Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Opt Express ; 30(2): 3138-3147, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35209439

RESUMO

Multiphoton contributions pose a significant challenge for the realisation of heralded single-photon sources (HSPS) based on nonlinear processes. In this work, we improve the quality of single photons generated in this way by harnessing the photon-number resolving (PNR) capabilities of commercial superconducting nanowire single-photon detectors (SNSPDs). We report a 13 ± 0.4% reduction of g(2)(τ = 0), even with a collection efficiency in the photon source of only 29.6%. Our work demonstrates the first application of the PNR capabilities of SNSPDs and shows improvement in the quality of an HSPS with widely available technology.

2.
Opt Lett ; 46(11): 2565-2568, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34061057

RESUMO

The discrimination of coherent states is a key task in optical communication and quantum key distribution protocols. In this work, we use a photon-number-resolving detector, the transition-edge sensor, to discriminate binary-phase-shifted coherent states at a telecom wavelength. Owing to its dynamic range and high efficiency, we achieve a bit error probability that unconditionally exceeds the standard quantum limit (SQL) by up to 7.7 dB. The improvement to the SQL persists for signals containing up to approximately seven photons on average and is achieved in a single shot (i.e., without measurement feedback), thus making our approach compatible with larger bandwidths.

3.
J Cardiovasc Surg (Torino) ; 53(5): 595-604, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22955554

RESUMO

Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Projetos de Pesquisa , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Ann Vasc Surg ; 15(6): 601-7, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11769139

RESUMO

The objective of this report was to analyze the current surgical results of operative treatment in patients suffering ruptured AAA (abdominal aortic aneurysms) and to define those independent predictive factors for mortality. During a period of 2 years, from January 1996 to December 1997, 144 patients operated on for ruptured AAA in 10 hospitals were included in a multicenter retrospective study. Among the collected variables concerning each patient, those with potential relation to surgical mortality were studied: gender, age, diabetes, hypertension, cardiopathy, pulmonary obstructive disease, preoperative renal dysfunction, symptomatic cerebrovascular disease, peripheral vascular disease, hematocrit on admission, preoperative hypotension < 80 mmHg, loss of consciousness, cardiac arrest, aortic aneurysm location (infrarenal versus non-infrarenal), iliac involvement, aneurysm size, type of rupture, left renal vein ligature, ligature of a patent inferior mesenteric artery, place of aortic cross-clamping, type of grafting, exclusion of both hypogastric arteries, venous technical complications, associated surgery, use of cell saver, intraoperative blood loss, and postoperative complications (renal failure, sepsis, coagulopathy, cardiac complications, pulmonary complications, colon ischemia, prosthetic graft complications, and need for reoperation). Those variables with statistical significance in the univariate analysis were introduced into a multivariate logistic regression model to determine the independent predictors of death. From our results we concluded that surgery for ruptured abdominal aortic aneurysms continues to have an excessively high mortality rate. Even though some preoperative variables could be identified as predictors of mortality, an absolute mortality risk has not yet been determined and the decision to negate surgery should be individualized rather than taken on that basis only. Early diagnosis and treatment of symptomatic aneurysms would improve mortality figures and selective screening should be contemplated.


Assuntos
Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/complicações , Ruptura Aórtica/mortalidade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Pressão Sanguínea/fisiologia , Creatinina/sangue , Feminino , Hematócrito , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Fatores de Risco , Instrumentos Cirúrgicos , Análise de Sobrevida , Resultado do Tratamento
6.
Angiologia ; 42(6): 205-9, 1990.
Artigo em Espanhol | MEDLINE | ID: mdl-2150163

RESUMO

During the last years diverse types of Dacron prosthesis without porosity (because to be impregnated by different materials) have appeared. In the presented study, outcomes from three different types of prosthesis (differentiated by the impregnated material) were evaluated and a comparison with classical prosthesis was made.


Assuntos
Aorta Abdominal , Prótese Vascular , Artéria Femoral , Seguimentos , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Polietilenotereftalatos , Porosidade , Complicações Pós-Operatórias , Trombose
7.
Angiologia ; 42(4): 138-47, 1990.
Artigo em Espanhol | MEDLINE | ID: mdl-2248421

RESUMO

The authors present their experience with Morphologic Capillaroscopy, and analyze the diagnostic dates provided by this technique to the current Angiology and Vascular Surgery protocols. Morphologic anomalies founded during diverse systemic diseases as well as the changes on the capillary field produced in cases of chronic ischaemia and venous insufficiency were analysed. The study was made on the basis of 236 capillaroscopic images and it was completed by an extensive bibliographic review of the subject.


Assuntos
Capilares/patologia , Microscopia/instrumentação , Doenças Vasculares/diagnóstico , Humanos , Doenças Vasculares/fisiopatologia
8.
Angiologia ; 41(1): 1-3, 1989.
Artigo em Espanhol | MEDLINE | ID: mdl-2712395

RESUMO

The experience about 18 patients subjected to aortoiliac surgery is exposed. The cardiac flow was bloodless monitorized by means of an apparatus, based in Doppler effect, which proved its accuracy and usefulness. Authors considers necessary to monitorize the cardiac flow in this sort of surgery, and this bloodless method has showed its validity and simplicity.


Assuntos
Aorta Abdominal/cirurgia , Débito Cardíaco , Ecocardiografia Doppler , Artéria Ilíaca/cirurgia , Idoso , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA