Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 18(3): 239-247, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30111913

RESUMO

BACKGROUND: Prosthesis misfit plays an important role in complications such as occlusal and abutment screw loosening and fracture in implant restorations. Reproducing the intraoral relationship of implants through impression procedures is the first step in achieving an accurate, passively fitting prosthesis to ensure maximum accuracy. Hence, splinting of multiple implants with most accurate material may be a valid option. CONTEXT: The results of splinting multiple implants are always inconsistent, and there is limited literature available to compare the accuracy of impression techniques as well as materials. In such situation, more and more studies have to be done to prove the efficacy and accuracy of each splinting materials. AIM: The aim of the study was to evaluate the positional accuracy in multiple implants using acrylic resin, pattern resin, flowable composite, and bite registration paste. SUBJECTS AND METHODS: An acrylic resin model was fabricated into which four implant analogs placed. The copings attached were splinted with dental floss onto which acrylic resin was added, which was sectioned and rewelded (Group A). Similarly, pattern resin, flowable composite, and bite registration material were added which were considered as Group B, C, and D, respectively. Impressions were made in vinyl polysiloxane and analogs were attached. The casts retrieved from each group were analysed for the positional accuracy of implants. STATISTICAL ANALYSIS: One-way ANOVA was done to analyze the significant difference between the four implant analogs of each group with the master model. The confidence interval was also calculated to assess the accuracy. RESULTS: It was observed that all materials are equally effective for the accurate reproduction of implant positions. There was no significant difference between the centroids of implant analogues of master model and the mean of interimplant distance 1 and 2, 1 and 4, 3 and 4 and 2 and 4 in each group. The P-values were >0.05. The accuracy of splinting materials were analysed and it showed that splinting with flowable composite (Group C) as well as bite registration paste were in par with the conventionally used materials like pattern resin and acrylic resin. CONCLUSIONS: Results showed that flowable composite as well as bite registration material can be recommended as splinting material of choice for multiple implant cases, as these exhibited similar results like other groups (pattern resin and acrylic resin) which are conventionally used.

2.
J Indian Prosthodont Soc ; 18(1): 3-9, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29430135

RESUMO

BACKGROUND: Different pattern materials do not produce copings with satisfactory, marginal accuracy when used on stone dies at varying time intervals. PURPOSE: The purpose of this study was to evaluate and compare the vertical marginal accuracy of patterns formed from three materials, namely, thermoplastic resin, light cured wax and inlay casting wax at three-time intervals of 1, 12, and 24 h. METHODOLOGY: A master die (zirconia abutment mimicking a prepared permanent maxillary central incisor) and metal sleeve (direct metal laser sintering crown #11) were fabricated. A total of 30 stone dies were obtained from the master die. Ten patterns were made each from the three materials and stored off the die at room temperature. The vertical marginal gaps were measured using digital microscope at 1, 12, and 24 h after reseating with gentle finger pressure. RESULTS: The results revealed a significant statistical difference in the marginal adaptation of three materials at all the three-time intervals. Light cured wax was found to be most accurate at all time intervals, followed by thermoplastic resin and inlay casting wax. Furthermore, there was a significant difference between all pairs of materials. The change in vertical marginal gap from 1 to 24 h between thermoplastic resin and light cured wax was not statistically significant. CONCLUSION: The marginal adaptation of all the three materials used, was well within the acceptable range of 25-70 µm. The resin pattern materials studied revealed significantly less dimensional change than inlay casting wax on storage at 1, 12, and 24 h time intervals. They may be employed in situations where high precision and delayed investing is expected.

3.
J Indian Prosthodont Soc ; 18(1): 76-81, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29430147

RESUMO

The defects of the skull cause mechanical vulnerability of the brain, esthetic disfigurement, and transmission of vibrations and pulsation of the brain. Subsequent cranioplasty may be required to compensate for the defect and to alleviate various signs and symptoms. When long-term outcome of biomaterial use in pediatric cases is limited, alloplastic cranioplasty in adults are supported by several large case series. This case report narrates cranioplasty using titanium alloplastic implant material.

4.
J Indian Prosthodont Soc ; 16(4): 352-358, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27746599

RESUMO

BACKGROUND AND OBJECTIVES: This in vitro study compared the shade matching abilities of an intraoral spectrophotometer and the conventional visual method using two shade guides. The results of previous investigations between color perceived by human observers and color assessed by instruments have been inconclusive. The objectives were to determine accuracies and interrater agreement of both methods and effectiveness of two shade guides with either method. METHODS: In the visual method, 10 examiners with normal color vision matched target control shade tabs taken from the two shade guides (VITAPAN Classical™ and VITAPAN 3D Master™) with other full sets of the respective shade guides. Each tab was matched 3 times to determine repeatability of visual examiners. The spectrophotometric shade matching was performed by two independent examiners using an intraoral spectrophotometer (VITA Easyshade™) with five repetitions for each tab. RESULTS: Results revealed that visual method had greater accuracy than the spectrophotometer. The spectrophotometer; however, exhibited significantly better interrater agreement as compared to the visual method. While VITAPAN Classical shade guide was more accurate with the spectrophotometer, VITAPAN 3D Master shade guide proved better with visual method. CONCLUSION: This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA