Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Malar J ; 15: 119, 2016 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-26917250

RESUMO

BACKGROUND: The US FDA recently developed CD3+, a counterfeit detection tool that is based on sample illumination at specific wavelengths of light and visual comparison of suspect sample and packaging materials to an authentic sample. To test performance of the CD3+ in field conditions, a study was conducted in Ghana which compared the CD3+ side-by-side with two existing medicine quality screening technologies-TruScan™ Portable Raman spectrometer and GPHF Minilab(®). METHODS: A total of 84 anti-malarial test samples comprising artemether-lumefantrine tablets and artesunate-amodiaquine tablets were used. The technologies were evaluated for sensitivity in determining counterfeit/substandard (The term counterfeit or falsified is used in this article to refer to medicines that carry a false representation of identity or source or both. The term substandard is used to refer to medicines that do not meet the quality specifications given in the accepted pharmacopeia.) medicines, specificity in determining authentic products, and reliability of the results. Authentic samples obtained from manufacturers were used as reference standards. HPLC analysis data was used as the "gold standard" for decisions regarding a sample being authentic or substandard/counterfeit. RESULTS: CD3+ had a sensitivity of 1.00 in detecting counterfeit/substandard products compared to Minilab (0.79) and TruScan (0.79). CD3+ had a lower specificity (0.53) in determining authentic products compared to the specificities reached by Minilab (0.99) and TruScan (1.00). High sensitivity in this context means that the technology is effective in identifying substandard/counterfeit products whereas the low specificity means that the technique can sometimes mischaracterize good products as substandard/counterfeit. Examination of dosage units only (and not packaging) using CD3+ yielded improved specificity 0.64. When only assessment of sample identification was done, the TruScan provided sensitivity (1.00) and specificity (0.99); and the Minilab provided sensitivity (1.00) and specificity (1.00). All three technologies demonstrated 100 % reliability when used to analyse the same set of samples over 3 days by a single analyst and also when used to determine the same set of samples by three different analysts. Eight of the field samples were confirmed to be counterfeits with no active pharmaceutical ingredient content. All three technologies identified these samples as counterfeits. CONCLUSIONS: The study revealed the relative effectiveness of the technologies as quality control tools. Using a combination of CD3+, with either the Minilab or TruScan, to screen for medicine quality will allow for complete examination of both the dosage units and the packaging to decide whether it is authentic or counterfeit.


Assuntos
Antimaláricos/análise , Antimaláricos/normas , Medicamentos Falsificados/análise , Amodiaquina , Antimaláricos/química , Combinação Arteméter e Lumefantrina , Artemisininas , Cromatografia em Camada Fina/instrumentação , Cromatografia em Camada Fina/métodos , Medicamentos Falsificados/química , Bases de Dados Factuais , Combinação de Medicamentos , Etanolaminas , Fluorenos , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos , Comprimidos/análise , Comprimidos/química , Comprimidos/normas
3.
Am J Trop Med Hyg ; 92(6 Suppl): 68-74, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25897073

RESUMO

Monitoring the quality of medicines plays a crucial role in an integrated medicines quality assurance system. In a publicly available medicines quality database (MQDB), the U.S. Pharmacopeial Convention (USP) reports results of data collected from medicines quality monitoring (MQM) activities spanning the period of 2003-2013 in 17 countries of Africa, Asia, and South America. The MQDB contains information on 15,063 samples collected and tested using Minilab® screening methods and/or pharmacopeial methods. Approximately 71% of the samples reported came from Asia, 23% from Africa, and 6% from South America. The samples collected and tested include mainly antibiotic, antimalarial, and antituberculosis medicines. A total of 848 samples, representing 5.6% of total samples, failed the quality test. The failure proportion per region was 11.5%, 10.4%, and 2.9% for South America, Africa, and Asia, respectively. Eighty-one counterfeit medicines were reported, 86.4% of which were found in Asia and 13.6% in Africa. Additional analysis of the data shows the distribution of poor-quality medicines per region and by therapeutic indication as well as possible trends of counterfeit medicines.


Assuntos
Antibacterianos/normas , Antimaláricos/normas , Antituberculosos/normas , Preparações Farmacêuticas/normas , África , Antimaláricos/química , Antituberculosos/química , Ásia , Medicamentos Falsificados , Bases de Dados Factuais , América do Sul , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA