Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Imaging ; 8(9)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36135392

RESUMO

If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.

2.
J Synchrotron Radiat ; 29(Pt 3): 794-806, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511012

RESUMO

The advent of hard X-ray free-electron lasers enables nanoscopic X-ray imaging with sub-picosecond temporal resolution. X-ray grating interferometry offers a phase-sensitive full-field imaging technique where the phase retrieval can be carried out from a single exposure alone. Thus, the method is attractive for imaging applications at X-ray free-electron lasers where intrinsic pulse-to-pulse fluctuations pose a major challenge. In this work, the single-exposure phase imaging capabilities of grating interferometry are characterized by an implementation at the I13-1 beamline of Diamond Light Source (Oxfordshire, UK). For comparison purposes, propagation-based phase contrast imaging was also performed at the same instrument. The characterization is carried out in terms of the quantitativeness and the contrast-to-noise ratio of the phase reconstructions as well as via the achievable spatial resolution. By using a statistical image reconstruction scheme, previous limitations of grating interferometry regarding the spatial resolution can be mitigated as well as the experimental applicability of the technique.

3.
J Imaging ; 7(9)2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34564104

RESUMO

X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.

4.
Sci Rep ; 11(1): 4574, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33633184

RESUMO

Detailed imaging of the three-dimensionally complex architecture of xylary plants is important for studying biological and mechanical functions of woody plants. Apart from common two-dimensional microscopy, X-ray micro-computed tomography has been established as a three-dimensional (3D) imaging method for studying the hydraulic function of wooden plants. However, this X-ray imaging method can barely reach the resolution needed to see the minute structures (e.g. pit membrane). To complement the xylem structure with 3D views at the nanoscale level, X-ray near-field nano-holotomography (NFH) was applied to analyze the wood species Pinus sylvestris and Fagus sylvatica. The demanded small specimens required focused ion beam (FIB) application. The FIB milling, however, influenced the image quality through gallium implantation on the cell-wall surfaces. The measurements indicated that NFH is appropriate for imaging wood at nanometric resolution. With a 26 nm voxel pitch, the structure of the cell-wall surface in Pinus sylvestris could be visualized in genuine detail. In wood of Fagus sylvatica, the structure of a pit pair, including the pit membrane, between two neighboring fibrous cells could be traced tomographically.

5.
Opt Express ; 28(9): 13553-13568, 2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-32403827

RESUMO

The combination of grating-based phase-contrast imaging with X-ray microscopy can result in a complicated image formation. Generally, transverse shifts of the interference fringes are nonlinearly dependent on phase differences of the measured wave front. We present an iterative reconstruction scheme based on a regularized maximum likelihood cost function that fully takes this dependency into account. The scheme is validated by numerical simulations. It is particularly advantageous at low photon numbers and when the premises for deconvolution-based reconstructions are not met. Our reconstruction scheme hence enables a broader applicability of X-ray grating interferometry in imaging and wave front sensing.

6.
J Imaging ; 6(7)2020 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-34460656

RESUMO

For imaging events of extremely short duration, like shock waves or explosions, it is necessary to be able to image the object with a single-shot exposure. A suitable setup is given by a laser-induced X-ray source such as the one that can be found at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) in Darmstadt (Society for Heavy Ion Research), Germany. There, it is possible to direct a pulse from the high-energy laser Petawatt High Energy Laser for Heavy Ion eXperiments (PHELIX) on a tungsten wire to generate a picosecond polychromatic X-ray pulse, called backlighter. For grating-based single-shot phase-contrast imaging of shock waves or exploding wires, it is important to know the weighted mean energy of the X-ray spectrum for choosing a suitable setup. In propagation-based phase-contrast imaging the knowledge of the weighted mean energy is necessary to be able to reconstruct quantitative phase images of unknown objects. Hence, we developed a method to evaluate the weighted mean energy of the X-ray backlighter spectrum using propagation-based phase-contrast images. In a first step wave-field simulations are performed to verify the results. Furthermore, our evaluation is cross-checked with monochromatic synchrotron measurements with known energy at Diamond Light Source (DLS, Didcot, UK) for proof of concepts.

7.
Sci Rep ; 9(1): 9216, 2019 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-31239499

RESUMO

The X-ray dark-field signal can be measured with a grating-based Talbot-Lau interferometer. It measures small angle scattering of micrometer-sized oriented structures. Interestingly, the signal is a function not only of the material, but also of the relative orientation of the sample, the X-ray beam direction, and the direction of the interferometer sensitivity. This property is very interesting for potential tomographically reconstructing structures below the imaging resolution. However, tomographic reconstruction itself is a substantial challenge. A key step of the reconstruction algorithm is the inversion of a forward projection model. In this work, we propose a very general 3-D projection model. We derive the projection model under the assumption that the observed scatter distribution has a Gaussian shape. We theoretically show the consistency of our model with existing, more constrained 2-D models. Furthermore, we experimentally show the compatibility of our model with simulations and real dark-field measurements. We believe that this 3-D projection model is an important step towards more flexible trajectories and, by extension, dark-field imaging protocols that are much better applicable in practice.

8.
Sci Rep ; 9(1): 4199, 2019 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-30862865

RESUMO

Compared to conventional attenuation x-ray radiographic imaging, the x-ray Talbot-Lau technique provides further information about the scattering and the refractive properties of the object in the beam path. Hence, this additional information should improve the diagnostic process concerning medical applications and non-destructive testing. Nevertheless, until now, due to grating fabrication process, Talbot-Lau imaging suffers from small grating sizes (70 mm diameter). This leads to long acquisition times for imaging large objects. Stitching the gratings is one solution. Another one consists of scanning Talbot-Lau setups. In this publication, we present a compact and very fast scanning setup which enables imaging of large samples. With this setup a maximal scanning velocity of 71.7 mm/s is possible. A resolution of 4.1 lines/mm can be achieved. No complex alignment procedures are necessary while the field of view comprises 17.5 × 150 cm2. An improved reconstruction algorithm concerning the scanning approach, which increases robustness with respect to mechanical instabilities, has been developed and is presented. The resolution of the setup in dependence of the scanning velocity is evaluated. The setup imaging qualities are demonstrated using a human knee ex-vivo as an example for a high absorbing human sample.

9.
Phys Med Biol ; 64(6): 065013, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30731447

RESUMO

X-ray dark-field imaging is a promising technique for lung diagnosis. Due to the alveolar structure of lung tissue, a higher contrast is obtained by the dark-field image compared to the attenuation image. Animal studies indicate an enhancement regarding the detection of lung diseases in early stages. In this publication, we focus on the influence of different Talbot-Lau interferometer specifications while maintaining the x-ray source, sample magnification and detector system. By imaging the same porcine lung with three different grating sets, we analyze the contrast-to-noise ratio of the obtained dark-field images with respect to visibility and correlation length. We demonstrate that relatively large grating periods of the phase and of the analyzer grating are sufficient for high quality lung imaging at reasonable dose levels.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Interferometria/métodos , Pulmão/diagnóstico por imagem , Animais , Interferometria/instrumentação , Suínos , Raios X
10.
Int J Comput Assist Radiol Surg ; 14(1): 3-10, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30349975

RESUMO

PURPOSE: Two phase gratings in an X-ray grating interferometers can solve several technical challenges for clinical use of X-ray phase contrast. In this work, we adapt and evaluate this setup design to clinical X-ray sources and detectors in a simulation study. METHODS: For a given set of gratings, we optimize the remaining parameter space of a dual-phase grating setup using a numerical wave front simulation. The simulation results are validated with experimentally obtained visibility measurements on a setup with a microfocus tube and a clinical X-ray detector. We then confirm by simulation that the Lau condition for the [Formula: see text] grating also holds for two phase gratings. Furthermore, we use a [Formula: see text] grating with a fixed period to search for periods of matching phase grating configurations. RESULTS: Simulated and experimental visibilities agree very well. We show that the Lau condition for a dual-phase grating setup requires the interference patterns of the first phase grating to constructively overlay at the second phase grating. Furthermore, a total of three setup variants for given [Formula: see text] periods were designed with the simulation, resulting in visibilities between 4.5 and 9.1%. CONCLUSION: Dual-phase gratings can be used and optimized for a medical X-ray source and detector. The obtained visibilities are somewhat lower than for other Talbot-Lau interferometers and are a tradeoff between setup length and spatial resolution (or additional phase stepping, respectively). However, these disadvantage appears minor compared to the overall better photon statistics, and the fact that dual-phase grating setups can be expected to scale to higher X-ray energies.


Assuntos
Interferometria , Radiografia/métodos , Simulação por Computador , Humanos , Raios X
11.
Phys Med Biol ; 63(18): 185010, 2018 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-30117437

RESUMO

Talbot-Lau x-ray imaging provides additionally to the conventional attenuation image, two further images: the differential phase-contrast image which is especially sensitive to differences in refractive properties and the dark-field image which is showing the x-ray scattering properties of the object. Thus, in the dark-field image sub-pixeled object information can be observed. As it has been shown in recent studies, this is of special interest for lung imaging. Changes in the alveoli structure, which are in the size of one detector pixel, can be seen in the dark-field images. A fast acquisition process is crucial to avoid motion artifacts due to heartbeat and breathing of the patient. Using moiré imaging the images can be acquired with a single-shot exposure. Nevertheless, the spatial resolution is reduced compared to the phase-stepping acquisition. We evaluate the results of both imaging techniques towards their feasibility in clinical routine. Furthermore, we analyse the influence of artificial linear object movement on the image quality, in order to simulate the heartbeat of a patient.


Assuntos
Interferometria/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia/métodos , Animais , Interferometria/instrumentação , Movimento , Radiografia/instrumentação , Suínos , Raios X
12.
Strahlenther Onkol ; 184(6): 307-12, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18535806

RESUMO

PURPOSE: To compare two irradiation techniques for whole breast irradiation: tangential wedged beams (WT) versus "open" fields (without wedges) with forward planned segments (ST). PATIENTS AND METHODS: For 20 patients two comparative 3-D plans were defined using Pinnacle P3D and analyzed with respect to dose, dose homogeneity in the target volume, and scattered dose to organs at risk. The plans of six patients were reproduced in an Alderson phantom. Measurements were performed in the planning target volume (PTV), contralateral breast, lungs, heart, thyroid gland and in mid-pelvis. RESULTS: Dose distribution in the PTV was nearly identical for WT and ST with the exception of D(1). Scattered doses were significantly smaller for ST. In the contralateral breast the doses per 2-Gy fraction were 7.3 cGy +/- 2.1 cGy (WT), and 4.7 cGy +/- 1.9 cGy (ST; p < 0.01). Similar doses were measured for lung and heart. In mid pelvis the largest difference was observed (WT: 1.0 cGy +/- 0.2 cGy, ST: 0.2 cGy +/- 0.1 cGy; p < 0.01). CONCLUSION: Partial volume segments can replace wedges for improved dose coverage and homogeneity in the PTV. The ST causes significantly less scattered dose to extra-target organs. This may have implications for long-term risks after exposure to low radiation doses.


Assuntos
Neoplasias da Mama/radioterapia , Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Mama/efeitos da radiação , Neoplasias da Mama/cirurgia , Estudos de Coortes , Fracionamento da Dose de Radiação , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Mastectomia Segmentar , Pelve/efeitos da radiação , Imagens de Fantasmas , Radiometria , Radioterapia Adjuvante , Estudos Retrospectivos , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA