Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Neurol ; 15(11): 1191-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18727674

RESUMO

BACKGROUND AND PURPOSE: To examine whether three-dimensional (3-D) kinematic analysis can detect changes in upper limb tasks (reach and hand-to-mouth) in children with hemiplegia, following upper limb botulinum toxin A injections. METHODS: Ten children with hemiplegic cerebral palsy (7 males, 3 females, aged 9-17 years). Subjects received botulinum toxin A (Botox) injections into elbow forearm muscles combined with 6 weeks of occupational therapy. Participants completed a 3-D kinematic analysis of two upper limb tasks, Melbourne Assessment of Unilateral Upper Limb Function and modified Ashworth scores measured at baseline, 2, 6 and 12 weeks post-injection. RESULTS: Post-injections, elbow flexor muscle tone was reduced for 12 weeks (p < 0.05). Group differences in active range of motion during 3-D analysis tasks could not be demonstrated at any time post-intervention. However, individual analyses found that at 2 weeks post-injection, three subjects had >15 degrees increases in active elbow extension and six subjects showed an increase of >25 degrees in forearm supination during performance of the reach and hand-to-mouth tasks, respectively. CONCLUSIONS: 3-D kinematics can detect changes in active movements during functional tasks following botulinum toxin A injections, suggesting this could be a potential objective outcome measure in a clinical trial.


Assuntos
Toxinas Botulínicas Tipo A/uso terapêutico , Paralisia Cerebral/complicações , Avaliação da Deficiência , Hemiplegia/diagnóstico , Avaliação de Resultados em Cuidados de Saúde/métodos , Adolescente , Fenômenos Biomecânicos , Criança , Cotovelo/fisiopatologia , Feminino , Hemiplegia/tratamento farmacológico , Hemiplegia/etiologia , Humanos , Masculino , Espasticidade Muscular/diagnóstico , Espasticidade Muscular/tratamento farmacológico , Espasticidade Muscular/etiologia , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia , Exame Neurológico/métodos , Fármacos Neuromusculares/uso terapêutico , Valor Preditivo dos Testes , Amplitude de Movimento Articular/efeitos dos fármacos , Amplitude de Movimento Articular/fisiologia , Resultado do Tratamento
2.
Gait Posture ; 28(4): 634-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18534854

RESUMO

This study evaluated within- and between-session reliability and validity of temporal-spatial gait parameters derived from the intelligent device for energy expenditure and activity (IDEEA) activity monitor (Minisun, Fresno, CA) in subjects with cerebral palsy, using three-dimensional gait analysis (3-DGA) as the criterion standard. Twenty-five subjects with cerebral palsy (mean age 14.1 years, range 8-23) and 30 control subjects (mean age 14.2 years, range 7-24) completed two 3-DGA, 1 week apart with simultaneous IDEEA data collection. The IDEEA had lower within-session reliability than the 3-DGA for both groups, indicated by greater measurement errors and wider repeatability values for all temporal-spatial parameters. Between-session reliability of 3-DGA was high for both groups with intra-class correlation coefficients (ICC) >0.80. The IDEEA monitor showed high between-session reliability for control subjects (ICC 0.71-0.89), but lower reliability in subjects with cerebral palsy, particularly for walking velocity and stride length (ICC 0.53 and 0.62, respectively). Validity comparison between IDEEA and 3-DGA measures using Bland Altman 95% limits of agreement showed a measurement bias, with the IDEEA over-estimating step and stride length and underestimating cadence in both subject groups compared to 3-DGA. The 95% limits of agreement were smaller in controls (step +/-0.20 m; stride +/-0.27 m; walking velocity +/-0.28 m/s) than in subjects with cerebral palsy (step +/-0.36 m; stride +/-0.37 m; velocity +/-0.58 m/s). Modifications may be necessary to improve the reliability and validity of the IDEEA in children, particularly for use in neurological conditions.


Assuntos
Fenômenos Biomecânicos , Paralisia Cerebral/fisiopatologia , Marcha/fisiologia , Aceleração , Adolescente , Adulto , Calibragem , Criança , Metabolismo Energético , Desenho de Equipamento , Feminino , Humanos , Masculino , Software , Transdutores de Pressão , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA