Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Hybrid Imaging ; 4(1): 6, 2020 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-34191149

RESUMO

BACKGROUND: PET/MRI has a high potential in oncology imaging, especially for tumor indications where high soft tissue contrast is crucial such as genitourinary tumors. One of the challenges for PET/MRI acquisition is handling of metal implants. In addition to conventional methods, more innovative techniques have been developed to reduce artifacts caused by those implants such as the selective multiacquisition variable-image combination (MAVRIC-SL). The aim of this study is to perform a quantitative and qualitative assessment of metal artifact reduction in 68Ga-PSMA-11 PET/MRI for prostate cancer patients with hip joint replacement using a selective MAVRIC-SL sequence for the whole pelvis. METHODS: We retrospectively analyzed data of 20 men with 37 metal hip implants diagnosed with PCA, staged or restaged by 68Ga-PSMA-11 PET/MRI from June 2016 to December 2017. Each signal cancellation per side or metal implant was analyzed on the reference sequence LAVA-FLEX, as well as T1-weighted fast spin echo (T1w-FSE) sequence and MAVRIC-SL. Two independent reviewers reported on a four-point scale whether abnormal pelvic 68Ga-PSMA-11 uptake could be assigned to an anatomical structure in the tested sequences. RESULTS: The smallest averaged signal void was observed on MAVRIC-SL sequences with a mean artifact size of 26.17 cm2 (range 12.63 to 42.93 cm2, p < 0.001). The best image quality regarding anatomical assignment of pathological PSMA uptakes in the pelvis by two independent readers was noted for MAVRIC-SL sequences, followed by T1w-FSE with excellent interreader agreement. CONCLUSIONS: MAVRIC-SL sequence allows better image quality in the surrounding of hip implants by reducing MR signal voids and increasing so the accuracy of anatomical assignment of pathological 68Ga-PSMA-11 uptake in the pelvis over LAVA-FLEX and T1w-FSE sequences.

2.
Updates Surg ; 70(1): 129-136, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28913787

RESUMO

The background of this paper is to report the mortality at 30 and 90 days and at mean follow-up after open abdominal aortic aneurysms (AAA) emergent repair and to identify predictive risk factors for 30- and 90-day mortality. Between 1997 and 2002, 104 patients underwent emergent AAA open surgery. Symptomatic and ruptured AAAs were observed, respectively, in 21 and 79% of cases. Mean patient age was 70 (SD 9.2) years. Mean aneurysm maximal diameter was 7.4 (SD 1.6) cm. Primary endpoints were 30- and 90-day mortality. Significant mortality-related risk factor identification was the secondary endpoint. Open repair trend and its related perioperative mortality with a per-year analysis and a correlation subanalysis to identify predictive mortality factor were performed. Mean follow-up time was 23 (SD 23) months. Overall, 30-day mortality was 30%. Significant mortality-related risk factors were the use of computed tomography (CT) as a preoperative diagnostic tool, AAA rupture, preoperative shock, intraoperative cardiopulmonary resuscitation (CPR), use of aortic balloon occlusion, intraoperative massive blood transfusion (MBT), and development of abdominal compartment syndrome (ACS). Previous abdominal surgery was identified as a protective risk factor. The mortality rate at 90 days was 44%. Significant mortality-related risk factors were AAA rupture, aortocaval fistula, peripheral artery disease (PAD), preoperative shock, CPR, MBT, and ACS. The mortality rate at follow-up was 45%. Correlation analysis showed that MBT, shock, and ACS are the most relevant predictive mortality factor at 30 and 90 days. During the transition period from open to endovascular repair, open repair mortality outcomes remained comparable with other contemporary data despite a selection bias for higher risk patients. MBT, shock, and ACS are the most pronounced predictive mortality risk factors.


Assuntos
Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Enxerto Vascular/métodos , Idoso , Emergências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
3.
J Nucl Med ; 55(4): 551-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24491410

RESUMO

UNLABELLED: Considering PET/MR imaging as a whole-body staging tool, scan time restrictions in a single body area are mandatory for the cost-effective clinical operation of an integrated multimodality scanner setting. It has to be considered that (18)F-FDG already acts as a contrast agent and that under certain circumstances MR contrast may not yield additional clinically relevant information. The concept of the present study was to understand which portions of the imaging information enhance the sensitivity and specificity of the hybrid examination and which portions are redundant. METHODS: One hundred fifty consecutive patients referred for primary staging or restaging of head and neck cancer underwent sequential whole-body (18)F-FDG PET with CT-based attenuation correction, contrast-enhanced (ce) CT, and conventional diagnostic MR imaging of the head and neck in a trimodality PET/CT-MR system. Assessed were image quality, lesion conspicuity, diagnostic confidence, and the benefit of additional coronal and sagittal imaging planes in cePET/CT, PET/MR imaging with only T2-weighted fat-suppressed images (T2w PET/MR imaging), and cePET/MR imaging. RESULTS: In 85 patients with at least 1 PET-positive lesion, 162 lesions were evaluated. Similar robustness was found for CT and MR image quality. T2w PET/MR imaging performed similarly to (metastatic lymph nodes) or better than (primary tumors) cePET/CT in the morphologic characterization of PET-positive lesions and permitted the diagnosis of necrotic or cystic lymph node metastasis without application of intravenous contrast medium. CePET/MR imaging yielded a higher diagnostic confidence for accurate lesion conspicuity (especially in the nasopharynx and in the larynx), infiltration of adjacent structures, and perineural spread. CONCLUSION: The results of the present study provide evidence that PET/MR imaging can serve as a legitimate alternative to PET/CT in the clinical workup of patients with head and neck cancers. Intravenous MR contrast medium may be applied only if the exact tumor extent or infiltration of crucial structures is of concern (i.e., preoperatively) or if perineural spread is anticipated. In early assessment of the response to therapy, in follow-up examinations, or in a whole-body protocol for non-head and neck tumors, T2w PET/MR imaging may be sufficient for coverage of the head and neck. The additional MR scanning time may instead be used for advanced MR techniques to increase the specificity of the hybrid imaging examination.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estadiamento de Neoplasias , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
4.
Eur J Nucl Med Mol Imaging ; 40(1): 44-51, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22955547

RESUMO

PURPOSE: PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. METHODS: A total of 100 oncological patients underwent sequential whole-body (18)F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. RESULTS: From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. CONCLUSION: Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Compostos Radiofarmacêuticos , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA