Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Med (Lausanne) ; 10: 1295633, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954554

RESUMO

Purpose: To compare the risk of transient vision loss (TVL) probably attributable to a severe intraocular pressure spike after intravitreal aflibercept application using the novel prefilled syringe (PFS) vs. the established vial system (VS). Methods: Datasets of the intravitreal injection service of the Ludwig Maximilians-University Munich and the Technical University Munich, Germany, were screened for documentation of TVL after intravitreal injection of aflibercept. The observation period included two full months prior to the introduction of the novel PFS and two months afterwards. TVL was defined as loss of perception of hand motion for a duration of >30 s. Results: Over a period of four months, 1720 intravitreal injections of aflibercept were administered in 672 patients. There were 842 injections with the old VS, and 878 injections using the novel PFS. Using the VS, TVL was noted during two injections (0.24%) in two patients, as compared to 11 cases of TVL (1.25%) in 10 patients with the PFS (p = 0.015). Using the PFS, patients had a 5.3-fold risk of TVL as compared to the VS (OR: 5.33; 95% CI: 1.2-24.1; p = 0.0298). Conclusion: There was a more than five-fold risk of TVL using the novel pre-filled aflibercept syringe as compared to the established vial system. During informed consent, this risk should be discussed.

2.
J Robot Surg ; 17(6): 2735-2742, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37670151

RESUMO

The purpose of this study is to compare robot-assisted and manual subretinal injections in terms of successful subretinal blistering, reflux incidences and damage of the retinal pigment epithelium (RPE). Subretinal injection was simulated on 84 ex-vivo porcine eyes with half of the interventions being carried out manually and the other half by controlling a custom-built robot in a master-slave fashion. After pars plana vitrectomy (PPV), the retinal target spot was determined under a LUMERA 700 microscope with microscope-integrated intraoperative optical coherence tomography (iOCT) RESCAN 700 (Carl Zeiss Meditec, Germany). For injection, a 1 ml syringe filled with perfluorocarbon liquid (PFCL) was tipped with a 40-gauge metal cannula (Incyto Co., Ltd., South Korea). In one set of trials, the needle was attached to the robot's end joint and maneuvered robotically to the retinal target site. In another set of trials, approaching the retina was performed manually. Intraretinal cannula-tip depth was monitored continuously via iOCT. At sufficient depth, PFCL was injected into the subretinal space. iOCT images and fundus video recordings were used to evaluate the surgical outcome. Robotic injections showed more often successful subretinal blistering (73.7% vs. 61.8%, p > 0.05) and a significantly lower incidence of reflux (23.7% vs. 58.8%, p < 0.01). Although larger tip depths were achieved in successful manual trials, RPE penetration occurred in 10.5% of robotic but in 26.5% of manual cases (p > 0.05). In conclusion, significantly less reflux incidences were achieved with the use of a robot. Furthermore, RPE penetrations occurred less and successful blistering more frequently when performing robotic surgery.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Animais , Suínos , Tomografia de Coerência Óptica/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Retina , Vitrectomia/métodos
3.
Micromachines (Basel) ; 14(6)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37374846

RESUMO

This study aimed to compare the efficacy of robot-assisted and manual cannula insertion in simulated big-bubble deep anterior lamellar keratoplasty (DALK). Novice surgeons with no prior experience in performing DALK were trained to perform the procedure using manual or robot-assisted techniques. The results showed that both methods could generate an airtight tunnel in the porcine cornea, and result in successful generation of a deep stromal demarcation plane representing sufficient depth reached for big-bubble generation in most cases. However, the combination of intraoperative OCT and robotic assistance received a significant increase in the depth of achieved detachment in non-perforated cases, comprising a mean of 89% as opposed to 85% of the cornea in manual trials. This research suggests that robot-assisted DALK may offer certain advantages over manual techniques, particularly when used in conjunction with intraoperative OCT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA