Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Nutr ; 43(1): 284-294, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38104490

RESUMO

BACKGROUND: Athletes vary in hydration status due to ongoing training regimes, diet demands, and extreme exertion. With water being one of the largest body composition compartments, its variation can cause misinterpretation of body composition assessments meant to monitor strength and training progress. In this study, we asked what accessible body composition approach could best quantify body composition in athletes with a variety of hydration levels. METHODS: The Da Kine Study recruited collegiate and intramural athletes to undergo a variety of body composition assessments including air-displacement plethysmography (ADP), deuterium-oxide dilution (D2O), dual-energy X-ray absorptiometry (DXA), underwater-weighing (UWW), 3D-optical (3DO) imaging, and bioelectrical impedance (BIA). Each of these methods generated 2- or 3-compartment body composition estimates of fat mass (FM) and fat-free mass (FFM) and was compared to equivalent measures of the criterion 6-compartment model (6CM) that accounts for variance in hydration. Body composition by each method was used to predict abdominal and thigh strength, assessed by isokinetic/isometric dynamometry. RESULTS: In total, 70 (35 female) athletes with a mean age of 21.8 ± 4.2 years were recruited. Percent hydration (Body Water6CM/FFM6CM) had substantial variation in both males (63-73 %) and females (58-78 %). ADP and DXA FM and FF M had moderate to substantial agreement with the 6C model (Lin's Concordance Coefficient [CCC] = 0.90-0.95) whereas the other measures had lesser agreement (CCC <0.90) with one exception of 3DO FFM in females (CCC = 0.91). All measures of FFM produced excellent precision with %CV < 1.0 %. However, FM measures in general had worse precision (% CV < 2.0 %). Increasing quartiles (significant p < 0.001 trend) of 6CM FFM resulted in increasing strength measures in males and females. Moreover, the stronger the agreement between the alternative methods to the 6CM, the more robust their correlation with strength, irrespective of hydration status. CONCLUSION: The criterion 6CM showed the best association to strength regardless of the hydration status of the athletes for both males and females. Simpler methods showed high precision for both FM and FFM and those with the strongest agreement to the 6CM had the highest strength associations. SUMMARY BOX: This study compared various body composition analysis methods in 70 athletes with varying states of hydration to the criterion 6-compartment model and assessed their relationship to muscle strength. The results showed that accurate and precise estimates of body composition can be determined in athletes, and a more accurate body composition measurement produces better strength estimates. The best laboratory-based techniques were air displacement plethysmography and dual-energy x-ray absorptiometry, while the commercial methods had moderate-poor agreement. Prioritizing accurate body composition assessment ensures better strength estimates in athletes.


Assuntos
Composição Corporal , Água Corporal , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Composição Corporal/fisiologia , Atletas , Absorciometria de Fóton/métodos , Impedância Elétrica , Força Muscular , Reprodutibilidade dos Testes
2.
Clin Nutr ; 43(2): 346-356, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38142479

RESUMO

BACKGROUND & AIMS: The multicompartment approach to body composition modeling provides a more precise quantification of body compartments in healthy and clinical populations. We sought to develop and validate a simplified and accessible multicompartment body composition model using 3-dimensional optical (3DO) imaging and bioelectrical impedance analysis (BIA). METHODS: Samples of adults and collegiate-aged student-athletes were recruited for model calibration. For the criterion multicompartment model (Wang-5C), participants received measures of scale weight, body volume (BV) via air displacement, total body water (TBW) via deuterium dilution, and bone mineral content (BMC) via dual energy x-ray absorptiometry. The candidate model (3DO-5C) used stepwise linear regression to derive surrogate measures of BV using 3DO, TBW using BIA, and BMC using demographics. Test-retest precision of the candidate model was assessed via root mean square error (RMSE). The 3DO-5C model was compared to criterion via mean difference, concordance correlation coefficient (CCC), and Bland-Altman analysis. This model was then validated using a separate dataset of 20 adults. RESULTS: 67 (31 female) participants were used to build the 3DO-5C model. Fat-free mass (FFM) estimates from Wang-5C (60.1 ± 13.4 kg) and 3DO-5C (60.3 ± 13.4 kg) showed no significant mean difference (-0.2 ± 2.0 kg; 95 % limits of agreement [LOA] -4.3 to +3.8) and the CCC was 0.99 with a similar effect in fat mass that reflected the difference in FFM measures. In the validation dataset, the 3DO-5C model showed no significant mean difference (0.0 ± 2.5 kg; 95 % LOA -3.6 to +3.7) for FFM with almost perfect equivalence (CCC = 0.99) compared to the criterion Wang-5C. Test-retest precision (RMSE = 0.73 kg FFM) supports the use of this model for more frequent testing in order to monitor body composition change over time. CONCLUSIONS: Body composition estimates provided by the 3DO-5C model are precise and accurate to criterion methods when correcting for field calibrations. The 3DO-5C approach offers a rapid, cost-effective, and accessible method of body composition assessment that can be used broadly to guide nutrition and exercise recommendations in athletic settings and clinical practice.


Assuntos
Composição Corporal , Densidade Óssea , Adulto , Humanos , Feminino , Idoso , Impedância Elétrica , Absorciometria de Fóton/métodos , Imagem Óptica , Reprodutibilidade dos Testes
4.
Obesity (Silver Spring) ; 30(8): 1589-1598, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35894079

RESUMO

OBJECTIVE: This study examined whether body shape and composition obtained by three-dimensional optical (3DO) scanning improved the prediction of metabolic syndrome (MetS) prevalence compared with BMI and demographics. METHODS: A diverse ambulatory adult population underwent whole-body 3DO scanning, blood tests, manual anthropometrics, and blood pressure assessment in the Shape Up! Adults study. MetS prevalence was evaluated based on 2005 National Cholesterol Education Program criteria, and prediction of MetS involved logistic regression to assess (1) BMI, (2) demographics-adjusted BMI, (3) 85 3DO anthropometry and body composition measures, and (4) BMI + 3DO + demographics models. Receiver operating characteristic area under the curve (AUC) values were generated for each predictive model. RESULTS: A total of 501 participants (280 female) were recruited, with 87 meeting the criteria for MetS. Compared with the BMI model (AUC = 0.819), inclusion of age, sex, and race increased the AUC to 0.861, and inclusion of 3DO measures further increased the AUC to 0.917. The overall integrated discrimination improvement between the 3DO + demographics and the BMI model was 0.290 (p < 0.0001) with a net reclassification improvement of 0.214 (p < 0.0001). CONCLUSIONS: Body shape measures from an accessible 3DO scan, adjusted for demographics, predicted MetS better than demographics and/or BMI alone. Risk classification in this population increased by 29% when using 3DO scanning.


Assuntos
Síndrome Metabólica , Somatotipos , Adulto , Antropometria/métodos , Composição Corporal/fisiologia , Índice de Massa Corporal , Feminino , Humanos , Síndrome Metabólica/diagnóstico por imagem , Síndrome Metabólica/epidemiologia , Curva ROC , Fatores de Risco , Circunferência da Cintura
5.
Am J Clin Nutr ; 116(5): 1418-1429, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35883219

RESUMO

BACKGROUND: Novel advancements in wearable technologies include continuous measurement of body composition via smart watches. The accuracy and stability of these devices are unknown. OBJECTIVES: This study evaluated smart watches with integrated bioelectrical impedance analysis (BIA) sensors for their ability to measure and monitor changes in body composition. METHODS: Participants recruited across BMIs received duplicate body composition measures using 2 wearable bioelectrical impedance analysis (W-BIA) model smart watches in sitting and standing positions, and multiple versions of each watch were used to evaluate inter- and intramodel precision. Duplicate laboratory-grade octapolar bioelectrical impedance analysis (8-BIA) and criterion DXA scans were acquired to compare estimates between the watches and laboratory methods. Test-retest precision and least significant changes assessed the ability to monitor changes in body composition. RESULTS: Of 109 participants recruited, 75 subjects completed the full manufacturer-recommended protocol. No significant differences were observed between W-BIA watches in position or between watch models. Significant fat-free mass (FFM) differences (P < 0.05) were observed between both W-BIA and 8-BIA when compared to DXA, though the systematic biases to the criterion were correctable. No significant difference was observed between the W-BIA and the laboratory-grade BIA technology for FFM (55.3 ± 14.5 kg for W-BIA versus 56.0 ± 13.8 kg for 8-BIA; P > 0.05; Lin's concordance correlation coefficient = 0.97). FFM was less precise on the watches than DXA {CV, 0.7% [root mean square error (RMSE) = 0.4 kg] versus 1.3% (RMSE = 0.7 kg) for W-BIA}, requiring more repeat measures to equal the same confidence in body composition changes over time as DXA. CONCLUSIONS: After systematic correction, smart-watch BIA devices are capable of stable, reliable, and accurate body composition measurements, with precision comparable to but lower than that of laboratory measures. These devices allow for measurement in environments not accessible to laboratory systems, such as homes, training centers, and geographically remote locations.


Assuntos
Composição Corporal , Humanos , Impedância Elétrica , Reprodutibilidade dos Testes , Índice de Massa Corporal , Absorciometria de Fóton
6.
Clin Nutr ; 41(1): 211-218, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34915272

RESUMO

BACKGROUND: The accurate assessment of total body and regional body circumferences, volumes, and compositions are critical to monitor physical activity and dietary interventions, as well as accurate disease classifications including obesity, metabolic syndrome, sarcopenia, and lymphedema. We assessed body composition and anthropometry estimates provided by a commercial 3-dimensional optical (3DO) imaging system compared to criterion measures. METHODS: Participants of the Shape Up! Adults study were recruited for similar sized stratifications by sex, age (18-40, 40-60, >60 years), BMI (under, normal, overweight, obese), and across five ethnicities (non-Hispanic [NH] Black, NH White, Hispanic, Asian, Native Hawaiian/Pacific Islander). All participants received manual anthropometry assessments, duplicate whole-body 3DO (Styku S100), and dual-energy X-ray absorptiometry (DXA) scans. 3DO estimates provided by the manufacturer for anthropometry and body composition were compared to the criterion measures using concordance correlation coefficient (CCC) and Bland-Altman analysis. Test-retest precision was assessed by root mean square error (RMSE) and coefficient of variation. RESULTS: A total of 188 (102 female) participants were included. The overall fat free mass (FFM) as measured by DXA (54.1 ± 15.2 kg) and 3DO (55.3 ± 15.0 kg) showed a small mean difference of 1.2 ± 3.4 kg (95% limits of agreement -7.0 to +5.6) and the CCC was 0.97 (95% CI: 0.96-0.98). The CCC for FM was 0.95 (95% CI: 0.94-0.97) and the mean difference of 1.3 ± 3.4 kg (95% CI: -5.5 to +8.1) reflected the difference in FFM measures. 3DO anthropometry and body composition measurements showed high test-retest precision for whole body volume (1.1 L), fat mass (0.41 kg), percent fat (0.60%), arm and leg volumes, (0.11 and 0.21 L, respectively), and waist and hip circumferences (all <0.60 cm). No group differences were observed when stratified by body mass index, sex, or race/ethnicity. CONCLUSIONS: The anthropometric and body composition estimates provided by the 3DO scanner are precise and accurate to criterion methods if offsets are considered. This method offers a rapid, broadly available, and automated method of body composition assessment regardless of body size. Further studies are recommended to examine the relationship between measurements obtained by 3DO scans and metabolic health in healthy and clinical populations.


Assuntos
Antropometria/instrumentação , Composição Corporal , Imageamento Tridimensional/instrumentação , Imagem Corporal Total/instrumentação , Absorciometria de Fóton , Adolescente , Adulto , Antropometria/métodos , Índice de Massa Corporal , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Imagem Corporal Total/métodos , Adulto Jovem
7.
JAMA Intern Med ; 180(11): 1491-1499, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32986097

RESUMO

Importance: The efficacy and safety of time-restricted eating have not been explored in large randomized clinical trials. Objective: To determine the effect of 16:8-hour time-restricted eating on weight loss and metabolic risk markers. Interventions: Participants were randomized such that the consistent meal timing (CMT) group was instructed to eat 3 structured meals per day, and the time-restricted eating (TRE) group was instructed to eat ad libitum from 12:00 pm until 8:00 pm and completely abstain from caloric intake from 8:00 pm until 12:00 pm the following day. Design, Setting, and Participants: This 12-week randomized clinical trial including men and women aged 18 to 64 years with a body mass index (BMI, calculated as weight in kilograms divided by height in meters squared) of 27 to 43 was conducted on a custom mobile study application. Participants received a Bluetooth scale. Participants lived anywhere in the United States, with a subset of 50 participants living near San Francisco, California, who underwent in-person testing. Main Outcomes and Measures: The primary outcome was weight loss. Secondary outcomes from the in-person cohort included changes in weight, fat mass, lean mass, fasting insulin, fasting glucose, hemoglobin A1c levels, estimated energy intake, total energy expenditure, and resting energy expenditure. Results: Overall, 116 participants (mean [SD] age, 46.5 [10.5] years; 70 [60.3%] men) were included in the study. There was a significant decrease in weight in the TRE (-0.94 kg; 95% CI, -1.68 to -0.20; P = .01), but no significant change in the CMT group (-0.68 kg; 95% CI, -1.41 to 0.05, P = .07) or between groups (-0.26 kg; 95% CI, -1.30 to 0.78; P = .63). In the in-person cohort (n = 25 TRE, n = 25 CMT), there was a significant within-group decrease in weight in the TRE group (-1.70 kg; 95% CI, -2.56 to -0.83; P < .001). There was also a significant difference in appendicular lean mass index between groups (-0.16 kg/m2; 95% CI, -0.27 to -0.05; P = .005). There were no significant changes in any of the other secondary outcomes within or between groups. There were no differences in estimated energy intake between groups. Conclusions and Relevance: Time-restricted eating, in the absence of other interventions, is not more effective in weight loss than eating throughout the day. Trial Registration: ClinicalTrials.gov Identifiers: NCT03393195 and NCT03637855.


Assuntos
Restrição Calórica/métodos , Dietoterapia/métodos , Jejum/fisiologia , Obesidade/dietoterapia , Obesidade/metabolismo , Adulto , Glicemia/metabolismo , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/terapia , Cooperação do Paciente , Redução de Peso , Adulto Jovem
8.
Curr Dev Nutr ; 4(6): nzaa090, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33959689

RESUMO

BACKGROUND: Visceral adiposity, more so than overall adiposity, is associated with chronic disease and mortality. There has been, to our knowledge, little research exploring the association between diet quality and visceral adipose tissue (VAT) among a mulitethnic population aged 18-80 y. OBJECTIVE: The primary objective of this cross-sectional analysis was to examine the association between diet quality [Healthy Eating Index-2010 (HEI-2010) scores] and VAT among a multiethnic population of young, middle, and older aged adults in the United States. Secondary objectives were to repeat these analyses with overall adiposity and blood-based biomarkers for type 2 diabetes and cardiovascular disease risk as outcome measures. METHODS: A total of 540 adults (dropped out: n = 4; age: 18-40 y, n = 220; 40-60 y, n = 183; 60-80 y, n = 133) were recruited across 3 sites (Honolulu County, San Francisco, and Baton Rouge) for the Shape Up! Adults study. Whole-body DXA, anthropometry, fasting blood draw, and questionnaires (food frequency, physical activity, and demographic characteristics) were completed. Linear regression was used to assess the associations between HEI-2010 tertiles and VAT and secondary outcome measures among all participants and age-specific strata, while adjusting for known confounders. RESULTS: VAT, BMI (kg/m2), body fat percentage, total body fat, trunk fat, insulin, and insulin resistance were inversely related to diet quality (all P values < 0.004). When stratified by age, diet quality was inversely associated with VAT among participants aged 60-80 y (P < 0.006) and VAT/subcutaneous adipose tissue (SAT) among participants aged 40-60 y (P < 0.008). CONCLUSIONS: Higher-quality diet was associated with lower VAT, overall adiposity, and insulin resistance among this multiethnic population of young, middle, and older aged adults with ages ranging from 18 to 80 y. More specifically, adherence to a high-quality diet may minimize VAT accumulation in adults aged 60-80 y and preferentially promote storage of SAT compared with VAT in adults aged 40-60 y.This study was registered at clinicaltrials.gov as NCT03637855.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA