Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Front Bioeng Biotechnol ; 11: 1153969, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324440

RESUMO

Introduction: The metal-organic frameworks (MOF) have shown fascinating possibilities in biomedical applications, and designing a drug delivery system (DDS) based on the MOF is important. This work aimed at developing a suitable DDS based on Denosumab-loaded Metal Organic Framework/Magnesium (DSB@MOF (Mg)) for attenuating osteoarthritis. Materials and Methods: The MOF (Mg) (Mg3(BPT)2(H2O)4) was synthesized using a sonochemical protocol. The efficiency of MOF (Mg) as a DDS was evaluated by loading and releasing DSB as a drug. In addition, the performance of MOF (Mg) was evaluated by releasing Mg ions for bone formation. The MOF (Mg) and DSB@MOF (Mg) cytotoxicity towards the MG63 cells were explored by MTT assay. Results: MOF (Mg) characterized by using XRD, SEM, EDX, TGA, and BET. Drug loading, and releasing experiments proved that DSB was loaded on the MOF (Mg) and approximately 72% DSB was released from it after 8 h. The characterization techniques showed that MOF (Mg) was successfully synthesized with good crystal structure and thermal stability. The result of BET showed that MOF (Mg) had high surface areas and pore volume. This is the reason why its 25.73% DSB was loaded in the subsequent drug-loading experiment. Drug release and ion release experiments indicated DSB@MOF (Mg) had a good controlled release of DSB and Mg ions in solution. Cytotoxicity assay confirmed that the optimum dose of it had excellent biocompatibility and could stimulate the proliferation of MG63 cells as time went on. Conclusion: Due to the high loading amount of DSB and releasing time, DSB@MOF (Mg) can be promising as a suitable candidate for relieving bone pain caused by osteoporosis, with ossification-reinforcing functions.

2.
Children (Basel) ; 9(11)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36360332

RESUMO

To investigate how plyometric exercise (PLYO-Ex) affects mechanics and morphometrics of the plantar flexor musculotendinous unit in children with unilateral cerebral palsy, 38 participants (aged 10-16 years) were allocated at random to either the PLYO-Ex group (n = 19; received 24 sessions of plyometric muscle loading, conducted 2 times a week for 3 months in succession) or the control group (n = 19; underwent traditional physical therapy for the same frequency and duration). Measurements were taken pre- and post-intervention. Standard ultrasound imaging was applied to evaluate morphometrics of the gastrocnemius muscle and Achilles tendon unit and an isokinetic dynamometer was used to evaluate maximum voluntary isometric plantar flexors contraction (IVCmax). With controlling for pre-treatment values, significant post-treatment changes favoring the PLYO-Ex group were observed for morphological (tendon (p = 0.003, η2p = 0.23) length; belly length (p = 0.001, η2p = 0.27); tendon thickness (p = 0.035, η2p = 0.35); muscle thickness (p = 0.013, η2p = 0.17); fascicle length (p = 0.009, η2p = 0.18); pennation angle (p = 0.015, η2p = 0.16)) and mechanical and material properties (IVCmax (p = 0.009, η2p = 0.18); tendon's elongation (p = 0.012, η2p = 0.17), stiffness (p = 0.027, η2p = 0.13); stress (p = 0.006, η2p = 0.20); strain (p = 0.004, η2p = 0.21)). In conclusion, plyometric exercise induces significant adaptations within the musculotendinous unit of the plantar flexors in children with unilateral cerebral palsy. These adaptations could improve muscular efficiency and consequently optimize physical/functional performance.

3.
RSC Adv ; 12(31): 20156-20173, 2022 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-35919614

RESUMO

A new approach has been developed for environmentally friendly C-C cross-coupling reactions using bi-functional Pd(ii)-salen complex-embedded cellulose filter paper (FP@Si-PdII-Salen-[IM]OH). A Pd(ii)-salen complex bearing imidazolium [OH]-moieties was covalently embedded into a plain filter paper, then used as an efficient portable catalyst for the Heck, Suzuki, and Sonogashira cross-coupling reactions under environmentally friendly conditions via the filtration method. The catalytic filter paper properties were studied by EDX, XPS, TGA, ATR, XRD, and FESEM analyses. The reactions were catalyzed during reactants' filtration over the catalytic filter paper. The modified filter paper was set up over a funnel and the reactants were passed through the catalytic filter paper several times. The effect of reaction parameters including loading of Pd(ii)-salen complex, temperature, solvent, and contact time were carefully studied and also the optimal model of conditions was presented by the design expert software. High to excellent yields were obtained for all C-C coupling types with 5 to 8 filtration times. Under optimal conditions, all coupling reactions showed high selectivity and efficiency. Another advantage of the modified filter paper was its stability and reusability for several times with preservation of catalytic activity and swellability.

4.
Curr Med Imaging ; 19(5): 486-493, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35927895

RESUMO

BACKGROUND: Chest High-Resolution Computed Tomography (HRCT) is mandatory for patients with confirmed Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection and a high Respiratory Rate (RR) because sublobar consolidation is the likely pathological pattern in addition to Ground Glass Opacities (GGOs). OBJECTIVE: The present study determined the correlation between the percentage extent of typical pulmonary lesions on HRCT, as a representation of severity, and the RR and peripheral oxygen saturation level (SpO2), as measured through pulse oximetry, in patients with Reverse Transcriptase Polymerase Chain Reaction (RT-PCR)-confirmed primary (noncomplicated) SARS-CoV-2 pneumonia. METHODS: The present retrospective study was conducted in 332 adult patients who presented with dyspnea and hypoxemia and were admitted to Prince Mohammed bin Abdulaziz Hospital, Riyadh, Saudi Arabia between May 15, 2020 and December 15, 2020. All the patients underwent chest HRCT. Of the total, 198 patients with primary noncomplicated SARS-CoV-2 pneumonia were finally selected based on the typical chest HRCT patterns. The main CT patterns, GGO and sublobar consolidation, were individually quantified as a percentage of the total pulmonary involvement through algebraic summation of the percentage of the 19 pulmonary segments affected. Additionally, the statistical correlation strength between the total percentage pulmonary involvement and the age, initial RR, and percentage SpO2 of the patients was determined. RESULTS: The mean ± Standard Deviation (SD) age of the 198 patients was 48.9 ± 11.4 years. GGO magnitude alone exhibited a significant weak positive correlation with patients' age (r = 0.2; p = 0.04). Sublobar consolidation extent exhibited a relatively stronger positive correlation with RR than GGO magnitude (r = 0.23; p = 0.002). A relatively stronger negative correlation was observed between the GGO extent and SpO2 (r = - 0.38; p = 0.002) than that between sublobar consolidation and SpO2 (r = - 0.2; p = 0.04). An increase in the correlation strength was demonstrated with increased case segregation with GGO extent (r = - 0.34; p = 0.01). CONCLUSION: The correlation between the magnitudes of typical pulmonary lesion patterns, particularly GGO, which exhibited an incremental correlation pattern on chest HRCT, and the SpO2 percentage, may allow the establishment of an artificial intelligence program to differentiate primary SARS-CoV-2 pneumonia from other complications and associated pathology influencing SpO2.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Adulto , Pessoa de Meia-Idade , COVID-19/diagnóstico por imagem , Estudos Retrospectivos , Inteligência Artificial , Saturação de Oxigênio , Tomografia Computadorizada por Raios X/métodos
5.
Appl Radiat Isot ; 187: 110348, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35779304

RESUMO

PURPOSE: This study aimed to determine the radioprotective effect of N-acetylcysteine (NAC) on the radiation-induced oxidative stress (OS) in the rats' brainstem. MATERIALS AND METHODS: Eighty rats in four identical groups, including vehicle control (VC), irradiation alone (RAD), irradiation with 1 g/kg of NAC treatment (RAN), and NAC treatment without radiation (NAC) were used. Whole-brain irradiation was performed with a single dose of 25 Gy. The rats received the treatments via intraperitoneal (IP) injection 1 h before the irradiation process. Nitric oxide (NO), malondialdehyde (MDA), superoxide dismutase (SOD), catalase (CAT), total antioxidant capacity (TAC), and glutathione peroxidase (GPx) were measured in the rats' brainstem and compared between the groups. Furthermore, the pathological study was performed to assess tissue damage after 24 h, 72 h, and 5 days of irradiation. RESULTS: The levels of NO and MDA in the brainstem tissue for the RAD group were 60.37 ± 3.35 µmol/L and 45.10 ± 2.48 µM, respectively, which were higher than those of VC group (NO: 30.41 ± 1.83 µmol/L; MDA: 31.02 ± 1.71 µM). The level of SOD, CAT, TAC, and GPx declined in the RAD compared to the VC group. Pre-treatment with NAC decreased the level of NO and MDA and also enhanced the antioxidant activities. The greatest pathological changes in the rats' brainstems were seen in RAD animals compared to the VC group at 24 h, 72 h, and 5 days. Furthermore, the pathological changes were not observed in the NAC group in all the assessed times. CONCLUSION: Based on the results, NAC can decrease the irradiation-induced oxidative stress and pathology damages in the rats' brainstem. It can be concluded that NAC can be an appropriate radioprotection candidate for the human brainstem.


Assuntos
Acetilcisteína , Antioxidantes , Tronco Encefálico , Protetores contra Radiação , Acetilcisteína/farmacologia , Animais , Antioxidantes/metabolismo , Tronco Encefálico/metabolismo , Tronco Encefálico/efeitos da radiação , Glutationa Peroxidase/metabolismo , Malondialdeído/metabolismo , Protetores contra Radiação/farmacologia , Ratos , Superóxido Dismutase/metabolismo , Raios X/efeitos adversos
6.
Nanomaterials (Basel) ; 12(9)2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-35564313

RESUMO

This study aims to study the discharging process to verify the influence of geometry modifications and heat transfer flow (HTF) patterns on the performance of a vertical triplex-tube latent heat container. The phase change material (PCM) is included in the middle tube, where the geometry is modified using single or multi-internal frustum tubes instead of straight tubes to enhance the discharging rate. The effects of the HTF flow direction, which is considered by the gravity and opposite-gravity directions, are also examined in four different cases. For the optimal geometry, three scenarios are proposed, i.e., employing a frustum tube for the middle tube, for the inner tube, and at last for both the inner and middle tubes. The effects of various gap widths in the modified geometries are investigated. The results show the advantages of using frustum tubes in increasing the discharging rate and reducing the solidification time compared with that of the straight tube unit due to the higher natural convection effect by proper utilization of frustum tubes. The study of the HTF pattern shows that where the HTF direction in both the inner and outer tubes are in the gravity direction, the maximum discharging rate can be achieved. For the best configuration, the discharge time is reduced negligibly compared with that for the system with straight tubes which depends on the dimensions of the PCM domain.

7.
RSC Adv ; 12(18): 10933-10949, 2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35425081

RESUMO

A reductive filter paper for selective nitro reduction has been prepared by modification of a pristine cellulose filter paper by Pd/C nanoparticles, as a portable catalyst. The reaction was performed in two different set-ups including (i) filtration and (ii) sealed systems, in the presence of ammonium formate and ex situ generated hydrogen gas reducing agents, respectively. In the sealed system in the presence of H2 gas, the halogenated nitroarenes were completely reduced, while in the filtration system, different derivatives of the nitroarenes were selectively reduced to aryl amines. In both systems, the reduction of nitroarenes to aryl amines was performed with high efficiency and selectivity, comparable to a heterogeneous system. Reaction parameters were comprehensively designed using Design Expert software and then studied. The properties of the catalytic filter paper were studied in detail from the points of view of swellability, shrinkage, reusability, and stability against acidic, alkaline, and oxidative reagents.

8.
Anal Methods ; 14(13): 1301-1310, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-35318477

RESUMO

The human epidermal growth factor receptor 2 (HER-2) protein is a member of the epidermal growth factor receptor (EGFR or ErbB) family and is a transmembrane tyrosine kinase receptor. HER-2 is highly regulated in ovarian, lung, gastric, oral, and breast cancers. The low specificity, complexity, expensiveness and the lack of sensitivity are essential restrictions in traditional diagnosis methods such as FISH, immunohistochemistry and PCR and these disadvantages led to the need for more studies on alternative methods. Biosensor technology has greatly affected the quality of human life owing to its features including, sensitivity, specificity, and rapid diagnosis and monitoring of different patient diseases. In this review article, we examine various biosensors, considering that they have been categorized based on the transducers used including piezoelectric biosensors, optical sensors such as fluorescence and surface plasmon resonance, and electrochemical types for the diagnosis of HER-2 and the effectiveness of some drugs against that. Attention to developing some types of biosensor devices such as colorimetric biosensors for HER-2 detection can be an important point in future studies.


Assuntos
Técnicas Biossensoriais , Neoplasias , Biomarcadores Tumorais , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Humanos , Neoplasias/diagnóstico , Receptor ErbB-2/genética
9.
Nanomaterials (Basel) ; 12(3)2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35159751

RESUMO

Employing phase-change materials (PCM) is considered a very efficient and cost-effective option for addressing the mismatch between the energy supply and the demand. The high storage density, little temperature degradation, and ease of material processing register the PCM as a key candidate for the thermal energy storage system. However, the sluggish response rates during their melting and solidification processes limit their applications and consequently require the inclusion of heat transfer enhancers. This research aims to investigate the potential enhancement of circular fins on intensifying the PCM thermal response in a vertical triple-tube casing. Fin arrays of non-uniform dimensions and distinct distribution patterns were designed and investigated to determine the impact of modifying the fin geometric characteristics and distribution patterns in various spatial zones of the heat exchanger. Parametric analysis on the various fin structures under consideration was carried out to determine the most optimal fin structure from the perspective of the transient melting evolution and heat storage rates while maintaining the same design limitations of fin material and volume usage. The results revealed that changing the fin dimensions with the heat-flow direction results in a faster charging rate, a higher storage rate, and a more uniform temperature distribution when compared to a uniform fin size. The time required to fully charge the storage system (fully melting of the PCM) was found to be reduced by up to 10.4%, and the heat storage rate can be improved by up to 9.3% compared to the reference case of uniform fin sizes within the same fin volume limitations.

10.
J Colloid Interface Sci ; 610: 879-892, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34865739

RESUMO

Herein, two distinct nanocomposites of CaTiO3 micro-cubes and polygonal SrFe12O19, both decorated with NiO nanoparticles, were successfully synthesized using hydrothermal method. The physico-chemical features of as-prepared samples were evaluated via XRD, FTIR, UV-vis, BET, XPS, FESEM and EDS analysis. Microwave attenuation features of as-prepared single layer absorbers were determined by VNA analysis in 2-18 GHz. Simulation confirmation was checked by preparing a bi-layer samples and evaluating it using VNA analysis after finding the appropriate thickness of each layer. The reflection loss from each single layer samples containing 20 wt% of each CaTiO3/NiO and SrFe12O19/NiO nanocomposites were -16 dB and -35 dB at 6.3 GHz with 2.5 mm matching thickness respectively. However, the RL was -34 dB at 10 GHz frequency with 2 mm thickness in a bilayer absorber with SrFe12O19/NiO nanocomposite layer put as absorbing layer with 1 mm thickness and CaTiO3/NiO positioned as matching layer with 1 mm thickness. Furthermore, at the X-band frequency, approximately entire band absorption is obtained. The findings demonstrate that adjusting the order and thickness of the layers in a bilayer absorber may readily improve microwave absorption performance. By comparing the results of simulation with real prepared bilayer absorbers, we found that with a 2 mm overall thickness, the bi-layer absorbers display accurate RL values, but not the matching frequency monitored in the simulation process. In reality, this discrepancy was unavoidable.


Assuntos
Nanocompostos , Micro-Ondas
11.
Nanomaterials (Basel) ; 11(12)2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34947559

RESUMO

Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that moving the HTF tubes to medium positions along the vertical direction is relatively better for enhancing the solidification of PCM with multiple HTF tubes. Repositioning of the HTF tubes on the left side of the unit can slightly improve the heat removal rate by about 0.2 in the case of p5-u-1 and decreases by 1.6% in the case of p5-u-2. It was found also that increasing the distance between the tubes in the vertical direction has a detrimental effect on the PCM solidification mode. Replacing the HTF tubes on the left side of the unit negatively reduces the heat removal rate by about 1.2 and 4.4%, respectively. Further, decreasing the HTF temperature from 15 °C to 10 and 5 °C can increase the heat removal rate by around 7 and 16%, respectively. This paper indicates that the specific concern to the HTF tube arrangement should be made to improve the discharging process attending free convection impact in phase change heat storage.

12.
Nanomaterials (Basel) ; 11(11)2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34835917

RESUMO

Due to the potential cost saving and minimal temperature stratification, the energy storage based on phase-change materials (PCMs) can be a reliable approach for decoupling energy demand from immediate supply availability. However, due to their high heat resistance, these materials necessitate the introduction of enhancing additives, such as expanded surfaces and fins, to enable their deployment in more widespread thermal and energy storage applications. This study reports on how circular fins with staggered distribution and variable orientations can be employed for addressing the low thermal response rates in a PCM (Paraffin RT-35) triple-tube heat exchanger consisting of two heat-transfer fluids flow in opposites directions through the inner and the outer tubes. Various configurations, dimensions, and orientations of the circular fins at different flow conditions of the heat-transfer fluid were numerically examined and optimized using an experimentally validated computational fluid-dynamic model. The results show that the melting rate, compared with the base case of finless, can be improved by 88% and the heat charging rate by 34%, when the fin orientation is downward-upward along the left side and the right side of the PCM shell. The results also show that there is a benefit if longer fins with smaller thicknesses are adopted in the vertical direction of the storage unit. This benefit helps natural convection to play a greater role, resulting in higher melting rates. Changing the fins' dimensions from (thickness × length) 2 × 7.071 mm2 to 0.55 × 25.76 mm2 decreases the melting time by 22% and increases the heat charging rate by 9.6%. This study has also confirmed the importance of selecting the suitable values of Reynolds numbers and the inlet temperatures of the heat-transfer fluid for optimizing the melting enhancement potential of circular fins with downward-upward fin orientations.

13.
Sci Rep ; 11(1): 20476, 2021 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-34650073

RESUMO

The increased frequency of neurological manifestations, including central nervous system (CNS) manifestations, in patients with coronavirus disease 2019 (COVID-19) pandemic is consistent with the virus's neurotropic nature. In most patients, brain magnetic resonance imaging (MRI) is a sensitive imaging modality in the diagnosis of viral encephalitides in the brain. The purpose of this study was to determine the frequency of brain lesion patterns on brain MRI in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pneumonia patients who developed focal and non-focal neurological manifestations. In addition, it will compare the impact of the Glasgow Coma Scale (GCS) as an index of deteriorating cerebral function on positive brain MRIs in both neurological manifestations. This retrospective study included an examination of SARS-CoV-2 pneumonia patients with real-time reverse transcription polymerase chain reaction (RT-PCR) confirmation, admitted with clinicoradiologic evidence of COVID-19 pneumonia, and who were candidates for brain MRI due to neurological manifestations suggesting brain involvement. Brain imaging acquired on a 3.0 T MRI system (Skyra; Siemens, Erlangen, Germany) with a 20-channel receive head coil. Brain MRI revealed lesions in 38 (82.6%) of the total 46 patients for analysis and was negative in the remaining eight (17.4%) of all finally enclosed patients with RT-PCR confirmed SARS-CoV-2 pneumonia. Twenty-nine (63%) patients had focal neurological manifestations, while the remaining 17 (37%) patients had non-focal neurological manifestations. The patients had a highly significant difference (p = 0.0006) in GCS, but no significant difference (p = 0.4) in the number of comorbidities they had. Brain MRI is a feasible and important imaging modality in patients with SARS-CoV-2 pneumonia who develop neurological manifestations suggestive of brain involvement, particularly in patients with non-focal manifestations and a decline in GCS.


Assuntos
Encefalopatias/etiologia , Encéfalo/diagnóstico por imagem , COVID-19/complicações , Adulto , Idoso , Encéfalo/patologia , Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , COVID-19/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação
14.
Sci Rep ; 11(1): 14958, 2021 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294777

RESUMO

Ischemic heart disease (IHD), also known as coronary artery disease (CAD), is a leading cause of morbidity and mortality in adults. The aims of this research were to study the recent advances on the prognostic and diagnostic value, drawbacks, and the future directions of cardiac magnetic resonance imaging (CMRI) in the diagnosis of IHD. One hundred patients with IHD who had been clinically diagnosed were enrolled in this study prospectively. CMRI; Siemens Magnetom Sola 1.5 T MRI scanner was used to examine the patients. To confirm the diagnosis, conventional coronary angiography was used. CMRI revealed that the left ventricular (LV) volumes and systolic function of male and female patients differed by age decile were 28.9 ± 3.5%; 32 ± 1.7%, 53.3 ± 11.2; 58 ± 6.6 ml, 100.6 ± 7.1; 98.3 ± 14.7 bpm, 5.4 ± 1.4; 5.8 ± 1.5 L/min, 189 ± 14.3; 180 ± 10.9 ml, and 136 ± 3.1; 123 ± 4.4 ml for the left ventricle ejection fraction (LVEF), stroke volume (SV), heart rate, cardiac output, end diastolic volume (EDV), and end systolic volume (ESV), respectively. CMRI has sensitivity, specificity, and accuracy of 97%, 33.33%, and 95.15%, respectively. Finally, CMRI provides a comprehensive assessment of LV function, myocardial perfusion, and viability, as well as coronary anatomy.


Assuntos
Imagem Cinética por Ressonância Magnética/instrumentação , Isquemia Miocárdica/diagnóstico por imagem , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Volume Sistólico , Função Ventricular Esquerda , Adulto Jovem
15.
West Indian med. j ; 69(4): 201-206, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1515648

RESUMO

ABSTRACT Objective: To measure the Achilles tendon length, thickness and cross-sectional area in asymptomatic adult Saudi participants and to investigate the possible changes in these measurements based on their different ages and body height. Methods: The prospective cohort study was done between January 2014 and March 2015. A total of 200 asymptomatic participants with 175 males (87.5%) and 25 females (12.5%) between the ages of 14 and 65 years, with the mean age of 25 ± 1.5 years, were scanned at two radiology departments. Ultrasound (US) scans for the Achilles tendons were performed using a Hitachi (EZU-MT30-S1 HI Vision Avius, Hitachi, Japan) US machine. Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) was used to analyse the results. Results: There was no significant difference in the length, cross-sectional area and thickness of the Achilles tendons among the participants of different ages; however, the cross-sectional area of Achilles tendons of the older participants (≥ 47 years) was higher than that of the participants of the younger age groups. Moreover, there was no correlation between the length, cross-sectional area, and thickness of the Achilles tendons and their body heights; however, the participants of ≥ 153 cm in height showed an increase in their Achilles tendon cross-sectional areas. Conclusion: Ultrasound is a useful imaging tool in the assessment of the Achilles tendons. The normal variations of the tendon morphological characteristics should be considered in the clinical diagnosis. Additional studies on the correlations among the Achilles tendon length, thickness and cross-sectional areas of ethnicity of the participants in Saudi Arabia are suggested.

16.
J Manipulative Physiol Ther ; 43(2): 152-159, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32482435

RESUMO

OBJECTIVES: To evaluate the effect of 3 different time durations of sustained end-range cervical rotation during static stretching exercises on the hemodynamics of the vertebral artery. METHODS: This observational study used Doppler ultrasonography to measure the average vertebral artery hemodynamics at the sustained end-range cervical rotation after 3 time durations of static stretching exercise: 10 seconds, 30 seconds, and 60 seconds. The sustained end-range cervical rotation was applied to 30 asymptomatic male participants. RESULTS: The peak systolic velocity 35.2 ± 6.9 cm/s and the end systolic velocity 12.7 ± 1.6 cm/s reduced significantly, while resistive index 0.74 ± 0.03 increased after 60 seconds of sustained end-range contralateral cervical rotation by 39.1%, 32.4%, and 8.8%, respectively, compared with the neutral position. There were no significant differences found between peak systolic velocity and resistive index after a stretching duration of 60 and 30 seconds. Similarly, there were no notable changes in end systolic velocity when comparing 10 seconds with 30 seconds. CONCLUSION: The static stretching exercise using sustained end-range cervical rotation for 60 seconds induced marked changes in the hemodynamics of the vertebral artery.


Assuntos
Exercícios de Alongamento Muscular/fisiologia , Amplitude de Movimento Articular/fisiologia , Artéria Vertebral/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Vértebras Cervicais/fisiologia , Feminino , Cabeça/fisiologia , Hemodinâmica , Humanos , Masculino , Pescoço/fisiologia , Músculos Paraespinais/fisiologia , Estresse Mecânico , Ultrassonografia , Artéria Vertebral/diagnóstico por imagem
17.
J Clin Imaging Sci ; 9: 36, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31538034

RESUMO

OBJECTIVE: The aim of the study was to identify the pathological characteristics of benign and malignant breast lesions among Saudi females using brightness mode (B-mode) and color Doppler ultrasound (US). MATERIALS AND METHODS: This study was retrospectively carried out in a single center in the Radiology and Medical Imaging Department, King Fahad Medical City, Riyadh, Saudi Arabia. A convenient method of sampling was used to include all patients referred for different diagnosis during the period of January 2016 and December 2018. A sample size of 100 cases was selected with 50% of the cases being benign breast lesions, while the rest were malignant. The data collection instruments comprised data collection sheets, while a Philips US system with a 9 MHz linear probe was used to give the differential results. The results were considered significant when P < 0.05. The statistical diagnostic test was used to detect sensitivity, specificity, and accuracy of US in the differential diagnosis of breast lesions in Saudi females. RESULTS: B-mode and color Doppler US findings of breast mass measurements, shape, echotexture, and the presence and absence of vascularity present a sensitivity, specificity, and accuracy of 97.09%, 80.65%, and 93.28% in the diagnosis of benign and malignant breast masses. CONCLUSION: In Saudi females with dense breasts, the risk of breast cancer development is increased. Moreover, B-mode in combination with color Doppler US was highly determined the results of differential diagnosis for any breast lesions.

18.
J Clin Imaging Sci ; 9: 37, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31538035

RESUMO

OBJECTIVE: The purpose of this research was to determine the frequency of incidental extraspinal findings in the thoracic spine on magnetic resonance imaging (MRI). MATERIALS AND METHODS: A total of 120 thoracic spine MRI patients were prospectively examined in the period extending from August 2018 to April 2019. Both 1.5 and 0.35 Tesla MRI systems (Toshiba and Siemens Medical system) were applied to investigate patients with suspected intervertebral disc abnormalities at three MRI diagnostic centers in Khartoum, Sudan. RESULTS: Out of the 120 patients, incidental extraspinal findings were found in 16 patients (13.3%). Various incidental findings (IFs) were seen, including renal cysts, liver mass, thyroid goiter, and pleural effusion. Out of these IFs, 37.5% were considered clinically significant. CONCLUSIONS: Various IFs were identified during a routine thoracic spine MRI, and approximately one-third of them were clinically significant. Therefore, it is essential for the reporting radiologists to pay attention to extraspinal findings while reporting thoracic spine MRI to avoid missing clinically significant findings.

19.
Heliyon ; 4(9): e00803, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30246162

RESUMO

PURPOSE: To calculate the frequencies of incidental extraspinal findings and incidentally detected congenital anomalies or anatomical differences in the lumbar spine on magnetic resonance imaging (MRI) scans of intervertebral discs. MATERIALS AND METHODS: A total of 379 lumbar spine MRI cases were prospectively investigated in the period spanning from August 2016 to January 2018. Both 1.5 and 0.35 Tesla MRI units (Toshiba and Siemens Medical Systems) were used to examine patients with clinically suspected intervertebral disc abnormalities at three MRI diagnostic centers in Khartoum State, Sudan. RESULTS: Of the 379(100%) patients, 90(23.7%) patients were presented with incidental findings. Among the incidental findings, 39(10.3%) were renal cysts, 10(2.6%) were retroverted uteri, 5(1.3%) were Nabothian cysts, 4(1.1%) were ovarian cysts, 10(2.6%) were uterine fibroids, 3(0.8%) were endometrial thickening, 11(2.9%) were indicative of hydronephrosis, 4(1.1%) were uncovered prostatic enlargement, 2(0.5%) were atrophic kidney, and 1(0.3%) each was of an ectopic kidney and bladder wall thickening, respectively. CONCLUSIONS: A high percentage of extraspinal pathological findings were detected during MRI lumbar spine scans of intervertebral discs. Thus, it is important to be aware of the high percentage of patients who undergo further evaluation given the presence of unexpected findings, but for whom clinical confirmation of these abnormalities is not obtained.

20.
Eur J Radiol Open ; 5: 79-86, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30069496

RESUMO

PURPOSE: To determine the causes of low vision among Sudanese patients with diabetic retinopathy (DR) by using ophthalmic B-scan ultrasonography. MATERIALS AND METHODS: A total of 100 patients with DR at different grades, were recruited prospectively between September 2016 and January 2018. Nidek (Echoscan US-4000) ultrasound unit was used to determine the causes of low vision in diabetic patients according to their glycated haemoglobin (HbA1c) and early treatment of diabetic retinopathy scale (ETDRS) severity levels. RESULTS: Vitreous hemorrhage (VH) 42(66.6%), asteroid hyalosis (AH) 12(14.3%), and partial retinal detachment (PRD) 9(19%) were the main cause of low vision in patients presenting with moderately regulated HbA1c and graded with either minimal or mild nonproliferative retinopathy (NPDR). While VH 15(40.5%), total retinal detachment (TRD) 12(32.4%), posterior vitreous detachment (PVD) 7(19%), and choroidal detachment (CD) 3(8.1%), were dominant in patients with poorly regulated HbA1c and graded either as moderate NPDR; severe NPDR; and proliferative retinopathy (PR). CONCLUSIONS: Ophthalmic B-mode ultrasound is a rapid, noninvasive imaging technique that can be used with minimum discomfort in ophthalmological practice for the detection and evaluation of DR complications that predict the visual outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA