Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 89: 41-50, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34343765

RESUMO

PURPOSE: Multicellular tumor spheroids are realistic in-vitro systems used in radiation biology research to study the effect of anticancer drugs or to evaluate the resistance of cancer cells under specific conditions. When combining the modeling of spheroids together with the simulation of radiation using Monte Carlo methods, one could estimate cell and DNA damage to be compared with experimental data. We developed a Cell Population (CPOP) modeler combined to Geant4 simulations in order to tackle how energy depositions are allocated to cells, especially when enhancing radiation outcomes using high-Z nanoparticles. CPOP manages to model large three-dimensional cell populations with independent deformable cells described with their nucleus, cytoplasm and membranes together with force law systems to manage cell-cell interactions. METHODS: CPOP is an opensource platform written in C++. It is divided into two main libraries: a "Modeler" library, for cell geometry modeling using meshes, and a Multi Agent System (MAS) library, simulating all agent (cell) interactions among the population. CPOP is fully interfaced with the Geant4 Monte Carlo toolkit and is able to directly launch Geant4 simulations after compilation. We modeled a full and realistic 3D cell population from SK-MEL28 melanoma cell population cultured experimentally. The spheroid diameter of 550 ± 40 µm corresponds to a population of approximately 1000 cells having a diameter of 17.2 ± 2.5 µm and a nucleus diameter of 11.2 ± 2.0 µm. We decided to reproduce cell irradiations performed with a X-RAD 320 Biological Irradiator (Precision XRay Inc., North Branford, CT). RESULTS: We simulated the energy spectrum of secondary particles generated in the vicinity of the spheroid and plotted the different energy spectra recovered internally to the spheroid. We evaluated also the impact of AGuIX (Gadolinium) nanoparticles modeled into the spheroid with their corresponding secondary energy spectra. CONCLUSIONS: We succeeded into modeling cell populations and combined them with Geant4 simulations. The next step will be to integrate DNA geometrical models into cell nuclei and to use the Geant4-DNA physics and radiolysis modeling capabilities in order to evaluate early strand breaks induced on DNA.


Assuntos
Radiobiologia , Software , Simulação por Computador , DNA , Método de Monte Carlo
2.
Med Phys ; 47(8): 3675-3681, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32422684

RESUMO

PURPOSE: GATE-RTion is a validated version of GATE for clinical use in the field of light ion beam therapy. This paper describes the GATE-RTion project and illustrates its potential through clinical applications developed in three European centers delivering scanned proton and carbon ion treatments. METHODS: GATE-RTion is a collaborative framework provided by the OpenGATE collaboration. It contains a validated GATE release based on a specific Geant4 version, a set of tools to integrate GATE into a clinical environment and a network for clinical users. RESULTS: Three applications are presented: Proton radiography at the Centre Antoine Lacassagne (Nice, France); Independent dose calculation for proton therapy at the Christie NHS Foundation Trust (Manchester, UK); Independent dose calculation for protons and carbon ions at the MedAustron Ion Therapy center (Wiener Neustadt, Austria). CONCLUSIONS: GATE-RTion builds the bridge between researchers and clinical users from the OpenGATE collaboration in the field of Light Ion Beam Therapy. The applications presented in three European facilities using three completely different machines (three different vendors, cyclotron- and synchrotron-based systems, protons, and carbon ions) demonstrate the relevance and versatility of this project.


Assuntos
Terapia com Prótons , Ciclotrons , Método de Monte Carlo , Prótons , Dosagem Radioterapêutica
3.
Phys Med ; 31(8): 861-874, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26653251

RESUMO

Understanding the fundamental mechanisms involved in the induction of biological damage by ionizing radiation remains a major challenge of today's radiobiology research. The Monte Carlo simulation of physical, physicochemical and chemical processes involved may provide a powerful tool for the simulation of early damage induction. The Geant4-DNA extension of the general purpose Monte Carlo Geant4 simulation toolkit aims to provide the scientific community with an open source access platform for the mechanistic simulation of such early damage. This paper presents the most recent review of the Geant4-DNA extension, as available to Geant4 users since June 2015 (release 10.2 Beta). In particular, the review includes the description of new physical models for the description of electron elastic and inelastic interactions in liquid water, as well as new examples dedicated to the simulation of physicochemical and chemical stages of water radiolysis. Several implementations of geometrical models of biological targets are presented as well, and the list of Geant4-DNA examples is described.


Assuntos
DNA/química , Modelos Moleculares , Método de Monte Carlo , Água/química , Fenômenos Químicos , Humanos
4.
Phys Med Biol ; 59(9): 2183-98, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24710744

RESUMO

The GATE Monte Carlo simulation platform based on the Geant4 toolkit is under constant improvement for dosimetric calculations. In this study, we explore its use for the dosimetry of the preclinical targeted radiotherapy of melanoma using a new specific melanin-targeting radiotracer labeled with iodine 131. Calculated absorbed fractions and S values for spheres and murine models (digital and CT-scan-based mouse phantoms) are compared between GATE and EGSnrc Monte Carlo codes considering monoenergetic electrons and the detailed energy spectrum of iodine 131. The behavior of Geant4 standard and low energy models is also tested. Following the different authors' guidelines concerning the parameterization of electron physics models, this study demonstrates an agreement of 1.2% and 1.5% with EGSnrc, respectively, for the calculation of S values for small spheres and mouse phantoms. S values calculated with GATE are then used to compute the dose distribution in organs of interest using the activity distribution in mouse phantoms. This study gives the dosimetric data required for the translation of the new treatment to the clinic.


Assuntos
Melaninas/metabolismo , Melanoma Experimental/radioterapia , Terapia de Alvo Molecular , Método de Monte Carlo , Radiometria/métodos , Animais , Ligantes , Masculino , Melanoma Experimental/diagnóstico por imagem , Camundongos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
5.
Phys Med Biol ; 56(4): 881-901, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21248393

RESUMO

GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Radioterapia/métodos , Tomografia Computadorizada por Raios X/métodos , Benchmarking , Elétrons/uso terapêutico , Humanos , Movimento (Física) , Fótons/uso terapêutico , Tomografia por Emissão de Pósitrons , Terapia com Prótons , Reprodutibilidade dos Testes
6.
Phys Med Biol ; 56(3): 811-27, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21239846

RESUMO

The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.


Assuntos
Elétrons , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Radiometria , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Água
7.
Stud Health Technol Inform ; 138: 34-48, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18560106

RESUMO

The paper describes a platform developed for the secure management and analysis of medical data and images in a grid environment. Designed for telemedicine and built upon the EGEE gLite middleware and particularly the metadata catalogue AMGA as well as the GridSphere web portal, the platform provides to healthcare professionals the capacity to upload and query medical information stored over distributed servers. A job submission environment is also available for data analysis. Security features include authentication and authorization by grid certificates, anonymization of medical data and image encryption. The platform is currently deployed on several sites in Europe and Asia and is being customized for applications in the field of telemedicine and medical physics.


Assuntos
Segurança Computacional/instrumentação , Sistemas Computacionais , Computação em Informática Médica , Sistemas Computadorizados de Registros Médicos/organização & administração , Telemedicina/organização & administração , Acesso à Informação , Algoritmos , Bases de Dados como Assunto , França , Humanos , Método de Monte Carlo , Neurocirurgia/organização & administração , Software
8.
Phys Med Biol ; 53(11): 3039-55, 2008 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-18490808

RESUMO

The GATE Monte Carlo simulation platform based on the Geant4 toolkit has now become a diffused tool for simulating PET and SPECT imaging devices. In this paper, we explore its relevance for dosimetry of low-energy 125I photon brachytherapy sources used to treat prostate cancers. To that end, three 125-iodine sources widely used in prostate cancer brachytherapy treatment have been modelled. GATE simulations reproducing dosimetric reference observables such as radial dose function g(r), anisotropy function F(r, theta) and dose-rate constant (Lambda) were performed in liquid water. The calculations were splitted on the EGEE grid infrastructure to reduce the computing time of the simulations. The results were compared to other relevant Monte Carlo results and to measurements published and fixed as recommended values by the AAPM Task Group 43. GATE results agree with consensus values published by AAPM Task Group 43 with an accuracy better than 2%, demonstrating that GATE is a relevant tool for the study of the dose induced by low-energy photons.


Assuntos
Simulação por Computador , Fótons/uso terapêutico , Neoplasias da Próstata/diagnóstico por imagem , Anisotropia , Braquiterapia/métodos , Humanos , Radioisótopos do Iodo , Masculino , Método de Monte Carlo , Cintilografia
10.
Stud Health Technol Inform ; 112: 249-321, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15923733

RESUMO

Over the last four years, a community of researchers working on Grid and High Performance Computing technologies started discussing the barriers and opportunities that grid technologies must face and exploit for the development of health-related applications. This interest lead to the first Healthgrid conference, held in Lyon, France, on January 16th-17th, 2003, with the focus of creating increased awareness about the possibilities and advantages linked to the deployment of grid technologies in health, ultimately targeting the creation of a European/international grid infrastructure for health. The topics of this conference converged with the position of the eHealth division of the European Commission, whose mandate from the Lisbon Meeting was "To develop an intelligent environment that enables ubiquitous management of citizens' health status, and to assist health professionals in coping with some major challenges, risk management and the integration into clinical practice of advances in health knowledge." In this context "Health" involves not only clinical procedures but covers the whole range of information from molecular level (genetic and proteomic information) over cells and tissues, to the individual and finally the population level (social healthcare). Grid technology offers the opportunity to create a common working backbone for all different members of this large "health family" and will hopefully lead to an increased awareness and interoperability among disciplines. The first HealthGrid conference led to the creation of the Healthgrid association, a non-profit research association legally incorporated in France but formed from the broad community of European researchers and institutions sharing expertise in health grids. After the second Healthgrid conference, held in Clermont-Ferrand on January 29th-30th, 2004, the need for a "white paper" on the current status and prospective of health grids was raised. Over fifty experts from different areas of grid technologies, eHealth applications and the medical world were invited to contribute to the preparation of this document.


Assuntos
Redes de Comunicação de Computadores , Sistemas de Informação , Redes de Comunicação de Computadores/organização & administração , Europa (Continente) , Humanos , Sistemas de Informação/organização & administração , Cooperação Internacional , Aplicações da Informática Médica
11.
Phys Med Biol ; 49(19): 4543-61, 2004 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-15552416

RESUMO

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.


Assuntos
Simulação por Computador , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Método de Monte Carlo , Reprodutibilidade dos Testes , Termodinâmica
12.
Phys Med Biol ; 49(2): 271-85, 2004 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15083671

RESUMO

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.


Assuntos
Câmaras gama , Animais , Simulação por Computador , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Espalhamento de Radiação , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA