Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Animals (Basel) ; 13(5)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36899731

RESUMO

Premature regression of corpora lutea (PRCL) may adversely affect the outcome of hormonal ovarian superstimulation in small ruminants, and the total dose of exogenous gonadotropins used may be one of the causes of this condition. There were two major objectives of the present study: (1) to evaluate the effects of different superovulatory doses of porcine follicle-stimulating hormone (pFSH) on the biometry, blood perfusion (Doppler), and echotextural characteristics of luteal structures; and, (2) to determine the usefulness of biometric, vascular, and echotextural luteal variables, as well as measurements of circulating progesterone (P4) concentrations for early detection of PRCL in superovulated Santa Inês ewes. Twenty-seven Santa Inês ewes received an intravaginal P4-releasing device (CIDR) from Days 0 to 8 (Day 0 = random day of the anovulatory period). An IM injection of d-cloprostenol (37.5 µg) was given at the time of the CIDR insertion and withdrawal. On Day 6, all the ewes received 300 IU of eCG IM and were divided into three treatment groups (each n = 9): G100 (100 mg); G133 (133 mg); and G200 (200 mg of pFSH) administered IM every 12 h in eight injections. Transrectal ovarian ultrasonography and jugular blood sampling for serum P4 measurements were performed on Days 11 to 15. On the day of embryo recovery (Day 15), all the ewes underwent diagnostic videolaparoscopy and were classified, based on their luteal characteristics, into three response groups: nCL (ewes with normal CL only); rCL (ewes with regressing CL only); and ewes with both nCL and rCL following the superovulatory regimen. Our present results indicate that the total pFSH doses of 100 mg and 200 mg result in similar ovulatory responses and luteal function/biometrics, although the percentage of donor ewes with nCL was greater (p < 0.05) for G100 compared with the G200 animals. An application of 133 mg of pFSH was associated with diminished luteogenesis. Lastly, circulating P4 concentrations, ultrasonographic estimates of total luteal area, and CL pixel heterogeneity (standard deviation of numerical pixel values) are promising markers of luteal inadequacy in superovulated ewes.

2.
Reprod Domest Anim ; 55(3): 364-373, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31945229

RESUMO

Elastography is an actual imaging method used to qualitatively and quantitatively evaluate the elastic properties of tissues. The aim of this study was to evaluate and compare uterine tissue biometry and stiffness during post-partum period in brachycephalic bitches (n = 12) after c-section (GCS; n = 8) or normal delivery (GNB; n = 4). These animals were evaluated daily by abdominal ultrasound from the day of delivery until the 10th day post-partum; measuring uterine diameter, myometrial and endometrial thickness (mm) and shear wave velocity (SWV; m/s), by B-mode and ARFI (acoustic radiation force impulse) elastography, respectively. Uterine diameter was higher (p = .012) in animals submitted to c-section (15.26 ± 4.73 mm) than in normal birth (12.53 ± 2.64 mm) during the first 7 days post-partum. Uterine thickness gradually involuted in both groups (p < .0001), the myometrium during the first 9 days (p = .005) and the endometrium during the first 6 days (p = .003). The myometrial and endometrial SWVs were similar between types of delivery (p = .7846 and .8273) and presented a gradual increase (p = .411; .0043, respectively), during the first 10 days post-partum. It was concluded that bitches with normal delivery had smaller uterine thickness and faster puerperal involution than submitted to c-section, while uterine tissue stiffness was similar between delivery types and increased gradually during post-partum.


Assuntos
Cesárea/veterinária , Parto Obstétrico/veterinária , Cães/fisiologia , Técnicas de Imagem por Elasticidade/veterinária , Útero/diagnóstico por imagem , Animais , Cesárea/efeitos adversos , Craniossinostoses/veterinária , Parto Obstétrico/efeitos adversos , Cães/cirurgia , Feminino , Período Pós-Parto , Gravidez
3.
Anim Reprod Sci ; 209: 106137, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31514927

RESUMO

To evaluate follicular dynamics, there was assessment of superovulatory response and in vivo embryo production in ewes treated with relatively smaller doses of exogenous pFSH than typically used in combination with a dose of eCG at the beginning of the gonadotropin treatment period. Santa Inês ewes (n = 24) were randomly divided into three groups, based on mg dose of pFSH administered: G200 (n = 8), G133 (n = 8) and G100 (n = 8) in eight decreasing doses at 12 -h intervals. All ewes were treated with 300 IU of eCG concomitantly starting with first pFSH administration. Ovulatory follicular dynamics and follicular wall vascularization (FWV) were evaluated using a B-mode and color Doppler ultrasonic machine, respectively. Superovulatory response and embryo production were evaluated 6 days after estrous detection. In the G200 group, the preovulatory follicle size (PFS) were less (P <  0.05), ovulation time later (P <  0.05), and PFS rate greater (P <  0.05); while in the G100 group ovulation rate, and number and percentage of unfertilized eggs were greater (P <  0.05) than in the G133 group (P <  0.05). Number and percentage of viable embryos were greater in the G200 and G100 compared to G133 group (P <  0.05). The dose of 100 mg of FSH was as efficacious as the traditional dose of 200 mg, in combination with a dose of eCG, for superovulatory response and viable embryo production but there was a greater percentage of unfertilized eggs with this treatment.


Assuntos
Hormônio Foliculoestimulante/administração & dosagem , Inseminação Artificial , Folículo Ovariano/efeitos dos fármacos , Folículo Ovariano/fisiologia , Indução da Ovulação , Ovinos , Animais , Brasil , Tamanho Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Embrião de Mamíferos , Feminino , Inseminação Artificial/métodos , Inseminação Artificial/veterinária , Oogênese/efeitos dos fármacos , Oogênese/fisiologia , Folículo Ovariano/irrigação sanguínea , Ovulação/efeitos dos fármacos , Indução da Ovulação/métodos , Indução da Ovulação/veterinária , Gravidez , Ovinos/embriologia , Superovulação/fisiologia , Clima Tropical
4.
Vet Radiol Ultrasound ; 59(4): 444-452, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29430763

RESUMO

Due to the importance of presurgical, noninvasive, and accurate diagnostic tools in mammary carcinoma characterization, this prospective secondary observational cohort study was designed to evaluate and compare the diagnostic accuracy of B-mode, Doppler, contrast enhancement ultrasonography, or acoustic radiation force impulse-elastography in identifying mammary carcinomas types with high degree of malignancy. A total of 246 mammary carcinomas from 141 female dogs were analyzed using B-mode, Doppler, contrast enhancement ultrasonography, and acoustic radiation force impulse ultrasonography prior to their histopathological classification according to types (simple, complex, or special) and grade (I, II, or III). Qualitative and quantitative variables were compared between carcinoma types and grades by Fisher's or analysis of variance. Diagnostic performance was estimated by receiver-operating characteristic analysis, using histopathological classification as a reference. Deformability (acoustic radiation force impulse) had a diagnostic specificity of 100% and sensitivity of 12% in identifying special carcinomas. A width:length ratio greater than 0.53 can be suggestive of special carcinoma, with 80% sensitivity and 76% specificity. Contrast wash-in and peak enhancement times lower than 7.5 and 13.5 s, respectively, were indicative of complex carcinoma at 62% sensitivity and 60% specificity. Contrast wash-in, peak enhancement, and wash-out times greater than 6.5, 12.5, and 64.5 s, respectively; were indicative of grade II and III carcinoma at 68% sensitivity and 62% specificity. In conclusion, B-mode ultrasonography, contrast enhancement ultrasonography, and acoustic radiation force impulse-elastography enabled the identification of some of the characteristics of high-grade mammary carcinoma types and grades in female dogs with limited accuracy. The findings from this study may contribute to oncology research and clinical management canine patients.


Assuntos
Neoplasias da Mama/veterinária , Doenças do Cão/diagnóstico por imagem , Neoplasias Mamárias Animais/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Neoplasias da Mama/classificação , Neoplasias da Mama/diagnóstico por imagem , Doenças do Cão/classificação , Cães , Feminino , Neoplasias Mamárias Animais/classificação , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA