RESUMO
BACKGROUND: Tau-PET is a diagnostic tool with high sensitivity and specificity for discriminating Alzheimer's disease (AD) dementia from other neurodegenerative disorders in well-controlled research environments. The role of tau-PET in real-world clinical practice, however, remains to be established. The aim of the TAP-TAU study is therefore to investigate the impact of tau-PET in clinical practice. METHODS: TAP-TAU is a prospective, longitudinal multi-center study in 300 patients (≥ 50 years old) with mild cognitive impairment or mild dementia across five Dutch memory clinics. Patients are eligible if diagnostic certainty is < 85% after routine dementia screening and if the differential diagnosis includes AD. More specifically, we will include patients who (i) are suspected of having mixed pathology (e.g., AD and vascular pathology), (ii) have an atypical clinical presentation, and/or (iii) show conflicting or inconclusive outcomes on other tests (e.g., magnetic resonance imaging or cerebrospinal fluid). Participants will undergo a [18F]flortaucipir tau-PET scan, blood-based biomarker sampling, and fill out questionnaires on patient reported outcomes and experiences. The primary outcomes are change (pre- versus post- tau-PET) in diagnosis, diagnostic certainty, patient management and patient anxiety and uncertainty. Secondary outcome measures are head-to-head comparisons between tau-PET and less invasive and lower cost diagnostic tools such as novel blood-based biomarkers and artificial intelligence-based classifiers. RESULTS: TAP-TAU has been approved by the Medical Ethics Committee of the Amsterdam UMC. The first participant is expected to be included in October 2024. CONCLUSIONS: In TAP-TAU, we will investigate the added clinical value of tau-PET in a real-world clinical setting, including memory clinic patients with diagnostic uncertainty after routine work-up. Findings of our study may contribute to recommendations regarding which patients would benefit most from assessment with tau-PET. This study is timely in the dawning era of disease modifying treatments as an accurate etiological diagnosis becomes increasingly important. TRIAL REGISTRATION: This trial is registered and authorized on December 21st, 2023 in EU Clinical Trials with registration number 2023-505430-10-00.
Assuntos
Disfunção Cognitiva , Tomografia por Emissão de Pósitrons , Proteínas tau , Humanos , Proteínas tau/líquido cefalorraquidiano , Proteínas tau/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Feminino , Estudos Prospectivos , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico , Estudos Longitudinais , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/diagnóstico , Pessoa de Meia-Idade , Masculino , Idoso , Estudos de Coortes , Biomarcadores/líquido cefalorraquidiano , Países BaixosRESUMO
The light-induced photocycloaddition of 9,10-phenanthrenequinone (PQ) with electron-rich alkenes (ERA), known as the PQ-ERA reaction, is a highly attractive photoclick reaction characterized by its operational simplicity and high biocompatibility. One essential aspect of photoclick reactions is their high rate, however the limited solubility of PQs often requires the use of a co-solvent. Evaluating the effect of different co-solvents on the PQ-ERA reaction and their influence on the reaction rate, we discovered that sulfur-containing compounds, in particular the frequently used solubilizing co-solvent DMSO, quench the triplet state of the PQ. These experimental results, supported by nanosecond-microsecond and ultrafast transient absorption data, show that even minimal amounts of DMSO result in a decreased lifetime of the reactive triplet state, essential for the photoclick reaction. Without DMSO as co-solvent, exceptionally high photoreaction quantum yields ( Φ P up to 93% with only 1 equivalent ERA) and complete conversion in seconds can be achieved. With these outstanding efficiencies, the PQ-ERA reaction can be used without excess ERA and at low light intensities, facilitating photoclick transformations in various future applications.
RESUMO
Adenosine triphosphate binding cassette (ABC) transporters are a broad family of membrane protein complexes that use energy to transport molecules across cells and/or intracellular organelle lipid membranes. Many drugs used to treat cardiac diseases have an affinity for these transporters. Among others, P-glycoprotein (P-gp) plays an essential role in regulating drug concentrations that reach cardiac tissue and therefore contribute to cardiotoxicity. As a molecular imaging modality, positron emission tomography (PET) has emerged as a viable technique to investigate the function of P-gp in organs and tissues. Using PET imaging to evaluate cardiac P-gp function provides new insights for drug development and improves the precise use of medications. Nevertheless, information in this field is limited. In this review, we aim to examine the current applications of ABC transporter PET imaging and its tracers in the heart, with a specific emphasis on P-gp. Furthermore, the opportunities and challenges in this novel field will be discussed.
RESUMO
INTRODUCTION: P-glycoprotein (P-gp) is one of the most studied efflux transporters at the blood-brain barrier. It plays an important role in brain homeostasis by protecting the brain from a variety of endogenous and exogeneous substances. Changes in P-gp function are associated both with the onset of neuropsychiatric diseases, including Alzheimer's disease and Parkinson's disease, and with drug-resistance, for example in treatment-resistant depression. The most widely used approach to measure P-gp function in vivo is (R)-[11C]verapamil PET. (R)-[11C]verapamil is, however, an avid P-gp substrate, which complicates the use of this tracer to measure an increase in P-gp function as its baseline uptake is already very low. [18F]MC225 was developed to measure both increases and decreases in P-gp function. AIM: The aim of this study was (1) to identify the pharmacokinetic model that best describes [18F]MC225 kinetics in the human brain and (2) to determine test-retest variability. METHODS: Five (2 male, 3 female) of fourteen healthy subjects (8 male, 6 female, age 67 ± 5 years) were scanned twice (injected dose 201 ± 47 MBq) with a minimum interval of 2 weeks between scans. Each scanning session consisted of a 60-min dynamic [18F]MC225 scan with continuous arterial sampling. Whole brain grey matter data were fitted to a single tissue compartment model, and to reversible and irreversible two tissue-compartment models to obtain various outcome parameters (in particular the volume of distribution (VT), Ki, and the rate constants K1 and k2). In addition, a reversible two-tissue compartment model with fixed k3/k4 was included. The preferred model was selected based on the weighted Akaike Information Criterion (AIC) score. Test-retest variability (TRTV) was determined to assess reproducibility. RESULTS: Sixty minutes post-injection, the parent fraction was 63.8 ± 4.0%. The reversible two tissue compartment model corrected for plasma metabolites with an estimated blood volume (VB) showed the highest AIC weight score of 34.3 ± 17.6%. The TRVT of the VT for [18F]MC225 PET scans was 28.3 ± 20.4% for the whole brain grey matter region using this preferred model. CONCLUSION: [18F]MC225 VT, derived using a reversible two-tissue compartment model, is the preferred parameter to describe P-gp function in the human BBB. This outcome parameter has an average test-retest variability of 28%. TRIAL REGISTRATION: EudraCT 2020-001564-28 . Registered 25 May 2020.
Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Barreira Hematoencefálica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Barreira Hematoencefálica/diagnóstico por imagem , Barreira Hematoencefálica/metabolismo , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Tomografia por Emissão de Pósitrons , Verapamil , Compostos Radiofarmacêuticos/farmacocinéticaRESUMO
Imaging water pathways in the human body provides an excellent way of measuring accurately the blood flow directed to different organs. This makes it a powerful diagnostic tool for a wide range of diseases that are related to perfusion and oxygenation. Although water PET has a long history, its true potential has not made it into regular clinical practice. The article highlights the potential of water PET in molecular imaging and suggests its prospective role in becoming an essential tool for the 21st century precision medicine in different domains ranging from preclinical to clinical research and practice. The recent technical advances in high-sensitivity PET imaging can play a key accelerating role in empowering this technique, though there are still several challenges to overcome.
RESUMO
Background and purpose: Previous pre-clinical research using [18F]FDG-PET has shown that whole-brain photon-based radiotherapy can affect brain glucose metabolism. This study, aimed to investigate how these findings translate into regional changes in brain [18F]FDG uptake in patients with head and neck cancer treated with intensity-modulated proton therapy (IMPT). Materials and methods: Twenty-three head and neck cancer patients treated with IMPT and available [18F]FDG scans before and at 3 months follow-up were retrospectively evaluated. Regional assessment of the [18F]FDG standardized uptake value (SUV) parameters and radiation dose in the left (L) and right (R) hippocampi, L and R occipital lobes, cerebellum, temporal lobe, L and R parietal lobes and frontal lobe were evaluated to understand the relationship between regional changes in SUV metrics and radiation dose. Results: Three months after IMPT, [18F]FDG brain uptake calculated using SUVmean and SUVmax, was significantly higher than that before IMPT. The absolute SUVmean after IMPT was significantly higher than before IMPT in seven regions of the brain (p ≤ 0.01), except for the R (p = 0.11) and L (p = 0.15) hippocampi. Absolute and relative changes were variably correlated with the regional maximum and mean doses received in most of the brain regions. Conclusion: Our findings suggest that 3 months after completion of IMPT for head and neck cancer, significant increases in the uptake of [18F]FDG (reflected by SUVmean and SUVmax) can be detected in several individual key brain regions, and when evaluated jointly, it shows a negative correlation with the mean dose. Future studies are needed to assess whether and how these results could be used for the early identification of patients at risk for adverse cognitive effects of radiation doses in non-tumor tissues.
RESUMO
The oral route is the most widely used and preferable way of drug administration. Several pharmacokinetic processes play a role in the distribution of administered drugs. Therefore, accurate quantification of absorption, distribution, metabolism, excretion, and characterisation of drug kinetics after oral administration is extremely important for developing new human drugs. In vivo methods, such as gamma-scintigraphy, magnetic resonance imaging (MRI), and positron emission tomography (PET), have been used to analyse gastrointestinal tract (GIT) absorption behaviour. This scoping review provides an overview of PET studies that used oral tracer administration. A systematic literature search was performed using PubMed, EMBASE, Scopus, Science Direct, and Web of Science databases. Extensive variation between these studies was seen concerning acquisition protocols, quantification methods, and pharmacokinetic outcome parameters. Studies in humans indicate that it takes 10 to 30 min for the tracer to be in the intestine and about 100 min to reach its maximum concentration in the brain. In rodent studies, different pharmacokinetic parameters for the brain, blood, and GIT were estimated, showing the potential of PET to measure the absorption and distribution of drugs and pharmaceuticals non-invasively. Finally, regarding radiation protection, oral administration has a higher absorbed dose in GIT and, consequently, a higher effective dose. However, with the recent introduction of Long Axial Field of View (LAFOV) PET scanners, it is possible to reduce the administered dose, making oral administration feasible for routine clinical studies.
Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Humanos , Encéfalo/diagnóstico por imagem , Administração Oral , Trato Gastrointestinal/diagnóstico por imagemRESUMO
Pharmacokinetic modelling with arterial sampling is the gold standard for analysing dynamic PET data of the brain. However, the invasive character of arterial sampling prevents its widespread clinical application. Several methods have been developed to avoid arterial sampling, in particular reference region methods. Unfortunately, for some tracers or diseases, no suitable reference region can be defined. For these cases, other potentially non-invasive approaches have been proposed: (1) a population based input function (PBIF), (2) an image derived input function (IDIF), or (3) simultaneous estimation of the input function (SIME). This systematic review aims to assess the correspondence of these non-invasive methods with the gold standard. Studies comparing non-invasive pharmacokinetic modelling methods with the current gold standard methods using an input function derived from arterial blood samples were retrieved from PubMed/MEDLINE (until December 2021). Correlation measurements were extracted from the studies. The search yielded 30 studies that correlated outcome parameters (VT, DVR, or BPND for reversible tracers; Ki or CMRglu for irreversible tracers) from a potentially non-invasive method with those obtained from modelling using an arterial input function. Some studies provided similar results for PBIF, IDIF, and SIME-based methods as for modelling with an arterial input function (R2 = 0.59-1.00, R2 = 0.71-1.00, R2 = 0.56-0.96, respectively), if the non-invasive input curve was calibrated with arterial blood samples. Even when the non-invasive input curve was calibrated with venous blood samples or when no calibration was applied, moderate to good correlations were reported, especially for the IDIF and SIME (R2 = 0.71-1.00 and R2 = 0.36-0.96, respectively). Overall, this systematic review illustrates that non-invasive methods to generate an input function are still in their infancy. Yet, IDIF and SIME performed well, not only with arterial blood calibration, but also with venous or no blood calibration, especially for some tracers without plasma metabolites, which would potentially make these methods better suited for clinical application. However, these methods should still be properly validated for each individual tracer and application before implementation.
Assuntos
Artérias , Encéfalo , Humanos , Artérias/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Cinética , Tomografia por Emissão de Pósitrons/métodos , VeiasRESUMO
The Blood-Brain Barrier P-glycoprotein (P-gp) function can be altered in several neurodegenerative diseases and due to the administration of different drugs which may cause alterations in drug concentrations and consequently lead to a reduced effectiveness or increased side-effects. The novel PET radiotracer [18F]MC225 is a weak P-gp substrate that may show higher sensitivity to detect small changes in P-gp function than previously developed radiotracers. This study explores the sensitivity of [18F]MC225 to measure the dose-dependent effect of P-gp inhibitor tariquidar. Twenty-three rats were intravenously injected with different doses of tariquidar ranging from 0.75 to 12 mg/kg, 30-min before the dynamic [18F]MC225-PET acquisition with arterial sampling. Tissue and blood data were fitted to a 1-Tissue-Compartment-Model to obtain influx constant K1 and distribution volume VT, which allow the estimation of P-gp function. ANOVA and post-hoc analyses of K1 values showed significant differences between controls and groups with tariquidar doses >3 mg/kg; while applying VT the analyses showed significant differences between controls and groups with tariquidar doses >6 mg/kg. Dose-response curves were fitted using different models. The four-parameter logistic sigmoidal curve provided the best fit for K1 and VT data. Half-maximal inhibitory doses (ID50) were 2.23 mg/kg (95%CI: 1.669-2.783) and 2.93 mg/kg (95%CI: 1.135-3.651), calculated with K1 or VT values respectively. According to the dose-response fit, differences in [18F]MC225-K1 values could be detected at tariquidar doses ranging from 1.37 to 3.25 mg/kg. Our findings showed that small changes in the P-gp function, caused by low doses of tariquidar, could be detected by [18F]MC225-K1 values, which confirms the high sensitivity of the radiotracer. The results suggest that [18F]MC225 may allow the quantification of moderate P-gp impairments, which may allow the detection of P-gp dysfunctions at the early stages of a disease and potential transporter-mediated drug-drug interactions.
Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Barreira Hematoencefálica , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Animais , Transporte Biológico , Barreira Hematoencefálica/metabolismo , Tomografia por Emissão de Pósitrons/métodos , RatosRESUMO
BACKGROUND: Pretargeted immuno-PET tumor imaging has emerged as a valuable diagnostic strategy that combines the high specificity of antibody-antigen interaction with the high signal and image resolution offered by short-lived PET isotopes, while reducing the irradiation dose caused by traditional 89Zr-labelled antibodies. In this work, we demonstrate proof of concept of a novel 'two-step' immuno-PET pretargeting approach, based on bispecific antibodies (bsAbs) engineered to feature dual high-affinity binding activity for a fluorescein-based 18F-PET tracer and tumor markers. RESULTS: A copper(I)-catalysed click reaction-based radiolabeling protocol was developed for the synthesis of fluorescein-derived molecule [18F]TPF. Binding of [18F]TPF on FITC-bearing bsAbs was confirmed. An in vitro autoradiography assay demonstrated that [18F]TPF could be used for selective imaging of EpCAM-expressing OVCAR3 cells, when pretargeted with EpCAMxFITC bsAb. The versatility of the pretargeting approach was showcased in vitro using a series of fluorescein-binding bsAbs directed at various established cancer-associated targets, including the pan-carcinoma cell surface marker EpCAM, EGFR, melanoma marker MCSP (aka CSPG4), and immune checkpoint PD-L1, offering a range of potential future applications for this pretargeting platform. CONCLUSION: A versatile pretargeting platform for PET imaging, which combines bispecific antibodies and a fluorescein-based 18F-tracer, is presented. It is shown to selectively target EpCAM-expressing cells in vitro and its further evaluation with different bispecific antibodies demonstrates the versatility of the approach.
RESUMO
This guideline on molar activity (Am) and specific activity (As) focusses on small molecules, peptides and macromolecules radiolabelled for diagnostic and therapeutic applications. In this guideline we describe the definition of Am and As, and how these measurements must be standardised and harmonised. Selected examples highlighting the importance of Am and As in imaging studies of saturable binding sites will be given, and the necessity of using appropriate materials and equipment will be discussed. Furthermore, common Am pitfalls and remedies are described. Finally, some aspects of Am in relation the emergence of a new generation of highly sensitive PET scanners will be discussed.
RESUMO
BACKGROUND: 6-[18F]fluoro-L-3,4-dihydroxyphenyl alanine ([18F]FDOPA) is a commonly used PET tracer for the detection and staging of neuroendocrine tumors. In neuroendocrine tumors, [18F]FDOPA is decarboxylated to [18F]dopamine via the enzyme amino acid decarboxylase (AADC), leading to increased uptake when there is increased AADC activity. Recently, in our hospital, a new GMP compliant multi-dose production of [18F]FDOPA has been developed, [18F]FDOPA-H, resulting in a higher activity yield, improved molar activity and a lower administered mass than the conventional method ([18F]FDOPA-L). AIMS: This study aimed to investigate whether the difference in molar activity affects the [18F]FDOPA uptake at physiological sites and in tumor lesions, in patients with NET. It was anticipated that the specific uptake of [18F]FDOPA-H would be equal to or higher than [18F]FDOPA-L. METHODS: We retrospectively analyzed 49 patients with pathologically confirmed NETs and stable disease who underwent PET scanning using both [18F]FDOPA-H and [18F]FDOPA-L within a time span of 5 years. A total of 98 [18F]FDOPA scans (49 [18F]FDOPA-L and 49 [18F]FDOPA-H with average molar activities of 8 and 107 GBq/mmol) were analyzed. The SUVmean was calculated for physiological organ uptake and SUVmax for tumor lesions in both groups for comparison, and separately in subjects with low tumor load (1-2 lesions) and higher tumor load (3-10 lesions). RESULTS: Comparable or slightly higher uptake was demonstrated in various physiological uptake sites in subjects scanned with [18F]FDOPA-H compared to [18F]FDOPA-L, with large overlap being present in the interquartile ranges. Tumor uptake was slightly higher in the [18F]FDOPA-H group with 3-10 lesion (SUVmax 6.83 vs. 5.19, p < 0.001). In the other groups, no significant differences were seen between H and L. CONCLUSION: [18F]FDOPA-H provides a higher activity yield, offering the possibility to scan more patients with one single production. Minor differences were observed in SUV's, with slight increases in uptake of [18F]FDOPA-H in comparison to [18F]FDOPA-L. This finding is not a concern for clinical practice, but could be of importance when quantifying follow-up scans while introducing new production methods with a higher molar activity of [18F]FDOPA.
RESUMO
OBJECTIVE: 5-(1-(2-[18F]fluoroethoxy))-[3-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-propyl]-5,6,7,8-tetrahydronaphthalen ([18F]MC225) is a selective substrate for P-glycoprotein (P-gp), possessing suitable properties for measuring overexpression of P-gp in the brain. This is the first-in-human study to examine safety, radiation dosimetry and P-gp function at the blood-brain barrier (BBB) of [18F]MC225 in healthy subjects. METHODS: [18F]MC225 biodistribution and dosimetry were determined in 3 healthy male subjects, using serial 2 h and intermittent 4 and 6 h whole-body PET scans acquired after [18F]MC225 injection. Dynamic [18F]MC225 brain PET (90 min) was obtained in 5 healthy male subjects. Arterial blood was sampled at various time intervals during scanning and the fraction of unchanged [18F]MC225 in plasma was determined. T1-weighted MRI was performed for anatomical coregistration. Total distribution volume (VT) was estimated using 1- and 2-tissue-compartment models (1-TCM and 2-TCM, respectively). VT was also estimated using the Logan graphical method (Logan plot) (t* = 20 min). Surrogate parameters without blood sampling (area-under the curve [AUC] of regional time-activity curves [TACs] and negative slope of calculated TACs) were compared with the VT values. RESULTS: No serious adverse events occurred throughout the study period. Although biodistribution implied hepatobiliary excretion, secretion of radioactivity from liver to small intestine through the gallbladder was very slow. Total renal excreted radioactivity recovered during 6 h after injection was < 2%ID. Absorbed dose was the highest in the pancreas (mean ± SD, 203 ± 45 µGy/MBq) followed by the liver (83 ± 11 µGy/MBq). Mean effective dose with and without urination was 17 ± 1 µSv/MBq. [18F]MC225 readily entered the brain, distributing homogeneously in grey matter regions. 2-TCM provided lower Akaike information criterion scores than did 1-TCM. VT estimated by Logan plot was well correlated with that of 2-TCM (r2 > 0.9). AUCs of TACs were positively correlated with VT (2-TCM) values (r2: AUC0-60 min = 0.61, AUC0-30 min = 0.62, AUC30-60 min = 0.59, p < 0.0001). Negative slope of SUV TACs was negatively correlated with VT (2-TCM) values (r2 = 0.53, p < 0.0001). CONCLUSIONS: This initial evaluation indicated that [18F]MC225 is a suitable and safe PET tracer for measuring P-gp function at the BBB.
Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATPRESUMO
BACKGROUND: [18F]MC225 is a radiotracer for imaging P-glycoprotein (P-gp) function at the blood-brain barrier. The P-gp function can be altered due to different factors, for instance, decreased P-gp function has been described in patients with Alzheimer's or Parkinson's Disease. The current applied radiosynthesis of [18F]MC225 involves 2 steps, including the distillation of the [18F] fluoroethylbromide intermediate. To develop a more robust synthetic procedure, it is of interest to produce the radiotracer via a 1-step synthesis. The present study describes a new synthetic approach to produce [18F]MC225 via direct 18F-fluorination. Moreover, we also provide the appropriate conditions for the automation of the synthesis. A mesylate precursor was synthesized via a multi-step synthetic route and used for the radiolabeling. The nucleophilic substitution of the mesylate group by [18F] Fluoride was automated in two different synthesis modules: IBA Synthera and Eckert and Ziegler PharmTracer (E&Z). RESULTS: The mesylate precursor was synthesized in 7 steps starting with 5-hydroxy-1-tetralone (commercially available) in practical yields. The stability of the precursor was improved via mesylate salt formation method. The radiolabeling was done by adding the mesylate precursor dissolved in DMF to the dried [18F]KF/K2.2.2 complex and heating at 140 °C for 30 min. Quality control by UPLC confirmed the production of [18F]MC225 with a molar activity (Am) higher than 100 GBq/micromole. The synthesis time in Synthera was 106 min and the product was obtained with a radiochemical purity higher than 95% and RCY of 6.5%, while the production in E&Z lasted 120 min and the product had a lower radiochemical purity (91%) and RCY (3.8%). CONCLUSIONS: [18F]MC225 was successfully produced via a 1-step reaction. The procedure is suitable for automation using commercially available synthesis modules. The automation of the radiosynthesis in the Synthera module allows the production of the [18F]MC225 by a reliable and simple method.
RESUMO
P-Glycoprotein (P-gp) is an efflux pump located at the blood-brain barrier (BBB) that contributes to the protection of the central nervous system by transporting neurotoxic compounds out of the brain. A decline in P-gp function has been related to the pathogenesis of neurodegenerative diseases. P-gp inducers can increase the P-gp function and are considered as potential candidates for the treatment of such disorders. The P-gp inducer MC111 increased P-gp expression and function in SW480 human colon adenocarcinoma and colo-320 cells, respectively. Our study aims to evaluate the P-gp inducing effect of MC111 in the whole brain in vivo, using the P-gp tracer [18F]MC225 and positron emission tomography (PET). Eighteen Wistar rats were treated with either vehicle solution, 4.5 mg/kg of MC111 (low-dose group), or 6 mg/kg of MC111 (high-dose group). Animals underwent a 60 min dynamic PET scan with arterial-blood sampling, 24 h after treatment with the inducer. Data were analyzed using the 1-tissue-compartment model and metabolite-corrected plasma as the input function. Model parameters such as the influx constant (K1) and volume of distribution (VT) were calculated, which reflect the in vivo P-gp function. P-gp and pregnane xenobiotic receptor (PXR) expression levels of the whole brain were assessed using western blot. The administration of MC111 decreased K1 and VT of [18F]MC225 in the whole brain and all of the selected brain regions. In the high-dose group, whole-brain K1 was decreased by 34% (K1-high-dose = 0.20 ± 0.02 vs K1-control = 0.30 ± 0.02; p < 0.001) and in the low-dose group by 7% (K1-low-dose = 0.28 ± 0.02 vs K1-control = 0.30 ± 0.02; p = 0.42) compared to controls. Whole-brain VT was decreased by 25% in the high-dose group (VT-high-dose = 5.92 ± 0.41 vs VT-control = 7.82 ± 0.38; p < 0.001) and by 6% in the low-dose group (VT-low-dose = 7.35 ± 0.38 vs VT-control = 7.82 ± 0.37; p = 0.38) compared to controls. k2 values did not vary after treatment. The treatment did not affect the metabolism of [18F]MC225. Western blot studies using the whole-brain tissue did not detect changes in the P-gp expression, however, preliminary results using isolated brain capillaries found an increasing trend up to 37% in treated rats. The decrease in K1 and VT values after treatment with the inducer indicates an increase in the P-gp functionality at the BBB of treated rats. Moreover, preliminary results using brain endothelial cells also sustained the increase in the P-gp expression. In conclusion, the results verify that MC111 induces P-gp expression and function at the BBB in rats. An increasing trend regarding the P-gp expression levels is found using western blot and an increased P-gp function is confirmed with [18F]MC225 and PET.
Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Barreira Hematoencefálica/metabolismo , Isoquinolinas/administração & dosagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Tetra-Hidronaftalenos/administração & dosagem , Animais , Transporte Biológico , Barreira Hematoencefálica/citologia , Células Endoteliais/metabolismo , Isoquinolinas/sangue , Isoquinolinas/síntese química , Cinética , Masculino , Compostos Radiofarmacêuticos/sangue , Compostos Radiofarmacêuticos/síntese química , Ratos , Ratos Wistar , Tetra-Hidronaftalenos/sangue , Tetra-Hidronaftalenos/síntese químicaRESUMO
The development of very fast, clean, and selective methods for indirect labeling in PET tracer synthesis is an ongoing challenge. Here we present the development of an ultrafast photoclick method for the synthesis of short-lived 18F-PET tracers based on the photocycloaddition reaction of 9,10-phenanthrenequinones with electron-rich alkenes. The respective precursors are synthetically easily accessible and can be functionalized with various target groups. Using a flow photo-microreactor, the photoclick reaction can be performed in 60 s, and clinically relevant tracers for prostate cancer and bacterial infection imaging were prepared to demonstrate practicality of the method.
RESUMO
PURPOSE: P-glycoprotein (P-gp) function is altered in several brain disorders; thus, it is of interest to monitor the P-gp function in vivo using PET. (R)-[11C]verapamil is considered the gold standard tracer to measure the P-gp function; however, it presents some drawbacks that limit its use. New P-gp tracers have been developed with improved properties, such as [18F]MC225. This study compares the characteristics of (R)-[11C]verapamil and [18F]MC225 in the same subjects. METHODS: Three non-human primates underwent 4 PET scans: 2 with (R)-[11C]verapamil and 2 with [18F]MC225, at baseline and after P-gp inhibition. The 30-min PET data were analyzed using 1-Tissue Compartment Model (1-TCM) and metabolite-corrected plasma as input function. Tracer kinetic parameters at baseline and after inhibition were compared. Regional differences and simplified methods to quantify the P-gp function were also assessed. RESULTS: At baseline, [18F]MC225 VT values were higher, and k2 values were lower than those of (R)-[11C]verapamil, whereas K1 values were not significantly different. After inhibition, VT values of the 2 tracers were similar; however, (R)-[11C]verapamil K1 and k2 values were higher than those of [18F]MC225. Significant regional differences between tracers were found at baseline, which disappeared after inhibition. The positive slope of the SUV-TAC was positively correlated to the K1 and VT of both tracers. CONCLUSION: [18F]MC225 and (R)-[11C]verapamil show comparable sensitivity to measure the P-gp function in non-human primates. Moreover, this study highlights the 30-min VT as the best parameter to measure decreases in the P-gp function with both tracers. [18F]MC225 may become the first radiofluorinated tracer able to measure decreases and increases in the P-gp function due to its higher baseline VT.
Assuntos
Barreira Hematoencefálica , Verapamil , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Animais , Barreira Hematoencefálica/metabolismo , Encéfalo/metabolismo , Radioisótopos de Carbono , Tomografia por Emissão de Pósitrons , Primatas/metabolismoAssuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP , Barreira Hematoencefálica , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Barreira Hematoencefálica/diagnóstico por imagem , Barreira Hematoencefálica/metabolismo , Encéfalo/metabolismo , Humanos , Tomografia por Emissão de PósitronsRESUMO
BACKGROUND: Microcalcifications cannot be identified with the present resolution of CT; however, 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) imaging has been proposed for non-invasive identification of microcalcification. The primary objective of this study was to assess whether 18F-NaF activity can assess the presence and predict the progression of CT detectable vascular calcification. METHODS AND RESULTS: The data of two longitudinal studies in which patients received a 18F-NaF PET-CT at baseline and after 6 months or 1-year follow-up were used. The target to background ratio (TBR) was measured on PET at baseline and CT calcification was quantified in the femoral arteries at baseline and follow-up. 128 patients were included. A higher TBR at baseline was associated with higher calcification mass at baseline and calcification progression (ß = 1.006 [1.005-1.007] and ß = 1.002 [1.002-1.003] in the studies with 6 months and 1-year follow-up, respectively). In areas without calcification at baseline and where calcification developed at follow-up, the TBR was .11-.13 (P < .001) higher compared to areas where no calcification developed. CONCLUSION: The activity of 18F-NaF is related to the amount of calcification and calcification progression. In areas where calcification formation occurred, the TBR was slightly but significantly higher.