Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
J Immunol Methods ; 448: 9-20, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28514646

RESUMO

Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Anticoagulantes/sangue , Coleta de Amostras Sanguíneas/métodos , Celulose/análogos & derivados , Monitoramento de Medicamentos/métodos , Heparina/sangue , Testes de Neutralização , Vacinação , Vacina contra Febre Amarela/administração & dosagem , Febre Amarela/prevenção & controle , Vírus da Febre Amarela/imunologia , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Celulose/química , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Ensaio de Placa Viral , Febre Amarela/sangue , Febre Amarela/diagnóstico , Febre Amarela/virologia , Adulto Jovem
2.
Contemp Clin Trials ; 41: 1-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25476584

RESUMO

This study aimed to determine if immunogenicity to measles-mumps-rubella vaccine delivered to infants via a disposable-syringe jet injector (DSJI) was non-inferior to that administered by needle and syringe (NS). Vaccination safety was evaluated, as were the use, performance, and acceptability of each delivery method. The DSJI was the PharmaJet 2009 generation-1 device (G1) and the vaccine was measles-mumps-rubella vaccine from Bio-Manguinhos. Five hundred eighty-two healthy Brazilian infants were randomized to receive vaccine via G1 or NS. Seroconversion rates against measles and mumps viruses in the G1 treatment group did not meet non-inferiority criteria when compared with the NS group; however, responses in the G1 group to rubella virus were non-inferior to those of NS vaccinees. Most adverse events were mild or moderate. Crying after injection was more frequent in the NS group, and local skin reactions were more common in the G1 group. Five serious adverse events were judged causally unrelated to treatment and all resolved. Parents/guardians expressed a strong preference for G1 over NS for their children. Vaccinators found the G1 easy to use but noted incomplete vaccine delivery in some cases. Although the G1 has been superseded by an updated device, our results are important for the continued improvement and evaluation of DSJIs, which have the potential to overcome many of the challenges and risks associated with needle-based injections worldwide. Recommendations for future DSJI clinical studies include rigorous training of vaccinators, quantitative measurement of wetness on the skin following injection, and regular monitoring of device and vaccinator performance.


Assuntos
Injeções Subcutâneas/instrumentação , Vacina contra Sarampo-Caxumba-Rubéola/administração & dosagem , Sarampo/prevenção & controle , Caxumba/prevenção & controle , Rubéola (Sarampo Alemão)/prevenção & controle , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Brasil , Equipamentos Descartáveis , Feminino , Humanos , Imunoglobulina G/imunologia , Lactente , Masculino , Sarampo/imunologia , Vacina contra Sarampo-Caxumba-Rubéola/imunologia , Vacina contra Sarampo-Caxumba-Rubéola/uso terapêutico , Caxumba/imunologia , Aceitação pelo Paciente de Cuidados de Saúde , Rubéola (Sarampo Alemão)/imunologia , Seringas
3.
BMC Infect Dis ; 14: 391, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25022840

RESUMO

BACKGROUND: The live attenuated 17DD Yellow Fever vaccine is one of the most successful prophylactic interventions for controlling disease expansion ever designed and utilized in larger scale. However, increase on worldwide vaccine demands and manufacturing restrictions urge for more detailed dose sparing studies. The establishment of complementary biomarkers in addition to PRNT and Viremia could support a secure decision-making regarding the use of 17DD YF vaccine subdoses. The present work aimed at comparing the serum chemokine and cytokine kinetics triggered by five subdoses of 17DD YF Vaccine. METHODS: Neutralizing antibody titers, viremia, cytokines and chemokines were tested on blood samples obtained from eligible primary vaccinees. RESULTS AND DISCUSSION: The results demonstrated that a fifty-fold lower dose of 17DD-YF vaccine (587 IU) is able to trigger similar immunogenicity, as evidenced by significant titers of anti-YF PRNT. However, only subdoses as low as 3,013 IU elicit viremia kinetics with an early peak at five days after primary vaccination equivalent to the current dose (27,476 IU), while other subdoses show a distinct, lower in magnitude and later peak at day 6 post-vaccination. Although the subdose of 587 IU is able to trigger equivalent kinetics of IL-8/CXCL-8 and MCP-1/CCL-2, only the subdose of 3,013 IU is able to trigger similar kinetics of MIG/CXCL-9, pro-inflammatory (TNF, IFN-γ and IL-2) and modulatory cytokines (IL-5 and IL-10). CONCLUSIONS: The analysis of serum biomarkers IFN-γ and IL-10, in association to PRNT and viremia, support the recommendation of use of a ten-fold lower subdose (3,013 IU) of 17DD-YF vaccine.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Relação Dose-Resposta Imunológica , Vacina contra Febre Amarela/administração & dosagem , Febre Amarela/prevenção & controle , Adolescente , Adulto , Biomarcadores/sangue , Citocinas/sangue , Citometria de Fluxo , Humanos , Cinética , Masculino , Vacinação/métodos , Vacinas Atenuadas/administração & dosagem , Viremia/sangue , Adulto Jovem
4.
Mem Inst Oswaldo Cruz ; 103(7): 711-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19057823

RESUMO

A randomized, double-blinded study evaluating the immunogenicity, safety and consistency of production of a combined diphtheria-tetanus-pertussis-Haemophilus influenzae type b vaccine entirely produced in Brazil by Bio-Manguinhos and Instituto Butantan (DTP/Hib-BM) was undertaken. The reference vaccine had the same DTP vaccine but the Hib component was produced using purified materials supplied by GlaxoSmithKline (DTP/Hib-GSK), which is registered and has supplied the Brazilian National Immunization Program for over more than five years. One thousand infants were recruited for the study and received vaccinations at two, four and six months of age. With respect to immunogenicity, the vaccination protocol was followed in 95.6% and 98.4% of infants in the DTP/Hib-BM and DTP/Hib-GSK groups, respectively. For the Hib component of the study, there was 100% seroprotection (> or =0.15 microg/mL) with all three lots of DTP/Hib-BM and DTP/Hib-GSK. The geometric mean titer (GMT) was 9.3 microg/mL, 10.3 microg/mL and 10.3 microg/mL for lots 1, 2 and 3 of DTP/Hib-BM, respectively, and the GMT was 11.3 g/mL for DTP/Hib-GSK. For diphtheria, tetanus and pertussis, seroprotection was 99.7%, 100% and 99.9%, respectively, for DTP/Hib-BM, three lots altogether and 99.2%, 100% and 100% for DTP/Hib-GSK. GMTs were similar across all lots and vaccines. Adverse events rates were comparable among the vaccine groups. The Brazilian DTP/Hib vaccine demonstrated an immunogenicity and reactogenicity profile similar to that of the reference vaccine.


Assuntos
Vacina contra Difteria, Tétano e Coqueluche/imunologia , Difteria/prevenção & controle , Infecções por Haemophilus/prevenção & controle , Vacinas Anti-Haemophilus/imunologia , Tétano/prevenção & controle , Coqueluche/prevenção & controle , Bordetella pertussis/imunologia , Clostridium tetani/imunologia , Corynebacterium diphtheriae/imunologia , Vacina contra Difteria, Tétano e Coqueluche/administração & dosagem , Vacina contra Difteria, Tétano e Coqueluche/efeitos adversos , Método Duplo-Cego , Feminino , Vacinas Anti-Haemophilus/administração & dosagem , Vacinas Anti-Haemophilus/efeitos adversos , Haemophilus influenzae tipo b/imunologia , Humanos , Lactente , Masculino , Fatores de Tempo
5.
Mem. Inst. Oswaldo Cruz ; 103(7): 711-718, Nov. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-498381

RESUMO

A randomized, double-blinded study evaluating the immunogenicity, safety and consistency of production of a combined diphtheria-tetanus-pertussis-Haemophilus influenzae type b vaccine entirely produced in Brazil by Bio-Manguinhos and Instituto Butantan (DTP/Hib-BM) was undertaken. The reference vaccine had the same DTP vaccine but the Hib component was produced using purified materials supplied by GlaxoSmithKline (DTP/Hib-GSK), which is registered and has supplied the Brazilian National Immunization Program for over more than five years. One thousand infants were recruited for the study and received vaccinations at two, four and six months of age. With respect to immunogenicity, the vaccination protocol was followed in 95.6 percent and 98.4 percent of infants in the DTP/Hib-BM and DTP/Hib-GSK groups, respectively. For the Hib component of the study, there was 100 percent seroprotection (>0.15 µg/mL) with all three lots of DTP/Hib-BM and DTP/Hib-GSK. The geometric mean titer (GMT) was 9.3 µg/mL, 10.3 µg/mL and 10.3 µg/mL for lots 1, 2 and 3 of DTP/Hib-BM, respectively, and the GMT was 11.3 g/mL for DTP/Hib-GSK. For diphtheria, tetanus and pertussis, seroprotection was 99.7 percent, 100 percent and 99.9 percent, respectively, for DTP/Hib-BM, three lots altogether and 99.2 percent, 100 percent and 100 percent for DTP/Hib-GSK. GMTs were similar across all lots and vaccines. Adverse events rates were comparable among the vaccine groups. The Brazilian DTP/Hib vaccine demonstrated an immunogenicity and reactogenicity profile similar to that of the reference vaccine.


Assuntos
Feminino , Humanos , Lactente , Masculino , Vacina contra Difteria, Tétano e Coqueluche/imunologia , Difteria/prevenção & controle , Infecções por Haemophilus/prevenção & controle , Vacinas Anti-Haemophilus/imunologia , Tétano/prevenção & controle , Coqueluche/prevenção & controle , Bordetella pertussis/imunologia , Clostridium tetani/imunologia , Corynebacterium diphtheriae/imunologia , Método Duplo-Cego , Vacina contra Difteria, Tétano e Coqueluche/administração & dosagem , Vacina contra Difteria, Tétano e Coqueluche/efeitos adversos , Vacinas Anti-Haemophilus/administração & dosagem , Vacinas Anti-Haemophilus/efeitos adversos , Haemophilus influenzae tipo b/imunologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA