1.
Oral Dis ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38654640

RESUMO

OBJECTIVE: To carry out a systematic review and meta-analysis of randomized controlled clinical trials (RCTs) and controlled clinical trials (CCTs) comparing scaling and root planing (SRP) or placebo with subgingival application of xanthan-based CHX (chlorhexidine) gel as adjunct to SRP. MATERIALS AND METHODS: The literature search was carried out in PubMed/MEDLINE, EMBASE, and SCOPUS; primary outcomes were probing pocket depth (PPD) reduction and gain in clinical attachment level (CAL). RESULTS: Overall, 15 studies were included. Three studies were judged to be at moderate risk of bias while the remaining 12 were rated at high risk of bias. A significant improvement in PPD reduction (standardized mean difference, SMD, 0.87, 95% CI, 0.41-1.34) and CAL gain (SMD = 0.84, 95% CI, 0.36-1.33) emerged for the SRP + CXH gel compared to the SRP alone group, in the presence of significant high heterogeneity among the studies. CONCLUSIONS: Our systematic review and meta-analysis showed that xanthan-based chlorhexidine gel as adjunct to non-surgical periodontal therapy gives benefit in terms of PPD reduction and CAL gain as compared to non-surgical periodontal therapy only. Since there was high heterogeneity among studies and the quality of the evidence is low, further studies characterized by a better methodology, adequate sample size and longer follow-up are warranted in the next future. REGISTRATION: The protocol of this scoping review was registered in the International Prospective Register of Systematic Reviews (https://www.crd.york.ac.uk/PROSPERO) with ID: CRD42023391589.

2.
J Clin Med ; 12(11)2023 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-37298041

RESUMO

Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments. The present review was registered with PROSPERO (CRD42020161875) and the protocol was developed according to the PRISMA statement. An electronic search was performed on three databases (PubMed, Embase and Cochrane Central) up to May 2023. Data extraction was followed by qualitative and quantitative analysis of the included studies. Three randomized controlled clinical trials and three controlled clinical trials (number of patients = 230; number of dental implants = 230) with a follow-up of between 12 and 36 months were included. No significant differences were observed between prefabricated versus customized (CAD/CAM) abutments regarding midfacial mucosal recession, interproximal papillae and pink aesthetic score (PES) after 12 months. Conclusion: The potential benefits of CAD/CAM abutments on soft tissues should be better clarified in future investigations. The usage of customized CAD/CAM abutments in everyday clinical practice should be based on a careful case-by-case evaluation (CRD42020161875).

3.
J Clin Med ; 11(21)2022 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-36362471

RESUMO

BACKGROUND: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles. METHODS: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle (EA) measured at 3 years of follow-up visits (t1) were calculated for two different groups: Group 1 (153 implants) for restorations with angle between implant axis and prosthetic emergence angle from ≥30°, and Group 2 (67 implants) for those with angle ≤30°, respectively. Image J software was used for the measurements. Moreover, peri-implant soft tissue parameters such as pocket probing depth (PPD), plaque index (PI) and gingival index (GI) were assessed, respectively. RESULTS: A total of 57 patients were included in the analysis and a total of 220 implants were examined. Mean (±SD) EA in Groups 1 and 2 was 46.4 ± 12.2 and 24.5 ± 4.7 degrees, respectively. After 3 years of follow-up, a PPD difference of 0.062 mm (CI95% -0.041 mm; 0.164 mm) was calculated between the two groups and was not statistically significant (p = 0.238). Similar results were found for PI (OR = 0.78, CI95% 0.31; 1.98, p = 0.599). Furthermore, GI scores of 2 and 3 were found for nine implants (5.9%) in Group 1, and for five implants in Group 2 (7.5%). A non-significant difference (p = 0.76) was found. CONCLUSIONS: Peri-implant soft-tissue health does not seem to be influenced by EA itself, when a proper emergence profile is provided for implant-supported reconstructions in anterior areas.

4.
J Clin Med ; 11(7)2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35407622

RESUMO

The aim of the present retrospective study was to assess marginal bone changes around implants restored with different prosthetic emergence profile angles. Patients were treated with implants supporting fixed dentures and were followed for 3 years. Marginal bone levels (MBL) measured at the prosthesis installation (t0) and at the 3-year follow-up visit (t1) were considered. The MBL change from t0 to t1 was investigated. Two groups were considered: Group 1 for restorations with an angle between implant axis and prosthetic emergence profile >30°, and Group 2 for those with an angle ≤30°, respectively. Moreover, peri-implant soft tissue parameters, such as the modified bleeding index (MBI) and plaque index (PI) were assessed. Seventy-four patients were included in the analysis and a total of 312 implants were examined. The mean EA in groups 1 and 2 was 45 ± 4 and 22 ± 7 degrees, respectively. The mean marginal bone level change (MBL change) of 0.06 ± 0.09 mm and 0.06 ± 0.10 mm were, respectively, in groups 1 and 2. The difference in the MBL change between the two groups was not statistically significant (p = 0.969). The MBL change does not seem to be influenced by the emergence angle for implants with a stable internal conical connection and platform-switching of the abutment diameter.

5.
Int J Esthet Dent ; 17(1): 42-56, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35175007

RESUMO

The esthetic success of a case requiring implant therapy mainly depends on both the correct planning and the surgical-prosthetic execution. However, planning and surgical implementation according to prosthetically guided criteria are not always possible due to contingent anatomical limitations. When this is further complicated by the presence of mucogingival deficiencies in a highly visible esthetic area, the management of the case can become very complex. The present case report describes the presurgical and surgical management of a case of maxillary lateral incisor agenesis in the absence of sufficient vertical space. Through orthodontic therapy, the opening of the deep overbite and the alignment of the maxillary and mandibular arches were obtained, allowing for an implant positioning without compromises dictated by anatomical limitations. Finally, through mucogingival surgery and careful management of the provisional prosthetic phase, an optimal esthetic profile was achieved.


Assuntos
Estética Dentária , Incisivo , Humanos , Incisivo/anormalidades , Maxila/cirurgia
6.
J Clin Med ; 10(13)2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34209354

RESUMO

To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and -0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS.

7.
Odontology ; 109(4): 884-894, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34075492

RESUMO

Impression accuracy is fundamental to achieve a passive fit between implants and the superstructure. Three transfer types were tested to evaluate the differences in impression accuracy and their efficiency in case of different implant angles. A master model with four implant analogues placed at 0°, 15° and 35° was used. 27 impressions were taken with three different types of impression coping: closed tray technique coping (CT), open tray technique coping (COT) and telescopic open tray coping (TOT). The impressions were poured. Analogues were matched with scan bodies to be scanned and exported in STL. An implant bar was designed from each STL and another one from the master model. A comparison between these bars was obtained. Linear and angular measurements for every type of coping were calculated for different angulations. The collected data were analyzed with ANOVA test (95% of confidence). Student's t test showed a significative discrepancy (p ≤ 0.001) on linear and angular measurements on Δx, Δy, Δz with different transfer types as well as diverse implant positioning angles (p ≤ 0.001). Within the limitations of this study, it can be concluded that the coping type and the implants divergence may be significant parameters influencing the impression accuracy.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Modelos Dentários
8.
Materials (Basel) ; 13(14)2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32668745

RESUMO

BACKGROUND: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal 5° conical connection placed in a subcrestal position. MATERIALS AND METHODS: Patients treated with fixed prostheses supported by implants placed at a subcrestal level between 2012 and 2018 were recalled for a follow-up examination. All implants had 5° internal conical connection with platform switching. Radiographic marginal bone level (MBL) was measured. MBL change between prosthetic delivery (t0) and follow-up examination (t1) was calculated. A multiple regression model was performed to identify the most significant predictors on MBL change. RESULTS: Ninety-three patients and 410 implants, with a mean follow-up of 2.72 ± 1.31 years, were examined. Mean MBL was -1.09 ± 0.65 mm and -1.00 ± 0.37 mm at t0 and t1, respectively, with a mean bone remodeling of 0.09 ± 0.68 mm. An implant's vertical position in relation to the bone crest, the year of follow up and the presence of type-2 controlled diabetes were demonstrated to be influencing factors for MBL modifications. CONCLUSIONS: Subcrestally placed implants with platform switching and internal conical connection maintained stable bone levels over a mean follow-up of more than 2 years. How a tight internal conical connection between abutment and implant may contribute to this clinical evidence should be more deeply investigated. MBL variations seem to be mostly influenced by an implant's vertical position and presence of type-2 controlled diabetes.

9.
Artigo em Inglês | MEDLINE | ID: mdl-32032402

RESUMO

This retrospective study evaluated hard and soft tissue response and reported mechanical and technical complications around computer-aided design/computer-assisted manufactured (CAD/CAM) abutments. A total of 123 patients restored with titanium, gold-hue titanium, and zirconia CAD/CAM abutments were included (N = 291). Each patient was followed up for at least 2 years. Clinical and radiographic parameters were assessed annually and complications were recorded. No implant or reconstruction failures were reported. One fracture of a zirconia abutment occurred. The prosthetic survival rate after 4 years of function for restorations and abutments was 100% and 99.66%, respectively. No significant differences in biologic and radiographic indices were found. The bleeding on probing index was positive at 42% of implant sites, and it had no significant correlation with the overall change in marginal bone level (0.02 mm) of bone gain. The short-term survival of CAD/CAM abutments was reliable, no matter of the material used for manufacturing.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Desenho Assistido por Computador , Dente Suporte , Seguimentos , Humanos , Estudos Retrospectivos , Titânio , Zircônio
10.
Int J Oral Implantol (Berl) ; 12(1): 105-113, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31116191

RESUMO

PURPOSE: To evaluate the reliability of a conometric system for fixed retention of complete prostheses (CPs) on four implants after 5 years of function. MATERIALS AND METHODS: Twenty-five patients with a completely edentulous mandible received four implants supporting a CP. A total of 100 implants were immediately loaded with CPs on conometric abutments. A follow-up of 5 years was observed for each patient. Outcome measures were prosthesis and implant success, complications, probing pocket depth changes, marginal bleeding and plaque changes, and patient satisfaction. RESULTS: One patient dropped-out. In total, 96 implants supporting the 24 CPs completed the follow-up examination at 5 years. No implant failed. Two framework fractures occurred after 4 and 5 years of function. No loss of retention was recorded for the CPs. Mucositis was recorded for two implants after 1 year of prostheses function for two patients, for one implant after 3 years and for two implants after 4 years in different patients and successfully treated with interceptive supportive therapy. No significant differences were found between Plaque Index (PI) at baseline and after 2 years (P = 1.0); similar findings were calculated between PI at baseline and after 5 years (P = 0.6) of function. At baseline, after 2 and after 5 years, respectively, 69%, 64% and 56% of implants showed a PI of 0; 31%, 36% and 44% of implants showed a PI between 1 and 3. Modify Bleeding Index (MBI) was not significantly different both between baseline and after 2 years of function (P = 1.0) and between baseline and 5 years of function (P = 0.5). At baseline, after 2 and after 5 years, respectively, 69%, 65% and 61% of implants showed a MBI of 0; 27%, 28% and 29% of implants showed a MBI of 1; and 4%, 7% and 10% of implants showed a MBI of 2. The mean probing pocket depth was 1.2 ± 0.4 mm at baseline, 1.2 ± 0.4 mm after 2 years and 1.4 ± 0.5 mm after 5 years of function. The differences were not statistically significant between baseline and 2 years (P = 1.0) and between baseline and 5 years (P = 0.1). From the patient satisfaction questionnaire, 85% percent of patients were satisfied from both aesthetic and functional points of view after 5 years of conometric prostheses function. CONCLUSIONS: The present implant-supported conometric retention system can be used to give fixed retention to a CP supported by four implants. An adequate metal framework should be provided to the definitive restoration in order to avoid fractures in the long term.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Artigo em Inglês | MEDLINE | ID: mdl-29447322

RESUMO

The conometric retention system was proposed and described as a predictable alternative to retain fixed implant-supported complete dentures and, more recently, to retain fixed partial restorations. Currently available studies describe a technique based on the Ankylos (Dentsply) implant system and stock conic coupling abutments. The purpose of this case series study is therefore to demonstrate the possibility of using Atlantis computer-aided design/computer-assisted manufacture technology to produce Conus abutments (Dentsply) and using the fixed conometric retention with other implant brands for which appropriate stock conic coupling abutments are not available.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô , Prótese Dentária Fixada por Implante , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polimetil Metacrilato
12.
Int J Oral Maxillofac Implants ; 33(1): 23-30, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29340342

RESUMO

PURPOSE: The aim of this in vitro study was to verify whether or not stock and computer-aided design/computer-aided manufacturing (CAD/CAM) abutments show similar precision in the connection with the respective implants. MATERIALS AND METHODS: Ten CAD/CAM titanium abutments were compared with 10 stock titanium abutments. Each abutment fit a regular-platform implant (Institute Straumann). Implants and abutments were measured independently and then connected. During the connection procedure, the torque was measured using a six-axes load cell. Then, outer geometric features of the implant-abutment connection were measured again. Finally, the assembly was sectioned to provide the analysis of inner surfaces in contact. The geometric measurements were performed using a multisensored opto-mechanical coordinate measuring machine. The following parameters were measured and compared for the CAD/CAM and stock titanium abutment groups, respectively: width of interference and interference length between the conical surfaces of the implant and abutment; and volume of material involved in the implant-abutment connection. RESULTS: Interference width mean ± SD values of 18 ± 0.5 and 14 µ 0.5 µm were calculated for the stock and CAD/CAM titanium abutment groups, respectively. The difference was statistically significant (P = .02). Furthermore, the interference length mean ± SD values of 763 ± 10 and 816 ± 43 µm were calculated for stock and CAD/CAM titanium abutment groups, respectively. The difference was also statistically significant (P = .04). Finally, the volume of material involved in the implant-abutment connection was compared between stock and CAD/CAM titanium abutment groups; the mean ± SD values of 0.134 ± 0.014 and 0.108 ± 0.023 mm3 were significantly different (P = .009). CONCLUSION: Both standard and CAD/CAM abutment groups showed a three-dimensional (3D) seal activation after the screw tightening. Nevertheless, stock titanium abutments showed a significantly higher volume of material involved in the implant-abutment connection compared with that of CAD/CAM titanium abutments.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô , Implantes Dentários , Humanos , Teste de Materiais , Titânio , Zircônio
13.
Implant Dent ; 26(5): 756-761, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28945671

RESUMO

OBJECTIVE: To evaluate in vitro the sealing capability at the prosthetic connection interface of 2 conometric systems. MATERIALS AND METHODS: Two conometric systems with the same design and different material were used, for a total of 24 samples. Each sample was assembled by a tapered abutment and respective coping. In group A, the copings were made of gold, whereas in group B they were made of PEEK. Three µL of mix bacterial suspension (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Fusobacterium nucleatum species) was inoculated into the abutment screw hole, and the coping was inserted on the abutment. Samples were immersed into culture tubes and incubated for 24, 48, and 72 hours into anaerobic conditions. Visual evaluation of turbidity was performed at each time point. Qualitative-quantitative assessment using real-time polymerase chain reaction was performed at 72 hours. Any difference between the groups was checked by means of Fisher exact test. RESULTS: Microbial leakage occurred in both groups, and there was no statistically significant difference between groups. Microbial concentration resulted in a presence inferior to 1 × 10 copies/µL in all positive assemblies. CONCLUSIONS: Because of the low bacterial count, it can be concluded that a minimal bacterial infiltration may be allowed by conometric interfaces for prosthetic connection.


Assuntos
Dente Suporte , Implantes Dentários/microbiologia , Infiltração Dentária/microbiologia , Aggregatibacter actinomycetemcomitans , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Fusobacterium nucleatum , Humanos , Técnicas In Vitro , Porphyromonas gingivalis
14.
Artigo em Inglês | MEDLINE | ID: mdl-28817129

RESUMO

The aim of this study was to compare the interproximal papilla stability of restorations supported by computer-aided design/computer-assisted manufacture (CAD/CAM) abutments to those supported by prefabricated stock abutments in anterior areas over a 2-year follow-up. Abutments were selected depending on implant inclination and thickness of buccal peri-implant soft tissues from the following: zirconia stock, titanium stock, zirconia CAD/CAM and titanium CAD/CAM. Differences between the height of the papilla tip were measured (REC). RESULTS: REC values of titanium and zirconia CAD/CAM abutments were significantly lower than those of titanium and zirconia stock. The use of titanium and zirconia CAD/CAM abutments is related to better interproximal papillae stability.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô , Papila Dentária/patologia , Planejamento de Prótese Dentária , Adulto , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Projeto do Implante Dentário-Pivô/métodos , Planejamento de Prótese Dentária/métodos , Estética Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Titânio/uso terapêutico , Zircônio/uso terapêutico
15.
Clin Oral Implants Res ; 28(10): 1263-1268, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27699895

RESUMO

PURPOSE: The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue in patients with thin gingival biotype. MATERIAL AND METHODS: Thirty-seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all-ceramic crown has been tried on gold, titanium and zirconia abutment. Peri-implant soft-tissue color has been measured through a spectrophotometer after the insertion of each single abutment. Also facial peri-implant soft-tissue thickness was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a standardized tissue area and to collect the data before the statistical analysis in Lab* color space. ΔE parameters of the selected abutments were tested for correlation with mucosal thickness. Pearson correlation test was used. RESULTS: Only 15 patients met the study inclusion criteria on peri-implant soft-tissue thickness. Peri-implant soft-tissue color was different from that around natural teeth, no matter which type of restorative material was selected. Measurements regarding all the abutments were above the critical threshold of ΔE 8.74 for intraoral color distinction by the naked eye. The ΔE mean values of gold and zirconium abutments were similar (11.43 and 11.37, respectively) and significantly lower (P = 0.03 and P = 0.04, respectively) than the titanium abutment (13.55). In patients with a facial soft-tissue thickness ≤2 mm, the ΔE mean value of gold and zirconia abutments was significantly lower than that of titanium abutments (P = 0.03 and P = 0.04, respectively) and much more close to the reference threshold of 8.74. CONCLUSIONS: For peri-implant soft tissue of ≤2 mm, gold or zirconia abutments could be selected in anterior areas treatment. Moreover, the thickness of the peri-implant soft tissue seemed to be a crucial factor in the abutment impact on the color of soft tissues with a thickness of ≤2 mm.


Assuntos
Dente Suporte , Implantação Dentária Endóssea , Materiais Dentários , Gengiva/diagnóstico por imagem , Ouro , Titânio , Zircônio , Feminino , Gengiva/anatomia & histologia , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Estudos Prospectivos , Espectrofotometria
16.
Implant Dent ; 26(1): 66-72, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27824716

RESUMO

AIMS: To evaluate the ridge dimensions of posterior sextant in totally edentulous mandibles. MATERIAL AND METHODS: Cone beam computed tomography scans of 136 patients were retrospectively included for analysis. At sites corresponding to the second premolar (site a) and the mesial and distal root of first molar (sites b and c, respectively), bone height (BH) and bone width (BW) were measured. RESULTS: BH significantly decreased from site a (11.20 ± 4.03 mm) to site c (10.28 ± 3.33 mm). Males showed a significantly higher BH compared with females at all sites (P < 0.001), No significant impact of age on BH was found. BW increased from coronal to apical at all sites. At all height levels, BW increased from mesial to distal (BWc > BWb > BWa). CONCLUSIONS: BH decreased from mesial to distal, whereas BW showed an increase. Sex showed a significant impact on BH, with males having on average a 2.8 mm greater height than females, but not on BW. Age did not significantly influence the dimensions of the residual bone crest.


Assuntos
Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Arcada Edêntula/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Processo Alveolar/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Arcada Edêntula/patologia , Masculino , Pessoa de Meia-Idade , Radiografia Dentária , Estudos Retrospectivos
17.
Clin Oral Investig ; 20(8): 2191-2202, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26814715

RESUMO

BACKGROUND AND OBJECTIVE: Subepithelial connective tissue grafts (SeCTG) in conjunction with a coronally advanced flap (CAF) or with tunneling technique (TT) are common periodontal procedures with similar indications for the treatment of a denuded root surface; however, it is unclear whether patient discomfort and postoperative morbidity are comparable in both approaches. The aim of this randomized controlled clinical trial was to compare the patient morbidity and root coverage outcomes of a SeCTG used in combination with a CAF or TT. MATERIALS AND METHODS: For this single-center, randomized, clinical trial, patients were randomly assigned to receive SeCTG + CAF (control group) or SeCTG + TT (test group). Postoperative questionnaires at 3 days post intervention were administered to evaluate postoperative discomfort, bleeding, and inability to masticate. Evaluation of patients' perception of pain was performed using a visual analog scale (VAS). Clinical outcomes including percentage of root coverage (RC) and complete root coverage (CRC) were recorded 12 months postoperatively. RESULTS: Fifty patients (25 SeCTG + CAF and 25 SeCTG + TT) completed the study. Healing was uneventful for all test and control patients. The SeCTG + TT group showed a longer chair time (33.6 (3.6) and 23.6 (4.2) min for the SeCTG + TT and the SeCTG + CAF, respectively), as well as more painkiller consumption: 2736 vs. 1536 mg (p < 0.001). At the same time, the SeCTG + CAF group reported less pain or discomfort in all four sections of the questionnaire: pain experienced within the mouth as a whole, pain experienced throughout the day, pain experienced at night, and edema experienced after the surgery (p = 0.002, p = 0.001, p = 0.001, and p = 0001, respectively). Both treatments showed clinical efficacy in terms of root coverage as no differences per group were observed in the percentage of root coverage (87 vs. 85 %, p = 704) or patients with complete root coverage (60 vs. 52 %, p = 0.569). CONCLUSIONS: SeCTG + TT is associated with a greater incidence of pain and discomfort compared to SeCTG + CAF in early postoperative periods, as well as a longer chair time. Both treatments showed similar clinical efficacy in terms of root coverage. CLINICAL RELEVANCE: The results of this study may influence the surgeon's choice on which root coverage procedure should be performed considering the need of more chair time and more painkiller assumption with the tunneling technique.


Assuntos
Tecido Conjuntivo/transplante , Retração Gengival/cirurgia , Retalhos Cirúrgicos , Raiz Dentária/cirurgia , Adulto , Estética Dentária , Feminino , Humanos , Masculino , Medição da Dor , Dor Pós-Operatória/diagnóstico , Satisfação do Paciente , Inquéritos e Questionários , Resultado do Tratamento
18.
J Esthet Restor Dent ; 28(1): 43-55, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26358411

RESUMO

PURPOSE: The aim of this study was to transfer the provisional restoration emergence profile to the final implant-supported restoration and to buccal gingival margin (BGM) stability after 2 years of function. MATERIALS AND METHODS: A total of 33 patients were recruited for treatment of single gaps by means of 33 implant-supported restorations. Fixed provisional crowns were screwed to the fixture and adjusted until the complete peri-implant soft tissue maturation was achieved. After 12 weeks, a second fixture impression was taken by means of a pick-up customization technique in order to transfer the clinical aspect of the peri-implant soft tissues to the master cast. A definitive restoration was delivered. A standardized method from digital photographs was used to assess the gingival margin modification (BGM) from the provisional (P) to the definitive prosthesis installation at baseline (D0), and after 1 (D1) and 2 years (D2) of function. Also, marginal bone loss (MBL) was calculated after 1 (D1) and 2 years (D2) of definitive restoration function. RESULTS: The BGM index at the time of the final restoration installation (D0) was 0.12 ± 0.33 mm if compared with the BGM position of the provisional restoration (P); it was of 0.12 ± 0.46 mm after 1-year of follow-up (D1) and of 0.31 ± 0.21 after 2 years of function (D2). No significant difference was calculated between measurements in different follow-up visits (p > 0.05). No significant MBL was measured between the baseline (D0) and the 1-year follow-up (p = 0.816) with a mean MBL value of 0.2 ± 0.1 mm. Similar result was calculated after 2 years (p = 0.684) with a mean MBL value of 0.3 ± 0.2. CONCLUSION: A modified impression pick-up may be helpful to reproduce the gingival margin position from the provisional to the definitive restoration. Moreover, the gingival zenith position during the follow-up period seemed to be stable. CLINICAL SIGNIFICANCE: The modification of the standard impression pick-up technique may contribute to reproducing a natural emergence profile of esthetic implant prosthetic restorations (from the provisional to the definitive restoration.) With this technique, implant soft tissues stability around CAD-CAM (computer aided design-computer aided manufacturing) abutments can be easily obtained, and the customized abutment shape may better support the scalloped peri-implant soft tissues architecture, especially in anterior areas.


Assuntos
Bochecha/fisiopatologia , Técnica de Moldagem Odontológica , Gengiva/fisiopatologia , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
Clin Oral Investig ; 20(6): 1243-52, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26445857

RESUMO

OBJECTIVES: Subgingival margin placement is sometimes required due to different reasons and is often associated with adverse periodontal reactions. The purpose of this study was to determine if a single restoration with subgingival margin on a tooth, in the maxillary anterior zone, would affect its periodontal soft tissue parameters, and whether or not a deep chamfer preparation has a different influence in the periodontium when compared to a feather edge preparation. MATERIAL AND METHODS: Plaque and gingival indexes, periodontal probing depth, bleeding on probing, and patient's biotype were registered. One hundred six teeth were prepared with a deep chamfer, while 94 were prepared with a feather edge finishing line. Twelve months after the restoration delivery, the same parameters were evaluated. Repeated measure one-way analysis of variance (ANOVA) (α = 0.05) was used. RESULTS: A statistically significant difference between the baseline and the 12-month follow-up is present in regard to plaque index, gingival index, and periodontal probing depth, but no statistically significant difference between chamfer and feather edge finishing lines. There is a statistically significant difference between the baseline and the 12-month follow-up in regard to bleeding on probing. Feather edge preparation presents significantly more bleeding on probing and less gingival recession than the chamfer. CONCLUSIONS: Subgingival margins do influence the periodontal soft tissue response. Statistically significant difference exists between feather edge and chamfer finishing lines in regard to bleeding on probing and gingival recession. CLINICAL RELEVANCE: Subgingival margins should be carefully selected, especially when feather edge finishing line is utilized.


Assuntos
Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Doenças Periodontais/diagnóstico , Adulto , Índice de Placa Dentária , Método Duplo-Cego , Estética Dentária , Feminino , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Índice Periodontal , Estudos Prospectivos , Resultado do Tratamento
20.
Clin Oral Implants Res ; 27(12): e154-e160, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25808606

RESUMO

PURPOSE: The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years. MATERIAL AND METHODS: Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed. RESULTS: Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was -0.34 mm (SD of -0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed. CONCLUSIONS: It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations.


Assuntos
Prótese Dentária Fixada por Implante/métodos , Maxila/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos