Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Med Eng Phys ; 131: 104221, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-39284650

RESUMO

Tracking the position and orientation of a two-dimensional (2D) ultrasound scanner to reconstruct a 3D volume is common, and its accuracy is important. In this study, a specific miniaturized electromagnetic (EM) tracking system was selected and integrated with a 2D ultrasound scanner, which was aimed to capture hip displacement in children with cerebral palsy. The objective of this study was to determine the optimum configuration, including the distance between the EM source and sensor, to provide maximum accuracy. The scanning volume was aimed to be 320 mm × 320 mm × 76 mm. The accuracy of the EM tracking was evaluated by comparing its tracking with those from a motion capture camera system. A static experiment showed that a warm-up time of 20 min was needed. The EM system provided the highest precision of 0.07 mm and 0.01° when the distance between the EM source and sensor was 0.65 m. Within the testing volume, the maximum position and rotational errors were 2.31 mm and 1.48°, respectively. The maximum error of measuring hip displacement on the 3D hip phantom study was 4 %. Based on the test results, the tested EM system was suitable for 3D ultrasound imaging of pediatric hips to assess hip displacement when optimal configuration was used.


Assuntos
Fenômenos Eletromagnéticos , Quadril , Imageamento Tridimensional , Imagens de Fantasmas , Ultrassonografia , Humanos , Ultrassonografia/instrumentação , Criança , Quadril/diagnóstico por imagem
2.
ACS Sens ; 9(8): 3898-3906, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39175386

RESUMO

Innovative intraoral ultrasound devices with smart artificial intelligence-based identification for dento-anatomy could provide crucial information for oral health diagnosis and treatment and shed light on real-time detection of developmental dentistry. However, the grand challenge is that the current ultrasound technologies are meant for external use due to their bulkiness and low frequency. We report a compact versatile ultrasound intraoral device that consists of a rotational probe head robustly pivoted around a hand-held and portable handle for real-time imaging of intraoral anatomy using high-frequency ultrasonography (up to 25 MHz). The intraoral ultrasound device that could be adjusted for various orientations of the imaging planes by rotating the head provides real-time, high-resolution ultrasonograms of intraoral structures, including dento-periodontium of most tooth types and maxillary palate. Machine learning-based algorithms are integrated to automate the identification of important structures, including alveolar bone and cementum-enamel junction. The intraoral ultrasound device smartened with artificial intelligence could innovate oral health diagnosis and treatment plans toward precision health and patient care.


Assuntos
Aprendizado de Máquina , Ultrassonografia , Humanos , Ultrassonografia/métodos , Transdutores , Periodonto/diagnóstico por imagem
3.
Med Image Anal ; 98: 103305, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39168075

RESUMO

Three-dimensional (3D) freehand ultrasound (US) is a widely used imaging modality that allows non-invasive imaging of medical anatomy without radiation exposure. Surface reconstruction of US volume is vital to acquire the accurate anatomical structures needed for modeling, registration, and visualization. However, traditional methods cannot produce a high-quality surface due to image noise. Despite improvements in smoothness, continuity, and resolution from deep learning approaches, research on surface reconstruction in freehand 3D US is still limited. This study introduces FUNSR, a self-supervised neural implicit surface reconstruction method to learn signed distance functions (SDFs) from US volumes. In particular, FUNSR iteratively learns the SDFs by moving the 3D queries sampled around volumetric point clouds to approximate the surface, guided by two novel geometric constraints: sign consistency constraint and on-surface constraint with adversarial learning. Our approach has been thoroughly evaluated across four datasets to demonstrate its adaptability to various anatomical structures, including a hip phantom dataset, two vascular datasets and one publicly available prostate dataset. We also show that smooth and continuous representations greatly enhance the visual appearance of US data. Furthermore, we highlight the potential of our method to improve segmentation performance, and its robustness to noise distribution and motion perturbation.


Assuntos
Imageamento Tridimensional , Ultrassonografia , Humanos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Imagens de Fantasmas , Masculino , Próstata/diagnóstico por imagem , Algoritmos , Aprendizado Profundo , Redes Neurais de Computação
4.
J Dent ; 145: 105024, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38670332

RESUMO

OBJECTIVE: Rapid maxillary expansion is a common orthodontic procedure to correct maxillary constriction. Assessing the midpalatal suture (MPS) expansion plays a crucial role in treatment planning to determine its effectiveness. The objectives of this preliminary investigation are to demonstrate a proof of concept that the palatal bone underlying the rugae can be clearly imaged by ultrasound (US) and the reconstructed axial view of the US image accurately maps the MPS patency. METHODS: An ex-vivo US scanning was conducted on the upper jawbones of two piglet's carcasses before and after the creation of bone defects, which simulated the suture opening. The planar images were processed to enhance bone intensity distribution before being orderly stacked to fuse into a volume. Graph-cut segmentation was applied to delineate the palatal bone to generate a bone volume. The accuracy of the reconstructed bone volume and the suture opening was validated by the micro-computed tomography (µCT) data used as the ground truth and compared with cone beam computed tomography (CBCT) data as the clinical standard. Also included in the comparison is the rugae thickness. Correlation and Bland-Altman plots were used to test the agreement between the two methods: US versus µCT/CBCT. RESULTS: The reconstruction of the US palatal bone volumes was accurate based on surface topography comparison with a mean error of 0.19 mm for pre-defect and 0.15 mm and 0.09 mm for post-defect models of the two samples, respectively when compared with µCT volumes. A strong correlation (R2 ≥ 0.99) in measuring MPS expansion was found between US and µCT/CBCT with MADs of less than 0.05 mm, 0.11 mm and 0.23 mm for US, µCT and CBCT, respectively. CONCLUSIONS: It was possible to axially image the MPS opening and rugae thickness accurately using high-frequency ultrasound. CLINICAL SIGNIFICANCE: This study introduces an ionizing radiation-free, low-cost, and portable technique to accurately image a difficult part of oral cavity anatomy. The advantages of conceivable visualization could promise a successful clinical examination of MPS to support the predictable treatment outcome of maxillary transverse deficiency.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Técnica de Expansão Palatina , Ultrassonografia , Microtomografia por Raio-X , Animais , Suínos , Microtomografia por Raio-X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Técnica de Expansão Palatina/instrumentação , Ultrassonografia/métodos , Palato/diagnóstico por imagem , Palato/anatomia & histologia , Suturas Cranianas/diagnóstico por imagem , Suturas Cranianas/anatomia & histologia , Maxila/diagnóstico por imagem , Palato Duro/diagnóstico por imagem , Palato Duro/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
6.
Eur J Phys Rehabil Med ; 59(4): 535-542, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37746786

RESUMO

BACKGROUND: Accurately measuring the Cobb angle on radiographs is crucial for diagnosis and treatment decisions for adolescent idiopathic scoliosis (AIS). However, manual Cobb angle measurement is time-consuming and subject to measurement variation, especially for inexperienced clinicians. AIM: This study aimed to validate a novel artificial-intelligence-based (AI) algorithm that automatically measures the Cobb angle on radiographs. DESIGN: This is a retrospective cross-sectional study. SETTING: The population of patients attended the Stollery Children's Hospital in Alberta, Canada. POPULATION: Children who: 1) were diagnosed with AIS, 2) were aged between 10 and 18 years old, 3) had no prior surgery, and 4) had a radiograph out of brace, were enrolled. METHODS: A total of 330 spinal radiographs were used. Among those, 130 were used for AI model development and 200 were used for measurement validation. Automatic Cobb angle measurements were validated by comparing them with manual ones measured by a rater with 20+ years of experience. Analysis was performed using the standard error of measurement (SEM), inter-method intraclass correlation coefficient (ICC2,1), and percentage of measurements within clinical acceptance (≤5°). Subgroup analysis was conducted by severity, region, and X-ray system to identify any systematic biases. RESULTS: The AI method detected 346 of 352 manually measured curves (mean±standard deviation: 24.7±9.5°), achieving 91% (316/346) of measurements within clinical acceptance. Excellent reliability was obtained with 0.92 ICC and 0.79° SEM. Comparable performance was found throughout all subgroups, and no systematic biases in performance affecting any subgroup were discovered. The algorithm measured each radiograph approximately 18s on average which is slightly faster than the estimated measurement time of an experienced rater. Radiographs taken by the EOS X-ray system were measured more quickly on average than those taken by a conventional digital X-ray system (10s vs. 26s). CONCLUSIONS: An AI-based algorithm was developed to measure the Cobb angle automatically on radiographs and yielded reliable measurements quickly. The algorithm provides detailed images on how the angles were measured, providing interpretability that can give clinicians confidence in the measurements. CLINICAL REHABILITATION IMPACT: Employing the algorithm in practice could streamline clinical workflow and optimize measurement accuracy and speed in order to inform AIS treatment decisions.


Assuntos
Inteligência Artificial , Escoliose , Humanos , Adolescente , Criança , Estudos Transversais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Escoliose/diagnóstico por imagem
7.
Int J Paediatr Dent ; 33(5): 487-497, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37386727

RESUMO

BACKGROUND: Cone beam computed tomography (CBCT) is an imaging modality, which is used routinely in orthodontic diagnosis and treatment planning but delivers much higher radiation than conventional dental radiographs. Ultrasound is a noninvasive imaging method that creates an image without ionizing radiation. AIM: To investigate the reliability of ultrasound and the agreement between ultrasound and CBCT in measuring the alveolar bone level (ABL) on the buccal/labial side of the incisors in adolescent orthodontic patients. DESIGN: One hundred and eighteen incisors from 30 orthodontic adolescent patients were scanned by CBCT with 0.3-mm voxel size and ultrasound at 20 MHz frequency. The ABL, distance from the cementoenamel junction (CEJ) to the alveolar bone crest (ABC), was measured twice to evaluate the agreement between ultrasound and CBCT. In addition, the intra- and inter-rater reliabilities in measuring the ABL by four raters were compared. RESULTS: The mean difference (MD) in the ABL between ultrasound and CBCT was -0.07 mm with 95% limit of agreement (LoA) from -0.47 to 0.32 mm for all teeth. For each jaw, the MDs between the ultrasound and CBCT were -0.18 mm (for mandible with 95% LoA from -0.53 to 0.18 mm) and 0.03 mm (for maxilla with 95% LoA from -0.28 to 0.35 mm). In comparison, ultrasound had higher intra-rater (ICC = 0.83-0.90) and inter-rater reliabilities (ICC = 0.97) in ABL measurement than CBCT (ICC = 0.56-0.78 for intra-rater and ICC = 0.69 for inter-rater reliabilities). CONCLUSION: CBCT parameters used in orthodontic diagnosis and treatment planning in adolescents may not be a reliable tool to assess the ABL for the mandibular incisors. On the contrary, ultrasound imaging, an ionizing radiation-free, inexpensive, and portable diagnostic tool, has potential to be a reliable diagnostic tool in assessing the ABL in adolescent patients.


Assuntos
Processo Alveolar , Incisivo , Humanos , Adolescente , Reprodutibilidade dos Testes , Processo Alveolar/diagnóstico por imagem , Incisivo/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Maxila/diagnóstico por imagem , Ultrassonografia
8.
Ultrasound Med Biol ; 49(9): 1960-1969, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37277305

RESUMO

OBJECTIVE: An approach to estimation of hip displacement on ultrasound (US) images is described. Its accuracy is validated through numerical simulation, an in vitro study with 3-D-printed hip phantoms and pilot in vivo data. METHODS: A diagnostic index, migration percentage (MP), is defined by the ratio of acetabulum-femoral head distance to femoral head width. The acetabulum-femoral head distance could be measured directly on hip US images, while the femoral head width was estimated from the diameter of a best-fit circle. Simulation was performed to evaluate the accuracy of circle fitting with noiseless and noisy data. Surface roughness was also considered. Nine hip phantoms (three different sizes of femur head × three MP values) and 10 US hip images were used in this study. RESULTS: The maximum diameter error was 16.1 ± 8.5% when the roughness and noise were 20% of the original radius and 20% of the wavelet peak, respectively. In the phantom study, the percentage errors of MPs between the 3-D-design US and X-ray US were 0.3%-6.6% and 0.0%-5.7%, respectively. From the pilot clinical trial, the mean absolute difference between the X-ray-US MPs was 3.5 ± 2.8% (1%-9%). CONCLUSION: This study indicates that the US method can be used to evaluate hip displacement in children.


Assuntos
Paralisia Cerebral , Luxação do Quadril , Humanos , Criança , Luxação do Quadril/diagnóstico por imagem , Paralisia Cerebral/complicações , Paralisia Cerebral/diagnóstico por imagem , Cabeça do Fêmur/diagnóstico por imagem , Ultrassonografia , Imagens de Fantasmas
10.
Int J Dent ; 2023: 5494429, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845629

RESUMO

Background: Ultrasonography is a noninvasive, low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess periodontal biomarkers. Objectives: To evaluate the reliability of interlandmark distance measurements on intraoral ultrasound images of the periodontal tissues. Materials and Methods: Sixty-four patients from the graduate periodontics (n = 33) and orthodontics (n = 31) clinics were recruited. A 20 MHz handheld intraoral ultrasound transducer was used to scan maxillary and mandibular incisors, canines, and premolars. Distances between the alveolar bone crest and cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT) were measured by 3 raters. The intercorrelation coefficient (ICC) and mean absolute deviation (MAD) were calculated among and between the raters. Raters also scored images according to quality. Results: The ICC scores for intrarater reliability were 0.940 (0.932-0.947), 0.953 (0.945-0.961), and 0.859 (0.841-0.876) for ABC-CEJ, GT, and ABT, respectively. The intrarater MAD values were 0.023 (±0.019) mm, 0.014 (±0.005) mm, and 0.005 (±0.003) mm, respectively. The ICC scores for interrater reliability were 0.872 (95% CI: 0.836-0.901), 0.958 (95% CI: 0.946-0.968), and 0.836 (95% CI: 0.789-0.873) for ABC-CEJ, GT, and ABT, respectively. The interrater MAD values were 0.063 (±0.029) mm, 0.023 (±0.018) mm, and 0.027 (±0.012) mm, respectively. Conclusions: The present study showed the high reliability of ultrasound in both intrarater and interrater assessments. Results suggest there might be a potential use of intraoral ultrasound to assess periodontium.

11.
Ultrasound Med Biol ; 49(5): 1345-1350, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36813583

RESUMO

OBJECTIVE: Alveolar crestal bone thickness and level provide important diagnostic and prognostic information for orthodontic treatment, periodontal disease management and dental implants. Ionizing radiation-free ultrasound has emerged as a promising clinical tool in imaging oral tissues. However, the ultrasound image is distorted when the wave speed of the tissue of interest is different from the mapping speed of the scanner and, therefore, the subsequent dimension measurements are not accurate. This study was aimed at deriving a correction factor that can be applied to the measurements to correct for discrepancy caused by speed variation. METHODS: The factor is a function of the speed ratio and the acute angle that the segment of interest makes with the beam axis perpendicular to the transducer. The phantom and cadaver experiments were designed to validate the method. DISCUSSION: The comparisons agree well with absolute errors not more than 4.9%. Dimension measurements on ultrasonographs can be properly corrected by applying the correction factor without recourse to the raw signals. CONCLUSION: The correction factor has reduced the measurement discrepancy on the acquired ultrasonographs for the tissue whose speed is different from the scanner's mapping speed.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Humanos , Processo Alveolar/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia , Cadáver
12.
J Dent ; 112: 103752, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34314726

RESUMO

OBJECTIVE: Our goal was to automatically identify the cementoenamel junction (CEJ) location in ultrasound images using deep convolution neural networks (CNNs). METHODS: Three CNNs were evaluated using 1400 images and data augmentation. The training and validation were performed by an experienced nonclinical rater with 1000 and 200 images, respectively. Four clinical raters with different levels of experience with ultrasound tested the networks using the other 200 images. In addition to the comparison of the best approach with each rater, we also employed the simultaneous truth and performance level estimation (STAPLE) algorithm to estimate a ground truth based on all labelings by four clinical raters. The final CEJ location estimate was obtained by taking the first moment of the posterior probability computed using the STAPLE algorithm. The study also computed the machine learning-measured CEJ-alveolar bone crest distance. RESULTS: Quantitative evaluations of the 200 images showed that the comparison of the best approach with the STAPLE-estimate yielded a mean difference (MD) of 0.26 mm, which is close to the comparison with the most experienced nonclinical rater (MD=0.25 mm) but far better than the comparison with clinical raters (MD=0.27-0.33 mm). The machine learning-measured CEJ-alveolar bone crest distances correlated strongly (R = 0.933, p < 0.001) with the manual clinical labeling and the measurements were in good agreement with the 95% Bland-Altman's lines of agreement between -0.68 and 0.57 mm. CONCLUSIONS: The study demonstrated the feasible use of machine learning methodology to localize CEJ in ultrasound images with clinically acceptable accuracy and reliability. Likelihood-weighted ground truth by combining multiple labels by the clinical experts compared favorably with the predictions by the best deep CNN approach. CLINICAL SIGNIFICANCE: Identification of CEJ and its distance from the alveolar bone crest play an important role in the evaluation of periodontal status. Machine learning algorithms can learn from complex features in ultrasound images and have potential to provide a reliable and accurate identification in subsecond. This will greatly assist dental practitioners to provide better point-of-care to patients and enhance the throughput of dental care.


Assuntos
Odontólogos , Colo do Dente , Humanos , Aprendizado de Máquina , Papel Profissional , Reprodutibilidade dos Testes
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6632-6635, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947362

RESUMO

Delineation of alveolar bone aids the diagnosis and treatment of periodontal diseases. In current practice, conventional 2D radiography and 3D cone-beam computed tomography (CBCT) imaging are used as the non-invasive approaches to image and delineate alveolar bone structures. Recently, high-frequency ultrasound imaging is proposed as an alternative to conventional imaging methods to prevent the harmful effects of ionizing radiation. However, the manual delineation of alveolar bone from ultrasound imaging is time-consuming and subject to inter and intraobserver variability. This study proposes to use a convolutional neural network-based machine learning framework to automatically segment the alveolar bone from ultrasound images. The proposed method consists of a homomorphic filtering based noise reduction and a u-net machine learning framework for automated delineation. The proposed method was evaluated over 15 ultrasound images of tooth acquired from procine specimens. The comparisons against manual ground truth delineations performed by three experts in terms of mean Dice score and Hausdorff distance values demonstrate that the proposed method yielded an improved performance over a recent state of the art graph cuts based method.


Assuntos
Aprendizado de Máquina , Redes Neurais de Computação , Tomografia Computadorizada de Feixe Cônico , Humanos , Processamento de Imagem Assistida por Computador , Variações Dependentes do Observador , Ultrassonografia
14.
Eur Spine J ; 27(9): 2156-2164, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29523986

RESUMO

PURPOSE: This study aimed to determine the intra- and inter-rater reliabilities of spinal flexibility measurements using ultrasound imaging on non-surgical candidates with adolescent idiopathic scoliosis (AIS). METHODS: Twenty-eight consecutive consented AIS subjects (25 F; 3 M) were recruited; 24 subjects' data were used for analysis. This study explored curve magnitude differences between standing, prone and voluntary maximum side-bending postures to assess the reliability of spinal flexibility (SF). Two raters were included in this study. Four flexibility indices, PRSI, BRPI, B-PRSI, BRSI, based on the postural changes from standing to prone and from prone to bending position were defined. The reliability analysis was evaluated using the intra-class correlation coefficient (ICC) [1, 2] and the standard error of measurements (SEM). RESULTS: The ICC [1, 2] values of the intra-rater (R2 only) and inter-rater (R1 vs R2) reliabilities of the measurements (PRSI, BRPI, B-PRSI, BRSI) were (0.82, 0.64, 0.78, 0.91) and (0.78, 0.76, 0.84, 0.94), respectively. Among the four indices, the BRPI had the highest SEM values 1.42, and 0.73 for intra- and inter-raters results, respectively, while BRSI had the lowest SEM 0.04 and 0.02 for intra- and inter-rater, respectively. CONCLUSIONS: The BRPI, BRSI and B-PRSI could be measured reliably on US images when the Cobb angle at prone position was not close to zero. Using these three indices, information may provide more comprehensive information about the SF. Validity of spinal flexibility measurements still needed to be confirmed with a clinical study with more subjects. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Posicionamento do Paciente/métodos , Escoliose/diagnóstico por imagem , Adolescente , Criança , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Projetos Piloto , Postura/fisiologia , Reprodutibilidade dos Testes , Escoliose/fisiopatologia , Escoliose/cirurgia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/fisiopatologia , Posição Ortostática , Ultrassonografia/métodos , Ultrassonografia/normas
15.
Spine (Phila Pa 1976) ; 43(9): E494-E503, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28885287

RESUMO

STUDY DESIGN: A prospective randomized controlled trial. OBJECTIVE: The aim of this study was to investigate the effectiveness of orthotic management versus exercise on spinal curvature, body symmetry, and quality of life. SUMMARY OF BACKGROUND DATA: A number of well-designed studies comparing conservative treatment of adolescent idiopathic scoliosis (AIS) have been conducted and the evidence becomes stronger. However, there is a lack of the information on the effectiveness of orthotic management versus exercise. METHODS: The inclusion criteria recommended by the Scoliosis Research Society (SRS) and the international Society on Scoliosis Orthopedic and Rehabilitation Treatment (SOSORT) were used during enrollment. Eligible patients were randomly assigned to either bracing group or exercise group. Patients in the bracing group were prescribed with a rigid thoracolumbosacral orthosis and requested to wear 23 h/day, while patients in the exercise group were treated with the protocol of the Scientific Exercise Approach to Scoliosis. Data regarding angle of trunk inclination, Cobb angle, shoulder balance, body image, and quality of life (QoL) were collected every 6 months. RESULTS: Twenty-four patients in the bracing group and 29 patients in the exercise group participated in this study. For the intergroup comparison, the bracing group showed better results about the correction of spinal curvature (Cobb angle at the first 12 months of intervention, P = 0.039), scores concerning QoL, especially function (P < 0.001), mental health (P < 0.001), and total score (P < 0.001), were higher than that of the exercise group. The results of body symmetry evaluation did not differ significantly between the two groups. For the intragroup comparison, parameters of spinal curvature (baseline vs. 12-month, P < 0.03 in the exercise group and P < 0.001 in the bracing group), QoL (baseline vs. 12-month, P < 0.001), and TAPS (baseline vs. 12-month, P < 0.033) significantly improved over the studied period. Shoulder balance (baseline vs. 12-month, P < 0.005) showed significant improvement only in the bracing group. CONCLUSION: Both interventions of bracing and exercise showed significant treatment effectiveness on the patients with AIS. Bracing was superior to capture corrections in parameters of spinal curvature and body symmetry, while the QoL, especially in aspect of the functional and psychological status, was significantly better in the exercise group. LEVEL OF EVIDENCE: 1.


Assuntos
Braquetes/tendências , Tratamento Conservador/tendências , Terapia por Exercício/tendências , Exercício Físico , Escoliose/diagnóstico por imagem , Escoliose/terapia , Adolescente , Criança , China/epidemiologia , Tratamento Conservador/métodos , Exercício Físico/fisiologia , Terapia por Exercício/métodos , Feminino , Seguimentos , Humanos , Masculino , Escoliose/epidemiologia , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-28795156

RESUMO

BACKGROUND: Four factors have been reported to affect brace treatment outcome: (1) growth or curve based risk, (2) the in-brace correction, (3) the brace wear quantity, and (4) the brace wear quality. The quality of brace design affects the in-brace correction and comfort which indirectly affects the brace wear quantity and quality. This paper reported the immediate benefits and results on using ultrasound (US) to aid orthotists to design braces for the treatment of scoliosis. METHODS: Thirty-four AIS subjects participated in this study with 17 (2 males, 15 females) in the control group and 17 (2 males, 15 females) in the intervention (US) group. All participants were prescribed full time TLSO, constructed by either of the 2 orthotists in fabrication of spinal braces. For the control group, the Providence brace design system was adopted to design full time braces. For the intervention group, the custom standing Providence brace design system, plus a medical ultrasound system, a custom pressure measurement system and an in-house software were used to assist brace casting. RESULTS: In the control group, 8 of 17 (47%) subjects needed a total of 11 brace adjustments after initial fabrication requiring a total of 28 in-brace radiographs. Three subjects (18%) required a second adjustment. For the US group, only 1 subject (6%) required adjustment. The total number of in-brace radiographs was 18. The p value of the chi-square for requiring brace adjustment was 0.006 which was a statistically significant difference between the two groups. In the intervention group, the immediate in-brace correction as measured from radiographs was 48 ± 17%, and in the control group the first and second in-brace correction was 33 ± 19% and 40 ± 20%, respectively. The unpaired 2 sided Student's t test of the in-brace correction was significantly different between the US and the first follow-up of the control group (p = 0.02), but was not significant after the second brace adjustment (p = 0.22). CONCLUSIONS: The use of the 3D ultrasound system provided a radiation-free method to determine the optimum pressure level and location to assist brace design, resulting in decreased radiation exposure during follow-up brace evaluation, increased the in-brace correction, reduced the patients' visits to both brace adjustment and scoliosis clinics. However, the final outcomes could not be reported yet as some of patients are still under brace treatment. TRIAL REGISTRATION: NCT02996643, retrospectively registered in 16 December 2016.

17.
Ann Biomed Eng ; 44(10): 2874-2886, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27160674

RESUMO

Intraoral ultrasonography uses high-frequency mechanical waves to study dento-periodontium. Besides the advantages of portability and cost-effectiveness, ultrasound technique has no ionizing radiation. Previous studies employed a single transducer or an array of transducer elements, and focused on enamel thickness and distance measurement. This study used a phased array system with a 128-element array transducer to image dento-periodontal tissues. We studied two porcine lower incisors from a 6-month-old piglet using 20-MHz ultrasound. The high-resolution ultrasonographs clearly showed the cross-sectional morphological images of the hard and soft tissues. The investigation used an integration of waveform analysis, travel-time calculation, and wavefield simulation to reveal the nature of the ultrasound data, which makes the study novel. With the assistance of time-distance radio-frequency records, we robustly justified the enamel-dentin interface, dentin-pulp interface, and the cemento-enamel junction. The alveolar crest level, the location of cemento-enamel junction, and the thickness of alveolar crest were measured from the images and compared favorably with those from the cone beam computed tomography with less than 10% difference. This preliminary and fundamental study has reinforced the conclusions from previous studies, that ultrasonography has great potential to become a non-invasive diagnostic imaging tool for quantitative assessment of periodontal structures and better delivery of oral care.


Assuntos
Incisivo/diagnóstico por imagem , Mandíbula/diagnóstico por imagem , Periodonto/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Suínos
18.
Ultrasound Med Biol ; 42(7): 1473-81, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27083978

RESUMO

This study aimed to assess the validity of 3-D ultrasound measurements on the vertebral rotation of adolescent idiopathic scoliosis (AIS) under clinical settings. Thirty curves (mean Cobb angle: 21.7° ± 15.9°) from 16 patients with AIS were recruited. 3-D ultrasound and magnetic resonance imaging scans were performed at the supine position. Each of the two raters measured the apical vertebral rotation using the center of laminae (COL) method in the 3-D ultrasound images and the Aaro-Dahlborn method in the magnetic resonance images. The intra- and inter-reliability of the COL method was demonstrated by the intra-class correlation coefficient (ICC) (both [2, K] >0.9, p < 0.05). The COL method showed no significant difference (p < 0.05) compared with the Aaro-Dahlborn method. Furthermore, the agreement between these two methods was demonstrated by the Bland-Altman method, and high correlation was found (r > 0.9, p < 0.05). These results validated the proposed 3-D ultrasound method in the measurements of vertebral rotation in the patients with AIS.


Assuntos
Imageamento Tridimensional/métodos , Escoliose/diagnóstico por imagem , Coluna Vertebral/anormalidades , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Feminino , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Rotação
19.
Eur Spine J ; 25(10): 3265-3273, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26951170

RESUMO

PURPOSE: This study aimed to investigate the intra- and inter-observer reliability of the axial vertebral rotation (AVR) measurements of adolescent idiopathic scoliosis (AIS) using the center of lamina (COL) method on ultrasound transverse images. METHODS: Three cadaver vertebrae were scanned with 42 AVR configurations by both ultrasound and radiograph. In this in vitro study, four observers measured the AVR using the COL method on ultrasound transverse images and three observers measured the AVR using the Stokes' method on radiographs. In the in vivo study, 13 AIS subjects were recruited. Eighteen spinal curvatures were identified and 48 vertebrae were selected for the AVR measurements. Two observers performed the AVR measurements on both the ultrasound images and radiographs. All measurements were performed twice with 1 week interval apart to reduce memory bias. The intraclass correlation coefficient (ICC), mean absolute differences (MAD), and standard deviation (SD) were used to analyze the intra- and inter-observer reliability of the AVR measurements. The Bland-Altman plot was used to analyze the 95 % limit of the differences between the two methods. RESULTS: The proposed COL method had high intra- and inter-observer reliability on both the in vitro and in vivo studies (ICCs > 0.91, MADs < 1.4°) and agreed well with the experimental setup (ICCs > 0.96, MADs < 2.3°). The COL method showed good agreement with the Stokes' method for the in vitro study (ICC 0.84-0.85, MAD 4.5°-5.0°), while poor agreement for the in vivo study (ICC 0.49-0.54, MAD 2.7°-3.5°). CONCLUSIONS: The pilot study indicated the proposed COL method was a simple and reliable method to evaluate the AVR on ultrasound images. Standardization of the posture during ultrasound scan and taking radiograph is important.


Assuntos
Rotação , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Adolescente , Feminino , Humanos , Técnicas In Vitro , Variações Dependentes do Observador , Projetos Piloto , Radiografia , Reprodutibilidade dos Testes , Escoliose/patologia , Coluna Vertebral/patologia , Ultrassonografia/métodos
20.
Eur Spine J ; 25(2): 495-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26386869

RESUMO

PURPOSE: To determine the reliability of a prognostic curve progression model and the role of the quantity and quality of brace wear for adolescent idiopathic scoliosis (AIS) brace treatment. METHODS: To develop a curve progression model for full-time AIS brace treatment, 20 AIS subjects (Group 1) prescribed full-time thoracolumbar sacral orthosis (TLSO) were monitored and followed for 2 years beyond maturity. The developed curve progression model was: curve progression (in degrees) = 33 + 0.11 × Peterson risk (%) - 0.07 in-brace correction (%) - 0.45 × quality (%) - 0.48 × quantity (%) + 0.0062 × quantity × quality. To validate the model, 40 new (test) subjects (Group 2) who met the same inclusion criteria and used the same type of monitors, were monitored and followed for 2 years after bracing. RESULTS: For the 40 test subjects (Group 2), the average in-brace correction was 40 ± 22 %. The average quantity and quality of the brace wear were 56 ± 19 and 55 ± 17 %, respectively. Twelve subjects (30 %) progressed of which 10 subjects (25 %) required surgery and 28 subjects (70 %) showed no progression. The accuracy of the model to determine which patients would progress was 88 % (35/40) which was better than the Peterson's risk model (68 %; 26/40) alone. Patients who had the combined quantity times the quality over a threshold 43 % had a success treatment rate of 95 %. CONCLUSIONS: This study showed the prognostic model of brace treatment outcome on AIS patients treated with full-time TLSO was reliable. Both the quantity and quality of the brace wear were important factors in achieving successful brace treatment.


Assuntos
Braquetes , Progressão da Doença , Escoliose/terapia , Adolescente , Feminino , Seguimentos , Humanos , Masculino , Monitorização Ambulatorial/instrumentação , Prognóstico , Análise de Regressão , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA