Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39056434

RESUMO

INTRODUCTION: Cerebral Embolic Protection Device (CEPD) captures emboli during Transcatheter Aortic Valve Replacement (TAVR). With recently published pivotal trials and multiple cohort studies reporting new data, there is a need to re-calibrate available statistical evidence. METHODS: A systematic literature search was conducted across databases from inception till February 2023. Dichotomous outcomes were pooled using Odds Ratio (OR), while continuous outcomes were pooled using Standardized Mean Difference (SMD) along with 95% corresponding intervals (95% CIs). RESULTS: Data was included from 17 studies (7 RCTs, 10 cohorts, n = 155,829). Use of CEPD was associated with significantly reduced odds of stroke (OR = 0.60, 95% CI = 0.43-0.85, p = 0.003). There was no significant difference in disabling stroke (p = 0.25), non-disabling stroke (p = 0.72), and 30-day mortality (p = 0.10) between the two groups. There were no significant differences between the two groups for Diffusion-Weighted Magnetic Resonance Imaging (DW-MRI) findings, acute kidney injury, risk of pacemaker implantation life-threatening bleed, major bleed, minor bleed, worsening National Institute of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and vascular complications (p > 0.05). CONCLUSIONS: The use of CEPD during TAVR reduced the incidence of all-stroke (p = 0.003); however, there were no significant differences in any of the other pooled outcomes (p > 0.05). REGISTRATION: The protocol of this meta-analysis was registered with the Open Science framework [https://doi.org/10.17605/OSF.IO/7W564] before data acquisition was started.

3.
Ann Thorac Surg ; 115(2): e33-e35, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35331701

RESUMO

A 71-year-old woman with a history of atrial fibrillation underwent a catheter-based ablation procedure. Months later, she presented with dyspnea and a left-sided pleural effusion. Diagnostic evaluation revealed left-sided pulmonary venous occlusion, with essentially absent left lung perfusion. The patient underwent left pneumonectomy, with left atrial appendage occlusion. Although lobectomy for pulmonary venous occlusion of a single vein after pulmonary vein isolation has been described, this appears to be a novel report of occluded pulmonary venous drainage of an entire lung necessitating pneumonectomy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Pneumopatia Veno-Oclusiva , Feminino , Humanos , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Pneumonectomia/efeitos adversos , Pneumopatia Veno-Oclusiva/diagnóstico por imagem , Pneumopatia Veno-Oclusiva/etiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia
4.
ASAIO J ; 67(4): 392-394, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33769994

RESUMO

A subset of patients with coronavirus disease 2019 (COVID-19) develop profound respiratory failure and are treated via invasive mechanical ventilation (IMV). Of these, a smaller subset has severe gas exchange abnormalities that are refractory to maximal levels of IMV support. Extracorporeal membrane oxygenation (ECMO) has been used successfully in these circumstances. However, using ECMO only after failure of IMV exposes patients to the risks of ventilator-induced lung injury. We report a successful outcome using ECMO in the setting of COVID-19 in the absence of IMV failure in an awake, nonintubated patient. This approach may be beneficial for selected patients with COVID-19.


Assuntos
COVID-19/terapia , Oxigenação por Membrana Extracorpórea , Lesão Pulmonar/etiologia , Respiração Artificial , Insuficiência Respiratória/terapia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , COVID-19/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
J Card Surg ; 36(4): 1563-1565, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33502796

RESUMO

A 66-year-old woman with a history of hypertension, ischemic stroke, and rheumatoid arthritis presented to the hospital with severe angina pectoris and dyspnea and was diagnosed with myocardial infarction (MI). Coronary angiography revealed multisystem coronary artery occlusive disease. Due to refractory myocardial ischemia/evolving MI, emergency coronary artery bypass grafting (CABG) was undertaken. Intraoperative transesophageal echocardiography additionally revealed an apical muscular ventricular septal defect (VSD). Concomitant VSD repair was deferred due to the absence of surface evidence of transmural MI for left ventriculotomy, in the setting of pre-existing severe left ventricular dysfunction. An initial totally percutaneous attempt to close the VSD postoperatively failed. A hybrid surgical/catheter-based VSD closure was performed on postoperative day 4, with a successful outcome. The patient did well postoperatively and currently is alive in good condition. To the best of our knowledge, this is the first report of a staged (post-CABG) and hybrid surgical/catheter-based technique without the utilization of cardiopulmonary bypass.


Assuntos
Comunicação Interventricular , Infarto do Miocárdio , Isquemia Miocárdica , Idoso , Catéteres , Ponte de Artéria Coronária , Feminino , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Resultado do Tratamento
8.
Heart Surg Forum ; 23(6): E837-E844, 2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33234220

RESUMO

BACKGROUND: Suitability for transcatheter aortic valve (AV) implantation (TAVI) is determined by using transthoracic echocardiography (TTE), although left-sided cardiac catheterization (LCC) provides directly measured pressure data. TAVI in awake patients permits simultaneous comparison of TTE and LCC under physiologically relevant left ventricular loading conditions. We hypothesized that clinically important discrepancies between TTE and LCC would be identified. METHODS AND RESULTS: TAVI was performed in 108 awake patients undergoing intra-procedural TTE and LCC between January 1, 2016 and December 31, 2016, based upon pre-procedure TTE data. Intra-procedural assessments simultaneously were performed before and after prosthesis implantation. Based upon mean trans-AV systolic ejection pressure gradient (MSEPG), AS was graded as: mild (<20 mm Hg; grade 1), moderate (20 - <40 mm Hg; grade 2), or severe (≥40 mm Hg; grade 3). In 79 of the 108 (73.1%) patients, intra-procedural TTE and LCC assessments were concordant. In 2 of the 108 (1.9%) patients, TTE overestimated AS severity by ≥1 grade. In 27 of the 108 (25.0%) patients, TTE underestimated AS severity by ≥1 grade. In total, AS severity reclassification occurred in 29 (26.9%) patients. Overall, TTE underestimated MSEPG by 8.9 ± 1.2 mm Hg (TTE MSEPG versus LCC MSEPG; P < .001). CONCLUSION: Current TTE criteria appear to frequently and importantly underestimate AS severity. Because decision-making regarding TAVI often exclusively is based upon TTE data, these findings suggest either a continued role for LCC in the diagnostic assessment of AS in patients who do not meet standard TTE criteria or lowering TTE cutoffs for TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana/métodos , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Vigília , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/classificação , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia Tridimensional/métodos , Seguimentos , Humanos , Período Intraoperatório , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Função Ventricular Esquerda/fisiologia
9.
Am J Cardiol ; 132: 114-118, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32798041

RESUMO

Routine preprocedural chest and abdomen computed tomography is done prior to transcatheter aortic valve implantation (TAVI), which, in turn, have led to the discovery of radiographic potentially malignant incidental masses (pMIM). It is largely unknown whether pMIM impact the outcomes of patients undergoing TAVI. In this retrospective cohort study from a single center, 1,081 patients underwent TAVI from 2012 to 2016, who had available computed tomographies, survived the index hospitalization, and also had 1 year follow-up data for review. Machine learning (backward propagation neural network)-augmented multivariable regression for mortality by pMIM was conducted. In this cohort of 1,081 patients, the mean age was 79.1 (± 9.0), 48.8% were females, 16.8% had a history of prior malignancy, and 21.1% had pMIM. One-year mortality for the entire cohort was 12.6%. The most common prior malignancies were prostate, breast, and lymphoma and the most common pMIM were present in the lung, kidneys, and thyroid. In a fully adjusted regression analysis, neither prior malignancy nor pMIM increased mortality odds. However, having both was associated with a higher 1-year mortality (odds ratio 4.02, 95% confidence interval 1.50 to 10.73, p = 0.006). In conclusion, presence of pMIM alone was not associated with an increased 1-year mortality among patients undergoing TAVI. However, the presence of pMIM and a history of prior malignancy was associated with a significant increase in 1-year mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Achados Incidentais , Neoplasias/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Neoplasias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Estados Unidos/epidemiologia
11.
Circ Heart Fail ; 13(5): e007175, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32357074

RESUMO

The severe acute respiratory syndrome-CoV-2 is an emerging viral pathogen responsible for the global coronavirus disease 2019 pandemic resulting in significant human morbidity and mortality. Based on preliminary clinical reports, hypoxic respiratory failure complicated by acute respiratory distress syndrome is the leading cause of death. Further, septic shock, late-onset cardiac dysfunction, and multiorgan system failure are also described as contributors to overall mortality. Although extracorporeal membrane oxygenation and other modalities of mechanical cardiopulmonary support are increasingly being utilized in the treatment of respiratory and circulatory failure refractory to conventional management, their role and efficacy as support modalities in the present pandemic are unclear. We review the rapidly changing epidemiology, pathophysiology, emerging therapy, and clinical outcomes of coronavirus disease 2019; and based on these data and previous experience with artificial cardiopulmonary support strategies, particularly in the setting of infectious diseases, provide consensus recommendations from American Society for Artificial Internal Organs. Of note, this is a living document, which will be updated periodically, as additional information and understanding emerges.


Assuntos
Betacoronavirus , Infecções por Coronavirus/terapia , Coração , Pulmão , Pneumonia Viral/terapia , COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Sociedades Médicas
12.
ASAIO J ; 66(6): 588-598, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32358232

RESUMO

The severe acute respiratory syndrome (SARS)-CoV-2 is an emerging viral pathogen responsible for the global coronavirus disease 2019 (COVID)-19 pandemic resulting in significant human morbidity and mortality. Based on preliminary clinical reports, hypoxic respiratory failure complicated by acute respiratory distress syndrome is the leading cause of death. Further, septic shock, late-onset cardiac dysfunction, and multiorgan system failure are also described as contributors to overall mortality. Although extracorporeal membrane oxygenation and other modalities of mechanical cardiopulmonary support are increasingly being utilized in the treatment of respiratory and circulatory failure refractory to conventional management, their role and efficacy as support modalities in the present pandemic are unclear. We review the rapidly changing epidemiology, pathophysiology, emerging therapy, and clinical outcomes of COVID-19; and based on these data and previous experience with artificial cardiopulmonary support strategies, particularly in the setting of infectious diseases, provide consensus recommendations from ASAIO. Of note, this is a "living document," which will be updated periodically, as additional information and understanding emerges.


Assuntos
Betacoronavirus , Infecções por Coronavirus/terapia , Cardiopatias/terapia , Pneumonia Viral/terapia , Insuficiência Respiratória/terapia , Animais , COVID-19 , Oxigenação por Membrana Extracorpórea , Humanos , Pandemias , SARS-CoV-2
13.
Cardiovasc Revasc Med ; 21(2): 149-154, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31178348

RESUMO

BACKGROUND: The impact of procedure location on clinical outcomes after TAVR remains unclear. We aimed to compare short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) in the catheterization laboratory (CATH) versus surgical operating room (OR). METHODS: A retrospective review of 63,581 trans-femoral TAVR patients using balloon-expandable valves from 2015 to 2018 were captured utilizing the TVT Registry. Propensity score matching was performed using 24 covariates resulting in 2 risk-adjusted groups. Patients were further stratified by STS Risk Score with outcomes compared. RESULTS: Propensity score matching resulted in 24,160 risk-matched CATH and OR patient pairs. Short-term clinical outcomes including all-cause mortality, stroke, major vascular complications, life-threatening bleeding, and new dialysis were similar between CATH and OR (p = all ns). There was no difference in conversion to open heart surgery between CATH and OR with both occurring at a very low rate (0.4% vs. 0.5%, p = 0.07). Moreover, the 30-day survival post-conversion was similar whether TAVR was performed in CATH versus OR (43.3% and 49.7%, p = 0.28). When stratified by STS Risk Score, there was no difference in conversion to surgery or 30-day mortality in low and intermediate risk patients between CATH and OR. For high risk patients, however, conversion to surgery was lower in CATH vs. OR (0.2% vs. 0.4%, p = 0.04) with no difference in 30-day survival (46% vs. 43%, p = 0.94). CONCLUSIONS: Procedure location has minimal impact on TAVR procedural and 30-day outcomes with a very low conversion to open surgery rate between CATH versus OR for low, intermediate, and high-risk patients.


Assuntos
Valvuloplastia com Balão , Cateterismo Cardíaco , Laboratórios Hospitalares , Salas Cirúrgicas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Conversão para Cirurgia Aberta , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
17.
Innovations (Phila) ; 14(4): 365-368, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31185777

RESUMO

Reoperative aortic valve replacement is associated with increased morbidity. Valve-in-valve transcatheter aortic valve replacement offers a less invasive alternative to traditional reoperation. However, cases of valve failure after valve-in-valve transcatheter aortic valve replacement represent a complex surgical challenge. We present a case requiring a complex reoperative aortic valve replacement due to structural valve deterioration after multiple previous valve-in-valve transcatheter aortic valve replacements. We performed removal of 3 previous valve-in-valve transcatheter aortic valves, bioprosthetic leaflet excision, and intentional bioprosthetic fracture under direct vision for annular enlargement. This facilitated direct insertion of a new transcatheter aortic valve for expedient and successful management of recurrent aortic stenosis in a very high-risk patient. Creative use of leaflet excision, intentional bioprosthetic fracture, and insertion of a new transcatheter aortic valve under direct vision, proved efficient and successful in a high-risk patient with few surgical options.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Falha de Prótese , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Esternotomia , Substituição da Valva Aórtica Transcateter
18.
J Thorac Cardiovasc Surg ; 158(5): 1317-1328.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30857820

RESUMO

OBJECTIVE: Valve-in-valve transcatheter aortic valve replacement (VIV TAVR) can result in high residual gradients that are associated with increased mortality. Bioprosthetic valve fracture (BVF) has been shown to improve residual gradients following VIV TAVR; however, factors influencing the results of BVF have not been studied. METHODS: BVF was performed in 75 patients at 21 centers. Hierarchical multiple linear regression was performed to identify variables that were associated with lower final transvalvular gradient. RESULTS: Surgical valves with a median true internal diameter of 18.5 mm (interquartile range, 17.0-20.5 mm) were treated with VIV TAVR in conjunction with BVF using balloon-expandable (n = 43) or self-expanding (n = 32) transcatheter heart valves with a median size of 23 mm (interquartile range, 23-23 mm). There were no aortic root disruptions, coronary occlusions, or new pacemakers; in-hospital or 30-day mortality was 2.6% (2 out of 75). Final mean transvalvular gradient was 9.2 ± 6.3 mm Hg, but was significantly lower when BVF was performed after VIV TAVR compared with BVF first (8.1 ± 4.8 mm Hg vs 16.9 ± 10.1 mm Hg; P < .001). After adjusting for timing of BVF (ie, before or after VIV TAVR), transcatheter heart valve size/type, surgical valve mode of failure, true internal diameter, and baseline gradient and BVF balloon size, performing BVF after VIV TAVR (P < .001) and using a larger BVF balloon (P = .038) were the only independent predictors of lower final mean gradient. CONCLUSIONS: BVF can be performed safely and results in reduced residual transvalvular gradients. Performing BVF after VIV TAVR and using larger balloon appears to achieve the best hemodynamic results.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Bioprótese , Próteses Valvulares Cardíacas , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Bioprótese/estatística & dados numéricos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Hemodinâmica , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Desenho de Prótese , Falha de Prótese , Reoperação/instrumentação , Reoperação/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos
20.
J Nucl Med ; 60(3): 410-417, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30115688

RESUMO

Because randomized coronary revascularization trials in stable coronary artery disease (CAD) have shown no reduced myocardial infarction (MI) or mortality, the threshold of quantitative myocardial perfusion severity was analyzed for association with reduced death, MI, or stroke after revascularization within 90 d after PET. Methods: In a prospective long-term cohort of stable CAD, regional, artery-specific, quantitative myocardial perfusion by PET, coronary revascularization within 90 d after PET, and all-cause death, MI, and stroke (DMS) at 9-y follow-up (mean ± SD, 3.0 ± 2.3 y) were analyzed by multivariate Cox regression models and propensity analysis. Results: For 3,774 sequential rest-stress PET scans, regional, artery-specific, severely reduced coronary flow capacity (CFC) (coronary flow reserve ≤ 1.27 and stress perfusion ≤ 0.83 cc/min/g) associated with 60% increased hazard ratio for major adverse cardiovascular events and 30% increased hazard of DMS that was significantly reduced by 54% associated with revascularization within 90 d after PET (P = 0.0369), compared with moderate or mild CFC, coronary flow reserve, other PET metrics or medical treatment alone. Depending on severity threshold for statistical certainty, up to 19% of this clinical cohort had CFC severity associated with reduced DMS after revascularization. Conclusion: CFC by PET provides objective, regional, artery-specific, size-severity physiologic quantification of CAD severity associated with high risk of DMS that is significantly reduced after revascularization within 90 d after PET, an association not seen for moderate to mild perfusion abnormalities or medical treatment alone.


Assuntos
Artérias/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Circulação Coronária , Infarto do Miocárdio/complicações , Revascularização Miocárdica , Tomografia por Emissão de Pósitrons , Idoso , Artérias/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Especificidade de Órgãos , Estresse Fisiológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA