s and doses per pulse (Dp) exceeding 1.5 Gy typical of UHDR (FLASH)-RT. The aim of this study was to characterize a novel scintillator dosimetry system with the potential of accommodating UHDRs. Methods and Materials: A thorough dosimetric characterization of the system was performed on an UHDR electron beamline. The system's response as a function of dose, DR-,Dp, and the pulse dose rate DRp was investigated, together with the system's dose sensitivity (signal per unit dose) as a function of dose history. The capabilities of the system for time-resolved dosimetric readout were also evaluated. Results: Within a tolerance of ±3%, the system exhibited dose linearity and was independent of DR- and Dp within the tested ranges of 1.8-1341 Gy/s and 0.005-7.68 Gy, respectively. A 6% reduction in the signal per unit dose was observed as DRp was increased from 8.9e4-1.8e6 Gy/s. Additionally, the dose delivered per integration window of the continuously sampling photodetector had to remain between 0.028 and 11.64 Gy to preserve a stable signal response per unit dose. The system accurately measured Dp of individual pulses delivered at up to 120 Hz. The day-to-day variation of the signal per unit dose at a reference setup varied by up to ±13% but remained consistent (<±2%) within each day of measurements and showed no signal loss as a function of dose history. Conclusions: With daily calibrations and DRp specific correction factors, the system reliably provides real-time, millisecond-resolved dosimetric measurements of pulsed conventional and UHDR beams from typical electron linacs, marking an important advancement in UHDR dosimetry and offering diverse applications to FLASH-RT and related fields.

12.
J Surg Oncol ; 129(6): 1150-1158, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38385654

RESUMO

BACKGROUND AND OBJECTIVES: This study aimed to evaluate the postoperative complications associated with administering intravenous (IV) tranexamic acid (TXA) in patients undergoing surgical fixation for neoplastic pathologic fractures of the lower extremities. METHODS: Patients ≥18 years old who underwent surgical intervention for neoplastic pathologic lower extremity fractures from 2015 to 2021 were identified using the Premier Healthcare Database. This cohort was divided by TXA receipt on the index surgery day. Patient demographics, hospital factors, patient comorbidities, and 90-day complications were assessed and compared between the cohorts. RESULTS: From 2015 to 2021, 4497 patients met inclusion criteria (769 TXA[+] and 3728 TXA[-]). Following propensity score matching, patients who received TXA had a significantly shorter length of stay than those who did not (7.6 ± 7.3 days vs. 9.0 ± 15.2, p = 0.036). Between the two cohorts, there were no significant differences in comorbidities. Regarding differences in postoperative complications, TXA(+) patients had significantly decreased odds of deep vein thrombosis (DVT) (1.87% vs. 5.46%; odds ratio [OR]:0.33; 95% confidence interval: 0.17-0.62; p = 0.001). CONCLUSION: Administration of IV TXA may be associated with a decreased risk of postoperative DVT without an increased risk of other complications. Orthopedic surgeons should consider the utilization of IV TXA in patients treated surgically for neoplastic pathologic fractures of the lower extremity.


Assuntos
Antifibrinolíticos , Complicações Pós-Operatórias , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/administração & dosagem , Masculino , Feminino , Pessoa de Meia-Idade , Antifibrinolíticos/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Idoso , Fraturas Espontâneas/prevenção & controle , Fraturas Espontâneas/cirurgia , Fraturas Espontâneas/etiologia , Administração Intravenosa , Extremidade Inferior/cirurgia , Seguimentos , Adulto , Prognóstico
13.
World Neurosurg ; 184: 322-330.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342177

RESUMO

BACKGROUND: In recent years, the use of intraoperative computer tomography-guided (CT-guided) navigation has gained significant popularity among health care providers who perform minimally invasive spine surgery. This review aims to identify and analyze trends in the literature related to the widespread adoption of CT-guided navigation in spine surgery, emphasizing the shift from conventional fluoroscopy-based techniques to CT-guided navigation. METHODS: Articles pertaining to this study were identified via a database review and were hierarchically organized based on the number of citations. An "advanced document search" was performed on September 28th, 2022, utilizing Boolean search operator terms. The 25 most referenced articles were combined into a primary list after sorting results in descending order based on the total number of citations. RESULTS: The "Top 25" list for intraoperative CT-guided navigation in spine surgery cumulatively received a total of 2742 citations, with an average of 12 new citations annually. The number of citations ranged from 246 for the most cited article to 60 for the 25th most cited article. The most cited article was a paper by Siewerdsen et al., with 246 total citations, averaging 15 new citations per year. CONCLUSIONS: Intraoperative CT-guided navigation is 1 of many technological advances that is used to increase surgical accuracy, and it has become an increasingly popular alternative to conventional fluoroscopy-based techniques. Given the increasing adoption of intraoperative CT-guided navigation in spine surgery, this review provides impactful evidence for its utility in spine surgery.


Assuntos
Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Fluoroscopia/métodos
14.
Bone Joint J ; 106-B(3 Supple A): 89-96, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423076

RESUMO

Aims: Modular dual-mobility (DM) articulations are increasingly used during total hip arthroplasty (THA). However, concerns remain regarding the metal liner modularity. This study aims to correlate metal artifact reduction sequence (MARS)-MRI abnormalities with serum metal ion levels in patients with DM articulations. Methods: A total of 45 patients (50 hips) with a modular DM articulation were included with mean follow-up of 3.7 years (SD 1.2). Enrolled patients with an asymptomatic, primary THA and DM articulation with over two years' follow-up underwent MARS-MRI. Each patient had serum cobalt, chromium, and titanium levels drawn. Patient satisfaction, Oxford Hip Score, and Forgotten Joint Score-12 (FJS-12) were collected. Each MARS-MRI was independently reviewed by fellowship-trained musculoskeletal radiologists blinded to serum ion levels. Results: Overall, two patients (4.4%) had abnormal periprosthetic fluid collections on MARS-MRI with cobalt levels > 3.0 µg/l. Four patients (8.9%) had MARS-MRI findings consistent with greater trochanteric bursitis, all with cobalt levels < 1.0 µg/l. A seventh patient had a periprosthetic fluid collection with normal ion levels. Of the 38 patients without MARS-MRI abnormalities, 37 (97.4%) had cobalt levels < 1.0 µg/l, while one (2.6%) had a cobalt level of 1.4 µg/l. One patient (2.2%) had a chromium level > 3.0 µg/l and a periprosthetic fluid collection. Of the 41 patients with titanium levels, five (12.2%) had titanium levels > 5.0 µg/l without associated MARS-MRI abnormalities. Conclusion: Periprosthetic fluid collections associated with elevated serum cobalt levels in patients with asymptomatic DM articulations occur infrequently (4.4%), but further assessment is necessary due to implant heterogeneity.


Assuntos
Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Artefatos , Titânio , Cromo , Cobalto , Imageamento por Ressonância Magnética
15.
Front Neurosci ; 18: 1330556, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38332856

RESUMO

Autism spectrum disorder (ASD) is a complex neurodevelopmental condition characterized by diverse clinical features. EEG biomarkers such as spectral power and functional connectivity have emerged as potential tools for enhancing early diagnosis and understanding of the neural processes underlying ASD. However, existing studies yield conflicting results, necessitating a comprehensive, data-driven analysis. We conducted a retrospective cross-sectional study involving 246 children with ASD and 42 control children. EEG was collected, and diverse EEG features, including spectral power and spectral coherence were extracted. Statistical inference methods, coupled with machine learning models, were employed to identify differences in EEG features between ASD and control groups and develop classification models for diagnostic purposes. Our analysis revealed statistically significant differences in spectral coherence, particularly in gamma and beta frequency bands, indicating elevated long range functional connectivity between frontal and parietal regions in the ASD group. Machine learning models achieved modest classification performance of ROC-AUC at 0.65. While machine learning approaches offer some discriminative power classifying individuals with ASD from controls, they also indicate the need for further refinement.

16.
Am J Gastroenterol ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38305278

RESUMO

INTRODUCTION: Both artificial intelligence (AI) and distal attachment devices have been shown to improve adenoma detection rate and reduce miss rate during colonoscopy. We studied the combined effect of Endocuff and AI on enhancing detection rates of various colonic lesions. METHODS: This was a 3-arm prospective randomized colonoscopy study involving patients aged 40 years or older. Participants were randomly assigned in a 1:1:1 ratio to undergo Endocuff with AI, AI alone, or standard high-definition (HD) colonoscopy. The primary outcome was adenoma detection rate (ADR) between the Endocuff-AI and AI groups while secondary outcomes included detection rates of polyp (PDR), sessile serrated lesion (sessile detection rate [SDR]), and advanced adenoma (advanced adenoma detection rate) between the 2 groups. RESULTS: A total of 682 patients were included (mean age 65.4 years, 52.3% male), with 53.7% undergoing diagnostic colonoscopy. The ADR for the Endocuff-AI, AI, and HD groups was 58.7%, 53.8%, and 46.3%, respectively, while the corresponding PDR was 77.0%, 74.0%, and 61.2%. A significant increase in ADR, PDR, and SDR was observed between the Endocuff-AI and AI groups (ADR difference: 4.9%, 95% CI: 1.4%-8.2%, P = 0.03; PDR difference: 3.0%, 95% CI: 0.4%-5.8%, P = 0.04; SDR difference: 6.4%, 95% CI: 3.4%-9.7%, P < 0.01). Both Endocuff-AI and AI groups had a higher ADR, PDR, SDR, and advanced adenoma detection rate than the HD group (all P < 0.01). DISCUSSION: Endocuff in combination with AI further improves various colonic lesion detection rates when compared with AI alone.

17.
Endosc Int Open ; 12(2): E324-E331, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420150

RESUMO

Background and study aims The Bethesda ERCP Skill Assessment Tool (BESAT) is a video-based assessment tool of technical endoscopic retrograde cholangiopancreatography (ERCP) skill with previously established validity evidence. We aimed to assess the discriminative validity of the BESAT in differentiating ERCP skill levels. Methods Twelve experienced ERCP practitioners from tertiary academic centers were asked to blindly rate 43 ERCP videos using the BESAT. ERCP videos consisted of native biliary cannulation and sphincterotomy and were recorded from 10 unique endoscopists of various ERCP experience (from advanced endoscopy fellow to > 10 years of ERCP experience). Inter-rater reliability, discriminative validity, and internal structure validity were subsequently assessed. Results The BESAT was found to reliably differentiate between endoscopists of varying levels of ERCP experience with experienced ERCPists scoring higher than novice ERCPists in 11 of 13 (85%) instrument items. Inter-rater reliability for BESAT items ranged from good to excellent (intraclass correlation range: 0.86 to 0.93). Internal structure validity was assessed with item-total correlations ranging from 0.53 to 0.83. Conclusions Study findings demonstrate that the BESAT, a video-based ERCP skill assessment tool, has high inter-rater reliability and has discriminative validity in differentiating novice from expert ERCP skill. Further investigations are needed to determine the role of video-based assessment in improving trainee learning curves and patient outcomes.

18.
medRxiv ; 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38405784

RESUMO

Importance: Large language models (LLMs) are crucial for medical tasks. Ensuring their reliability is vital to avoid false results. Our study assesses two state-of-the-art LLMs (ChatGPT and LlaMA-2) for extracting clinical information, focusing on cognitive tests like MMSE and CDR. Objective: Evaluate ChatGPT and LlaMA-2 performance in extracting MMSE and CDR scores, including their associated dates. Methods: Our data consisted of 135,307 clinical notes (Jan 12th, 2010 to May 24th, 2023) mentioning MMSE, CDR, or MoCA. After applying inclusion criteria 34,465 notes remained, of which 765 underwent ChatGPT (GPT-4) and LlaMA-2, and 22 experts reviewed the responses. ChatGPT successfully extracted MMSE and CDR instances with dates from 742 notes. We used 20 notes for fine-tuning and training the reviewers. The remaining 722 were assigned to reviewers, with 309 each assigned to two reviewers simultaneously. Inter-rater-agreement (Fleiss' Kappa), precision, recall, true/false negative rates, and accuracy were calculated. Our study follows TRIPOD reporting guidelines for model validation. Results: For MMSE information extraction, ChatGPT (vs. LlaMA-2) achieved accuracy of 83% (vs. 66.4%), sensitivity of 89.7% (vs. 69.9%), true-negative rates of 96% (vs 60.0%), and precision of 82.7% (vs 62.2%). For CDR the results were lower overall, with accuracy of 87.1% (vs. 74.5%), sensitivity of 84.3% (vs. 39.7%), true-negative rates of 99.8% (98.4%), and precision of 48.3% (vs. 16.1%). We qualitatively evaluated the MMSE errors of ChatGPT and LlaMA-2 on double-reviewed notes. LlaMA-2 errors included 27 cases of total hallucination, 19 cases of reporting other scores instead of MMSE, 25 missed scores, and 23 cases of reporting only the wrong date. In comparison, ChatGPT's errors included only 3 cases of total hallucination, 17 cases of wrong test reported instead of MMSE, and 19 cases of reporting a wrong date. Conclusions: In this diagnostic/prognostic study of ChatGPT and LlaMA-2 for extracting cognitive exam dates and scores from clinical notes, ChatGPT exhibited high accuracy, with better performance compared to LlaMA-2. The use of LLMs could benefit dementia research and clinical care, by identifying eligible patients for treatments initialization or clinical trial enrollments. Rigorous evaluation of LLMs is crucial to understanding their capabilities and limitations.

19.
Arthroplast Today ; 25: 101268, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38235399

RESUMO

Background: This study aims to compare indications, patient characteristics, hospital factors, and complication rates between total hip arthroplasty (THA) patients aged 30 years or younger and those older than 30 years using a large national database. Methods: The Premier Healthcare Database was utilized to identify primary THA patients from 2015 to 2021 who were aged ≤30 or >30 years. Patient demographics, hospital factors, and primary indications were compared for each cohort. Rates of complications and readmissions were assessed for each cohort by primary indication. Differences were assessed through univariate analysis. Results: Overall, 539,173 primary THA patients were identified (age ≤30: 1849; >30: 537,234). Compared to the >30 cohort, the ≤30 cohort was more likely to be male (56.5% vs 44.9%, P < .001) and non-White (34.0% vs 14.2%, P < .001). The most common indications for THA in the ≤30 cohort were osteonecrosis (49.3%), osteoarthritis (17.8%), and congenital hip deformities (16.0%), and in the >30 cohort, they were osteoarthritis (77.0%), other arthritis (11.3%), and osteonecrosis (5.4%). Patients aged ≤30 years had lower rates of respiratory failure (0.16% vs 0.57%, P < .001), acute renal failure (0.32% vs 1.72%, P < .001), and urinary tract infection (0.38% vs 1.11%, P = .003) than those aged >30 years, but higher rates of wound dehiscence (0.59% vs 0.29%, P = .015) and transfusion (3.68% vs 2.21%, P < .001). There were no differences in 90-day readmission rates (P = .811) or 90-day in-hospital death (P = .173) between cohorts. Conclusions: Younger patients undergoing THA differed significantly in indication, patient characteristics, and hospital factors compared to the older population on univariate analysis. Despite differences in indications, the cohorts did not differ markedly with regard to complication rates in this study.

20.
J Arthroplasty ; 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-38220028

RESUMO

BACKGROUND: Postoperative infection is a devastating complication of total joint arthroplasty (TJA). Perioperative use of dexamethasone in patients who have diabetes mellitus (DM) remains controversial due to concern for increased infection risk. This study aimed to evaluate the association between dexamethasone and infection risk among patients who have DM undergoing TJA. METHODS: This was a retrospective cohort study conducted on adult patients who underwent primary, elective total knee arthroplasty (TKA) or total hip arthroplasty (THA) between January 2016 and December 2021 using a large national database. We identified 110,568 TJA patients (TKA: 66.6%; THA: 33.4%), 31.0% (34,298) of which had DM. Patients who received perioperative dexamethasone were compared to those who did not. The primary end points were the 90-day risk of postoperative periprosthetic joint infection, surgical site infection (SSI), and other non-SSI (urinary tract infection, pneumonia, sepsis). RESULTS: When modeling the association between dexamethasone exposure and study outcomes while accounting for the interaction between dexamethasone and morning blood glucose levels, dexamethasone administration conferred no increased odds of postoperative periprosthetic joint infection nor SSI in diabetics. However, dexamethasone significantly lowered the adjusted odds of other postoperative infections in diabetic patients (TKA: adjusted odds ratio = 09, 95% confidence interval = 0.8 to 1.0, P = .030; THA: adjusted odds ratio = 0.7, 95% confidence interval = 0.6 to 0.9, P = .001); specifically in patients with morning blood glucose levels between 110 to 248 mg/dL in TKA and ≤ 172 mg/dL in THA. CONCLUSIONS: This study provides strong evidence against withholding dexamethasone in diabetic patients undergoing TJA based on concern for infection. Instead, short-course perioperative dexamethasone reduced infection risk in select patients. The narrative surrounding dexamethasone should shift away from questions about whether dexamethasone is appropriate for diabetic patients, and instead focus on how best to optimize its use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA