Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Chem ; 12: 1407754, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38915903

RESUMO

Ophthalmic and many systemic diseases may damage the eyes, resulting in changes in the composition and content of biomolecules in ocular biofluids such as aqueous humor and tear. Therefore, the biomolecules in biofluids are potential biomarkers to reveal pathological processes and diagnose diseases. Raman spectroscopy is a non-invasive, label-free, and cost-effective technique to provide chemical bond information of biomolecules and shows great potential in the detection of ocular biofluids. This review demonstrates the applications of Raman spectroscopy technology in detecting biochemical components in aqueous humor and tear, then summarizes the current problems encountered for clinical applications of Raman spectroscopy and looks forward to possible approaches to overcome technical bottlenecks. This work may provide a reference for wider applications of Raman spectroscopy in biofluid detection and inspire new ideas for the diagnosis of diseases using ocular biofluids.

2.
Sensors (Basel) ; 23(10)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37430664

RESUMO

Human activity recognition (HAR) is becoming increasingly important, especially with the growing number of elderly people living at home. However, most sensors, such as cameras, do not perform well in low-light environments. To address this issue, we designed a HAR system that combines a camera and a millimeter wave radar, taking advantage of each sensor and a fusion algorithm to distinguish between confusing human activities and to improve accuracy in low-light settings. To extract the spatial and temporal features contained in the multisensor fusion data, we designed an improved CNN-LSTM model. In addition, three data fusion algorithms were studied and investigated. Compared to camera data in low-light environments, the fusion data significantly improved the HAR accuracy by at least 26.68%, 19.87%, and 21.92% under the data level fusion algorithm, feature level fusion algorithm, and decision level fusion algorithm, respectively. Moreover, the data level fusion algorithm also resulted in a reduction of the best misclassification rate to 2%~6%. These findings suggest that the proposed system has the potential to enhance the accuracy of HAR in low-light environments and to decrease human activity misclassification rates.


Assuntos
Algoritmos , Atividades Humanas , Idoso , Humanos , Radar , Reconhecimento Psicológico
3.
Sensors (Basel) ; 22(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35897997

RESUMO

Noise is a common problem in wearable electrocardiogram (ECG) monitoring systems because the presence of noise can corrupt the ECG waveform causing inaccurate signal interpretation. By comparison with electromagnetic interference and its minimization, the reduction of motion artifact is more difficult and challenging because its time-frequency characteristics are unpredictable. Based on the characteristics of motion artifacts, this work uses adaptive filtering, a specially designed ECG device, and an Impedance Pneumography (IP) data acquisition system to combat motion artifacts. The newly designed ECG-IP acquisition system maximizes signal correlation by measuring both ECG and IP signals simultaneously using the same pair of electrodes. Signal comparison investigations between ECG and IP signals under five different body motions were carried out, and the Pearson Correlation Coefficient |r| was higher than 0.6 in all cases, indicating a good correlation. To optimize the performance of adaptive motion artifact reduction, the IP signal was filtered to a 5 Hz low-pass filter and then fed into a Recursive Least Squares (RLS) adaptive filter as a reference input signal. The performance of the proposed motion artifact reduction method was evaluated subjectively and objectively, and the results proved that the method could suppress the motion artifacts and achieve minimal distortion to the denoised ECG signal.


Assuntos
Artefatos , Dispositivos Eletrônicos Vestíveis , Algoritmos , Impedância Elétrica , Eletrocardiografia/métodos , Movimento (Física) , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA