Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 455: 139740, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38843715

RESUMO

Monascus species are functional fermentation fungi with great potential for selenium (Se) supplementation. This study investigated the effects of Se bio-fortification on the growth, morphology, and biosynthesis of Monascus ruber M7. The results demonstrated a significant increase in the yield of orange and red Monascus pigments (MPs) in red yeast rice (RYR) by 38.52% and 36.57%, respectively, under 20 µg/mL of selenite pressure. Meanwhile, the production of citrinin (CIT), a mycotoxin, decreased from 244.47 µg/g to 175.01 µg/g. Transcriptome analysis revealed significant upregulation of twelve genes involved in MPs biosynthesis, specifically MpigE, MpigF, and MpigN, and downregulation of four genes (mrr3, mrr4, mrr7, and mrr8) associated with CIT biosynthesis. Additionally, three genes encoding cysteine synthase cysK (Log2FC = 1.6), methionine synthase metH (Log2FC = 2.2), and methionyl-tRNA synthetase metG (Log2FC = 1.8) in selenocompound metabolism showed significantly upregulated. These findings provide insights into Se biotransformation and metabolism in filamentous fungi.

2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 184-191, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605619

RESUMO

More than 70% of tumor patients require radiotherapy. Medical electron linear accelerators are important high-end radiotherapy equipment for tumor radiotherapy. With the application of artificial intelligence technology in medical electron linear accelerator, radiotherapy has evolved from ordinary radiotherapy to today's intelligent radiotherapy. This study introduces the development history, working principles and system composition of medical electron linear accelerators. It outlines the key technologies for improving the performance of medical linear electron accelerators, including beam control, multi-leaf collimator, guiding technology and dose evaluation. It also looks forward to the development trend of major radiotherapy technologies, such as biological guided radiotherapy, FLASH radiotherapy and intelligent radiotherapy, which provides references for the development of medical electron linear accelerators.


Assuntos
Elétrons , Neoplasias , Humanos , Inteligência Artificial , Aceleradores de Partículas , Dosagem Radioterapêutica
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(4): 360-364, 2023 Jul 30.
Artigo em Chinês | MEDLINE | ID: mdl-37580283

RESUMO

Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.


Assuntos
Neoplasias , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Imagens de Fantasmas , Radiometria/métodos
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(4): 377-382, 2023 Jul 30.
Artigo em Chinês | MEDLINE | ID: mdl-37580286

RESUMO

Dynamic multi-leaf collimator, which has the function of radiation beam shaping, is a key executive component of tumor precise radiotherapy, and plays a core role in improving the accuracy, efficiency and quality of radiotherapy. A new type of collimator leaf end structure with circular arc and plane combination was studied, and collimator penumbra performance analysis model combining analytical expression and graphic analysis was developed. The influence of leaf end structure on penumbra was analyzed quantitatively, and a set of three-dimensional structure design of dynamic multi-leaf collimator was completed. The feasibility of the structural design and analysis model was verified through experimental measurements.


Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas , Dosagem Radioterapêutica
5.
Foods ; 12(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36765975

RESUMO

Monascus red pigments (MRPs), which are a kind of natural colorant produced by Monascus spp., are widely used in the food and health supplements industry but are not very stable during processing and storage. Thus, MRPs were embedded into liposome membranes using a thin-film ultrasonic method to improve stability in this study. Monascus red pigments liposomes (MRPL) exhibited spherical unilamellar vesicles (UV) with particle size, polydispersity indexes (PDI), and zeta potential of 20-200 nm, 0.362 ± 0.023, and -42.37 ± 0.21 mV, respectively. pH, thermal, light, metal ion, storage, and in vitro simulated gastrointestinal digestion stability revealed that, compared with free MRPs, liposomes embedding significantly enhanced the stability of MRPs when exposed to adverse environmental conditions. Furthermore, anticancer assay suggested that MRPL exhibited a stronger inhibitory effect on MKN-28 cells by damaging the integrity of cells, with the IC50 value at 0.57 mg/mL. Overall, MRPLs possess stronger stability in external environment and in vitro simulated digestion with greater anticancer activity, indicating that MRPLs have the potential for promising application in the functional foods and pharmaceutical industries.

6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(1): 7-10, 2018 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-29862736

RESUMO

KylinRay-IMRT is the advanced radiotherapy treatment planning module of accurate radiotherapy system (KylinRay) aiming to provide accurate and efficient plan design platform. In this paper the system design, main functions and key technologies of KylinRay-IMRT were introduced. KylinRay-IMRT supports three dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and many other types of treatment plan design with function modules including patient data management, image registration and fusion, image contouring, image three dimensional reconstruction and visualization, three dimensional conformal radiotherapy planning, intensity modulated radiotherapy planning, plan evaluation and comparison, and report print. KylinRay-IMRT has been tested by the national standard YY/T 0889-2013, the results showed that the performance of KylinRay-IMRT can fully meet the standard requirements.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA