Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Taiwan J Obstet Gynecol ; 63(5): 745-749, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39266158

RESUMO

OBJECTIVE: This case demonstrated the possibility of using GATA3-positive circulating tumor cells (CTCs) to detect early-stage breast cancer (BrC). CASE REPORT: The 86 years old female patient received a mammographic examination with no evidence of malignancy (Breast Imaging Reporting and Data System, (BI-RADS category 2). However, CTC testing on the same day revealed four GATA3-positive CTCs in 4 ml of peripheral blood. Core needle biopsy was performed in the suspicious area even with no evidence of malignant image on breast ultrasound. Pathologic examination showed invasive carcinoma of no special type of the breast. The patient then received an oncoplastic partial mastectomy of right breast and sentinel lymph node biopsy. The surgical staging was cT1N0M0. Post-operation follow-up examination showed absence of GATA3-positive CTCs and the presence of HER2/ER positive CTCs. CONCLUSION: The role of GATA3-positive CTCs as a potential biomarker for early-stage BrC should be explored.


Assuntos
Neoplasias da Mama , Fator de Transcrição GATA3 , Estadiamento de Neoplasias , Células Neoplásicas Circulantes , Humanos , Feminino , Fator de Transcrição GATA3/análise , Fator de Transcrição GATA3/metabolismo , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/sangue , Células Neoplásicas Circulantes/patologia , Células Neoplásicas Circulantes/metabolismo , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Biópsia de Linfonodo Sentinela , Biópsia com Agulha de Grande Calibre , Mastectomia Segmentar , Detecção Precoce de Câncer/métodos
2.
Int J Mol Sci ; 24(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36674508

RESUMO

The purpose of the present review is to try to highlight recent advances in the application of microfluidic technology on non-invasive prenatal diagnosis (NIPD). The immunoaffinity based microfluidic technology is the most common approach for NIPD, followed by size-based microfluidic methods. Immunoaffinity microfluidic methods can enrich and isolate circulating fetal extravillous trophoblasts (fEVTs) or fetal nucleated red blood cells (fnRBCs) for NIPD by using specific antibodies, but size-based microfluidic systems are only applied to isolate fEVTs. Most studies based on the immunoaffinity microfluidic system gave good results. Enough fetal cells were obtained for chromosomal and/or genetic analysis in all blood samples. However, the results from studies using size-based microfluidic systems for NIPD are less than ideal. In conclusion, recent advances in microfluidic devices make the immunoaffinity based microfluidic system potentially a powerful tool for cell-based NIPD. However, more clinical validation is needed.


Assuntos
Microfluídica , Diagnóstico Pré-Natal , Gravidez , Feminino , Humanos , Diagnóstico Pré-Natal/métodos , Feto , Dispositivos Lab-On-A-Chip , Anticorpos
3.
Int J Mol Sci ; 23(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36499466

RESUMO

Single-cell sequencing provides promising information in tumor evolution and heterogeneity. Even with the recent advances in circulating tumor cell (CTC) technologies, it remains a big challenge to precisely and effectively isolate CTCs for downstream analysis. The Cell RevealTM system integrates an automatic CTC enrichment and staining machine, an AI-assisted automatic CTC scanning and identification system, and an automatic cell picking machine for CTC isolation. H1975 cell line was used for the spiking test. The identification of CTCs and the isolation of target CTCs for genetic sequencing were performed from the peripheral blood of three cancer patients, including two with lung cancer and one with both lung cancer and thyroid cancer. The spiking test revealed a mean recovery rate of 81.81% even with extremely low spiking cell counts with a linear relationship between the spiked cell counts and the recovered cell counts (Y = 0.7241 × X + 19.76, R2 = 0.9984). The three cancer patients had significantly higher TTF-1+ CTCs than healthy volunteers. All target CTCs were successfully isolated by the Cell Picker machine for a subsequent genetic analysis. Six tumor-associated mutations in four genes were detected. The present study reveals the Cell RevealTM platform can precisely identify and isolate target CTCs and then successfully perform single-cell sequencing by using commercially available genetic devices.


Assuntos
Neoplasias Pulmonares , Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patologia , Separação Celular , Linhagem Celular Tumoral , Dispositivos Lab-On-A-Chip , Neoplasias Pulmonares/genética
4.
ACS Appl Mater Interfaces ; 14(48): 54090-54100, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36420750

RESUMO

Chiral halide perovskites have attracted considerable attention because of their chiroptical, second-harmonic generation, and ferroelectricity properties and their potential application in chiroptoelectronics and chiral spintronics. However, the fundamental research of these properties is insufficient. In this work, chiral perovskites were synthesized using precursor solutions with various stoichiometric ratios ⟨n⟩. The chiral perovskite film prepared from the solution with ⟨n⟩ = 1 is composed of (R-/S-/rac-MBA)2PbBr4, whereas the films prepared from the solutions with ⟨n⟩ larger than 1 are a mixture of (R-/S-/rac-MBA)2(CsMA)n-1PbnBr3n+1 with n = 1 and large n values. A photoluminescence quantum yield of approximately 90 was obtained. Symmetric circular dichroism (CD) spectra were observed without an external magnetic field. Under various magnetic fields, magnetic field-induced CD features are superimposed with the intrinsic chirality-induced CD features. For the ⟨n⟩ = 1 chiral perovskite film, the energy level splitting induced by chiral molecules are a few 10 µeV, whereas the energy level splitting induced by magnetic fields are at the range of ∼-250 to ∼250 µeV. Circularly polarized photoluminescence spectra were observed at room temperature and associated with the spin-preserved energy funneling from highly energetic phases to the lower energetic phases.

5.
Micromachines (Basel) ; 12(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919456

RESUMO

Circulating tumor cell (CTC) test is currently used as a biomarker in cancer treatment. Unfortunately, the poor reproducibility and limited sensitivity with the CTC detection have limited its potential impact on clinical application. A reliable automated CTC detection system is therefore needed. We have designed an automated microfluidic chip-based CTC detection system and hypothesize this novel system can reliably detect CTC from clinical specimens. SKOV3 ovarian cancer cell line was used first to test the reliability of our system. Ten healthy volunteers, 5 patients with benign ovarian tumors, and 8 patients with epithelial ovarian cancer (EOC) were recruited to validate the CTC capturing efficacy in the peripheral blood. The capture rates for spiking test in SKOV3 cells were 48.3% and 89.6% by using anti-EpCAM antibody alone and a combination of anti-EpCAM antibody and anti-N-cadherin antibody, respectively. The system was sensitive to detection of low cell count and showed a linear relationship with the cell counts in our test range. The sensitivity and specificity were 62.5% and 100% when CTC was used as a biomarker for EOC. Our results demonstrated that this automatic CTC platform has a high capture rate and is feasible for detection of CTCs in EOC.

6.
RSC Adv ; 10(61): 37161-37167, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-35521228

RESUMO

Organometal halide perovskites are attracting a great deal of attention because of their long carrier diffusion lengths, wide wavelength tunability, and narrow-band emission. However, the toxicity of lead has caused considerable environmental and health concerns. In this work, lead-free cesium tin halide nanocrystals are synthesized and investigated. CsSnBr3 and CsSnI3 nanocrystals, 25 and 7 nm in size, are synthesized by a facile hot injection method. Absorption spectroscopy, photoluminescence spectroscopy, and X-ray diffraction were used to understand their structural and optical properties. CsSnBr3 and CsSnI3 nanocrystals show emission peaks at 683 and 938 nm, respectively. These nanocrystals show shelf stability for a few months. Temperature-dependent photoluminescence is utilized to know more about fundamental physical parameters, such as exciton binding energy, charge carrier-phonon interactions and band gap. Light-emitting diodes and color down-conversion films are also demonstrated using these lead free perovskite nanocrystals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA