RESUMO
Aim: Rapid detection is crucial in complementing vaccination to reduce transmission of SARS-CoV-2. Materials & methods: Nasopharyngeal swabs (n = 213) and oropharyngeal swabs (n = 98) were tested. with the antigen rapid test kit. Results: Overall sensitivity (97.96%), specificity (100.00%) and coincidence rate (98.71%) were high, which translated into a positive predictive value of 100.00% and a negative predictive value of 96.64%. Conclusion: Antigen rapid tests have a great potential for screening in different settings to deliver results with high sensitivity and specificity.
This study evaluated SG Diagnostics COVID-19 antigen rapid test kit. The overall sensitivity, specificity and coincidence rate were found very high with SG Diagnostics COVID-19 antigen rapid test kit performing better.
RESUMO
The biofilm-associated infections of bones are life-threatening diseases, requiring application of dedicated antibiotics in order to counteract the tissue damage and spread of microorganisms. The in vitro analyses on biofilm formation and susceptibility to antibiotics are frequently carried out using methods that do not reflect conditions at the site of infection. To evaluate the influence of nutrient accessibility on Staphylococcus aureus biofilm development in vitro, a cohesive set of analyses in three different compositional media was performed. Next, the efficacy of four antibiotics used in bone infection treatment, including gentamycin, ciprofloxacin, levofloxacin, and vancomycin, against staphylococcal biofilm, was also assessed. The results show a significant reduction in the ability of biofilm to grow in a medium containing elements occurring in the serum, which also translated into the diversified changes in the efficacy of used antibiotics, compared to the setting in which conventional media were applied. The differences indicate the need for implementation of adequate in vitro models that closely mimic the infection site. The results of the present research may be considered an essential step toward the development of in vitro analyses aiming to accurately indicate the most suitable antibiotic to be applied against biofilm-related infections of bones.
Assuntos
Osteomielite , Infecções Estafilocócicas , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Biofilmes , Ciprofloxacina , Gentamicinas , Humanos , Levofloxacino/farmacologia , Levofloxacino/uso terapêutico , Testes de Sensibilidade Microbiana , Osteomielite/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus , Vancomicina/farmacologia , Vancomicina/uso terapêuticoRESUMO
BACKGROUND: A 2017 update of the resuscitation guideline indicated the use of cardiopulmonary resuscitation (CPR) feedback devices as a resuscitation teaching method. The aim of the study was to compare the influence of two techniques of CPR teaching on the quality of resuscitation performed by medical students. METHODS: The study was designed as a prospective, randomized, simulation study and involved 115 first year students of medicine. The participants underwent a basic life support (BLS) course based on the American Heart Association guidelines, with the first group (experimental group) performing chest compressions to observe, in real-time, chest compression parameters indicated by software included in the simulator, and the second group (control group) performing compressions without this possibility. After a 10-minute resuscitation, the participants had a 30-minute break and then a 2-minute cycle of CPR. One month after the training, study participants performed CPR, without the possibility of observing real-time measurements regarding quality of chest compression. RESULTS: One month after the training, depth of chest compressions in the experimental and control group was 50 mm (IQR 46-54) vs. 39 mm (IQR 35-42; p = 0.001), compression rate 116 CPM (IQR 102-125) vs. 124 CPM (IQR 116-134; p = 0.034), chest relaxation 86% (IQR 68-89) vs. 74% (IQR 47-80; p = 0.031) respectively. CONCLUSIONS: Observing real-time chest compression quality parameters during BLS training may improve the quality of chest compression one month after the training including correct hand positioning, compressions depth and rate compliance.
Assuntos
Reanimação Cardiopulmonar , Manequins , Retroalimentação , Humanos , Estudos Prospectivos , SoftwareRESUMO
With different videolaryngoscopes for pediatric patients available, UEScope can be used in all age groups. The aim of this study was to compare the Miller laryngoscope and UEScope in pediatric intubation by paramedics in different scenarios. Overall, 93 paramedics with no experience in pediatric intubation or videolaryngoscopy performed endotracheal intubation in scenarios: (A) normal airway without chest compressions, (B) difficult airway without chest compressions, (C) normal airway with uninterrupted chest compressions, (D) difficult airway with uninterrupted chest compressions. Scenario A. Total intubation success with both laryngoscopes: 100%. First-attempt success: 100% for UEScope, 96.8% for Miller. Median intubation time for UEScope: 13 s [IQR, 12.5-17], statistically significantly lower than for Miller: 14 s [IQR, 12-19.5] (p = 0.044). Scenario B. Total efficacy: 81.7% for Miller, 100% for UEScope (p = 0.012). First-attempt success: 48.4% for Miller, 87.1% for UEScope (p = 0.001). Median intubation time: 27 s [IQR, 21-33] with Miller, 15 s [IQR, 14-21] with UEScope (p = 0.001). Scenario C. Total efficiency: 91.4% with Miller, 100% with UEScope (p = 0.018); first-attempt success: 67.7 vs. 90.3% (p = 0.003), respectively. Intubation time: 21 s [IQR, 18-28] for Miller, 15 s [IQR, 12-19.5] for UEScope. Scenario D. Total efficiency: 65.6% with Miller, 98.9% with UEScope (p < 0.001); first-attempt success: 29.1 vs. 72% (p = 0.001), respectively. Intubation time: 38 s [IQR, 23-46] for Miller, 21 s [IQR, 17-25.5] for UEScope.Conclusion: In pediatric normal airway without chest compressions, UEScope is comparable with Miller. In difficult pediatric airways without chest compressions, UEScope offers better first-attempt success, shorted median intubation time, and improved glottic visualization. With uninterrupted chest compressions in normal or difficult airway, UEScope provides a higher first-attempt success, a shorter median intubation time, and a better glottic visualization than Miller laryngoscope. What is Known: ⢠Endotracheal intubation is the gold standard for adult and children airway management. ⢠More than two direct laryngoscopy attempts in children with difficult airways are associated with a high failure rate and increased incidence of severe complications. What is New: ⢠In difficult pediatric airways with or without chest compressions, UEScope in inexperienced providers in simulated settings provides better first-attempt efficiency, median intubation time, and glottic visualization.
Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios/normas , Adulto , Pessoal Técnico de Saúde/educação , Reanimação Cardiopulmonar/métodos , Pré-Escolar , Estudos Cross-Over , Medicina de Emergência/educação , Feminino , Massagem Cardíaca/métodos , Humanos , Masculino , Manequins , Estudos Prospectivos , Treinamento por SimulaçãoRESUMO
Endotracheal intubation is the gold standard for airway management. Supraglottic airway devices (SADs) are useful in airway abnormalities. SAD blind intubation enables airway management with better ventilation and a reduced risk of gastric content aspiration. The aim was to compare various SADs in blind intubation performed by inexperienced physicians in several pediatric airway scenarios. One hundred sixteen physicians with no previous experience with SAD performed blind endotracheal intubations with (1) iGEL, (2) Air-Q intubating laryngeal airway, and (3) Ambu AuraGain disposable laryngeal mask in a pediatric manikin in three airway scenarios: (A) normal airway without chest compressions, (B) normal airway with continuous chest compressions with the CORPULS CPR system, and (C) difficult airway with continuous chest compressions with the CORPULS CPR system. Intubation tube with 5.0 internal diameter was used for all blind intubation attempts. First intubation success rate, median time to SAD placement, time to endotracheal intubation with SAD, and ease to perform the intubation were investigated in this study. All these parameters were better or non-inferior for iGEL in all investigated scenarios.Conclusion: Our manikin study demonstrated that iGEL was the most effective device for blind intubation by inexperienced physicians in different pediatric airway scenarios. What is Known: ⢠For pediatric resuscitation, bag-mask ventilation is the first-line method for airway control and ventilation. ⢠Endotracheal intubation is considered by many scientific societies the gold standard for airway management. ⢠Supraglottic airway devices are particularly useful when bag-mask ventilation is difficult or impossible but can be also used for blind intubation. What is New: ⢠The iGEL laryngeal mask turns out the most effective device for blind intubation by inexperienced physicians in different pediatric airway scenarios. ⢠It may be a reasonable first emergency blind intubation technique for inexperienced physicians in pediatric patients in normal airway with and without continuous chest compressions, as well as in difficult airway with continuous chest compressions.
Assuntos
Competência Clínica , Medicina de Emergência/educação , Intubação Intratraqueal/instrumentação , Reanimação Cardiopulmonar/métodos , Pré-Escolar , Estudos Cross-Over , Humanos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Laringoscopia/métodos , Manequins , Treinamento por SimulaçãoRESUMO
BACKGROUND: In newborns, ventilation is a key resuscitation element but optimal chest compression (CC) improves resuscitation quality. The study compared two infant CC techniques during simulated newborn resuscitation performed by nurses. METHODS: The randomized crossover manikin, multicenter trial involved 52 nurses. They underwent training with two CC techniques: standard two-finger technique (TFT) and novel two-thumb technique (NTTT; two thumbs at 90° to the chest, fingers in a fist). One week later, the participants performed resuscitation with the two techniques. A Tory® S2210 Tetherless and Wireless Full-term Neonatal Simulator was applied, with a 3:1 compression to ventilation ratio. CC quality in accordance with the 2015 American Heart Association guidelines was assessed during the 2-min resuscitation. RESULTS: Median CC depth was 30 mm for TFT and 37 mm for NTTT (p = 0.002). Correct hand placement reached 98% in both techniques; full chest relaxation was obtained in 97% vs. 94% for TFT and NTTT, respectively. CC fraction was slightly better for NTTT (74% vs. 70% for TFT; p = 0.044), the ventilation volume was comparable for both techniques. On a 100-degree scale (1 - no fatigue; 100 - extreme fatigue), the participant tiredness achieved 72 points (IQR 61-77) for TFT vs. 47 points (IQR 40-63) for NTTT (p = 0.034). For real resuscitation, 86.5% would choose NTTT and 13.5% TFT. CONCLUSIONS: The NTTT technique proved superior to TFT. Evidence suggests that NTTT offers better CC depth in various medical personnel groups. One-rescuer TFT quality is not consistent with resuscitation guidelines.
Assuntos
Reanimação Cardiopulmonar/enfermagem , Competência Clínica , Morte Súbita Cardíaca/prevenção & controle , Massagem Cardíaca/enfermagem , Manequins , Treinamento por Simulação , Adulto , Estudos Cross-Over , Feminino , Humanos , Recém-Nascido , Masculino , Polônia , Pressão , Estudos Prospectivos , Fatores de Tempo , Adulto JovemRESUMO
BACKGROUND: Endotracheal intubation (ETI) can be challenging, especially in life-threatening situations such as cardiopulmonary resuscitation (CPR). Videolaryngoscopes aim to ease ETI, but effort is still widely discussed. This study intended to investigate 2 different airway devices regarding the success rate of ETI during ongoing chest compressions. METHODS: This randomized, cross-over, multi-center manikin trial included 85 experienced paramedics actively working in the emergency medicine service. After a standardized training session, all paramedics underwent 3 airway scenarios using both, direct laryngoscopy using a Macintosh blade and videolaryngoscope (the UEScope): normal airway without chest compressions, normal airway with uninterrupted chest compressions, and difficult airway with uninterrupted chest compressions. The primary outcome was successful ETI, defined as successful placement of the endotracheal tube within the manikin's trachea. Secondary outcomes were number of intubation attempts, time to successful ETI, time to best glottis view, best percent of glottic opening, best glottic view score (Cormack and Lehane), occurrence of dental trauma, ease of use, and willing to reuse in real-life situations. RESULTS: The UEScope provided a better glottis visualization, and higher first pass intubation success rate compared to direct laryngoscopy in all 3 scenarios. The overall intubation success was higher, and the intubation time was shorter with the UEScope in scenario B and scenario C, but was comparable in scenario A. Dental compression occurred less often using the UEScope and paramedics rated intubation using the UEScope easier compared to direct laryngoscopy in all 3 airway scenarios. CONCLUSION: In simulated CPR scenarios, intubation with the UEScope resulted in a better glottis visualization, a higher intubation success, and a shorter intubation time compared to Macintosh laryngoscope (MAC). Moreover, in situations where the airway is difficult for ETI especially by the paramedic, the UEScope would be a better choice than the MAC. Further studies are needed to confirm these results in real-life patients.
Assuntos
Reanimação Cardiopulmonar/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Adulto , Pessoal Técnico de Saúde , Reanimação Cardiopulmonar/métodos , Estudos Cross-Over , Feminino , Glote/diagnóstico por imagem , Humanos , Laringoscopia/métodos , Masculino , Manequins , Fatores de Tempo , Gravação em VídeoAssuntos
Reanimação Cardiopulmonar , Laringoscópios , Criança , Humanos , Intubação Intratraqueal , LaringoscopiaAssuntos
Laringoscópios , Manuseio das Vias Aéreas , Pessoal Técnico de Saúde , Criança , Humanos , Intubação Intratraqueal , ManequinsRESUMO
Emergency airway management in children is generally considered to be challenging, and endotracheal intubation requires a high level of personal skills and experience. Immobilization of the cervical spine is indicated in all patients with the risk of any cervical spine injury but significantly aggravates endotracheal intubation. The best airway device in this setting has not been established yet, although the use of videolaryngoscopes is generally promising. Seventy-five moderately experienced paramedics of the Emergency Medical Service of Poland performed endotracheal intubations in a pediatric manikin in three airway scenarios: (A) normal airway, (B) manual in-line cervical immobilization, and (C) cervical immobilization using a Patriot cervical extrication collar and using two airway techniques: (1) McGrath videolaryngoscope and (2) Macintosh blade in a randomized sequence. First-attempt intubation success rate, time to intubation, glottis visualization, and subjective ease of intubation were investigated in this study. Intubation of difficult airways, including manual in-line and cervical collar immobilization, using the McGrath was significantly faster, with a higher first-attempt intubation success rate, better glottic visualization, and ease of intubation, compared to Macintosh-guided intubation. In the normal airway, both airway techniques performed equal. CONCLUSION: Our manikin study indicates that the McGrath may be a reasonable first intubation technique option for endotracheal intubation in difficult pediatric emergencies. Further clinical studies are therefore indicated. What is known : ⢠Airway management in pediatrics is challenging and requires a high level of skills and experience. Cervical immobilization is indicated in all patients with any risk of cervical spine injury, but it significantly aggravates endotracheal intubation in these patients. Videolaryngoscopes have been reported to ease intubation and provide better airway visualization in the regular clinical setting. What is new: ⢠The McGrath is an easy-to-use and clinically often used videolaryngoscope, but it has never been investigated in pediatrics with an immobilized cervical spine. In the normal airway, the McGrath provided better airway visualization compared to Macintosh laryngoscopy. However, better visualization did not lead to decreased time to intubation and a higher success rate of the first intubation attempt. In difficult airways, the McGrath provided better airway visualization and this led to faster intubation, a higher first-attempt intubation success rate, and better ease of intubation compared to Macintosh-guided intubation.
Assuntos
Tratamento de Emergência/instrumentação , Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Restrição Física , Vértebras Cervicais , Criança , Competência Clínica , Estudos Cross-Over , Auxiliares de Emergência , Tratamento de Emergência/métodos , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Manequins , Fatores de Tempo , Gravação em VídeoRESUMO
CONTEXT: Management of the airway of a trauma victim is considered challenging. Various approaches have been described to achieve airway control in this setup; many of them include video-assited viewing of the larynx during intubation. ETView Single Lumen (SL) is a novice single-use endotracheal tube equiped with a video camera and a light source at its distal tip. Its use was previously described in seeral clinical and training setups. OBJECTIVE: The aim was to evaluate the efficacy of the VivaSight SL compared with classic direct laryngoscopy performed with a Macintosh blade in a manikin-simulated trauma setup presenting various degrees of airway challenge when performed by inexperienced physicians. DESIGN, SETTING, PARTICIPANTS: This was prospective, randomized, crossover, manikin trial. After short training on the ETView system, 67 novice paramedics attempted to perform oral intubation using both standard direct laryngoscopy (MAC group) and the VivaSight SL endotracheal tube (ETView group) in a randomized order on manikins in 3 increasingly more difficult scenarios (simple intubation, cervical spine manual stabilization, and with cervical collar in place). OUTCOME MEASURE: Overall success rate, time to intubation, number of intubation attempts, laryngeal view grade, dental compression, and overall participant satisfaction were monitored. RESULTS: Duration of intubation and number of attempts were significantly superior in the ETView group in the latter 2 more challenging scenarios. All other parameters showed superiority to the ETView group in all 3 scenarios. CONCLUSION: The VivaSight SL system performed better in a complex scenario of airway management of a trauma victim in need for cervical spine stabilization performed by novice caregivers compared to standard direct laryngoscopy and should be considered in this clinical setup.
Assuntos
Pessoal Técnico de Saúde , Braquetes , Intubação Intratraqueal/instrumentação , Laringoscópios , Adulto , Vértebras Cervicais , Competência Clínica , Estudos Cross-Over , Serviços Médicos de Emergência , Humanos , Imobilização , Laringoscopia/instrumentação , Manequins , Fatores de Tempo , Resultado do Tratamento , Gravação em VídeoAssuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Projetos Piloto , TóraxRESUMO
INTRODUCTION: Endotracheal intubation (ETI) using a Macintosh laryngoscope (MAC) requires the head to be positioned in a modified Jackson position, slightly reclined and elevated. Intubation of trauma patients with an injured neck or spine is therefore difficult, since the neck usually cannot be turned or is already immobilized in order to prevent further injury. The iGEL supraglottic airway seems optimal for such conditions due to its blind insertion without the need of a modified Jackson position. METHODS: Prospective, randomized, crossover study in 46 paramedics. Participants performing standard intubation and blind intubation via iGEL supraglottic airway device in three airway scenarios: Scenario A - normal airway; Scenario B - manual inline cervical immobilization, performed by an independent instructor; scenario C: cervical immobilization using a standard Patriot cervical extraction collar. RESULTS: In Scenario A, nearly all participants performed ETI successfully both with MAC and iGEL (100% vs. 95.7%). The time to intubation (TTI) using the MAC and iGEL amounted to 19 [IQR, 18-21]s vs. 12 [IQR, 11-13]s (P<0.001). Head extension angle as well as tooth compression were significantly better with the iGEL compared to the MAC (P<0.001). In scenario B and C, the results with the iGEL were significantly better than with MAC for all analyzed variables (TTI, success of first intubation attempt, head extension angle, tooth compression and VAS scores). CONCLUSION: We showed that blind intubation with the iGEL supraglottic airway was superior to ETI performed by paramedics in a simulated cervical immobilization scenario in a manikin in terms of success rate, time to definite tube placement, head extension angle, tooth compression, and rating.