Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Ultrasound Med Biol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38849280

RESUMO

OBJECTIVE: Ultrasound beams sometimes need to be steered from the edge of linear array transducers to reach the sample volume with a desired Doppler angle in vascular exams. This phantom study aims to evaluate the impact of apertures located at the array edge on peak velocity (PV) measurements. METHODS: Three ultrasound scanner systems equipped with eight transducers from 3 major ultrasound vendors were tested using a flow phantom with a horizontal tube. Five spectral Doppler measurements with the aperture positioned at one edge of the array and 5 with the aperture at the center of the array were obtained using all available scanner-transducer combinations while maintaining all scan parameters and the sample volume in the same tube location. Differences in PVs between center and edge apertures were compared across 4 constant flow rates. RESULTS: The averaged PVs for all phantom flow rates ranged from 24.4 cm/s to 138.2 cm/s from the array center. The averaged PVs from the center aperture were significantly greater than the corresponding measurements from the edge aperture for each flow rate (all p < 0.001). The relative PV differences ranged from 6.7% to 19.4% across all transducers and flow rates. CONCLUSION: Significantly lower PVs were consistently shown with the Doppler beam aperture at the array edge compared to center among all tested systems. This may be due to a narrower aperture width, shifted central axis, and less intrinsic spectral broadening error at the array edge. Controlling variations in Doppler aperture location is important in clinical applications which depend on consistent velocity measurements.

2.
Pain Med ; 24(11): 1219-1223, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37478345

RESUMO

OBJECTIVE: To evaluate the safety and tolerability of MRI-guided focused ultrasound (MRgFUS) for the treatment of facet joint-mediated pain in human subjects for whom conventional treatment had failed. Secondarily, to evaluate effectiveness of the procedure. METHODS: Consecutive patients who underwent MRgFUS at our institution were retrospectively identified. Chart review was performed to obtain relevant clinical and technical data. All patients had chronic low back pain and positive comparative medial branch blocks. RESULTS: Twenty-six MRgFUS treatments in 20 patients were included. Mean sonication energy was 1436.6 Joules. The procedure was technically successful in all patients. Of the treated patients, 29.6% experienced short-term worsening of low back pain immediately after the procedure, all by 1-4 points on a 0-10 scale. One patient (3.8%) reported temporary worsening of preexisting radicular symptoms after the procedure. Of 21 treatments with clinical follow-up of at least 3 months available, 12 (57.1%) had >3 months' pain relief, 2 (10%) had <3 months' benefit, 6 (30%) reported no benefit, and 1 (5%) patient was lost to follow-up. In patients who reported at least some benefit with prior conventional radiofrequency ablation, 8/10 (80%) benefited from the MRgFUS procedure. CONCLUSION: The present study demonstrates that MRgFUS ablation of the lumbar facet joints is a safe and tolerable procedure in human subjects and could provide another option for patients for whom radiofrequency ablation had failed. More than half of all patients received significant durable pain relief, which jumped to 80% for patients who had experienced at least some benefit from prior radiofrequency ablations.


Assuntos
Dor Lombar , Bloqueio Nervoso , Articulação Zigapofisária , Humanos , Dor Lombar/terapia , Bloqueio Nervoso/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Resultado do Tratamento
3.
J Appl Clin Med Phys ; 24(5): e13962, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36942718

RESUMO

The well-referenced structural shielding design NCRP Report No. 147 uses workload information based on self-reported film-screen data from the AAPM Task Group 9 survey. The aim of this study was to assess the clinical workload distributions of modern digital radiography (DR) systems in general hospital and pediatric-only practices. A retrospective analysis of DR imaging data on four radiographic systems in a hospital practice and two radiographic systems in a pediatric practice, through a custom clinical DICOM header analytics program. A total of 203, 294 exposures from the general hospital practice and 25,415 from the pediatric practice from 2019 and 2021 were included. Values for kVp, mAs, and detector type (wall bucky, table bucky, or free detector) were extracted. For each exam, mAs was accumulated in a kVp histogram with bins 5 kVp wide and further parsed by detector type. Total workload was calculated by summing all exposures, then normalized by the number of patients. The median (25th and 75th percentile) workload in the hospital practice was 0.43 (0.22, 1.13) mA-min per patient, while the average was 1.36 ± 3.08. Pediatric data yielded a median (25th and 75th percentile) of 0.10 (0.05, 0.23) and an average of 0.29 ± 0.69 mA-min per patient. Mean number of patients per week was 230 adult and 57 pediatric. Hospital workload data is approximately 44% less than the NCRP Report No. 147 value.


Assuntos
Intensificação de Imagem Radiográfica , Carga de Trabalho , Adulto , Humanos , Criança , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Hospitais
4.
Med Phys ; 50(2): 831-836, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36542418

RESUMO

BACKGROUND: Digital radiography (DR) still presents many challenges and could have complex imaging acquisition and processing patterns in a clinical practice hindering quality standardization. PURPOSE: This technical note aims to report the 4-year experience with utilizing a custom DICOM metadata analytics program in clinical DR at a large institution. METHODS: Thirty-eight DR systems of three vendors at multiple locations were configured to automatically send clinical DICOM images to a DICOM receiver. A suite of custom MATLAB programs was established to extract and store public and private header data weekly. Specific use cases are provided for systematic image acquisition investigation, image processing harmonization, exposure index (EI) longitudinal monitoring and EI target optimization. RESULTS: For systematic acquisition investigation, an example of adult lumbar spine exam analysis was provided with statistics on manual acquisition versus the use of automatic exposure control (AEC, including AEC dose level, active cell, and backup timer), grid usage, and collimation for various projections. For processing harmonization, up to 12.6% of protocols were revealed to have processing parameter differences in an example of a mobile radiography fleet. In addition, inconsistent use of a post-acquisition image size function was also demonstrated, which resulted in anatomy size display variations. Bimonthly monitoring of median EI values showed expected trends, including changes after an AEC dose level adjustment for adult posterior-anterior chest imaging on a scanner system. An example of adult axillary shoulder EI target refinement was shared using the median value, eµ , based on the lognormal EI data distribution after parsing down to acquisitions with appropriate techniques. CONCLUSIONS: This analytics program enables systematic analysis of image acquisition and processing details. The information provides invaluable insights into real practice patterns, which can support data-driven quality standardization and optimization.


Assuntos
Metadados , Intensificação de Imagem Radiográfica , Radiografia , Processamento de Imagem Assistida por Computador/métodos , Coluna Vertebral
5.
J Appl Clin Med Phys ; 23(12): e13812, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36321326

RESUMO

There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source-to-image distance with software-based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise-only images, and line profiles were generated through a lung-rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC-processed images. An algorithm improvement to avoid introducing artifacts would be desired.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Torácica , Humanos , Radiografia Torácica/métodos , Estudos Retrospectivos , Radiografia , Intensificação de Imagem Radiográfica/métodos , Pulmão/diagnóstico por imagem , Doses de Radiação , Imagens de Fantasmas
6.
Abdom Radiol (NY) ; 47(6): 2158-2167, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35320381

RESUMO

PURPOSE: To compare the utility of a novel metal artifact reduction algorithm to standard imaging in improving visualization of key structures, diagnostic confidence, and patient-level confidence in malignancy in patients with suspected bladder cancer. METHODS: Patients with hip implants undergoing CT urography for suspected bladder malignancy were enrolled. Images were reconstructed using 3 methods: (1) Filtered Back Projection (FBP), (2) Iterative Metal Artifact Reduction (iMAR), and (3) Adaptive Iterative Metal Artifact Reduction (AiMAR) strength 4. In multiple reading sessions, three radiologists graded visualization of critical anatomic structures and artifact severity (6-point scales, lower scores desirable), and diagnostic confidence in blinded fashion. They also graded patient-level confidence in malignancy based on imaging findings in each patient. RESULTS: Thirty-two patients (8 females) with a mean age of 74.5 ± 8.5 years were included. The median (range) visualization scores for FBP, iMAR, and AiMAR were 3.6 (1.1-4.9), 1.6 (0.3-2.8), and 1.6 (0.3-2.6), respectively. Both iMAR and AiMAR had anatomic visualization and artifact scores better than FBP (P < 0.001 for both) and similar to each other (P > 0.05). Structures with the most improvement in visualization score with the use of metal artifact reduction algorithms included the obturator internus muscle, internal and external iliac nodal chains, and vagina. iMAR and AiMAR improved diagnostic confidence (P < 0.001) and patient-level confidence in malignancy (P ≤ 0.24). CONCLUSION: For patients with hip prostheses and suspected bladder malignancy, the use of iMAR or AiMAR was shown to significantly reduce metal artifacts, thus improving diagnostic confidence and patient-level confidence in malignancy.


Assuntos
Prótese de Quadril , Neoplasias da Bexiga Urinária , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Metais , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem
7.
Clin Gastroenterol Hepatol ; 20(12): 2780-2789, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35307593

RESUMO

BACKGROUND & AIMS: Duodenoscope-associated transmission of infections has raised questions about efficacy of endoscope reprocessing using high-level disinfection (HLD). Although ethylene oxide (ETO) gas sterilization is effective in eradicating microbes, the impact of ETO on endoscopic ultrasound (EUS) imaging equipment remains unknown. In this study, we aimed to compare the changes in EUS image quality associated with HLD vs HLD followed by ETO sterilization. METHODS: Four new EUS instruments were assigned to 2 groups: Group 1 (HLD) and Group 2 (HLD + ETO). The echoendoscopes were assessed at baseline, monthly for 6 months, and once every 3 to 4 months thereafter, for a total of 12 time points. At each time point, review of EUS video and still image quality was performed by an expert panel of reviewers along with phantom-based objective testing. Linear mixed effects models were used to assess whether the modality of reprocessing impacted image and video quality. RESULTS: For clinical testing, mixed linear models showed minimal quantitative differences in linear analog score (P = .04; estimated change, 3.12; scale, 0-100) and overall image quality value (P = .007; estimated change, -0.12; scale, 1-5) favoring ETO but not for rank value (P = .06). On phantom testing, maximum depth of penetration was lower for ETO endoscopes (P < .001; change in depth, 0.49 cm). CONCLUSIONS: In this prospective study, expert review and phantom-based testing demonstrated minimal differences in image quality between echoendoscopes reprocessed using HLD vs ETO + HLD over 2 years of clinical use. Further studies are warranted to assess the long-term clinical impact of these findings. In the interim, these results support use of ETO sterilization of EUS instruments if deemed clinically necessary.


Assuntos
Contaminação de Equipamentos , Óxido de Etileno , Humanos , Estudos Prospectivos , Reutilização de Equipamento , Desinfecção/métodos
8.
J Appl Clin Med Phys ; 22(1): 343-349, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33395503

RESUMO

PURPOSE: An increasing number of implantable or external devices can impact whether patients can receive radiological imaging examinations. This study examines and tests the Neulasta (pegfilgrastim) Onpro on-body injector in multiple imaging environments. METHODS: The injector was analyzed for four imaging modalities with testing protocols and strategies developed for each modality. In x-ray and computed tomography (CT), scans with much higher exposure than clinical protocols were performed with the device attached to an anthropomorphic phantom. The device was monitored until the completion of drug delivery. For magnetic resonance imaging (MRI), the device was assessed using a hand-held magnet and underwent the magnetically induced displacement testing in a 1.5T clinical MRI scanner room. For ultrasound, magnetic field changes were measured around an ultrasound scanner system with three transducers. RESULTS: For x-ray and CT no sign of device error was identified during or after the high radiation exposure scans. Drug delivery was completed at expected timing with expected volume. For MRI the device showed significant attractive force towards the hand-held magnet and a 50-degree deflection angle at 50 cm from the opening of the scanner bore. No further assessment from the gradient or radiofrequency field was deemed necessary. For ultrasound the maximum magnetic field change from baseline was measured to be +11.7 µT in comparison to +74.2 µT at 4 inches from a working microwave. CONCLUSIONS: No device performance issue was identified under the extreme test conditions in x-ray or CT. The device was found to be MR Unsafe. Magnetic field changes around an ultrasound system met the limitation set by manufacture. Patient ultrasound scanning is considered safe as long as the transducers do not inadvertently loosen the device.


Assuntos
Imageamento por Ressonância Magnética , Polietilenoglicóis , Filgrastim , Humanos , Imagens de Fantasmas
9.
Gastrointest Endosc ; 93(5): 1121-1130.e1, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32861752

RESUMO

BACKGROUND AND AIMS: Detection and characterization of focal liver lesions (FLLs) is key for optimizing treatment for patients who may have a primary hepatic cancer or metastatic disease to the liver. This is the first study to develop an EUS-based convolutional neural network (CNN) model for the purpose of identifying and classifying FLLs. METHODS: A prospective EUS database comprising cases of FLLs visualized and sampled via EUS was reviewed. Relevant still images and videos of liver parenchyma and FLLs were extracted. Patient data were then randomly distributed for the purpose of CNN model training and testing. Once a final model was created, occlusion heatmap analysis was performed to assess the ability of the EUS-CNN model to autonomously identify FLLs. The performance of the EUS-CNN for differentiating benign and malignant FLLs was also analyzed. RESULTS: A total of 210,685 unique EUS images from 256 patients were used to train, validate, and test the CNN model. Occlusion heatmap analyses demonstrated that the EUS-CNN model was successful in autonomously locating FLLs in 92.0% of EUS video assets. When evaluating any random still image extracted from videos or physician-captured images, the CNN model was 90% sensitive and 71% specific (area under the receiver operating characteristic [AUROC], 0.861) for classifying malignant FLLs. When evaluating full-length video assets, the EUS-CNN model was 100% sensitive and 80% specific (AUROC, 0.904) for classifying malignant FLLs. CONCLUSIONS: This study demonstrated the capability of an EUS-CNN model to autonomously identify FLLs and to accurately classify them as either malignant or benign lesions.


Assuntos
Inteligência Artificial , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Redes Neurais de Computação , Estudos Prospectivos , Sensibilidade e Especificidade
10.
Gut ; 70(7): 1335-1344, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028668

RESUMO

OBJECTIVE: The diagnosis of autoimmune pancreatitis (AIP) is challenging. Sonographic and cross-sectional imaging findings of AIP closely mimic pancreatic ductal adenocarcinoma (PDAC) and techniques for tissue sampling of AIP are suboptimal. These limitations often result in delayed or failed diagnosis, which negatively impact patient management and outcomes. This study aimed to create an endoscopic ultrasound (EUS)-based convolutional neural network (CNN) model trained to differentiate AIP from PDAC, chronic pancreatitis (CP) and normal pancreas (NP), with sufficient performance to analyse EUS video in real time. DESIGN: A database of still image and video data obtained from EUS examinations of cases of AIP, PDAC, CP and NP was used to develop a CNN. Occlusion heatmap analysis was used to identify sonographic features the CNN valued when differentiating AIP from PDAC. RESULTS: From 583 patients (146 AIP, 292 PDAC, 72 CP and 73 NP), a total of 1 174 461 unique EUS images were extracted. For video data, the CNN processed 955 EUS frames per second and was: 99% sensitive, 98% specific for distinguishing AIP from NP; 94% sensitive, 71% specific for distinguishing AIP from CP; 90% sensitive, 93% specific for distinguishing AIP from PDAC; and 90% sensitive, 85% specific for distinguishing AIP from all studied conditions (ie, PDAC, CP and NP). CONCLUSION: The developed EUS-CNN model accurately differentiated AIP from PDAC and benign pancreatic conditions, thereby offering the capability of earlier and more accurate diagnosis. Use of this model offers the potential for more timely and appropriate patient care and improved outcome.


Assuntos
Pancreatite Autoimune/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Endossonografia , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Neoplasias Pancreáticas/diagnóstico por imagem , Área Sob a Curva , Diagnóstico Diferencial , Humanos , Aprendizado de Máquina , Variações Dependentes do Observador , Pâncreas/diagnóstico por imagem , Curva ROC
11.
Acad Radiol ; 28(10): 1361-1367, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32631759

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of technology improvements on the outcomes of magnetic resonance-guided focused ultrasound (MRgFUS) treatments of symptomatic uterine leiomyomas (uterine fibroids). The study compared ablation volumes and incidence of adverse events in patient groups treated with two generations of MRgFUS systems from a single vendor. METHODS: The present study describes the results of a retrospective comparative study of two groups of women with symptomatic uterine leiomyomas who were clinically treated with MRgFUS at a single institution. Group 1 (n = 130) was treated using the first-generation system between March 2005 and December 2009. Group 2 (n = 71) was treated using the second-generation between December 2013 and September 2019. RESULTS: The second-generation MRgFUS system resulted in significantly improved nonperfused volume ratios in both dark and bright T2 fibroid categories compared with the first-generation system (dark - 80% versus46 %, p = 0.00002 and bright - 46% versus 32%, p = 0.001). There have been no recorded hospital admissions, no skins burns, and no reported major adverse events since the introduction of this second-generation ExAblate 2100 system with advanced safety and treatment planning features. CONCLUSION: This study has demonstrated that improvements to current MRgFUS technology resulted in significantly increased efficacy and patient safety of clinical treatments of patients with symptomatic uterine leiomyomas.


Assuntos
Leiomioma , Humanos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos
12.
Skeletal Radiol ; 50(1): 149-157, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32691125

RESUMO

OBJECTIVE: To evaluate a new adaptive iterative metal artifact reduction algorithm (AiMAR) in whole-body low-dose CT (WBLDCT) skeletal survey examinations. METHODS: Projection data were retrospectively obtained from 25 clinical WBLDCT skeletal survey patients, each with two types of metal implants. Images were reconstructed with bone and soft tissue kernels using four settings-original and AiMAR with strengths of 2, 4, and 5. All images were anonymized and randomized for a reader study, where three musculoskeletal radiologists independently determined the overall ranking of all series based on diagnostic quality, and local scoring of metal artifact and anatomy visualization for each implant. Quantitative image noise analysis was performed in areas close to the implants. Intraclass correlation coefficients (ICC) and Krippendorff's alpha were computed for inter-rater reliability. RESULTS: AiMAR 4 was ranked the highest for 64.3% of the series across eight types of implants. For local scoring task, AiMAR 4 showed better metal artifact and anatomy visualization than the original and AiMAR 2. AiMAR 4 was comparable in anatomy visualization but inferior to AiMAR 5 in metal artifact scores. AiMAR 4 led to 56.3% noise reduction around the implant areas compared with the original images, and AiMAR 5 68.1% but also resulted in anatomy blurring in 40% of the implants. ICC and Krippendorff's alpha revealed at least substantial reliability in the local scores among the readers. CONCLUSIONS: AiMAR was evaluated in WBLDCT skeletal surveys. AiMAR 4 demonstrated the highest overall quality ranking and improved local scores with noise reduction around implant areas.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Próteses e Implantes , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Mayo Clin Proc Innov Qual Outcomes ; 4(4): 464-468, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32793874

RESUMO

OBJECTIVE: To provide an initial report that patients with magnetic resonance imaging (MRI) non-conditional cardiac implanted electronic device (CIED) can undergo state-of-the-art magnetic resonance imaging-guided focused (MRgFUS) ablation procedures with careful planning and integration of the procedure into an established CIED MRI practice. PATIENT AND METHODS: We describe an MRgFUS ablation treatment of lumbar facet joints in a patient with an MRI non-conditional CIED (pacemaker), completed in accordance with our institutional CIED/MRI practice guidelines. RESULTS: A risk-benefit analysis by a coordinated multidisciplinary team before this treatment was performed to account for the risks associated with the MRI non-conditional pacemaker in the context of the MRgFUS procedure. CONCLUSION: The patient had no adverse cardiac event during or following this procedure.

14.
J Appl Clin Med Phys ; 21(10): 192-199, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32779836

RESUMO

PURPOSE: Ultrasound grayscale imaging preset optimization has often been qualitative and dependent upon vendor application specialists. This study aimed to propose a systematic approach for grayscale imaging preset optimization and apply the approach in a clinical abdominal scan setting. METHODS: A six-step approach was detailed including identification of clinical task, adjustment of basic parameters, fine-tuning of advanced parameters, image performance metrics confirmation, clinical evaluation and data analysis, and implementation of new presets and monitoring of clinical usage. Its application in an abdominal scanning task was described for each step with phantoms, volunteers, and software tools. RESULTS: Clinical image data analytics facilitated the understanding of the imaging task, relevant transducers, and target characteristics, in addition to specific requests from radiologists. Quantitative measurements were made on global image contrast and gray map function. In addition, clinically relevant phantoms and volunteer scans without and with acoustic distortion layers were involved to determine the new presets. Furthermore, phantom signal to noise ratio study and clinical evaluation using volunteers with different body habitus were utilized to confirm the superiority of the new presets. Quantitative clinical usage monitoring demonstrated successful implementation of the new presets. CONCLUSIONS: A systematic approach for grayscale imaging preset optimization has been proposed and successfully applied for a specific clinical task. This approach was designed to be generalizable and relatively flexible, which would facilitate movement away from previous qualitative and subjective approaches.


Assuntos
Processamento de Imagem Assistida por Computador , Software , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Ultrassonografia
15.
J Appl Clin Med Phys ; 20(6): 134-140, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31002482

RESUMO

PURPOSE: It is unclear if a 3D transducer with the special design of mechanical swing or 2D array could provide acceptable 2D grayscale image quality for the general diagnosis purpose. The aim of this study is to compare the 2D image quality of a 3D intracavitary transducer with a conventional 2D intracavitary transducer using clinically relevant phantom experiments. METHODS: All measurements were performed on a GE Logiq E9 scanner with both a 2D (IC5-9-D) and a 3D (RIC5-9-D) transducer used in 2D mode. Selection of phantom targets and acquisition parameters were determined from analysis of 33 clinical pelvic exams. Depth of penetration (DOP), contrast response, contrast of anechoic cylinders (diameter: 6.7 mm) at 1.5 and 4.5 cm depths in transverse planes, and in-plane resolution represented by full-width half-maximum of pin targets at multiple depths were measured with transmit frequencies of 7 and 8 MHz. Spherical signal-noise-ratio (SNR) (diameter: 4 and 2 mm) at multiple depths were measured at 8 MHz. RESULTS: RIC5-9-D demonstrated <8% decrease in DOP for both transmit frequencies (7 MHz: 69.7 ± 8.2 mm; 8 MHz: 64.3 ± 7.8 mm) compared with those from IC5-9-D (7 MHz: 73.9 ± 4.4 mm; 8 MHz: 69.4 ± 7.8 mm). A decreased anechoic contrast was observed with a 4.5 cm depth for RIC5-9-D (7 MHz: 23.2 ± 1.8 dB, P > 0.05; 8 MHz: 17.7 ± 0.9 dB, P < 0.01) compared with IC5-9-D (7 MHz: 25.9 ± 1.2 dB; 8 MHz: 21.5 ± 0.8 dB). The contrast response and spatial resolution performance were comparable between the two transducers. RIC5-9-D showed comparable SNR of anechoic spheres compared to IC5-9-D. CONCLUSIONS: 2D images from a 3D probe exhibited comparable overall image quality for routine clinical pelvic imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia/instrumentação , Desenho de Equipamento , Humanos , Razão Sinal-Ruído
16.
J Digit Imaging ; 32(2): 251-259, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30623273

RESUMO

Our ultrasound practice is becoming even more focused on managing practice resources and improving our efficiency while maintaining practice quality. We often encounter questions related to issues such as equipment utilization and management, study type statistics, and productivity. We are developing an analytics system to allow more evidence-based management of our ultrasound practice. Our system collects information from tens of thousands of DICOM images produced during exams, including structured reporting, public and private DICOM headers, and text within the images via optical character recognition (OCR). Inventory/location information augments the data aggregation, and statistical analysis and metrics are computed such as median exam length (time from the first image to last), transducer models used in an exam, and exams performed in a particular room, practice location, or by a given sonographer. Additional reports detail the length of a scan room's operational day, the number and type of exams performed, the time between exams, and summary data such as exams per operational hour and time-based room utilization. Our findings have already helped guide practice decisions: two defective probes were not replaced (a savings of over $10,000) when utilization data showed that three or more of the shared probe model were always idle; neck exams are the most time-consuming individually, but abdomen exam volumes cause them to consume the most total scan time, making abdominal exams the better candidates for efficiency optimization efforts. A small subset of sonographers exhibit the greatest scanning and between-scan efficiency, making them good candidates for identifying best practices.


Assuntos
Eficiência Organizacional , Administração da Prática Médica/estatística & dados numéricos , Sistemas de Informação em Radiologia/estatística & dados numéricos , Ultrassonografia , Prática Clínica Baseada em Evidências , Humanos , Melhoria de Qualidade
17.
AJR Am J Roentgenol ; 212(2): 395-401, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30667317

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the performance of three metal artifact reduction methods in dual-energy CT (DECT) examinations of instrumented spines. MATERIALS AND METHODS: Twenty patients with instrumented spines who underwent spine DECT were retrospectively identified. All scans were obtained on a dual-source 128-MDCT scanner. In addition to the original DE mixed images, DECT images were reconstructed using an iterative metal artifact reconstruction algorithm (DE iMAR), virtual monochromatic imaging (VMI) algorithm (DE Mono+), and a combination of the two algorithms DE iMAR and DE Mono+, which we refer to here as "DE iMAR Mono+." The four image series were anonymized and randomized for a reader study. Four experienced neuroradiologists rated the images in terms of artifact scores of four anatomic regions and overall image quality scores in both bone and soft-tissue display window settings. In addition, a quantitative analysis was performed to assess the performance of the three metal artifact reduction methods. RESULTS: There were statistically significant differences in the artifact scores and overall image quality scores among the four methods (both, p < 0.001). DE iMAR Mono+ showed the best artifact scores and quality scores (all, p < 0.001). The intraclass correlation coefficient for the overall image quality score was 0.779 using the bone display window and 0.892 using the soft-tissue display window (both, p < 0.001). In addition, DE iMAR Mono+ reduced the artifacts by the greatest amount in the quantitative analysis. CONCLUSION: The method that used DE iMAR Mono+ showed the best performance of spine metal artifact reduction using DECT data. These results may be specific to this CT vendor and implant type.


Assuntos
Artefatos , Parafusos Ósseos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Metais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Estudos Retrospectivos
18.
J Appl Clin Med Phys ; 19(4): 252-260, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29749048

RESUMO

OBJECTIVES: Both projection and dual-energy (DE)-based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants. MATERIALS AND METHODS: Five phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single-energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection-based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast-to-noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro-radiologists independently ranked the artifact reduction. RESULTS: The DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro-radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental. CONCLUSIONS: The SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.


Assuntos
Artefatos , Algoritmos , Humanos , Metais , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
19.
J Appl Clin Med Phys ; 19(3): 336-342, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29542277

RESUMO

Because of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists' tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1-6-D and ten 9L-D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared - a Supersonic Aixplorer scanner with a SL10-2 and a SL15-4 transducer, and an abovementioned GE scanner with 9L-D transducer. Two stepped cylinders with diameters of 4.05-10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in-house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15-4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE-related tasks in the clinical environment.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Transdutores
20.
J Neuroimaging ; 28(3): 307-312, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29319202

RESUMO

BACKGROUND AND PURPOSE: SISCOM and STATISCOM were clinically proved to be effective for ictal/inter-ictal single-photon emission computed tomography (SPECT) analysis coregistered with magnetic resonance imaging (MRI) for seizure localization. Recently, a software package also became available for this analysis. This study aimed to investigate and compare the performance of these analysis methods for seizure localization. METHODS: A total of 378 patients who underwent 99m Tc-ethyl cysteinate dimer (ECD) SPECT scans were retrospectively reviewed and 28 remained after applying exclusion criteria. Their SPECT and MRI images were analyzed with SISCOM (with z-score of 1.5 and 2), STATISCOM, and MIMneuro, resulting in a total of 112 image data sets. Two experienced radiologists participated in the blind review process using a custom tool and they can mark up to two hyper- and/or hypoperfusion regions. Their review results were analyzed using the Jackknife Free Response Receiver-Operating Characteristics (JAFROC) test and the JAFROC figure-of-merit (FoM) was reported for each method. The interobserver agreement was also assessed using Cohen's kappa test. RESULTS: Based on the readers' two choices, averaged FoM was 85.7%, 83.9%, 66.1%, and 51.8% for STATISCOM, MIMneuro, SISCOM (z-score = 2), and SISCOM (z-score = 1.5), respectively. The average confidence rating was 2.5, 2.3, 1.6, and 1.1 for STATISCOM, MIMneuro, SISCOM (z-score = 2), and SISCOM (z-score = 1.5), respectively. For interobserver agreement, kappa was .742 for STATISCOM, .816 for MIMneuro, .517 for SISCOM (z-score = 2), and .441 for SISCOM (z-score = 1.5; all P < .001). CONCLUSION: Our study demonstrated that STATISCOM showed the best performance for seizure localization, which was closely followed by MIMneuro. In addition, MIMneuro was not inferior to SISCOM with either z-score.


Assuntos
Encéfalo/diagnóstico por imagem , Epilepsia/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA