Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(11)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38004987

RESUMO

In this theoretical study, we explore the enhancement of sensing capabilities in surface acoustic wave (SAW)-based magnetic field sensors through the integration of engineered phononic crystals (PnCs). We particularly focus on amplifying the interaction between the SAW and magnetostrictive materials within the PnC structure. Through comprehensive simulations, we demonstrate the synchronization between the SAWs generated by IDTs and the resonant modes of PnCs, thereby leading to an enhancement in sensitivity. Furthermore, we investigate the ΔE effect, highlighting the sensor's responsiveness to changes in external magnetic fields, and quantify its magnetic sensitivity through observable changes in the SAW phase velocity leading to phase shifts at the end of the delay line. Notably, our approach yields a magnetic field sensitivity of approximately S~138 °mT for a delay line length of only 77 µm in homogeneous magnetic fields. Our findings underline the potential of PnCs to advance magnetic field sensing. This research offers insights into the integration of engineered materials for improved sensor performance, paving the way for more effective and accurate magnetic field detection solutions.

2.
Sensors (Basel) ; 23(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37420715

RESUMO

The intricate interdependency of device design and fabrication process complicates the development of microelectromechanical systems (MEMS). Commercial pressure has motivated industry to implement various tools and methods to overcome challenges and facilitate volume production. By now, these are only hesitantly being picked up and implemented in academic research. In this perspective, the applicability of these methods to research-focused MEMS development is investigated. It is found that even in the dynamics of a research endeavor, it is beneficial to adapt and apply tools and methods deduced from volume production. The key step is to change the perspective from fabricating devices to developing, maintaining and advancing the fabrication process. Tools and methods are introduced and discussed, using the development of magnetoelectric MEMS sensors within a collaborative research project as an illustrative example. This perspective provides both guidance to newcomers as well as inspiration to the well-versed experts.


Assuntos
Sistemas Microeletromecânicos , Pesquisa
3.
Sensors (Basel) ; 23(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36772134

RESUMO

This work presents an approach for the estimation of the adsorbed mass of 1,5-diaminopentane (cadaverine) on a functionalized piezoelectrically driven microcantilever (PD-MC) sensor, using a polynomial developed from the characterization of the resonance frequency response to the known added mass. This work supplements the previous studies we carried out on the development of an electronic nose for the measurement of cadaverine in meat and fish, as a determinant of its freshness. An analytical transverse vibration analysis of a chosen microcantilever beam with given dimensions and desired resonance frequency (>10 kHz) was conducted. Since the beam is considered stepped with both geometrical and material non-uniformity, a modal solution for stepped beams, extendable to clamped-free beams of any shape and structure, is derived and used for free and forced vibration analyses of the beam. The forced vibration analysis is then used for transformation to an equivalent electrical model, to address the fact that the microcantilever is both electronically actuated and read. An analytical resonance frequency response to the mass added is obtained by adding simulated masses to the free end of the beam. Experimental verification of the resonance frequency response is carried out, by applying known masses to the microcantilever while measuring the resonance frequency response using an impedance analyzer. The obtained response is then transformed into a resonance frequency to the added mass response polynomial using a polynomial fit. The resulting polynomial is then verified for performance using different masses of cantilever functionalization solution. The functionalized cantilever is then exposed to different concentrations of cadaverine while measuring the resonance frequency and mass of cadaverine adsorbed estimated using the previously obtained polynomial. The result is that there is the possibility of using this approach to estimate the mass of cadaverine gas adsorbed on a functionalized microcantilever, but the effectiveness of this approach is highly dependent on the known masses used for the development of the response polynomial model.

4.
Micromachines (Basel) ; 13(8)2022 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-36014204

RESUMO

Ferroelectric thin films of wurtzite-type aluminum scandium nitride (Al1−xScxN) are promising candidates for non-volatile memory applications and high-temperature sensors due to their outstanding functional and thermal stability exceeding most other ferroelectric thin film materials. In this work, the thermal expansion along with the temperature stability and its interrelated effects have been investigated for Al1−xScxN thin films on sapphire Al2O3(0001) with Sc concentrations x (x = 0, 0.09, 0.23, 0.32, 0.40) using in situ X-ray diffraction analyses up to 1100 °C. The selected Al1−xScxN thin films were grown with epitaxial and fiber textured microstructures of high crystal quality, dependent on the choice of growth template, e.g., epitaxial on Al2O3(0001) and fiber texture on Mo(110)/AlN(0001)/Si(100). The presented studies expose an anomalous regime of thermal expansion at high temperatures >~600 °C, which is described as an isotropic expansion of a and c lattice parameters during annealing. The collected high-temperature data suggest differentiation of the observed thermal expansion behavior into defect-coupled intrinsic and oxygen-impurity-coupled extrinsic contributions. In our hypothesis, intrinsic effects are denoted to the thermal activation, migration and curing of defect structures in the material, whereas extrinsic effects describe the interaction of available oxygen species with these activated defect structures. Their interaction is the dominant process at high temperatures >800 °C resulting in the stabilization of larger modifications of the unit cell parameters than under exclusion of oxygen. The described phenomena are relevant for manufacturing and operation of new Al1−xScxN-based devices, e.g., in the fields of high-temperature resistant memory or power electronic applications.

5.
Micromachines (Basel) ; 13(5)2022 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-35630209

RESUMO

Monolithic integration of permanent micromagnets into MEMS structures offers many advantages in magnetic MEMS applications. A novel technique called PowderMEMS, based on the agglomeration of micron-sized powders by atomic layer deposition (ALD), has been used to fabricate permanent micromagnets on 8-inch wafers. In this paper, we report the fabrication and magnetic characterization of PowderMEMS micromagnets prepared from two different NdFeB powder particle sizes. A remanence of 423 mT and intrinsic coercivity of 924 mT is achieved at the low ALD process temperature of 75 °C, making this process compatible with MEMS technology. The magnetic reversible mechanism in the micromagnets is discussed with the help of the Wohlfarth equation. To ensure the operability of such integrated micromagnets in different application environments, we conducted a set of experiments to systematically investigate the thermal and corrosive stability. NdFeB micromagnets with larger powder particle size (d50 = 25 µm) exhibit high thermal stability in air. Furthermore, the corrosion stability of the micromagnets is significantly improved by an additional silicon oxide passivation layer deposited by plasma-enhanced chemical vapor deposition (PECVD). The presented results demonstrate the durability of PowderMEMS micromagnets, enabling their application in various fields, e.g., microfluidics, sensors, actuators, and microelectronics.

6.
Micromachines (Basel) ; 13(5)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35630250

RESUMO

In this work, we present a method for growing highly c-axis oriented aluminum scandium nitride (AlScN) thin films on (100) silicon (Si), silicon dioxide (SiO2) and epitaxial polysilicon (poly-Si) substrates using a substrate independent approach. The presented method offers great advantages in applications such as piezoelectric thin-film-based surface acoustic wave devices where a metallic seed layer cannot be used. The approach relies on a thin AlN layer to establish a wurtzite nucleation layer for the growth of w-AlScN films. Both AlScN thin film and seed layer AlN are prepared by DC reactive magnetron sputtering process where a Sc concentration of 27% is used throughout this study. The crystal quality of (0002) orientation of Al0.73Sc0.27N films on all three substrates is significantly improved by introducing a 20 nm AlN seed layer. Although AlN has a smaller capacitance than AlScN, limiting the charge stored on the electrode plates, the combined piezoelectric coefficient d33,f with 500 nm AlScN is only slightly reduced by about 4.5% in the presence of the seed layer.

7.
Sensors (Basel) ; 21(24)2021 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-34960260

RESUMO

In this work, the first surface acoustic-wave-based magnetic field sensor using thin-film AlScN as piezoelectric material deposited on a silicon substrate is presented. The fabrication is based on standard semiconductor technology. The acoustically active area consists of an AlScN layer that can be excited with interdigital transducers, a smoothing SiO2 layer, and a magnetostrictive FeCoSiB film. The detection limit of this sensor is 2.4 nT/Hz at 10 Hz and 72 pT/Hz at 10 kHz at an input power of 20 dBm. The dynamic range was found to span from about ±1.7 mT to the corresponding limit of detection, leading to an interval of about 8 orders of magnitude. Fabrication, achieved sensitivity, and noise floor of the sensors are presented.

8.
Sensors (Basel) ; 21(18)2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34577249

RESUMO

Micro-cantilever sensors are a known reliable tool for gas sensing in industrial applications. We have demonstrated the application of cantilever sensors on the detection of a meat freshness volatile biomarker (cadaverine), for determination of meat and fish precise expiration dates. For achieving correct target selectivity, the cantilevers need to be functionalized with a cadaverine-selective binder, based on a cyclam-derivative. Cantilever surface properties such as surface energy strongly influence the binder morphology and material clustering and, therefore, target binding. In this paper, we explore how chemical and physical surface treatments influence cantilever surface, binder morphology/clustering and binding capabilities. Sensor measurements with non-controlled surface properties are presented, followed by investigations on the binder morphology versus surface energy and cadaverine capture. We demonstrated a method for hindering binder crystallization on functionalized surfaces, leading to reproducible target capture. The results show that cantilever surface treatment is a promising method for achieving a high degree of functionalization reproducibility for industrial cantilever sensors, by controlling binder morphology and uniformity.


Assuntos
Técnicas Biossensoriais , Animais , Reprodutibilidade dos Testes , Propriedades de Superfície
9.
IEEE Trans Biomed Circuits Syst ; 14(5): 971-984, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32746340

RESUMO

Magnetomyography (MMG) with superconducting quantum interference devices (SQUIDs) enabled the measurement of very weak magnetic fields (femto to pico Tesla) generated from the human skeletal muscles during contraction. However, SQUIDs are bulky, costly, and require working in a temperature-controlled environment, limiting wide-spread clinical use. We introduce a low-profile magnetoelectric (ME) sensor with analog frontend circuitry that has sensitivity to measure pico-Tesla MMG signals at room temperature. It comprises magnetostrictive and piezoelectric materials, FeCoSiB/AlN. Accurate device modelling and simulation are presented to predict device fabrication process comprehensively using the finite element method (FEM) in COMSOL Multiphysics. The fabricated ME chip with its readout circuit was characterized under a dynamic geomagnetic field cancellation technique. The ME sensor experiment validate a very linear response with high sensitivities of up to 378 V/T driven at a resonance frequency of fres = 7.76 kHz. Measurements show the sensor limit of detections of down to 175 pT/√Hz at resonance, which is in the range of MMG signals. Such a small-scale sensor has the potential to monitor chronic movement disorders and improve the end-user acceptance of human-machine interfaces.


Assuntos
Campos Magnéticos , Músculo Esquelético , Simulação por Computador , Humanos
10.
Opt Express ; 27(6): 9097-9098, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-31052719

RESUMO

Erroneous absolute luminance values of the pixelated phosphor structure B25 (pixel size of 25 microns by 25 microns) have been corrected. The updated figure shows clearly the potential of the investigated structure as light-converter for high-resolution lighting systems.

11.
Opt Express ; 26(20): 26134-26144, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469704

RESUMO

Porous phosphor microstructures are studied for their potential as light converter in laser-based, high-resolution lighting systems. Phosphor particles are filled into pre-patterned silicon molds and coated by an atomic layer deposition with a thin layer of Al2O3 for mechanical stability. Pixel sizes of 2 mm by 2 mm down to 25 µm by 25 µm are fabricated. The structures show a significant drop in luminance between the illuminated and the non-illuminated, adjacent pixel. The high thermal conductivity of the silicon allows an efficient cooling of the structures. Having removed the backside silicon, an active air flow cooling of the porous phosphor structure is possible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA